PubMed Health⌕ Search

Biomedical subjects

M W Nielen

Publications and source records attributed to M W Nielen.

6 recordsLinked to original sources

Screening for anabolic steroids and related compounds in illegal cocktails by liquid chromatography/time-of-flight mass spectrometry and liquid chromatography/quadrupole time-of-flight tandem mass spectrometry with accurate mass measurement.

Findings of illegal hormone preparations such as syringes, bottles, cocktails, and so on, are an important information source for the nature of the current abuse of anabolic steroids and related compounds as growth-promoting agents in cattle. A new screening method for steroids in cocktails is presented based on liquid chromatography (LC) with diode-array UV-absorbance detection and electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS). Accurate mass measurements were performed at a mass resolution of 4000 using continuous introduction of a lock mass through a second (electro)sprayer. Similar experiments were carried out using dual-sprayer quadrupole time-of-flight mass spectrometry (ESI-QTOFMS/MS) at a mass resolution of 10 000 with data-dependent MS/MS acquisition; i.e. beyond an intensity threshold for the [M + H](+) ions, MS/MS spectra were automatically acquired at three different collision energies. Elemental compositions were calculated for precursor and product ions and it is shown that the combined information from LC retention behavior, UV spectra, elemental compositions, and accurate mass MS/MS spectra yield a fast impression of the steroids present in the complex mixture. Using a new software tool for structure elucidation of MS/MS spectra, an additional non-steroidal additive was identified as well.

Anabolic Agents↗

Screening of amphetamines by gradient microbore liquid chromatography and pre-column technology.

Amphetamine-type drugs with a wide polarity range have been screened in both human and horse urine using on-line pre-concentration on pre-columns packed with hydrophobic and cation-exchange sorbents in series and gradient microbore high-performance liquid chromatography. The underivatized amphetamines were identified by UV detection at 210 nm. The method has potential for the automated liquid chromatographic screening of amphetamines in urine, e.g., for doping control.

Amphetamines↗

Fully automated sample handling system for liquid chromatography based on pre-column technology and automated cartridge exchange.

The design of an automated cartridge exchange module for on-line sample handling in liquid chromatography is described. When combined with a low-cost purge pump, a solvent selection valve and an auto-sampler, a fully automated sample handling system is obtained. Samples are sorbed on a disposable cartridge packed with 40 micron octyl-bonded silica, purged for clean-up and eluted on-line to the analytical column. Unattended operation of the system is demonstrated for various examples, i.e., the determination of anti-epileptic drugs in serum, an anti-cancer drug in plasma, barbiturates in urine, phenylurea herbicides in river water and caffeine in a soft drink.

Autoanalysis↗

Handling of environmental and biological samples via pre-column technologies.

Sample handling is still a weak point in chromatography and in analytical chemistry in general. One consideration is the automation potential of new procedures. Solid-liquid extraction techniques in combination with pre-column technology are particularly promising in this regards. The construction and geometry of pre-columns both for conventional and narrow-bore HPLC are of major importance, since band broadening should be kept at a minimum for an optimal functioning of the analytical system. The various operations that can be carried out with such a pre-column are trace-enrichment, clean-up of the sample which depends on the type of adsorbents used in the precolumn, i.e., polar or apolar materials, ion exchangers or metal covered surfaces, etc., protection of the analytical column, field sampling and storage of samples and as a substrate for on-column chemical derivatizations. These various operations are demonstrated with practical examples from the fields of environmental and biological analysis. The selectivity can be further enhanced by coupling pre-column technology with selective detection models such as diode array UV, electrochemical or fluorescence detection. This enables the construction of optimal and integrated analysis systems which are fully automated and microprocessor controlled. They can also be made compatible with miniaturized LC-technology.

Autoanalysis↗