[Coincidence of angiomyolipoma of the liver and kidney].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Völk.
Explore the source record for details and available documents.
RATIONALE AND OBJECTIVES: To compare blood flow velocities in the carotid arteries measured with three different magnetic resonance (MR) phase-contrast imaging techniques and with percutaneous Doppler ultrasound. METHODS: Fourteen healthy male volunteers with a mean age of 33 +/- 3.8 years were studied. Ultrasound and MR phase velocity mapping of both common carotid arteries (n = 28) was performed within 5 hours. A two-dimensional fast low-angle shot sequence with retrospective cardiac gating, a sequence with prospective cardiac triggering, and a breath-hold sequence with prospective cardiac triggering were used. Resistance indexes and pulsatility indexes were calculated for all modalities. RESULTS: The comparison of flow velocities obtained with ultrasound and the different MR techniques led to a moderate correlation of the retrospective gated and prospective triggered MR techniques (eg, r = 0.73 for maximum systolic velocity). The worst correlation was found between the breath-hold technique and retrospective cardiac gating (eg, r = 0.004 for pulsatility index). There was a weak correlation of all three MR sequences compared with ultrasound (r = 0.19-0.60) CONCLUSIONS: A moderate correlation was found between velocities and indexes measured with the prospective cardiac-triggered phase-contrast MR technique and the retrospective cardiac-gated phase-contrast MR technique. A weak correlation was found between the three different MR techniques and ultrasound, as well as between the breath-hold prospective cardiac-triggered MR sequence and both of the other MR sequences. The influence of temporal and spatial resolution on MR phase-contrast velocity mapping was confirmed.
RATIONALE AND OBJECTIVES: To evaluate the appearance of the vessel lumen after implantation of different vascular stents with the use of a computed tomographic (CT) angiography model. METHODS: A vascular phantom was studied with helical CT and different slice thicknesses (2 and 3 mm) and pitch values (1.0, 1.5, and 2.0). Original transverse CT images and coronal reformations were evaluated. Fourteen different stents were analyzed with regard to changes in the stent lumen (attenuation values, noise, and artificial lumen narrowing). RESULTS: Some stents caused artifacts resulting in potential errors during evaluation of their patency. Assessment of the lumen was impaired in two stents (Strecker tantalum and Passager). Increased attenuation values were measured in all stents (increase of 8%-145%). The degree of artificial lumen narrowing was 4.4% to 77.8%. CONCLUSIONS: In most stents, reliable evaluation of the stent lumen seems possible. However, knowledge of the artifacts caused by different stent types is useful for the assessment of stent patency with CT angiography.
OBJECTIVE: The authors evaluate blood flow velocities in the medial cerebral artery (MCA) and the basilar artery using magnetic resonance (MR) phase contrast technique in comparison with transcranial Doppler ultrasound (TCD). Eleven healthy male volunteers were studied. TCD of the MCA (n = 22) and basilar artery (n = 11) was performed. MR phase velocity mapping was done in each vessel at the same location where the TCD signal had been acquired. A 2-dimensional FLASH sequence with retrospective cardiac gating and an average temporal resolution of 45 ms was used. Resistance indices (RIs) and pulsatility indices (PIs) were calculated for both modalities. The TCD insonation angle was measured retrospectively with MR, and TCD velocities were corrected based on these measurements. The comparison of flow velocities obtained with TCD and MR led to a low correlation coefficient with regard to the basilar artery and the MCA: maximum systolic velocity, r = 0.02 and r = 0.50, respectively; enddiastolic velocity, r = 0.47 and r = 0.65, respectively; mean velocity, r = 0.52 and r = 0.66, respectively. The average PIs in the basilar artery and the MCA were 0.80 and 0.81 with MR and 0.65 and 0.85 with TCD, respectively. The average RIs in the basilar artery and the MCA were 0.52 and 0.54 with MR and 0.52 and 0.55 with TCD, respectively. The TCD insonation angle differed significantly from the ideal value in the basilar artery (mean value = 32.6 degrees) and the MCA (mean value = 26.5 degrees). The authors find a low correlation between velocities measured with MRI and TCD but similar results with regard to the PIs and RIs. Several sources of error, such as a nonideal TCD insonation angle, were identified.
OBJECTIVE: The purpose of this study was to evaluate the visibility of the IXth to XIIth cranial nerves using different magnetic resonance sequences. Thirty healthy volunteers underwent magnetic resonance imaging at 1.5 T using 3-dimensional constructive interference in steady state (CISS) sequence (TR = 17 ms, TE = 8.08 ms, alpha = 70 degrees), 3-dimensional magnetization-prepared rapid gradient echo (MP-RAGE) sequence (TR = 11.08 ms, TE = 4.3 ms, alpha = 15 degrees), and T2-weighted (w) 2-dimensional turbo spin echo (TSE) sequence (TR = 4000 ms, TE = 102 ms, alpha = 180 degrees, slice thickness = 2 mm). Visibility of the IXth to XIIth cranial nerves in each sequence was evaluated by consensus of 2 radiologists using an evaluation scale from 1 (excellently visible) to 5 (not visible). A correlation with anatomic specimens was made. The 3-dimensional CISS sequence provides best resolution of the IXth to XIIth cranial nerves and their relation to surrounding structures. Additional information is given by the 3-dimensional MP-RAGE when nerves are surrounded by soft tissues. Using the T2w 2-dimensional TSE sequence, even whole nerves cannot be visualized due to intersection gap and partial volume effects. However, even in 3-dimensional high-resolution sequences, segments of nerves are not always visualized. A combination of 3-dimensional CISS and 3-dimensional MP-RAGE proved to be useful to visualize the IXth to XIIth cranial nerves, whereas the 2-dimensional technique failed. Further investigations using 3-dimensional MP-RAGE with contrast medium should be performed in the case of abnormality.
PURPOSE: To assess the feasibility of magnetic resonance (MR) imaging-guided stent placement in iliac arterial stenoses. MATERIALS AND METHODS: Thirteen patients with 14 iliac arterial stenoses were examined prospectively. Angioplasty was performed through a femoral sheath by using a conventional 1.5-T MR imaging system. Stents and catheters were visualized on the basis of their artifacts. Nitinol stents were placed with gradient-echo MR imaging guidance. Angioplasty balloons were inflated with gadolinium-based contrast material. Results were evaluated clinically and with both digital subtraction angiography (DSA) and contrast material-enhanced MR angiography. RESULTS: Ten of 13 patients were treated with technical success by using MR imaging-guided intervention alone. Three patients were treated with additional fluoroscopic guidance, because complications (ie, panic attack, subintimal recanalization, and stent misplacement) occurred with MR guidance. The quality of the postinterventional contrast-enhanced MR angiograms of three of 12 lesions with stents was limited owing to stent-induced signal loss of the lumen. The mean stenosis degree after stent placement was significantly higher at contrast-enhanced MR angiography than at DSA (24.6% vs 6.2%). The mean MR imaging-guided procedure time was 74 minutes. CONCLUSION: MR imaging-guided stent placement in iliac arteries is feasible in select patients. The presented technique has limitations-that is, long procedure times, lack of real-time monitoring, and stent artifacts-that necessitate further modifications before it can be recommended for clinical use.
PURPOSE: Results with different doses of gadobenate dimeglumine and gadopentetate dimeglumine were compared at magnetic resonance (MR) angiography of the renal arteries. The signal-to-noise ratio (SNR) was evaluated as a quantitative measure of image quality. MATERIALS AND METHODS: Sixty consecutive patients (age range, 24-81 years; mean age, 65 years) underwent intraarterial digital subtraction angiography (DSA) and contrast material-enhanced time-resolved MR angiography. DSA was the standard of reference. Fifteen patients received gadopentetate dimeglumine at doses of 0.2 or 0.1 mmol per kilogram of body weight. Fifteen patients received gadobenate dimeglumine at doses of 0.05 or 0.1 mmol/kg. The SNR was calculated in the aorta and both main renal arteries. The number and degree of stenoses of the renal arteries and accessory vessels were evaluated by four observers. RESULTS: SNRs with gadobenate dimeglumine at a dose of 0.1 mmol/kg were significantly superior to those with gadopentetate dimeglumine at a dose of 0.1 mmol/kg. Differences were not statistically significant between the SNRs in the other groups. Eleven (85%) of 13 hemodynamically significant renal artery stenoses were detected correctly with MR angiography as were 22 (85%) of 26 accessory renal arteries. CONCLUSION: SNRs with gadobenate dimeglumine were higher than those with gadopentetate dimeglumine, but in most cases the differences in SNRs were not statistically significant.
OBJECTIVE: To determine sensitivity and specificity of high-resolution MR imaging and of high-resolution axial CT (HRCT) and to compare the two modalities in predicting the surgical and functional success of cochlear implantation. MATERIAL AND METHODS: The presurgical MR images (2D T2W TSE, 3D T2*W CISS, plain and contrast-enhanced 3D T1W MP-RAGE) and axial HRCT findings of 26 patients were evaluated with regard to the predictive value concerning the success of cochlear implantation. RESULTS: We found a high correlation between MR and HRCT and the success of cochlear implantation. In all 26 patients, the MR-based predictions concerning the success of cochlear implantation were correct. In 10 patients, MR gave additional information to HRCT. In all patients, MR gave sufficient information about the status of the inner ear, inner auditory canal and cochlear nerve to aid the surgeon during the operation. CONCLUSION: A high-resolution MR protocol consisting of coronal 2D T2W TSE, 3D T2*W axial CISS, plain and contrast-enhanced sagittal T1W 3D MP-RAGE is recommended for the evaluation of candidates scheduled for cochlear implantation. It provides information which cannot be obtained by HRCT.
AIM: The purpose of this study was to evaluate a large-area, flat-panel X-ray detector (FD), based on caesium-iodide (CsI) and amorphous silicon (a-Si) with respect to skeletal radiography. Conventional images were compared with digital radiographs using identical and reduced radiation doses. MATERIALS AND METHODS: Thirty consecutive patients were studied prospectively using conventional screen-film radiography (SFR; detector dose 2.5 microGy). Digital images were taken from the same patients with detector doses of 2.5, 1.25 and 0.625 microGy, respectively. The active-matrix detector had a panel size of 43 x 43 cm, a matrix of 3 x 3K, and a pixel size of 143 microm. All hard copies were presented in a random order to eight independent observers, who rated image quality according to subjective quality criteria. Results were assessed for significance using the Student's t -test (confidence level 95%). RESULTS: A statistically significant preference for digital over conventional images was revealed for all quality criteria, except for over-exposure (detector dose 2.5 microGy). Digital images with a 50% dose showed a small, statistically not significant, inferiority compared with SFR. The FD-technique was significantly inferior to SFR at 75% dose reduction regarding bone cortex and trabecula, contrast and overall impression. No statistically significant differences were found with regard to over- and under-exposure and soft tissue presentation. CONCLUSION: Amorphous silicon-based digital radiography yields good image quality. The potential for dose reduction depends on the clinical query.
PURPOSE: The aim of this study was to determine the presurgical predictive value of high resolution MRI in patients scheduled for cochlear implantation. METHOD AND MATERIAL: The presurgical MRI (3D CISS, 3D MP-RAGE with and without i.v. contrast medium, 2D TSE) findings of 54 patients and the intraoperative situation reported by the surgeon were compared retrospectively. The surgical and functional success of the cochlear implantation was evaluated. RESULTS: We found a high degree of correlation between MRI and intraoperative findings concerning the patency of the whole cochlea and anomalies as well as in the diagnosis of pathology of the cochlear, vestibular and facial nerves and in anomalies of the internal auditory canal. However, in four out of 54 patients there was a false negative prediction regarding the patency of the cochlea. The sensitivity was 50% (4/8), the specificity 100% (46/46). Concerning the surgical success the accuracy was 100%. In all patients MRI gave sufficient anatomical information to the surgeon concerning the jugular bulb and the facial nerve. CONCLUSION: A high-resolution MRI protocol consisting of coronal 2D T2w TSE, 3D T2*w transverse CISS; plain and contrast enhanced sagittal T1w 3D MP-RAGE is recommended for the evaluation of candidates scheduled for cochlear implantation.
PURPOSE: To investigate the feasibility of MR-guided stent angioplasty of iliac artery stenoses under passive visualization. MATERIAL AND METHODS: Three patients with short, concentric stenoses of the iliac arteries were enrolled. The vascular interventions were performed on a 1.5 T MR scanner (Magnetom Symphony, Siemens, Erlangen, Germany). Stents, guidewires, and balloon catheters were visualized on the basis of susceptibility artifacts. Contrast-enhanced MR angiography (ceMRA) was used to localized the stenosis prior to stent deployment. Nitinol stents were placed under MR-guidance using a fast 2D gradient echo technique. Balloon dilatiation was performed with an angioplasty catheter inflated with diluted gadolinium-DTPA. Postinterventional results were evaluated by ceMRA, DSA, and Doppler indices. RESULTS: Position of the stent, stent deployment, and balloon dilatation were depicted by MR. All stents were correctly placed within the stenosis. Stent positions as monitored by MRI were identical to those seen on DSA images. All patients were treated successfully by the MR-guided intervention. CONCLUSION: An MR-guided stent angioplasty of simple iliac artery stenosis is feasible under passive visualization.
PURPOSE: To evaluate contrast enhanced magnetic resonance angiography (ceMRA) of the pelvic and peripheral arteries with a dedicated peripheral vascular coil system and automated table-feed technique in patients with arterial occlusive disease. METHODS: Three-dimensional gadolinium-enhanced MR angiography in a two-step automatic table feed technique was performed in 45 patients using a 1.5 Tesla imager (Magnetom Symphony, Siemens). The pelvic arteries were imaged with a single injection of contrast material. The upper and the lower leg were imaged with a second injection of contrast material in an automated table feed technique using a dedicated vascular coil system. In 20 patients ceMRA was compared with digital subtraction angiography (DSA) as the standard of reference and in 25 patients ceMRA was performed solely. RESULTS: Sensitivity and specificity for grading significant stenoses > or = 50% and occlusions (in parenthesis) were in the pelvic arteries 94.7%, 96.8%, (100%, 100%), in the arteries of the upper leg 92.3%, 93.3% (87.5%, 100%) and in the arteries of the lower leg 96.5%, 95.8%, (95.2%, 96.8%), respectively. Depiction of the runoff vessels of the lower leg was excellent in ceMRA. CeMRA was of diagnostic quality in all the patients. CONCLUSION: Contrast-enhanced MRA using a dedicated peripheral vascular coil system increases the diagnostic quality of the lower leg. The runoff vessels can be evaluated. Thus, ceMRA in the presented technique is a diagnostic alternative to arterial angiography.
PURPOSE: To obtain morphologic and functional information in patients with dissection of the descending aorta using contrast-enhanced MR angiography (MRA) and MR blood flow quantification of the true and false lumina. MATERIAL AND METHODS: Fourteen patients were studied prospectively using a 1.5 T unit. MRA was performed with a 3D FISP sequence (TR/TE/flip angle 4.7/1.9 ms/30 degrees) after injection of 0.2 mmol Gd-DTPA per kg b.w. Flow quantification with phase velocity mapping was done at the level of the diaphragm using a 2D FLASH technique (TR/TE/flip angle 28/6.5 ms/30 degrees) with an average temporal resolution of 23 frames per cardiac cycle (34 ms). A spectral broadening index was applied to quantify the amount of flow irregularity within both channels of the aorta. Extension of the dissection and involvement of the major branch vessels were analyzed. RESULTS: The mean flow volume per minute was 1,982 ml (SD 1,083 ml) in the true and 1,052 ml (SD 763 ml) in the false lumen. Average peak-velocities were 98 cm/s (SD 33 cm/s) in the true channel and 47 cm/s (SD 26 cm/s) in the false channel. Ten patients had bidirectional flow in the false lumen with a reflux volume ranging between 6.8% and 98%. Only 1 patient presented with bidirectional flow in the true lumen (reflux volume 15%). A significantly higher degree of flow irregularity was found in the false lumen compared with the true channel. CONCLUSION: Different hemodynamic patterns were found in aortic dissection. Their prognostic value and the impact on therapy, specifically percutaneous interventional procedures, have to be further studied.
RATIONALE AND OBJECTIVES: To investigate the image quality of a digital radiography system with an amorphous-silicon, large-area, digital flat-panel detector. METHODS: A flat-panel detector based on a matrix of amorphous silicon was integrated into a projection radiography system. The scintillator consisted of a layer of structured cesium iodide. The active matrix size of 30002 pixels together with a pixel size of 143 microm provided a large image area of 43 x 43 cm2. Basic image quality parameters such as detective quantum efficiency (DQE) and modulation transfer function (MTF) were measured and compared with those obtained with conventional systems. RESULTS: The measurement of DQE yielded a high value of 70% at zero spatial frequency. At a system dose equivalent to 400 speed, the DQE of the digital system was a factor of two larger than the DQE of a storage phosphor or screen-film system within the entire spatial frequency range between zero and the Nyquist limit of 3.5 line pairs per millimeter. The flat-panel detector furthermore has an MTF that is superior to that in regular screen-film systems and also provides a substantially larger dynamic range. CONCLUSIONS: This new technology demonstrates its potential to provide equal or superior image quality to conventional screen-film systems and to reduce patient exposure to radiation dose. The advantages of digital radiography systems, based on a flat-panel detector as an instant image display, facilitation of work flow in the radiology department, and digital networking and archiving, are well in sight.
RATIONALE AND OBJECTIVES: To evaluate MR imaging features of commercially available stents before, during, and after in vitro deployment as a step toward MR-guided stent deployment. METHODS: Fourteen stents were deployed in a phantom under MR monitoring at 1.5 T by using a gradient-echo sequence. Device visibility was rated on a four-point scale (excellent, fair, poor, not visible). RESULTS: The Memotherm stent and the rolling membrane (RM) Wallstent showed excellent stent visibility and at least fair scores for artifact-induced narrowing of the stent lumen. Three stents (Palmaz, AVE, Easy Wallstent) showed excellent visibility of the stent but no visible lumen. Five stents (Strecker, Accuflex, Hemobahn, Passager, Sinus) displayed fair visibility. The delivery catheters of four stent systems (Smart, Vascucoil, Symphony, ZA) displayed severe black hole artifacts. CONCLUSIONS: The imaging features of several stent systems might be suitable for MR-guided intervention. The Memotherm and the Wallstent RM combine good visibility of the stent and the lumen.
RATIONALE AND OBJECTIVES: We performed a prospective comparison of T1-weighted turbo spin-echo (TSE) imaging with standard averaging and with the long-term averaging method (LOTA), comparing the effects on signal-to-artifact noise ratio (S/aN) and motion artifacts. METHODS: In 30 consecutive patients undergoing imaging of the neck or cervical spine, a transverse T1-weighted TSE sequence was applied with and without LOTA by using identical sequence parameters. Quantitative image analysis was done by calculating S/Ns in the phase-encoding direction (S/aN). Visual image analysis was performed by four independent, masked readers using a standardized score sheet for anatomic and pathological findings. RESULTS: The LOTA sequence yielded significantly superior S/aN values compared with the standard averaging sequence. In the subjective evaluation, the LOTA sequence showed significantly fewer motion artifacts and better visualization of normal anatomy of the neck, cervical spine, and spinal cord, as well as of the pathological findings. CONCLUSIONS: LOTA is a valuable method for increasing S/aN in magnetic resonance imaging of the neck and cervical spine. It reduces motion artifacts and increases the conspicuity of pathology without increasing acquisition time. No additional hardware is needed, and this technique can be combined with other artifact-reducing methods.
The purpose of this study was to evaluate a large-area, flat-panel X-ray detector, which uses cesium-iodide (CsI) and amorphous silicon (a-Si). Conventional images were compared with digital images acquired with equal dose (2.5 microGy) and with 50% dose reduction. Fifteen consecutive patients were studied prospectively using an asymmetric screen-film system (detector dose, 2.5 microGy). Digital images were taken from the same patients in a posteroanterior view with detector doses of 2.5 and 1.25 microGy, respectively. The CsI/a-Si active-matrix imager had a panel-size of 43 x 43 cm, a matrix of 3 x 3k, and a pixel-pitch of 143 microm. Hard copies were presented in a random order to eight independent observers, who rated image quality according to six subjective quality criteria. Statistical significance of differences was evaluated with Student's t test for paired samples (confidence level, 95%). Digital radiographs with 2.5 and 1.25 microGy were superior to conventional images regarding all quality criteria. Statistically significant differences were observed for five of six criteria at a detector dose of 2.5 microGy and for only one quality feature at 1.25 microGy. Flat-panel digital imagers based on CsI/a-Si technique have the potential to replace conventional systems and might allow a reduction of radiation dose by 50% without loss of image quality.
PURPOSE: To assess the diagnostic performance of an active-matrix flat-panel x-ray detector for reduced-dose imaging of simulated arthritic lesions. MATERIALS AND METHODS: A digital x-ray detector based on cesium iodide and amorphous silicon technology with a panel size of 43 x 43 cm, matrix of 3,000 x 3,000 pixels, pixel size of 143 micrometer, and digital output of 14 bits was used. State-of-the-art screen-film radiographs were compared with digital images obtained at doses equivalent to those obtained with system speeds of 400, 560, and 800. The phantom was composed of a human hand skeleton on an acrylic plate with drilled holes simulating bone erosions of different diameters and depths. Results of four independent observers were evaluated with receiver operating characteristic curve analysis. RESULTS: The cesium iodide and amorphous silicon detector resulted in better diagnostic performance than did the screen-film combination, with the dose being the same for both modalities (P <.05). For digital images obtained at reduced doses, no significant differences were found. CONCLUSION: The improved diagnostic performance with digital radiographs obtained with the cesium iodide and amorphous silicon detector suggests that this detector technology holds promise in terms of dose reduction for specific diagnostic tasks, without loss of diagnostic accuracy.