PubMed Health⌕ Search

Biomedical subjects

M Voss

Publications and source records attributed to M Voss.

At least 73 records · Page 4Linked to original sources

Prospective evaluation of ultrasonography in acute colonic diverticulitis.

BACKGROUND: The clinical diagnosis of acute colonic diverticulitis (ACD) can be difficult and ultrasonography by experts is valuable in establishing the diagnosis. This prospective observational trial aimed to assess the diagnostic accuracy and clinical value of ultrasonography performed routinely by surgical residents in training. METHODS: The clinical course of 187 unselected consecutive patients admitted with suspected ACD was studied prospectively. Patients who had surgery for generalized peritonitis were excluded, leaving 143 for evaluation. Ultrasonographic findings and clinical assessment on admission were correlated with the patient's clinicopathological data and discharge diagnosis respectively. RESULTS: Of 74 patients with proven ACD (prevalence 52 per cent) the diagnosis was made by ultrasonography in 62, with an accuracy of 88 per cent, sensitivity 84 per cent and specificity 93 per cent. Ultrasonography gave a false-negative result in 12 patients (negative predictive value (NPV) 84 per cent) and there were five false-positive findings (positive predictive value (PPV) 93 per cent). The final diagnosis in the latter five patients was colitis (two patients), caecal carcinoma (one), colonic ileus due to perforated sigmoid carcinoma (one) and suppurative pyosalpingitis with involvement of the sigmoid colon (one). The accuracy of clinical evaluation on admission was 71 per cent (sensitivity 82 per cent, specificity 55 per cent, PPV 72 per cent, NPV 68 per cent); however, in only 53 per cent of patients was the diagnosis considered clinically unequivocal. CONCLUSION: Ultrasonography is a useful and valid modality for imaging ACD and its differential diagnoses in the hands of sonographically trained surgeons. It is especially helpful when the clinical findings are equivocal.

Acute Disease↗

Symptom reporting in cancer patients: the role of negative affect and experienced social stigma.

BACKGROUND: Recent research suggests that patients' appraisal of somatic symptoms is more closely related to emotional variables (particularly negative affect) than to their actual health as determined by external criteria. METHODS: Sixty surgical cancer patients who at the time of a routine follow-up examination filled out the European Organization for Research and Treatment of Cancer (EORTC) quality of life questionnaire-C30, which included a positive/negative affect scale and a scale tapping into experienced social stigma. Patients' health status was determined in two ways: the examining physician gave a global judgement on a standardized scale at the end of the examination, and an additional two external physicians later rated the patients based on the findings listed in the medical record. RESULTS: Patients' reports of somatic symptoms were strongly correlated with two measures of negative affect (r = 0.75 and r = 0.65, respectively) and with experienced social stigma (r = 0.51). In contrast, the correlations between reported symptoms and the examining or external physicians' ratings were considerably weaker (r = 0.31 and r = 0.19). According to a multiple linear regression with 6 predictors, negative affect was the best single predictor of symptom reporting (beta = 0.68; P < 0.001) and global quality of life (beta = 0.48; P < 0.001). Factor analysis yielded a dimension of somatopsychosocial distress that accounted for 44.1% of the variance and is comprised of reported symptoms (factor loading = 0.86), negative affect (0.90 and 0.82), experienced social stigma (0.74), and global quality of life (0.70). Physicians' ratings and positive affect constituted two additional separate factors. CONCLUSIONS: Cancer patients' reporting of somatic symptoms by means of a standardized quality of life questionnaire is closely related to emotional and social distress and is not equivalent to health status as determined from a clinical perspective. Researchers and practitioners have to be aware of this fact when interpreting quality of life data. Furthermore, negative affect deserves attention as an important signal for intervention in tumor follow-up programs.

Abdominal Neoplasms↗

Unsharp masking of low-dosed digital luminescence radiographs: results of a receiver operating characteristics analysis.

The extent to which the diagnostic performance of low-dosed storage phosphors can be improved by suitable image postprocessing was investigated. Storage phosphor radiographs and conventional 200- and 400-speed screen-film combinations of an anthropomorphic chest phantom with simulated nodules and linear structures were compared. The detection of test bodies was determined in a ROC analysis based on 16200 individual observations. The two analog screen-film systems did not differ significantly. As far as the storage phosphor radiographs are concerned, a higher diagnostic performance was achieved with a large filter kernel (S 40) whereas small filter kernels and edge-enhanced imaging modes reduced the detection of detail. The image quality of low-dosed storage phosphors is thus similar to high-amplification screen-film combinations if large filter kernels are used in postprocessing of the image.

Acrylic Resins↗

A Simple, High-Precision, High-Sensitivity Tracer Assay for N(inf2) Fixation.

We describe a simple, precise, and sensitive experimental protocol for direct measurement of N(inf2) fixation using the conversion of (sup15)N(inf2) to organic N. Our protocol greatly reduces the limit of detection for N(inf2) fixation by taking advantage of the high sensitivity of a modern, multiple-collector isotope ratio mass spectrometer. This instrument allowed measurement of N(inf2) fixation by natural assemblages of plankton in incubations lasting several hours in the presence of relatively low-level (ca. 10 atom%) tracer additions of (sup15)N(inf2) to the ambient pool of N(inf2). The sensitivity and precision of this tracer method are comparable to or better than those associated with the C(inf2)H(inf2) reduction assay. Data obtained in a series of experiments in the Gotland Basin of the Baltic Sea showed excellent agreement between (sup15)N(inf2) tracer and C(inf2)H(inf2) reduction measurements, with the largest discrepancies between the methods occurring at very low fixation rates. The ratio of C(inf2)H(inf2) reduced to N(inf2) fixed was 4.68 (plusmn) 0.11 (mean (plusmn) standard error, n = 39). In these experiments, the rate of C(inf2)H(inf2) reduction was relatively insensitive to assay volume. Our results, the first for planktonic diazotroph populations of the Baltic, confirm the validity of the C(inf2)H(inf2) reduction method as a quantitative measure of N(inf2) fixation in this system. Our (sup15)N(inf2) protocols are comparable to standard C(inf2)H(inf2) reduction procedures, which should promote use of direct (sup15)N(inf2) fixation measurements in other systems.

Journal Article↗

Effects of varying filter kernel sizes on the image quality of interstitial lung diseases.

PURPOSE: The aim of the study was to optimize the postprocessing of digital luminescence radiographs of interstitial infiltrates of the lung. MATERIAL AND METHODS: Ninety-seven patients with established diseases of the lung parenchyma were examined: 514 pathological details were investigated, using a 200-speed screen-film system and a storage phosphor plate. In digital postprocessing, the size of the filter kernel (S) varied between S 5 and S 70. Based upon 32896 individual evaluations, the image quality was evaluated in multifactorial variance analyses. RESULTS: The digital standards were significantly inferior to the tested screen-film system. The large filter kernel S 70 and the small filter kernels S 5 and S 10, as well as an algorithm for edge enhancement, showed selective advantages in the depiction of nodular or small linear structures. For micronodular and linear structures, kernel sizes of S 20 and S 40 produced equally good results (p > 0.05). CONCLUSION: Whenever optimized postprocessing is involved, storage phosphor radiography is equal to a modern screen-film system and can be substituted for the latter without any loss of image quality; this is especially valid for the imaging of interstitial infiltrates of the lung.

Female↗

ROC-analysis of detection performance by analogue and digital plain film systems in chest radiography.

PURPOSE: To compare the performances of 4 imaging systems in the diagnostic radiology of the chest: an asymmetric screen-film combination (a-SFC); a conventional screen-film combination of speed class 200 (SFC); a screen-film combination of speed class 200 with an aluminium lung filter; and digital luminescence radiographs (DLR). MATERIAL AND METHODS: Object detectability studies were carried out using an anthropomorphic chest phantom. The images were obtained under standard exposure conditions at 125 kVp. The detection performance of the various systems was evaluated by receiver operating characteristic (ROC) analysis on the basis of a total of 12,240 observations. RESULTS: In the overall evaluation the a-SFC and the SFC plus lung filter received equally high ratings of 0.878+/-0.018 and 0.860+/-0.21, respectively (p>0.05). There was no significant difference between the 200-speed SFC and the storage phosphor radiographs. In the mediastinum all the tested systems were clearly superior to the 200-speed SFC (p<0.05) while in the lung fields the 200-speed SFC received a high rating of 0.866+/-0.026. The a-SFC had slight advantages over the SFC plus lung filter and the 2 digital imaging modes (p>0.05). CONCLUSION: The a-SFC and the digital luminescence radiographs provide a significant gain in diagnostic information in the mediastinum without diminishing detail detectability in the lung fields and without additional radiation exposure.

Filtration↗

Patients who reattend after head injury: a high risk group.

OBJECTIVE: To assess risk factors for important neurosurgical effects in patients who reattend after head injury. DESIGN: Retrospective study. SUBJECTS: 606 patients who reattended a trauma unit after minor head injury. MAIN OUTCOME MEASURES: Intracranial abnormality detected on computed tomography or the need for neurosurgical intervention. RESULTS: Five patients died: two from unrelated causes and three from raised intracranial pressure. On multiple regression analysis the only significant predictor for both abnormality on computed tomography (14.4% of reattenders) and the need for operation (5% of reattenders) was vault fracture seen on the skull radiograph (P < 10(-6)); predictors for abnormal computed tomogram were a Glasgow coma scale score < 15 at either first or second attendance (P < 0.0001) and convulsion at second attendance (P < 0.05); predictive for operation only was penetrating injury of the skull (P < 10(-6)). On contingency table analysis these associations were confirmed. In addition significant associations with both abnormality on computed tomography and operation were focal neurological abnormality, weakness, or speech disturbance. Amnesia or loss of consciousness at the time of initial injury, personality change, and seizures were significantly associated only with abnormality on computed tomography. Headache, dizziness, nausea, and vomiting were common in reattenders but were found to have no independent significance. CONCLUSIONS: All patients who reattend after head injury should undergo computed tomography as at least 14% of scans can be expected to yield positive results. Where this facility is not available patients with predictors for operation should be urgently referred for neurosurgical opinion. Other patients can be readmitted and need referral only if symptoms persist despite symptomatic treatment or there is neurological deterioration while under observation. These patients are a high risk group and should be treated seriously.

Adult↗

Isolation of mammalian cell mutants that are X-ray sensitive, impaired in DNA double-strand break repair and defective for V(D)J recombination.

The Chinese hamster lung V79-4 cell line was infected with a Moloney murine leukemia retrovirus and the infected cells were subsequently screened for mutants that were sensitive to X-rays using a toothpicking/96-well replica plating technique. Four independent mutants that were sensitive to X-irradiation (sxi-1 to sxi-4) were isolated from 9000 retrovirally infected colonies. A pulse-field gel electrophoresis (PFGE) assay demonstrated that all of the sxi mutants were impaired in DNA double-strand break (DSB) repair, thus providing a molecular explanation for the observed X-ray sensitivity. Interestingly, additional PFGE experiments demonstrated that for any given X-ray dose all of the mutants incurred more DNA DSBs than the parental V79-4 cell line indicating there may be some inherent fragility to sxi chromosomes. Cross-sensitivity to other DNA-damaging agents including bleomycin, mitomycin C and methyl methanesulfonate indicated that sxi-2, sxi-3 and sxi-4 appear to be specifically hypersensitive to genotoxic agents that cause DNA DSBs, whereas sxi-1 appeared to be hypersensitive to multiple types of DNA lesions. Lastly, in preliminary experiments all of the sxi mutants demonstrated an inability to carry out V(D)J recombination, a somatic DNA rearrangement process required for the assembly of lymphoid antigen receptor genes. Thus, the sxi cell lines have interesting phenotypes which should make them valuable tools for unraveling the mechanism(s) of DNA DSB repair and recombination in mammalian cells.

Animals↗

[ROC analysis in post-processing of image data in digital thoracic radiography].

PURPOSE: To examine the extent to which digital luminescence radiography (DLR) can be used for the imaging of pulmonary nodules and interstitial lung disease in chest radiography without any loss of image quality. Additionally: to examine whether post-processing of image data can optimise the recognizability of varied image details. MATERIALS AND METHODS: Detail perceptibility studies were performed on an anthropomorphic thorax phantom with simulated nodules and small linear and reticular details. Under standard conditions, digital luminescence radiographs were obtained in 7 different image modes, and these were compared with a 200-speed screen-film system. The detection of these systems was evaluated in an ROC analysis on the basis of 19,200 individual observations. RESULTS: Edge enhancement or application of high-frequency-enhancing small filter kernels (S 5) slightly improves the detection of linear structures; however, the illustration of nodular details is markedly reduced. Larger filter kernels (S 20, S 40) make a definitive detection possible--not only of circular, but also of linear details. CONCLUSIONS: Storage phosphor radiographs are equal to the tested analog screen-film-system. The optimization of post-processing can be helpful in the prevention of routine multiple documentations.

Adult↗

[The use of an asymmetric film-screen combination for the imaging of round pulmonary foci].

PURPOSE: To examine the diagnostic advantages of an asymmetric film-screen system (a-FSS) compared to a conventional 200-speed FSS with and without anatomical lung filter. METHODS: Standard radiographs were obtained from an anthropomorphic chest phantom with simulated pulmonary nodules. The existence or non-existence of nodules was assessed in 7344 individual observations. The results were evaluated using ROC analysis. RESULTS: In an overall evaluation the a-FSS with an ROC area of 0.873 +/- 0.018 was not significantly superior (p > 0.05) to the lung filter but significantly superior (p < 0.05) to the 200-speed FSS. In the mediastinum the a-FSS and the lung filter were significantly superior (p < 0.05) to the 200-speed FSS. In the lung areas the 200-speed FSS and the a-FSS attained equivalent results (p > 0.05), whereas the lung filter was rated significantly lower (p < 0.05). CONCLUSIONS: Asymmetric FSS improves chest diagnostics, because it yields significantly more diagnostic information in the mediastinum using equivalent x-ray exposure without reducing the image quality in the lung areas in respect of simulated pulmonary nodules.

Evaluation Studies as Topic↗

The influence of VDT work on musculoskeletal disorders.

Relationships between visual display terminal (VDT) use and musculoskeletal problems were examined in a group of 353 office workers, using data from medical and workplace investigations as well as questionnaires. There were no general differences between VDT and non-VDT users as to the occurrence of muscle problems. Combinations of specific VDT work situations such as data entry work or work with a VDT for more than 20 h/week and the presence of some other factors were, however, associated with excess risks of certain muscle problems. The extraneous factors involved in the definitions of such risk groups were: use of bifocal or progressive glasses at a VDT; stomach-related stress reactions; limited rest break opportunity; repetitive movements; non-use of lower arm support; and possibly the vertical position of the keyboard; and presence of specular glare.

Cohort Studies↗

Musculoskeletal disorders among visual display terminal workers: individual, ergonomic, and work organizational factors.

A number of individual, ergonomic, and organizational factors of presumed importance for the occurrence of musculoskeletal disorders were investigated in a group of 260 visual display terminal (VDT) workers. The cross-sectional study utilized medical and workplace investigations as well as questionnaires. The results were subjected to a multivariate analysis in order to find the major factors associated with various upper-body muscular problems. Several such factors were identified for each investigated type of musculoskeletal problem. Some were related to the individual: age, gender, woman with children at home, use of spectacles, smoking, stomach-related stress reactions, and negative affectivity. Organizational variables of importance were opportunities for flexible rest breaks, extreme peer contacts, task flexibility, and overtime. Identified ergonomic variables were static work posture, hand position, use of lower arm support, repeated work movements, and keyboard or VDT vertical position.

Adult↗

[ROC analysis of image quality in digital luminescence radiography in comparison with current film-screen systems in mammography].

AIM: To compare in mammography the image quality of digital luminescence radiography (DLR) to that of usual film screen mammography and xeromammography. MATERIALS AND METHODS: Three single emulsion film-screen combinations, one double coated high resolution film and xeroradiography, were tested for this purpose. In our phantom study the detectability of microcalcifications, fibrils and low contrast details were first of all studied separately. Image processing techniques were, for example, contrast variation by grey scale level windowing, "unsharp mask" filtering and regulatable edge enhancement. Phantom images were made and then the image quality was evaluated by observer performance study using a receiver operating characteristic (ROC analysis). RESULTS: Best results in respect of detection of microcalcifications and fibrils were found in xeroradiography, luminescent image plate and double-coated film-screen combination. These systems showed more favourable ROC curves than the single emulsion film-screen combinations. CONCLUSIONS: Our results indicate that image quality of digital images in the field of image processing is equal to that of conventional mammographic techniques and partially superior to detection of low contrast details.

Breast Neoplasms↗

[Long-term results of the modified Eden-Hybinette operation for treatment of recurrent shoulder dislocation].

In a retrospective study we evaluated the long-term results of a modified Eden-Hybinette procedure in 76 patients. Besides stability, function, and subjective complaints, we documented in particular the degenerative changes of the joint. Subjective findings revealed excellent or good results in 68.5% of cases. In 20% of the patients the results were fair and in 11.5% poor. Some 66% of the patients had not subjective feeling of joint restriction. However, 25% complained of some and 9% of severe joint restriction. The overall recurrence rate was 13.9%. In patients with atraumatic dislocation the recurrence rate was 12%, in patient with voluntary dislocation it was 50%, and in posttraumatic instabilities the recurrence rate was 4.8%. The Rowe score showed 40% excellent and good results. The poor results were among the patients with redislocation, instabilities with subluxation, and secondary degenerative joint disease with concomitant pain and limitations in the range of motion. In patients with voluntary instabilities the poor results were in the group of redislocators, whereas in the posttraumatic group poor results were mainly due to degenerative joint disease. In 80% of the patients with bone block complications, secondary degenerative joint disease developed. Considering the relatively high recurrence rate and the amount of secondary degenerative joint disease after this procedure, we do not recommend this as a routine procedure for shoulder stabilisation.

Adult↗

Traumatic duodenal haematoma in children.

Over a 15-year period, 967 children presenting to Red Cross War Memorial Children's Hospital with blunt abdominal trauma included nine cases in whom traumatic intramural duodenal haematomas were diagnosed on clinical and radiological grounds. Motor vehicle collisions were the commonest cause of injury. Review of these nine cases and their management confirms the efficacy of non-operative treatment and that laparotomy should be reserved for only those children with additional intra-abdominal injuries, or where the diagnosis remains in doubt.

Accidents, Traffic↗

Prophylactic reoperation for strut fractures of the Björk-Shiley convexo-concave heart valve.

Outlet strut fracture of the Björk-Shiley Convexo-Concave (C/C) heart valve is the current paradigm of structural failure of mechanical heart valve prostheses. The estimated risk of fracture for C/C valves varies from 0.02% to 2.5% per patient-year, depending on valve size, opening angle, date of manufacture and position as a mitral or aortic replacement. This report examines our experience with 396 implants, comprising 346 C/C 60 degrees valves and 50 C/C 70 degrees valves. The 30-day mortality was 1.8%. Through April 1993, mean follow up was 8.9 years, incorporating 2971 patient-years and knowledge of the current status of 91.5% (356/389) of operative survivors. Late mortality was 3.7% per patient-year, including one 60 degrees and one 70 degrees outlet strut fracture. To evaluate the risk of semi-elective valve re-replacement at our institution, we reviewed the results of isolated re-replacements of failing or incipiently failing bioprostheses in 65 patients who had no serious co-morbidity and who were NYHA Class III or lower immediately before the procedure. The 30-day mortality was 4.6% and the overall serious morbidity rate was 10.8%, necessitating six repeat reoperations. When these factors were balanced against the life expectancy and general status of five patients with large-size, higher-fracture-risk 70 degrees C/C valves, it was concluded that only two patients remained possible reoperation candidates. Consideration for re-replacement of a normally functioning C/C heart valve should take into account institution-specific experience because structural failure remains a low risk compared to valve-related complications engendered by reoperation.

Adult↗

[Primary diagnosis of osseous carpal area injuries--a comparison of conventional examination methods with digital luminescence radiography].

Despite recent progress in improving diagnostic methods carpal bone lesions are still a major problem of primary diagnosis. Diagnostic imaging with digital luminescence radiography (DLR) allows the reliable presentation of traumatologically relevant carpal structures. In this study on 39 patients with suspected carpal bone injuries individually worked over DLR images were superior to "standard" DLR and conventional X-ray film/screen images. Though "standard" DLR images were inferior to film images edge-enhanced DLR images showed definite advantages in the demonstration of soft tissues. Fractures undetectable in conventional X-rays could not be recognized by digital imaging. In our experience bone-scanning remains the most reliable method for definite exclusion of carpal bone fractures after standard and digital X-ray methods are exhausted.

Adolescent↗

[Are high-intensifying film-screen combinations suitable for the detection of fine interstitial lung changes? The results of a ROC study with an anthropomorphic thorax phantom].

Exposures of an anthropomorphic thorax phantom in posteroanterior projection were made using a focus-film distance of 200 cm and 125 kV with film-screen combinations in class 200 (Curix RP 1L/MR 200) and class 400 (Curix ST-L/Regular). Pathomorphological structures of the lung parenchyma of fine nodular, linear and reticular types were simulated by suitable materials. A ROC analysis including a t-test showed no significant difference in the evaluation of these structural details (p > 0.05). In order to describe image quality for the two film-screen systems, density curves, sigma D-curves and modulation transfer function (MTF) were determined. The only demonstrable difference was reduced MTF of 10-15% for the higher intensification film-screen combination with a resulting poorer resolution of 3.7 l/mm (for the 400 system) compared with 4.3 l/mm for the 200 system.

Evaluation Studies as Topic↗