PubMed Health⌕ Search

Biomedical subjects

Maria Filomena Santarelli

Publications and source records attributed to Maria Filomena Santarelli.

8 recordsLinked to original sources

Standardized T2* map of normal human heart in vivo to correct T2* segmental artefacts.

A segmental, multislice, multi-echo T2* MRI approach could be useful in heart iron-overloaded patients to account for heterogeneous iron distribution, demonstrated by histological studies. However, segmental T2* assessment in heart can be affected by the presence of geometrical and susceptibility artefacts, which can act on different segments in different ways. The aim of this study was to assess T2* value distribution in the left ventricle and to develop a correction procedure to compensate for artefactual variations in segmental analysis. MRI was performed in four groups of 22 subjects each: healthy subjects (I), controls (II) (thalassemia intermedia patients without iron overload), thalassemia major patients with mild (III) and heavy (IV) iron overload. Three short-axis views (basal, median, and apical) of the left ventricle were obtained and analyzed using custom-written, previously validated software. The myocardium was automatically segmented into a 16-segment standardized heart model, and the mean T2* value for each segment was calculated. Punctual distribution of T2* over the myocardium was assessed, and T2* inhomogeneity maps for the three slices were obtained. In group I, no significant variation in the mean T2* among slices was found. T2* showed a characteristic circumferential variation in all three slices. The effect of susceptibility differences induced by cardiac veins was evident, together with low-scale variations induced by geometrical artefacts. Using the mean segmental deviations as correction factors, an artefact correction map was developed and used to normalize segmental data. The correction procedure was validated on group II. Group IV showed no significant presence of segmental artefacts, confirming the hypothesis that susceptibility artefacts are additive in nature and become negligible for high levels of iron overload. Group III showed a greater variability with respect to normal subjects. The correction map failed to compensate for these variations if both additive and percentage-based corrections were applied. This may reinforce the hypothesis that true inhomogeneity in iron deposition exists.

Adult↗

Multislice multiecho T2* cardiovascular magnetic resonance for detection of the heterogeneous distribution of myocardial iron overload.

PURPOSE: To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. MATERIALS AND METHODS: T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. RESULTS: For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibility was 3.9% (r = 0.98), 5.5% (r = 0.98), and 4.7% (r = 0.99) respectively. Three groups were identified based on analysis of myocardial T2*: homogeneous (21%), heterogeneous (38%), and no myocardial iron overload (41%). The mean serum ferritin, liver iron concentration, and urinary iron excretion were significantly different among the groups. We did not find significant differences among groups in biventricular function. There was a correlation between the global T2* value and the T2* value in the mid-ventricular septum (r = 0.95, P < 0.0001). CONCLUSION: Multislice multiecho T2* MRI provides a noninvasive, fast, reproducible means of assessing myocardial iron distribution. The single measurement of mid-septal T2* correlated well with the global T2* value.

Adolescent↗

A fast and effective method to assess myocardial necrosis by means of contrast magnetic resonance imaging.

PURPOSE: Contrast magnetic resonance (CMR) can identify myocardial necrosis after gadolinium administration as a hyperenhanced (HE) area. Yet there are no software tools that can effectively quantify such an area. The aim of this study is to develop a robust and effective algorithmic method for defining the extent of myocardial necrosis evidenced through CMR. METHOD: Fifteen patients with previous myocardial infarction underwent nitrate Tetrofosmin G-SPECT and CMR. A software tool was developed, allowing semiautomatic detection of endocardial and epicardial borders and the automatic detection of HE regions. The accuracy of the proposed quantitative method of analysis has been tested with G-SPECT analysis that it is less than an ideal method for assessing myocardial viability, but at present is accepted and widely used in the clinical arena. RESULTS: Segmental (SEHE) and global extension of HE were evaluated. HE was present in 161 of the 255 analyzed segments. Of the 161 HE segments, the mean SEHE was 36 +/- 30%. The operator independence (intraobserver: r = 0.97, p < 0.0001, interobserver: r = 0.95, p < 0.0001) was good and significant, with noticeable time savings with respect to manual analysis. There was strong and inverse correlation between SEHE and scintigraphic regional uptake reduction (r = -0.66, p < 0.0001), and also a positive correlation between SEHE and SPECT defect extension (r = 0.75, p < 0.0001). When assessing the global extent of necrosis, the correlation between the two techniques was strong (r = 0.79, p = 0.0004). CONCLUSIONS: The proposed method of quantifying myocardial necrosis by CMR is highly reliable, reproducible, and operator-independent for quantifying.

Algorithms↗

Molecular imaging: its application in cardiovascular diagnosis.

The emerging field of molecular and genomic imaging is providing new opportunities to visualize and quantify the biology of living organisms. To reach such goal all the major imaging modalities concur to this new field, each with its mechanism for generating contrast and with its spatial resolution and specificity. This review deals with a brief introduction to the molecular imaging principles and reports on the state-of-the-art in cardiovascular disease.

Animals↗

An accurate and robust method for unsupervised assessment of abdominal fat by MRI.

PURPOSE: To describe and evaluate an automatic and unsupervised method for assessing the quantity and distribution of abdominal adipose tissue by MRI. MATERIAL AND METHODS: A total of 20 patients underwent whole-abdomen MRI. A total of 32 transverse T1-weighted images were acquired from each subject. The data collected were transferred to a dedicated workstation and analyzed by both our unsupervised method and a manual procedure. The proposed methodology allows the automatic processing of MRI axial images, segmenting the adipose tissue by fuzzy clustering approach. The use of an active contour algorithm on image masks provided by the fuzzy clustering algorithm allows the separation of subcutaneous fat from visceral fat. Finally, an automated procedure based on automatic image histogram analysis identifies the visceral fat. RESULTS: The accuracy, reproducibility, and speed of our automatic method were compared with the state-of-the-art manual approach. The unsupervised analysis correlated well with the manual analysis, and was significantly faster than manual tracing. Moreover, the unsupervised method was not affected by intraobserver and interobserver variability. CONCLUSION: The results obtained demonstrate that the proposed method can provide the volume of subcutaneous adipose tissue, visceral adipose tissue, global adipose tissue, and the ratio between subcutaneous and visceral fat in an unsupervised and effective manner.

Abdominal Cavity↗

A new method for quantitative cellular imaging on 3-D scaffolds using fluorescence microscopy.

This paper presents a new image processing technique for estimating cell numbers and contours in three-dimensional (3-D) microfabricated scaffolds. The method is based on a statistical approach, and utilizes the extreme value theory, which assumes that cells in the image field are rare, high-intensity events. Confocal microscopy images of fibroblasts on 3-D structures were processed using the method, and the resulting data on cell numbers was compared with countings obtained using a Burker chamber. The results were identical to within a few percent.

3T3 Cells↗

New technological developments in the clinical imaging of atherosclerotic plaque.

Direct visualization of the composition of the atherosclerotic plaque during its natural history and after therapeutic intervention may be helpful in detecting lesions with high risk of acute events and in understanding progression and regression of the disease. A wide variety of invasive and non-invasive imaging techniques is available to detect clue aspects of atherosclerosis from the early stage to the clinical evidence appearance. We will firstly review the ongoing technological and clinical research on both invasive and non-invasive techniques. Afterward, we will discuss in detail the use of high-resolution, multi-contrast magnetic resonance imaging for non-invasive imaging of the plaque and its characterization in terms of its various components (i.e., thickness, lipid, fibrous, calcium, or thrombus). Finally, we will describe the potential of quantitative analysis in describing of plaque constituents with improved reproducibility.

Angioscopy↗

A fast and accurate simulator for the design of birdcage coils in MRI.

The birdcage coils are extensively used in MRI systems since they introduce a high signal to noise ratio and a high radiofrequency magnetic field homogeneity that guarantee a large field of view. The present article describes the implementation of a birdcage coil simulator, operating in high-pass and low-pass modes, using magnetostatic analysis of the coil. Respect to other simulators described in literature, our simulator allows to obtain in short time not only the dominant frequency mode, but also the complete resonant frequency spectrum and the relevant magnetic field pattern with high accuracy. Our simulator accounts for all the inductances including the mutual inductances between conductors. Moreover, the inductance calculation includes an accurately birdcage geometry description and the effect of a radiofrequency shield. The knowledge of all the resonance modes introduced by a birdcage coil is twofold useful during birdcage coil design: --higher order modes should be pushed far from the fundamental one, --for particular applications, it is necessary to localize other resonant modes (as the Helmholtz mode) jointly to the dominant mode. The knowledge of the magnetic field pattern allows to a priori verify the field homogeneity created inside the coil, when varying the coil dimension and mainly the number of the coil legs. The coil is analyzed using equivalent circuit method. Finally, the simulator is validated by implementing a low-pass birdcage coil and comparing our data with the literature.

Computer Simulation↗