Large patent ductus arteriosus closure with multiple controlled-release coils.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Maria Teresa Palladino.
Explore the source record for details and available documents.
The association between large, left-sided patent ductus arteriosus and severe, peripheral, right pulmonary artery stenosis with no other cardiac malformation is an unreported condition that might be misdiagnosed as pulmonary hypertension due to long-standing ductal shunt. A 57-year-old man with supposed hypertensive patent ductus arteriosus underwent confirmatory cardiac catheterization. At angiography, a severe pre-hilar right pulmonary artery stenosis (peak pressure gradient, 65 mmHg) was found to complicate the hemodynamic picture of a moderate-to-large patent ductus arteriosus (QP/QS, 1.7:1), by causing pulmonary hypertension (mean pressure, 65 mmHg) and left-to-right pulmonary flow imbalance. Both lesions were treated in a single procedure of right pulmonary artery stenting and patent ductus arteriosus closure, after which the pulmonary artery pressure significantly decreased (mean, 35 mmHg). In our opinion, a thorough hemodynamic evaluation followed by pulmonary angiography should be mandatory before proceeding to patent ductus arteriosus closure in the adult patient who has "hypertensive" ductus, in whom possible associated malformations can be missed due to a poor echocardiographic window.
BACKGROUND: Although surgical shunt is still considered as the best palliation of congenital heart disease with reduced pulmonary blood flow, stent implantation may be technically simpler, safer and more cost-effective than surgery in high-risk patients. This study evaluated the feasibility and results of this option in patients with duct-dependent pulmonary blood flow or systemic-to-pulmonary shunt malfunction. METHODS: Between April 2003 and July 2004, 9 patients (age 11 days-52 years, weight 2.1-52 kg) with complex congenital heart disease underwent stent implantation inside the patent ductus arteriosus (4 patients) or a stenotic surgical shunt (5 patients). RESULTS: The stenting procedure was successfully completed in all cases. The procedural time was 162 +/- 36 min (range 90-225 min). The fluoroscopy time was 33.8 +/- 6.8 min. No patient died. The morbidity rate was 22.2% (1 patient had local infection at the site of puncture and 1 had transient femoral artery pulse loss). After the procedure, the ductus/shunt diameter increased from 1.2 +/- 0.6 to 3.6 +/- 0.6 mm (p < 0.0001) and oxygen saturation improved from 74.0 +/- 6.5 to 85.2 +/- 3.3% (p < 0.01). Three patients underwent corrective surgery without technical problems after 8.0 +/- 1.0 months while oxygen saturation remained constantly >80% in patients still waiting for surgical repair (follow-up 5.3 +/- 3.1 months). CONCLUSIONS: Stent implantation is a technically feasible, safe and effective palliative option in high-risk surgical patients with congenital heart disease and reduced pulmonary blood flow. Although larger series are required to define the cost-effective clinical impact of this therapeutic option, it is reasonable to hypothesize a further extension of its indication even to elective and low-risk surgical patients.
Pulmonary artery stenosis is a frequent complication seen after surgical repair of tetralogy of Fallot. In this setting, endovascular stent implantation is now accepted as the first-choice therapeutic option. However, angiographic imaging still being held as mandatory to check the stent position before final deployment, this procedure is not considered suitable for patients who cannot be submitted to angiography. In this paper, we report a novel method for the correct implantation of an endovascular stent without angiographic imaging. A 9-year-old boy underwent cardiac catheterization to relieve a severe left pulmonary artery stenosis. A previous attempt had been aborted due to a life-threatening anaphylactic reaction to the contrast medium. To avoid angiography, a contrast medium-filled compliant atrial septal defect sizing balloon (Amplatzer Sizing Balloon, AGA Medical Corporation) was used to image the vessel stenosis and successfully guide stent deployment. After the procedure, the transstenotic pressure gradient disappeared and the left-to-right pulmonary perfusion imbalance almost completely reverted.
Explore the source record for details and available documents.
BACKGROUND: Transcatheter closure is now accepted as the first-choice therapeutic option in patients with patent ductus arteriosus (PDA). However, this procedure is still challenging in large PDA and/or younger patients. This study evaluated feasibility and results of this approach in large, symptomatic PDA using different devices. METHODS: Between April 2000 and July 2004, 57 patients underwent attempt of transcatheter closure of a large PDA at our Institution. Nineteen patients (33.3 %) were on pharmacologic therapy for congestive heart failure. PDA diameter was 3.2+/-1.2 mm (range 1.8-9 mm), resulting in a pulmonary to systemic flow ratio of 2.1+/-1.8 (range 1.4-5). RESULTS: The procedure was successfully performed in 54 patients (94.7%), using the Amplatzer duct occluder (ADO) device (34 patients) or a multiple detachable coil approach (20 patients). Complete PDA occlusion was recorded in 77.8% of patients at 24 hours, 92.6% at 1 month, and 94.4% at last follow-up control (23+/-12 months). PDA morphology and pulmonary to systemic flow ratio did not influence the success rate of the procedure or the residual shunt. A trend toward a higher occlusion rate at any follow-up point was recorded in the ADO group (79.5 vs 75.0% at 24 hours, 97.1 vs 85.0% at 1 month, and 97.1 vs 90% at last follow-up control, p = NS for all comparisons). CONCLUSIONS: Percutaneous closure might be considered effective and safe also in large, clinically significant PDA, by tailoring the device choice to the patient size and ductal morphology. In this setting, the multiple coil option revealed as effective as the ADO device over a mid-term follow-up.
Patients with Down's syndrome show an increased pulmonary vascular reactivity that could be due to an impaired vascular endothelial function, which is possibly related to increased oxidative stress. In 8 patients with Down's syndrome and 9 euploid patients of similar age, endothelium-dependent and -independent vasodilation was studied, measuring brachial flow velocity with an intravascular Doppler flow wire. Patients with Down's syndrome showed a significant impairment of endothelial function versus controls. In presence of the antioxidant vitamin C, endothelium-dependent vasodilation in the patients with Down's syndrome was only slightly, but not significantly, improved.
This study compared the efficacy and costs of the most used approaches for percutaneous closure of large patent ductus arteriosus, that is, multiple coils and the Amplatzer duct occluder (ADO) device. From April 2000 to September 2003, 47 patients underwent closure of large, symptomatic patent ductus arteriosus (diameter 4.6 +/- 3.0 mm/m(2); QP/QS 2.1 +/- 1.9) with multiple Cook detachable coils (n = 19) or the ADO device (n = 28). The multiple coil approach was significantly cheaper (1,389 +/- 168 vs 3,811 +/- 38, p <0.0001) but as effective as the ADO device over a mid-term follow-up (occlusion rate 89.5% vs 96.4%, p = NS).
Cardiac arrhythmias and right chamber enlargement are well known long-term sequelae of atrial septal defect (ASD). Surgical ASD closure relieves patient symptoms but often fails to revert cardiac volume overload findings. Transcatheter ASD closure might be an attractive alternative to surgery, also because of the possibility to study the amount and time-course of the electro-geometric modifications following shunt disappearance. Between March 2000 and December 2002, 24 patients (age 22.7 +16.8 years) underwent percutaneous closure of large ASD (stretched diameter >20 mm and/or QP/QS ratio >1.5:1). ASD closure was performed with the Amplatzer Septal Occluder device (mean 25 +/- 7 mm), achieving a complete occlusion in all patients at 1 month. In 6 patients, right ventricular (RV) monophasic action potential was recorded during the procedure. All patients underwent standard 12-lead electrocardiography and transthoracic echocardiography before and at 24 hours and 1 month after ASD closure. After the procedure, monophasic action potential length increased from 359 +/- 27 to 372 +/- 27 ms (p <0.0001). At 1 month, QT dispersion decreased from 54 +/- 25 to 41 +/- 17 ms (p <0.05), RV diastolic diameter decreased from 42 +/- 6 to 34 +/- 5 mm (p <0.00001), and left ventricular (LV) diastolic diameter increased from 39 +/- 5 to 44 +/- 5 mm (p <0.0001), resulting in a decrease in the RV/LV ratio from 1.11 +/- 0.22 to 0.79 +/- 0.11 (-28.8%, p <0.00001). Electrocardiographic changes, as well as the amount and time-course of RV overload relief, did not significantly differ between pediatric (<16 years of age; n = 11) and adult patients (n = 13). In conclusion, regardless of age at procedure, percutaneous ASD closure results in early striking electrical and geometric cardiac changes that may be beneficial during long-term follow-up.
Coexistence of pulmonary artery (PA) stenosis and patent ductus arteriosus (PDA) may lead to overestimating the relative importance of these malformations. This article reports on a patient with a trivial PDA and severe PA stenosis erroneously diagnosed as moderate PDA. He was successfully submitted to simultaneous PA stenting and PDA embolization.
A 3-month-old infant with tetralogy of Fallot presented with progressive severe cyanosis and intractable acidosis about 2 months after a successful modified right-sided Blalock-Taussig shunt. At cardiac catheterization, the suspected shunt malfunction was confirmed. It was due to a bulky, pear-like mass arising from the right subclavian artery and compressing the polytetrafluoroethylene conduit. Any attempt to recanalize the shunt by percutaneous techniques proved unsuccessful. At surgery, a huge dilation of the anterior wall of the right subclavian artery, that sharply bent the prosthetic conduit, was found. Pathologic examination revealed that the compressing mass was pseudo-aneurysmal in nature. Despite a second successful shunt operation with a dramatic clinical improvement, the patient died due to multiorgan failure 72 hours following surgery. Extrinsic compression by a false aneurysm is a rare cause of shunt occlusion that should always be suspected in patients presenting with a rapidly progressive shunt malfunction late after a successful shunt procedure.
Explore the source record for details and available documents.