A novel method to obtain microtensile specimens minimizing cut flaws.

Cutting procedures conventionally used for microtensile specimens' preparation induce mechanical stress and attrition, leading to cracks in dental structure. Enamel is mainly affected due to its high module of elasticity and brittleness. As an alternative to the conventional diamond saw, a diamond wire was used for cutting. The two techniques were compared in efficacy in the preparation of two different sample shapes. Forty human molars, flattened in dentin or enamel, were used for sample preparation. After bonding procedures, resin block was built incrementally. Half of the teeth were cut using a diamond disc and the other half using a diamond wire, obtaining slabs and stick-shaped specimens. Slabs were then shaped to obtain hourglass samples. Five samples from each subgroup were randomly selected for Scanning electron microscopy (SEM) analysis. Remaining samples underwent microtensile test and the results were analyzed, including/excluding premature failures (pf), with three-way ANOVA and Tukey test, performed separately, by substrate. On dentin, only the exclusion of pf showed a significant higher bond strength values than when pf were included (p < 0.05); however, on enamel, all factors (equipment, shape and including/excluding pf) had a significant effect on bond strength (p<0.05). The most remarkable finding from SEM was the incidence of specimens' cracks and defects when diamond blade was used. Scratches and cracks in the hourglass-shaped specimens were also detected. In both cases, enamel was more affected than dentin.

Dental Enamel↗

A simple etching technique for improving the retention of fiber posts to resin composites.

Coupling of fiber posts to composites is hampered by absence of chemical union between epoxy resins and methacrylate-based resins. This study examined a clinically feasible protocol for creating micromechanical retention on the surface of fiber posts, using hydrogen peroxide etching to remove the surface layer of epoxy resin. This was followed by silanization of the exposed quartz fibers to enhance their chemical bonding to composites. Etching with 24% H2O2 for 10 min or 10% H2O2 for 20 min produced a 50 microm thick surface zone that is depleted of epoxy resin, leaving intact, undamaged quartz fibers for silanization. Low viscosity flowable composites were employed to infiltrate this zone, to simulate the creation of hybrid layers in acid-etched dentin by dentin adhesives. Interfacial strengths were enhanced with the adjunctive use of H2O2 etching and silanization, and were probably dependent on the ability of the flowable composites to completely infiltrate this interdiffusion zone.

Barium Compounds↗

Dynamometric assessment of the mechanical resistance of porcelain veneers related to tooth preparation: a comparison between two techniques.

STATEMENT OF PROBLEM: There is little agreement regarding a palatal extension of the preparation for porcelain veneers, as it represents a more invasive technique than a preparation limited to the facial surface of a tooth. PURPOSE: The purpose of this study was to detect the stress in maxillary anterior teeth restored with porcelain veneers and compare the resistance to fracture of porcelain veneers prepared using different preparation designs. MATERIAL AND METHODS: Forty-five maxillary anterior teeth were restored with porcelain veneers and divided into 9 groups as follows: Ca, canines with no preparation; Ca-Ch, canines with palatal chamfer preparation; Ca-W, canines with window preparation; LI, lateral incisors with no preparation; LI-Ch, lateral incisors with palatal chamfer preparation; LI-W, lateral incisors with window preparation; CI, central incisors with no preparation; CI-Ch, central incisors with palatal chamfer preparation; CI-W, central incisors with window preparation. Shear-flexural fracture tests were performed. The fractured specimens were subjected to scanning electron microscope (SEM) analysis. Data were statistically analyzed with univariate analysis of variance and the Tukey post hoc test for multiple comparisons (alpha=.05). RESULTS: The following mean fracture load values (N) were recorded: Ca, 395 +/- 6; Ca-Ch, 310 +/- 8; Ca-W, 322 +/- 8; LI, 309 +/- 8; LI-Ch, 242 +/- 6; LI-W, 225 +/- 8; CI, 298 +/- 8; CI-Ch, 255 +/- 8; CI-W, 221 +/- 6. The SEM analysis showed that both adhesive and cohesive fractures were primarily concentrated at the cervical region. Statistical analysis showed that both the type of tooth and the design of the preparation significantly influenced the resistance to fracture of the restored teeth (P<.001). CONCLUSION: The chamfer preparation is recommended for central incisors, whereas the window preparation showed better results for canines. Both preparations can be adopted in the restoration of lateral incisors.

Analysis of Variance↗

Surgical closure of patent ductus arteriosus reduces the cerebral tissue oxygenation index in preterm infants: a near-infrared spectroscopy and Doppler study.

BACKGROUND: The aim of this study was to investigate the effects of patent ductus arteriosus (PDA) ligature on cerebral oxygen saturation, cerebral blood volume (CBV) and cerebral blood flow velocity by means of near-infrared spectroscopy (NIRS) and transcranial Doppler simultaneous examinations. METHODS: This is an observational study considering 16 babies of gestational age 24-34 weeks diagnosed with PDA who underwent surgical ligation. The cerebral oxygen saturation, CBV and blood gases values were obtained 35 min before ligation, so also around the 14th and 27th min after the clip's insertion. RESULTS: Cerebral oxygen saturation, measured as tissue oxygenation index (TOI), decreased significantly after PDA ligation from a basal value of 61.1 (3.8) before surgery to 56.6 (3.3) and 55.8 (2.6)%, for the 14th and 27th min, respectively (P<0.04). CBV before and after clipping was unvaried. A negative correlation was found between DeltapH and DeltaCBV after ligation (R=0.52, P=0.03), whilst a positive correlation was found between DeltaCBV and DeltaP(aCO2) (R=0.62, P=0.009). pH increased at the 27th min post-ligation. CONCLUSIONS: NIRS is a tool for obtaining information on cerebral oxygen saturation and CBV changes during surgical PDA ligation at the bedside. A fall in TOI suggests an increased oxygen extraction during PDA surgery. The lack of increase in DeltaCBV or in diastolic flow velocity show that the PDA before the clipping did not limit cerebral blood flow, the drop in TOI suggests increased oxygen consumption over the clip and the need for accurate monitoring of oxygen utilization after the surgical treatment.

Blood Flow Velocity↗

Fatigue resistance of the bond of a glass-infiltrated alumina ceramic to human dentin.

PURPOSE: To evaluate the fatigue resistance of the bond between dentin and glass-infiltrated alumina ceramic, using different luting protocols. MATERIALS AND METHODS: The null hypothesis is that the fatigue resistance varies with the luting strategy. Forty blocks of In-Ceram Alumina were prepared, and one surface of each block was abraded with 110-microm aluminum oxide particles. Then, the blocks were luted to flat dentin surfaces of 40 human third molars, using 4 different luting strategies (luting system [LS]/ceramic surface conditioning [CSC]) (n=10): (G1) [LS] RelyX-Unicem/[CSC] airborne abrasion with 110-microm Al2O3 particles; (G2) [LS] One-Step + Duo-Link (bis-GMA-based resin)/[CSC] etching with 4% hydrofluoric acid + silane agent; (G3) [LS] ED-Primer + Panavia F (MDP-based resin)/[CSC] Al2O3; (G4) [LS] Scotchbond1+RelyX-ARC (bis-GMA-based resin)/[CSC] chairside tribochemical silica coating (air abrasion with 30-microm SiOx particles + silane). After 24 h of water storage at 37 degrees C, the specimens were subjected to 106 fatigue cycles in shear with a sinusoidal load (0 to 21 N, 8 Hz frequency, 37 degrees C water). A fatigue survivor score was given, considering the number of the fatigue cycles until fracture. The failure modes of failed specimens were observed in a SEM. RESULTS: G3 (score = 5.9, 1 failure) and G4 (score = 6, no failures) were statistically similar (p = 0.33) and had significantly higher fatigue resistance than G1 (score = 3.9, 5 failures) and G2 (score = 3.7, 6 failures) (p < 0.03). SEM analysis of fractured specimens of G1 and G2 showed that almost all the failures were between ceramic and cement. CONCLUSION: The MDP-based resin cement + sandblasting with Al2O3 particles (G3) and bis-GMA-based resin cement + tribochemical silica coating (G4), both using the respective dentin bonding systems, were the best luting protocols for the alumina ceramic. The null hypothesis was confirmed.

Acid Etching, Dental↗

Adhesion between prefabricated fiber-reinforced posts and different composite resin cores: a microtensile bond strength evaluation.

PURPOSE: The aim of this study was to evaluate the bond strengths between various resin composites used as core materials (Multicore Flow, Ivoclar-Vivadent; Tetric Flow, Ivoclar-Vivadent; Filtek Flow, 3M-ESPE; Tetric Ceram, Ivoclar-Vivadent; Filtek Z250, 3M-ESPE), and an FRC post (FRC Postec Plus, Ivoclar-Vivadent) by means of the microtensile nontrimming technique. MATERIALS AND METHODS: Five experimental groups were used. For the microtensile nontrimming technique, 45 to 50 beam-shaped specimens per group were obtained from cylinders of core material, which had been built up around the post by progressively adding small increments of composite resin. Each specimen was loaded in tension until failure at either one of the two post/core interfaces present in each stick. The differences in interfacial bond strength amongthe groups were tested for statistical significance with the one-way ANOVA test, followed by the Dunnett test for post-hoc comparisons. RESULTS: The measured bond strengths in MPa were 17.29 +/- 6.02 for FRC+MultiCore Flow, 16.37 +/- 6.92 for FRC+Tetric Flow, 13.14 +/- 5.35 for FRC + Filtek Flow, 12.38 +/- 4.34 for FRC + Tetric Ceram, and 10.75 +/- 5.43 for FRC + Filtek Z250. The statistical analysis revealed that MultiCore Flow achieved significantly higher bond strengths than Filtek Flow (p = 0.03), Tetric Ceram (p < 0.001), and Filtek Z250 (p < 0.001). The bond strength of Tetric Flow was significantly higher than that of Filtek Z250 (p = 0.003). CONCLUSION: For core buildup on a fiber post, dual-cure composites appear to be preferable to light-curing composites.

Acid Etching, Dental↗

Effect of dentin adhesives used as sealers and provisional cementation on bond strength of a resin cement to dentin.

PURPOSE: To evaluate the effects of dentin adhesives employed as resin sealers and provisional cementation on the bond strengths of a resin cement to dentin. METHODS: A two-step etch-and-rinse adhesive (Excite DSC--Group 1) and two-step self-etch adhesive (AdheSE--Group 2) were applied to exposed dentin surfaces prepared from human molars (N=4). Water was used instead of a resin sealer in control Groups 3 and 4. A eugenol-free provisional cement (except for Group 4) was applied to the treated surfaces. After storing in distilled water for 1 week, the provisional cement was removed and cylindrical composite blocks were luted with a resin cement (Variolink II). 0.9 x 0.9 mm sticks were produced from these luted specimens for microtensile bond testing and SEM examination. RESULTS: One-way ANOVA revealed that neither the resin sealer nor the temporary eugenol-free cement had a negative effect on the final bond strength (P> 0.05). Mixed failures were predominantly identified from SEM.

Acrylic Resins↗

An investigation of the interfacial strengths of methacrylate resin-based glass fiber post-core buildups.

PURPOSE: To assess the microtensile bond strengths of a core composite with two different viscosities, MultiCore Flow (F) and Heavy Body (HB) (Ivoclar-Vivadent), on dentin and glass-fiber posts with methacrylate resin matrices, in combination with three dentin adhesives: Syntac Classic (S), Excite DSC (E), and AdheSE (A) (Ivoclar-Vivadent). The omission of an intermediate adhesive coating on silanized posts was also examined to see if this resulted in post-core bond strength reduction. MATERIALS AND METHODS: Six experimental dentin and 6 experimental post groups were formed with different core material viscosity/adhesive combinations. In two control post groups, no adhesive was applied on the silanized posts. The core material was stratified on deep dentin or on the posts. From the built-up teeth and the post-core units, microtensile sticks were obtained. RESULTS: The bond strengths measured on dentin were (MPa): S-F 12.7 +/- 6.4; S-HB 18.3 +/- 7.6; E-F 33.1 +/- 13.7; E-HB 34.1 +/- 10.2; A-F 33.5 +/- 14.8; A-HB 35.5 +/- 14.4. The post-core strengths were: S-F 9.4 +/- 2.5; S-HB 7.1 +/- 3.8; E-F 8.6 +/- 3.8; E-HB 8.1 +/- 4.4; A-F 8.1 +/- 2.7; A-HB 8.3 +/- 2.4; no adhesive-F 10.4 +/- 3.6; no adhesive-HB 6.3 +/- 2.7. Significantly higher interfacial strengths were achieved on dentin than on posts (p < 0.05). Adhesive type significantly affected core-dentin adhesion, with Excite DSC and AdheSE outperforming Syntac Classic (p < 0.05). Neither core material viscosity nor adhesive type significantly influenced post-core adhesion (p > 0.05). Omission of an intermediate adhesive layer had no effect on post-core adhesion (p > 0.05). CONCLUSIONS: Even after post surface silanization, the bond established by the composite core material with the post remains weaker than that created with coronal dentin.

Acrylic Resins↗

Microtensile bond strength and interfacial properties of self-etching and self-adhesive resin cements used to lute composite onlays under different seating forces.

PURPOSE: To evaluate strength and morphology of the interface created on enamel and dentin by Panavia F 2.0 (P, Kuraray), RelyX Unicem (RU, 3M ESPE), and Maxcem (M, Sybron-Kerr), applied under two standardized clinically realistic seating pressures. MATERIALS AND METHODS: Composite overlays (Paradigm MZ100, 3M ESPE) were luted on flat enamel or dentin surfaces of 48 extracted molars. During the initial 5-min self-curing period, a pressure of either 20 or 40 g/mm(2) was maintained on the overlay. Curing was completed by light irradiation from the top of the overlay for 20 s. Microtensile sticks and specimens for SEM observations were obtained from the luted teeth. Bond strength data from enamel and dentin (MPa) were analyzed with separate two-way ANOVAs in order to assess the effect of cement type, luting pressure, and their interactions. Tukey's test was used for post-hoc comparisons (alpha = 0.05). RESULTS: The bond strengths (MPa) to dentin were: P 20 g/mm(2) 7.5 +/- 3.7, 40 g/mm(2) 10.9 +/- 4.5; RU 20 g/mm(2) 6.8 +/- 2.6, 40 g/mm(2) 14.5 +/- 5.3; M 20 g/mm(2) 4.1 +/- 1.8, 40 g/mm(2) 5.2 +/- 1.6. The bond strengths (MPa) to enamel were: P 20 g/mm(2) 25.2 +/- 9.0, 40 g/mm(2) 30.7 +/- 8.6; RU 20 g/mm(2) 10.7 +/- 4.9, 40 g/mm(2) 11.1 +/- 5; M 20 g/mm(2) 7.3 +/- 3.1, 40 g/mm(2) 7.9 +/- .2. Cement type, luting pressure, and the interaction of these two factors had significant influences on dentin bond strength, with RU and P outperforming M. RU and P significantly benefited from the increase in luting pressure. In enamel, the type of cement was a significant factor for adhesion, with P yielding the highest and M the lowest strength. The measured bond strengths corresponded with the morphological results. CONCLUSION: Interfacial strength and adaptation of self-etching and self-adhesive dual-curing cements are enhanced if a seating force greater than finger pressure is maintained throughout the initial self-curing period.

Acid Etching, Dental↗

Effect of the seating pressure on the adhesive bonding of indirect restorations.

PURPOSE: To evaluate the effect of two different techniques of seating pressure application on the adhesive-dentin bond of indirect restorations. METHODS: Eight non-carious human third molars were randomly divided in two treatment groups (four teeth each). Cylindrical composite blocks were luted with a resin cement (Panavia F). In Group 1, the seating pressure was applied for 5 seconds. In Group 2, the resin cylinder was maintained under constant pressure during the entire 3-minute polymerization period of the resin cement. After storing in distilled water for 24 hours, 0.9 x 0.9 mm sticks were produced from these luted specimens for microtensile bond testing and SEM examination. RESULTS: The Student t-test showed a significant difference (P < 0.05) in bond strength between Groups 1 and 2. SEM revealed the presence of structural defects and resin globules on the seating surface of the composites. These features were exclusively identified from Group 1 specimens and were probably caused by fluid transudation from the underlying dentin through the simplified self-etch adhesive (ED primer).

Dental Bonding↗

Effect of temperature on the silane coupling agents when bonding core resin to quartz fiber posts.

OBJECTIVES: To evaluate the effect of different silane agents and air-drying temperatures on bond strength of translucent quartz fibre posts to composite resin. METHODS: The post surface was etched with 10 vol% hydrogen peroxide for 20 min. A two-liquid coupling agent containing 4-methacryolxyethyl trimellitate anhydride (4-META) and gamma-trimethoxysilyil propyl methacrylate (gamma-MPTS) and two pre-hydrolyzed single component silanes containing 3-methacryloxypropyltrimethoxysilane (3-MPS) and glycid-oxi-propyl-trimetil-oxi-silane (GPS), respectively, were used for treating the fiber posts. Two different post-silanization drying temperatures were applied (21 and 38 degrees C). A dual-cure composite resin (Core Paste XP) was selected to build-up the core around posts, obtaining cylindrical specimens that were serially cut in beams and subsequently loaded in tension (muTBS) at a cross-head speed of 1 mm/min until failure. Bond strength data were statistically analyzed by two-way ANOVA and Student-Newman-Keuls tests (alpha=0.05). RESULTS: Warm air-drying determined significantly higher bond strengths (p<0.001) for glycid-oxi-propyl-trimetil-oxi-silane (11.6 MPa) and 4-methacryolxyethyl trimellitate anhydride/gamma-trimethoxysilyil propyl methacrylate silane (11.7 MPa). These two systems exhibited lower bond strengths (6.9 and 8.8 MPa, respectively) than 3-methacryloxypropyltrimethoxysilane (11.0 MPa) when dried at 21 degrees C. No statistical differences were recorded for 3-methacryloxypropyltrimethoxysilane when drying at 21 or 38 degrees C. SIGNIFICANCE: The composition of the silane coupling agent in terms of acidic content, solvent rate or degree of hydrolysis may influence resin/post bond strength when dried at 21 degrees C. Drying at 38 degrees C most likely facilitates the evaporation of solvents present in the silane agent, resulting in increased bond strength of the composite resin to the fiber post.

Acid Etching, Dental↗

Post-surface conditioning improves interfacial adhesion in post/core restorations.

OBJECTIVES: To verify the influence of different etching procedures of the post-surface on microtensile bond strength values between fiber posts and composite core materials. METHODS: 60 DT Light Posts were divided into 10 subgroups using five different chemical surface treatments and two composite materials to build-up the abutment. Chemical surface treatments including etching with potassium permanganate; treatment with 10% hydrogen peroxide; treatment with 21% sodium ethoxide; etching with potassium permanganate and 10 vol.% HCl; silanization (control group) were performed on the post's surface. The build-up was performed using (A) Core Paste XP (Dent Mat) and (B) Unifil Flow (GC). Two samples of each group were randomly selected to investigate the morphologic aspect of the post/core interface with a scanning electron microscope (SEM). The remaining specimens were cut so as to obtain microtensile sticks that were loaded in tension at a cross-head speed of 1mm/min until failure. The statistical analysis was performed using two-way ANOVA and the Tukey's test for post-hoc comparisons (alpha=0.05). RESULTS: SEM examination showed an interpenetrating adhesion network between the treated fiber post-surface and the composite material in all the groups tested. The results achieved with potassium permanganate had a significant influence on microtensile interfacial bond strength values with both the tested materials. Post-superficial treatments enhanced the bond strength particularly of Core Paste XP. SIGNIFICANCE: Etching procedures showed a similar effect on the post-surface and enhanced the adhesion of composite core build-ups as a result of micromechanical and chemical retention.

Composite Resins↗