Expression of CD44 variant exons by primary and metastatic oral squamous carcinomas.

Abnormal CD44 expression in many neoplasms correlates with behaviour, but reports on its role in oral squamous carcinoma are contradictory. CD44 expression was characterised in a closely matched series of oral carcinomas with and without metastases in both frozen and formalin-fixed tissue and correlated with behaviour and histological grading parameters. Eleven primary oral squamous carcinomas without metastases and nine primary carcinomas with 19 matched metastases were stained immunocytochemically for CD44H and products of variant exons v3, v4/5, v6 and v9. Patterns of staining in frozen and formalin-fixed tissue were correlated with invasive front grading and behaviour using exact inferential statistics. Most primary carcinomas stained for all exons tested but some showed loss of expression of v4/5. Loss of expression was more marked in metastases, but there was no correlation between expression and behaviour or grade. Stromal surfaces of epithelial cells often expressed variant exon products reflecting loss of polarity. This, together with selective loss of v4 and v5 in primary carcinomas and their more frequent loss in metastases, suggests that CD44 may play a role in metastasis of some oral squamous carcinomas.

Aged↗

Factors associated with the presence of denture related stomatitis in complete denture wearers: a preliminary investigation.

Various factors have been associated with the presence of denture related stomatitis. These include local factors such as continuous denture wear, trauma from dentures and poor denture hygiene Systemic factors, use of various pharmacological agents and smoking have also been implicated. This investigation involved history taking and examination of 250 patients attending Guy's Hospital for the construction of complete dentures. No association was found between systemic factors, use of pharmacological agents or smoking and the presence of denture related stomatitis. Night wear of complete dentures was found to be significantly associated with the prevalence of denture related stomatitis.

Chi-Square Distribution↗

The distortion of cast cobalt-chromium alloy partial denture frameworks fitted to a working cast.

PURPOSE: This in vitro study examined the distortion of 10 identically designed cast cobalt-chromium alloy frameworks, individually constructed, and adjusted by 10 technicians to fit one of 10 replicated stone working casts. MATERIAL AND METHODS: The distortion was measured with a specially developed strain gauge apparatus when the frameworks were seated on the maxillary metal analog, the stone working cast, or a stone duplicate cast. RESULTS: A statistically significant difference between the distortion of each of the frameworks was observed. A significant difference in the distortion was also observed for the frameworks when placed on each of the three casts. The distortion was the least when the frameworks were seated on the stone working cast and the greatest when seated on the metal analog. CONCLUSION: This study demonstrated that the distortion of a framework is not related to its closeness of fit as observed by the presence or absence of gaps between the framework components and the teeth.

Alloys↗

In vivo changes in roughness of resin-modified glass ionomer materials.

OBJECTIVES: The clinical changes in roughness of resin-modified glass ionomer materials is relatively unknown. This study examined the in vivo wear of these materials using surface roughness as an indicator of wear patterns. METHODS: Ten patients with four cervical abrasion lesions each were selected. The four cavities in each patient were restored with Fuji II LC (GC Corp., Japan), Vitremer (3M Dental, USA), Photac-Fil (ESPE, Germany) and Fuji Cap II (GC Corp., Japan). After light-curing, the restorations were polished and left uncoated. Silicone impressions were made of the surface of each restoration after polishing, and then at 3 monthly intervals up to 24 mon after restoration placement. Gold-coated resin replicas were made from the impressions for surface wear evaluation. Quantitative assessment of wear was performed by measuring surface roughness with a confocal microscope for topographical reconstruction of the specimen surface. The effect of material at each time period was analyzed using the Kruskal-Wallis test with exact non-parametric inference. Rugosity, as determined by the center line average, was determined by image analysis. SEM images of the same surfaces provided the qualitative analysis. RESULTS: All restorations showed a cyclic distribution of rugosity with time as demonstrated by lowess plots. There were significant differences between materials at 6, 9 and 18 mon. The rugosity curves appeared to converge at 24 mon. SIGNIFICANCE: It was concluded that the in vivo surface changes in roughness of resin-modified glass ionomer materials is cyclic in nature over the first 2 y.

Adult↗

An investigation into the placement of force delivery systems and the initial forces applied by clinicians during space closure.

This in vitro investigation was designed to establish not only how clinicians apply forces for space closure when using the straight wire appliance and sliding mechanics, but also to quantify the initial force levels produced. A single typodont, with residual extraction space in each quadrant, was set up to simulate space closure using sliding mechanics. On two occasions, at least 2 months apart, 18 clinicians were asked to apply three force delivery systems to the typodont, in the manner in which they would apply it in a clinical situation. The three types of force delivery system investigated were elastomeric chain, an elastomeric module on a steel ligature, and a nickel-titanium closed coil spring. A choice of spaced or unspaced elastomeric chain produced by a single manufacturer was provided. The amount of stretch which was placed on each type of system was measured and, using an Instron Universal Testing Machine, the initial force which would be generated by each force delivery system was established. Clinicians were assessed to examine their consistency in the amount of stretch which each placed on the force delivery systems, their initial force application and their ability to apply equivalent forces with the different types of force delivery system. The clinicians were found to be consistent in their method of application of the force delivery systems and, therefore, their force application, as individuals, but there was a wide range of forces applied as a group. However, most clinicians applied very different forces when using different force delivery systems. When using the module on a ligature the greatest force was applied, whilst the nickel titanium coil springs provided the least force.

Dental Alloys↗

The effect of timing of archwire placement on in vivo bond failure.

At the commencement of fixed appliance therapy the operator has the choice of either placing bands, brackets, and archwires at one visit, and hence loading the brackets within an hour of initial placement, or placing the brackets and separators at one visit, and the bands and archwires at a subsequent visit. In the case of the latter, the brackets will only be loaded intermittently during the intervening period, for example during mastication. The present study investigated the effect of loading bonded brackets for 2 weeks prior to measuring shear debonding force in vitro, and compared the results with in vivo bond failure rates for two groups of patients whose brackets were loaded by the archwire either immediately after bonding, or not less than 1 week later. Shear testing and survival analysis indicated in vitro loading prior to testing had no significant effect on the shear debonding force. When the in vivo data were studied there was no significant difference in the rate of bond failure between those patients whose archwires were placed at the time of fitting the appliance, and those whose archwires were placed no less then 1 week after bracket placement.

Acid Etching, Dental↗

The effects of maturity and dehydration shrinkage on resin-modified glass-ionomer restorations.

The dimensional change, including hygroscopic change, of adhesive dental materials is a clinically important topic, since excessive changes could cause debonding from tooth structure. The water balance of glass-ionomer cements arises mainly from their sensitivity to the environment; depending on the surroundings, they can gain or lose water, either of which can be potentially damaging. These effects become less noticeable as the cement ages. The effects of maturity of the newer resin-modified glass-ionomer materials and their responses to changes in moisture are unknown. Using confocal microscopy, we examined the effects of dehydration stress on the glass-ionomer/tooth interface in specimens of various degrees of maturity. Wedge-shaped cervical cavities in extracted teeth were restored with one of three resin-modified glass-ionomer restorative materials. The control specimens were restored with a conventional glass ionomer. The samples were left to mature, then sectioned and examined at 1 day, 1 wk, 1 mo, 3 mos, 6 mos, and 1 yr. After being sectioned, each specimen was examined immediately with a confocal microscope with water-immersion objectives so that the subsurface interfacial characteristics could be studied. The specimen was then allowed to dehydrate under the microscope, with further examinations at 15, 30, and 60 min. Generally, gap formation at the interface occurred within 15 min of dehydration. All materials showed a different pattern of gap change with maturity, probably due to the different setting mechanisms involved. All of them were susceptible to dehydration shrinkage up to 3 mos of maturity. At 6 mos and 1 yr, Fuji II and Fuji II LC showed insensitivity to dehydration. Vitremer and Photac-Fil showed less sensitivity to dehydration at 1 yr than at 6 mos. The results of this study of the maturing polymerized resin-modified cements have potential clinical implications in the handling of these materials; the addition of resin has not significantly reduced the glass ionomer's susceptibility to dehydration problems.

Analysis of Variance↗

Measurement of the microhardness and Young's modulus of human enamel and dentine using an indentation technique.

Conventional quasi-static and dynamic test methods have a number of limitations when used to measure the mechanical properties of enamel and dentine. These are due to the complex structure of the material and the small specimen size. In this investigation, a microindentation technique was used to measure the hardness and Young's modulus of human enamel and dentine and any variations with location. Freshly extracted molar teeth were sectioned, and the cut surfaces were ground and polished progressively to 1 micron. The polished surfaces were indented at different distances from the surface and amelodentinal junction with a Knoop indentor. Measurements of the length of the long indentation diagonal were used to calculate a value for hardness. It has been shown that the a-value for Young's modulus of a material can be calculated by comparing the ratio of the long and short diagonals on an indented specimen with the actual ratio of the indentor as any changes will be due to elastic recovery in the specimen. Values obtained for the Knoop hardness of enamel and dentine were in good agreement with those of other workers. It was also possible to show that there was a decrease in hardness with depth from the surface in enamel. The hardness of dentine increased with distance from the amelodentinal junction. Values for Young's modulus for dentine were in good agreement with those of other workers, and there was an increase in modulus with depth from the amelodentinal junction from 8.7 to 11.2 GNm-2. Values for Young's modulus of enamel were not as easy to calculate because of surface- and subsurface damage.

Confidence Intervals↗

The effect of static loading in orthodontic bonding.

The aim of this investigation was to determine the effect of static loading on the measured shear bond strength of steel attachments bonded to enamel. Sixty steel attachments were bonded to extracted and prepared premolar teeth with Orthodontic Concise (3M St Paul, Minnesota, USA) and allowed to bench cure for 2 weeks. Half the specimens had 78 g weights suspended from the attachment, close to the bondline, prior to testing. The mean shear bond strength for the statically loaded samples was 127 N and for the unloaded 85.4 N. The 95 per cent confidence intervals for the difference between the means was 26.7-56.8 N indicating that static loading prior to shear testing significantly increases shear bond strength.

Adhesives↗

An in vitro comparison between a bonded retainer system and a directly bonded flexible spiral wire retainer.

Bonded lingual retainers are becoming more popular to stabilize the results of orthodontic treatment. The in vitro shear strength of a flexible spiral wire (FSW) retainer (Zachrisson, 1977, 1983) bonded with Prisma Fil was compared to the 'A'-Company bonded lingual retainer system, bonded with either Concise or Right-On, to human enamel. Statistical analysis of the results showed no significant differences between the 'A'-Company system when bonded with Concise or Right On, Concise having a greater mean bond strength, but also a greater range of bond strength values. All the materials tested gave bond strengths that were adequate for clinical practice and it is concluded that the choice of bonded retainer system can be made upon grounds of clinical convenience or cost.

Bisphenol A-Glycidyl Methacrylate↗

An investigation into the ability of soft drinks to adhere to enamel.

Loss of enamel due to dietary causes, either by acid erosion or the fermentation of dietary sugars, is well known. These processes will be affected by a number of factors, one of which is the ability of the food to adhere to the enamel. The aim of this study was to determine the thermodynamic work of adhesion of a number of soft drinks to enamel. The results indicated significant differences in the ability of various drinks to adhere to enamel in vivo. In addition to obtaining a ranking of the drinks under test, the likelihood of them being displaced by saliva was considered.

Analysis of Variance↗

The prognostic value of individual histologic grading parameters in small lingual squamous cell carcinomas. The importance of the pattern of invasion.

BACKGROUND: The histologic grading of the deep invasive margin of oral squamous cell carcinoma recently has been shown to have prognostic value, but previous series have not been homogeneous enough to allow grading parameters to be assessed individually. METHODS: Forty-seven small lingual carcinomas limited to the lateral border of the tongue and treated by radiotherapy were graded histologically at their deep invasive front. Clinical and grading parameters were correlated by statistical tests performed by permutational techniques. RESULTS: Carcinoma recurred locally in 6 patients, and metastases developed in 19. Local recurrence correlated with Broders' grade (P = 0.0143), keratinization (P = 0.017) and pattern of invasion (P = 0.0195). Metastasis had a highly significant correlation with Broders' grade (P < 0.001), pattern of invasion (P < 0.001), and invasive front grading total score (P < 0.001). Seven of 8 carcinomas with diffuse infiltrating patterns metastasised, whereas only 4 of 25 with large islands or a broad infiltrating pattern metastasized. CONCLUSIONS: The usefulness of the deep invasive front grading system for small lingual carcinoma was demonstrated. The pattern of invasion was the component of the grading system that had the closest correlation with metastasis and recurrence in this type of carcinoma.

Carcinoma, Squamous Cell↗

Use of an adhesive resin for bonding orthodontic brackets.

To date, most successful bonding agents used in orthodontics rely on mechanical retention to both the enamel and bracket base. Chemical adhesion to enamel as seen with glass ionomer cements, and to the silanated base of ceramic brackets have been tried. Recent developments in resin formulation have led to the production of adhesive diacrylate resins capable of forming adhesive bonds to certain metals including stainless steel. The aim of this experiment was to compare such a resin, Panavia EX, with a more conventional 'no-mix' orthodontic bonding resin. Two different base retention mechanisms were used, and the effect of rebonding and differing environmental conditions were also investigated. The results indicated that Panavia EX could produce greater bond strengths than the more conventional bonding resin. Of the two base retention systems tested, braised mesh bases gave consistently greater bond strengths than the cast base, although no base/resin specificity could be detected. Re-using the same brackets showed rebound strengths to be significantly lower than initial bond strength although the results indicated the adhesive resin was still able to bond more effectively to these used brackets than the conventional resin. Environment had the greatest effect on bond strength, such that following environmental exposure there was no significant difference between the two resins. This latter factor, and in particular the more complex bonding technique required for the adhesive resin, means that Panavia EX cannot be recommended for orthodontic use in its present form.

Acrylic Resins↗

Sri Lankan cleft lip and palate study model analysis: clefts of the secondary palate.

The study models of a group of adult Sri Lankan patients with clefts of the secondary palate were investigated. Tooth-size and arch-dimension comparisons were made with a comparable control group. Significant differences were found between the cleft and control groups in tooth sizes, chord lengths, and arch widths. The cleft group dimensions were generally smaller than those of the control group. Overjets were larger in the cleft group.

Adult↗