Stent appearance at contrast-enhanced MR angiography: in vitro examination with 14 stents.

PURPOSE: To evaluate signal intensity changes influencing assessment of stent patency at contrast material-enhanced magnetic resonance (MR) angiography. MATERIALS AND METHODS: By using an in vitro model, 14 stents-nine nitinol, one tantalum, two stainless steel, and two cobalt alloy-were investigated regarding their appearance at MR imaging. A vascular phantom consisting of tubes filled with 2.00 mmol/L gadopentetate dimeglumine in saline solution was studied in different orientations within the magnetic field. Imaging was performed with a fast three-dimensional gradient-echo sequence (4. 70/1.89 [repetition time msec/echo time msec]). Relative signal intensity reduction within the stents and the degree of artificial narrowing of the stent lumen were calculated. RESULTS: The stent lumen was visible within 13 stents. A total signal void inside the stent lumen appeared in only one cobalt alloy stent. Artificial narrowing of the diameter was less than 33% in 10 of 14 stents. The tantalum stent and four nitinol stents seemed best suited for contrast-enhanced MR angiography. A bandlike artifact occurred at the ends of the stents when positioned along the readout direction. CONCLUSION: To differentiate between artifacts and stenoses, knowledge of the degree of signal intensity reduction and artificial lumen narrowing within vascular stents is essential. Stent geometry, relative orientation to the magnetic field, and alloy composition influence signal intensity alteration within the stent lumen.

Contrast Media↗

Time-resolved contrast-enhanced MR angiography of renal artery stenosis: diagnostic accuracy and interobserver variability.

OBJECTIVE: The purpose of this study was to evaluate diagnostic accuracy and interobserver variability of time-resolved three-dimensional gadolinium-enhanced MR angiography in the detection of renal artery stenosis in comparison with intraarterial digital subtraction angiography as the standard of reference. SUBJECTS AND METHODS: Forty consecutive patients (age range, 25-81 years; mean, 62.9 +/- 11.9 years) with suspected renal artery stenosis underwent intraarterial digital subtraction angiography and gadolinium-enhanced MR angiography, performed on a 1.5-T system with fast low-angle shot three-dimensional imaging (3.8/1.49 [TR/TE], 25 degrees flip angle, 10-sec acquisition time, and 1.5-mm partition thickness). Three time-resolved phases were obtained in a single breath-hold. Digital subtraction angiography and gadolinium-enhanced MR angiography were evaluated by four observers who studied 80 main renal arteries and 19 accessory vessels to evaluate the degree of stenosis. A stenosis reducing the intraarterial diameter by more than 50% was regarded as hemodynamically significant. Interobserver variability was calculated. RESULTS: Only one gadolinium-enhanced MR angiography study was not of diagnostic quality, as a result of failure of the power injector. All main branches were of diagnostic quality in 38 (97.4%) of the remaining 39 gadolinium-enhanced MR angiography studies. Seventeen (89.5%) of 19 accessory renal arteries were depicted with gadolinium-enhanced MR angiography. The overall sensitivity for significant stenoses was 92.9%. The overall specificity was 83.4%, and the overall accuracy was 85.9%. Interobserver variability of gadolinium-enhanced MR angiography exceeded that of digital subtraction angiography. CONCLUSION: Time-resolved three-dimensional gadolinium-enhanced MR angiography is a useful noninvasive method of screening suspected renal artery stenosis because of its easy application, short examination time, and high sensitivity despite of its higher interobserver variability.

Adult↗

Analysis of the availability and completeness of previous radiological examinations related to plain films.

PURPOSE: To evaluate the availability and completeness of previous radiological examinations. MATERIAL AND METHODS: Seven different types of examinations were analysed separately: 1) chest examinations, 2) bedside chest examinations, 3) skeletal examinations, 4) angiographic examinations, 5) mammographic examinations, 6) CT examinations, and 7) MR examinations. A retrospective part of the study covered the calendar year 1997, while a prospective part referred to 1998. The sample size in each modality and each part of the study was 100 observations, resulting in a total number of 1,400 examinations. RESULTS: The average availability and completeness of radiographs in the retrospective analysis was 96.9% in 1997. The average availability and completeness of radiographs in the prospective analysis was 85.5% for the year 1998. This applied to necessary previous examinations of the same or different modality irrespective whether the examination was conducted internally or externally. CONCLUSION: The real loss rate of radiographs derived from the retrospective investigation was 3.1%. The prospective part of the study showed that 14.5% of the required previous internal and external examinations of the same or different modality were not available completely and in time to the examining radiologist.

Humans↗

Idiopathic hypertrophic cranial pachymeningitis associated with an orbital pseudotumor.

We report a case of idiopathic hypertrophic cranial pachymeningitis (IHCP) associated with an orbital pseudotumor and granulocytic thyroiditis of unknown origin. The patient suffered from progressive and finally complete loss of visual acuity, as well as from multiple cranial nerve dysfunctions. Medical treatment and radiation therapy were not beneficial. As reported in the literature, the CT and MRI findings of IHCP were non-specific; thus, diagnosis had to be made by exclusion and open biopsy was required. An inflammatory pseudotumor of the orbit is rarely found in patients with IHCP. Thyroiditis has not yet been reported in the context of IHCP. The patient also suffered from anosmia, which is an unusual feature of IHCP.

Autoimmune Diseases↗

[Contrast medium-enhanced MR angiography of the pelvic and leg vessels with an automated table-feed technique].

PURPOSE: To evaluate contrast enhanced magnetic resonance angiography (ceMRA) with an automated table-feed technique in patients with arterio-occlusive disease for imaging of the pelvic and peripheral arteries. METHODS: Twenty-two patients underwent three-dimensional gadolinium-enhanced MR angiography in a three-step automatic table-feed technique on a Magnetom Symphony operating at 1.5 Tesla. Maximum intensity projection images (MIP) were generated from the subtracted and original studies. Image quality and venous contrast were evaluated by two groups of observers. 304 vessels (17 patients) were compared with DSA as the standard of reference. RESULTS: All examinations were performed without any technical problems. Diagnostic quality of the MIP of subtracted data sets was superior to that of the unsubtracted images. Venous overlay was 61% in the lower leg. In a total of 599 observations, a sensitivity of 96% (95%, 82%) and a specificity of 87% (88%, 99%) were high compared to DSA in the detection of significant stenoses > or = 50% (> or = 75%, occlusions). Interobserver correlation was good (linear correlation 0.9). CONCLUSION: Stepping-table digital subtraction contrast enhanced MRA is a promising technique in the diagnosis of peripheral arterio-occlusive disease.

Aged↗

[Digital flat image detector technique based on cesium iodide and amorphous silicon: experimental studies and initial clinical results].

PURPOSE: Experimental and clinical evaluation of a digital flat-panel X-ray system based on cesium iodide (CsI) and amorphous silicon (a-Si). METHODS: Performance of a prototype detector was compared with conventional screen-film radiography (SFR) using several phantom studies. Foreign bodies, fractures, osteolyses, and pulmonary lesions were analyzed. Additionally, 120 patients were studied prospectively, resulting in 400 comparative X-ray studies. The flat-panel detector was exposed with standard dose and with a dose reduction of up to 75%. Detector size was 15 x 15 cm, pixel matrix was 1 x 1 k with a pixel size of 143 microns. Modulation-transfer function was determined to be 18% at the maximum spatial resolution of 3.5 lp/mm. RESULTS: The diagnostic results achieved with the digital detector were similar to those of conventional SFR, even at reduced radiation exposure. A potential for dose reduction was observed: 50% with respect to osteoarthrosis and fractures, and 75% for determining bony alignment. DISCUSSION: This new technology can be used in thoracic and skeletal radiography. A significant dose reduction is possible, depending on the suspected disease.

Animals↗

[Chronic, pseudocystically altered splenic hematoma as the cause of left-sided chest pain: successful therapy using alcohol instillations].

HISTORY AND CLINICAL FINDINGS: A 26-year-old man was admitted urgently because of breathing-related pain in the left thorax. This pain had started 3 months before, but had at first improved spontaneously. He had lost 13 kg during those weeks and had no recollection of any injury. Physical examination was unremarkable except for slight pain on upper-abdominal pressure and a palpably enlarged spleen. INVESTIGATIONS: All laboratory tests were normal, including the Quick value (100%), partial thromboplastin time (38 sec) and hemoglobin (14.2 g/dl). Chest radiogram showed a high left diaphragm. Abdominal sonography revealed a 12 x 10 cm moderately echogenic tumour in the spleen, extending from the splenic hilus to the upper splenic pole. Contrast-enhanced computed tomography demonstrated a hypodense tumour from which 300 ml of old blood were removed by needle puncture. Biopsy of the wall of the haematoma revealed pseudocystic transformation. TREATMENT AND COURSE: The pseudocyst again filled with blood in a few days. A drain was inserted and remained for 32 days. Six installations of alcohol achieved complete obliteration of the cystic haematoma, which did not recur. CONCLUSION: Splenic haematoma should be considered in the differential diagnosis of pain in the lower left thorax, even in the absence of a history of injury. Sonographically such a haematoma my imitate a solid tumor. Obliteration of the cavity by alcohol installation can be a successful alternative to surgical treatment.

Adult↗

Ischiogluteal bursitis mimicking soft-tissue metastasis from a renal cell carcinoma.

We report a case of ischiogluteal bursitis mimicking a soft-tissue metastasis from a renal cell carcinoma. A 66-year-old woman suffered from pain over the left buttock 6 months after she was operated on for renal cell carcinoma of the left kidney. CT of the abdomen and pelvis revealed a tumor-like lesion adjacent to the left os ischii, which was suspected to be a soft-tissue metastasis. Percutaneous biopsy revealed no evidence of malignancy, but the histopathological diagnosis of chronic bursitis.

Aged↗

Amorphous silicon, flat-panel, x-ray detector versus screen-film radiography: effect of dose reduction on the detectability of cortical bone defects and fractures.

RATIONALE AND OBJECTIVES: The purpose of this phantom study was to assess the diagnostic performance of a self-scanning, solid-state amorphous silicon (a-Si) detector in skeletal radiography using different exposure parameters. METHODS: A flat-panel detector (15 cm x 15 cm), based on a-Si technology with 143 microm x 143 microm pixel size, 1k x 1k matrix, and 12 bit digital output was used. State-of-the-art screen-film radiography (SFR; speed 400, detector dose 2.5 microGy) was compared with a-Si images taken at doses that were equivalent to a speed of 400, 800, 1,250, and 1,600, respectively. A total of 232 segments of long tubular deer-bones (femur, tibia, humerus, radius) had 110 artificial fractures and 112 cortical defects simulating osteolytic lesions. Receiver operating characteristic analysis was performed for 9,280 observations made by four independent observers. Two-tailed Student's paired t test was used for statistical analysis (95% confidence level). RESULTS: Receiver operating characteristic analysis yielded equivalent results of the a-Si and SFR system. Even at the lowest dose there were no statistically significant differences between both imaging modalities with respect to the detectability of fractures and cortical defects. CONCLUSIONS: The results of this study indicate that a-Si detector technology holds promise in terms of dose reduction in skeletal radiography without loss of diagnostic accuracy.

Animals↗

Detection of simulated chest lesions with normal and reduced radiation dose: comparison of conventional screen-film radiography and a flat-panel x-ray detector based on amorphous silicon.

RATIONALE AND OBJECTIVES: The authors compared a solid-state amorphous silicon (a-Si) detector and screen-film radiography (SFR) with regard to the detection of simulated pulmonary lesions. Evaluation of the impact of a dose reduction of 50% with this digital flat-panel detector was of special interest. METHODS: A self-scanning flat-panel detector, based on a-Si technology with 143 x 143 microm pixel size, 1 k x 1 k matrix and 12-bit digital output was used. An asymmetric state-of-the-art screen-film system was compared with a-Si images taken at the same dose as SFR-images and at a dose reduced by 50%. An anthropomorphic chest phantom was superimposed by templates containing nodules, linear structures, reticular, and micronodular opacities in a random distribution. Receiver operating characteristic analysis was performed for 23,040 observations made by four independent observers. Student's t test (95% confidence-level) was used for statistical analysis. RESULTS: Receiver operating characteristic analysis showed that a-Si images taken at the same dose as SFR-images were significantly superior to SFR with respect to the detectability of lines (P = 0.01) and micronodular opacities (P < 0.01). For the other objects and the a-Si images taken at a reduced dose, it yielded no statistically significant differences between both imaging modalities. CONCLUSIONS: The results of this phantom study indicate that a-Si detector technology holds promise in terms of dose reduction in chest radiography without loss of diagnostic accuracy compared with SFR.

Humans↗

Clinical application of a flat-panel X-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography.

OBJECTIVE: The purpose of this study was to compare images obtained with a self-scanning, flat-panel X-ray detector based on amorphous silicon technology with conventional screen-film radiographs and to evaluate the possibility of radiation dose reduction in skeletal radiography. SUBJECTS AND METHODS: One hundred twenty patients were examined prospectively using a conventional screen-film system (speed, 400; detector dose, 2.5 microGy) and a prototype digital amorphous silicon detector (simulated speed, 400 and 800, n = 120; simulated speed, 1600, n = 40). The resulting 400 images were evaluated independently by six radiologists using a subjective five-point preference scale that rated overexposure, underexposure, contrast resolution, spatial resolution, and soft-tissue presentation. Image quality was ranked on a scale from 0 to 10 according to subjective criteria. Statistical significance of differences was determined using Student's t test and confidence intervals (95% confidence level). RESULTS: Comparison of conventional radiographs with digital images revealed a statistically significant preference for the digital system for soft-tissue presentation (speed 400 and 800) and visualization of osteoarthrotic changes (speed 400). A small but statistically significant preference for conventional images was found with respect to contrast and spatial resolution when digital speed was 800 or 1600; and the visibility of arthrosis at digital speed 1600, osteolysis at digital speed 800 and 1600, and fractures at digital speed 1600. CONCLUSION: The amorphous silicon-based system with a simulated speed of 400 provided images equivalent to screen-film radiographs. For clinical tasks such as routine follow-up studies, assessment of instability, or orthopedic measurements, a radiation dose reduction of up to 75% may be possible.

Aged↗

Flat-panel x-ray detector using amorphous silicon technology. Reduced radiation dose for the detection of foreign bodies.

RATIONALE AND OBJECTIVES: The authors evaluate a new flat-panel x-ray detector (FD) with respect to foreign body detection and reduction of radiation dose compared with screen-film radiography. METHODS: Flat-panel x-ray detector is based on amorphous silicon technology and uses a 1 k x 1 k photo-detector matrix with a pixel size of 143 x 143 microns and 12-bit digital output. A thallium-dotted cesium iodide scintillation layer converts x-rays into light. An ex vivo experimental model was used to determine the detectability of foreign bodies. Foreign bodies with varying sizes were examined: glass with and without addition of lead, bone, aluminium, iron, copper, gravel fragments, and graphite. Four hundred observation fields were examined using conventional radiography (speed, 400; system dose: 2.5 microGy) as well as FD with a simulated speed of 400, 800, 1200, and 1600, corresponding to a detector dose of 2.5 microGy, 1.25 microGy, 0.87 microGy, and 0.625 microGy, respectively. Four independent radiologists performed receiver operating characteristic analysis of 8000 observations. RESULTS: Flat-panel x-ray detector with a simulated speed of 400 was significantly superior (P = 0.012) to screen-film radiography (speed, 400). At a simulated speed of 800 and 1200 FD yielded results equivalent to screen-film radiography. Flat-panel x-ray detector was significantly inferior to screen-film radiography at a simulated speed of 1600 (P = 0.012). CONCLUSIONS: Flat-panel x-ray detector technology allows significant reduction in radiation dose compared with screen-film radiography without loss of diagnostic accuracy.

Foreign Bodies↗

[Total IgE levels in the serum in dermatologic diseases].

A total of 2,951 determinations of total IgE serum levels in dermatologic patients revealed significantly elevated geometric mean values in 18 of 25 diagnostic groups. The highest IgE concentrations (geometric mean greater than 100 kU/l) were found in atopic diseases (atopic eczema, extrinsic asthma, allergic rhinitis), scabies, ichthyosis vulgaris and diseases of the prurigo group. Furthermore, total IgE was elevated in acute, chronic, and physical urticaria, in patients with immediate-type allergies, in various kinds of eczema, in patients with characteristic features of atopy (typus atopicus), in psoriasis, in pyogenic skin infections, and alopecia areata. The range of individual IgE values was wide: in all diagnostic groups individual IgE levels beneath the normal adult geometric mean of 14 kU/l were found; the maximum concentrations were 340-47,000 kU/l, thus exceeding the upper limit of 100 kU/l for individual values. Knowledge of the patient's clinical condition is a prerequisite for the diagnostic interpretation of an individual total IgE serum level.

Adolescent↗

Post-traumatic pseudocyst of the spleen: sclerotherapy with ethanol.

We report a case of successful percutaneous treatment of a chronic post-traumatic splenic pseudocyst using alcohol as the sclerosing agent. A 26-year-old man presented with a symptomatic cystic mass located in the spleen. Aspiration of 300 ml of fluid was only temporarily effective, and therefore a drainage catheter was placed 3 days later. After histopathologic and microbiologic exclusion of a malignant or infectious origin, local sclerotherapy with alcohol was performed because of recurrence after percutaneous drainage. This therapy was repeated six times within 2 weeks. Two weeks later, the remaining volume was determined to be 16 ml. Six months after treatment the cyst was no longer visible. To our knowledge this is the first case of a chronic post-traumatic splenic cyst treated with alcohol. Percutaneous sclerotherapy of a symptomatic post-traumatic splenic pseudocyst may be an alternative to surgical treatment.

Adult↗

Long-term follow-up of patients with necrotizing pancreatitis treated by percutaneous necrosectomy.

BACKGROUND/AIMS: The objective of this follow-up study was to assess the long-term outcome of patients with infected necrotizing pancreatitis treated with percutaneous catheter drainage and necrosectomy. METHODOLOGY: Nine patients (median age 44 years, range 19-69) with infected pancreatic necrosis and catheter drainage for initial treatment were evaluated after a median follow-up of 30 months (range 15-52) with respect to quality of life (pain, diarrhea, fat intolerance), morphology and endocrine and exocrine pancreatic function. RESULTS: At follow-up all 9 patients (100%) were in good general condition with respect to quality of life. Only 2/9 (22%) patients had moderate to marked changes in computed tomography. There was mild to moderate exocrine dysfunction in 5/8 (63%) patients, 2/8 (25%) patients had a severe restriction of the exocrine pancreatic function; in one patient the serum pancreoaryl test was normal. An oral glucose tolerance test was performed in 6/9 patients, with a normal result in 3/6 (50%) patients. 2/6 (33%) patients had an impaired oral glucose tolerance test with metabolic pathogenesis. One patient with diabetes in the oral glucose tolerance test had a preexisting type II diabetes requiring insulin therapy since the onset of acute pancreatitis. In 3/9 (33%) patients an oral glucose tolerance test was not performed due to known preexisting diabetes. CONCLUSIONS: Percutaneous drainage of infected necrotizing pancreatitis has given good long-term results with regard to quality of life, endocrine and exocrine pancreatic function and may be an alternative to surgical treatment.

Adult↗