PubMed Health⌕ Search

Biomedical subjects

Mark A A Neil

Publications and source records attributed to Mark A A Neil.

9 recordsLinked to original sources

Structurally distinct membrane nanotubes between human macrophages support long-distance vesicular traffic or surfing of bacteria.

We report that two classes of membrane nanotubes between human monocyte-derived macrophages can be distinguished by their cytoskeletal structure and their functional properties. Thin membrane nanotubes contained only F-actin, whereas thicker nanotubes, i.e., those > approximately 0.7 microm in diameter, contained both F-actin and microtubules. Bacteria could be trapped and surf along thin, but not thick, membrane nanotubes toward connected macrophage cell bodies. Once at the cell body, bacteria could then be phagocytosed. The movement of bacteria is aided by a constitutive flow of the nanotube surface because streptavidin-coated beads were similarly able to traffic along nanotubes between surface-biotinylated macrophages. Mitochondria and intracellular vesicles, including late endosomes and lysosomes, could be detected within thick, but not thin, membrane nanotubes. Analysis from kymographs demonstrated that vesicles moved in a stepwise, bidirectional manner at approximately 1 microm/s, consistent with their traffic being mediated by the microtubules found only in thick nanotubes. Vesicular traffic in thick nanotubes and surfing of beads along thin nanotubes were both stopped upon the addition of azide, demonstrating that both processes require ATP. However, microtubule destabilizing agents colchicine or nocodazole abrogated vesicular transport but not the flow of the nanotube surface, confirming that distinct cytoskeletal structures of nanotubes give rise to different functional properties. Thus, membrane nanotubes between macrophages are more complex than unvarying ubiquitous membrane tethers and facilitate several means for distal interactions between immune cells.

Actins↗

Microclusters of inhibitory killer immunoglobulin-like receptor signaling at natural killer cell immunological synapses.

We report the supramolecular organization of killer Ig-like receptor (KIR) phosphorylation using a technique applicable to imaging phosphorylation of any green fluorescent protein-tagged receptor at an intercellular contact or immune synapse. Specifically, we use fluorescence lifetime imaging (FLIM) to report Förster resonance energy transfer (FRET) between GFP-tagged KIR2DL1 and a Cy3-tagged generic anti-phosphotyrosine monoclonal antibody. Visualization of KIR phosphorylation in natural killer (NK) cells contacting target cells expressing cognate major histocompatibility complex class I proteins revealed that inhibitory signaling is spatially restricted to the immune synapse. This explains how NK cells respond appropriately when simultaneously surveying susceptible and resistant target cells. More surprising, phosphorylated KIR was confined to microclusters within the aggregate of KIR, contrary to an expected homogeneous distribution of KIR signaling across the immune synapse. Also, yellow fluorescent protein-tagged Lck, a kinase important for KIR phosphorylation, accumulated in a multifocal distribution at inhibitory synapses. Spatial confinement of receptor phosphorylation within the immune synapse may be critical to how activating and inhibitory signals are integrated in NK cells.

Cell Line↗

Fluorescence lifetime imaging provides enhanced contrast when imaging the phase-sensitive dye di-4-ANEPPDHQ in model membranes and live cells.

We apply fluorescence lifetime imaging to the membrane phase-sensing dye di-4-ANEPPDHQ in model membranes and live cells. We show that the 1700 ps lifetime shift between liquid-disordered and liquid-ordered phases offers greater contrast than the 60 nm spectral shift previously reported. Detection of cholesterol-rich membrane microdomains is confirmed by observation of the temperature dependence of membrane order and by cholesterol depletion using methyl-beta-cyclodextrin.

Cell Line↗

Quantitative 3D mapping of fluidic temperatures within microchannel networks using fluorescence lifetime imaging.

We describe a novel method for quantitatively mapping fluidic temperature with high spatial resolution within microchannels using fluorescence lifetime imaging in an optically sectioning microscope. Unlike intensity-based measurements, this approach is independent of experimental parameters, such as dye concentration and excitation/detection efficiency, thereby facilitating quantitative temperature mapping. Micrometer spatial resolution of 3D temperature distributions is readily achieved with an optical sectioning approach based on two-photon excitation. We demonstrate this technique for mapping of temperature variations across a microfluidic chip under different heating profiles and for mapping of the 3D temperature distribution across a single microchannel under applied flow conditions. This technique allows optimization of the chip design for miniaturized processes, such as on-chip PCR, for which precise temperature control is important.

Energy Transfer↗

Fluorescence imaging of two-photon linear dichroism: cholesterol depletion disrupts molecular orientation in cell membranes.

The plasma membrane of cells is an ordered environment, giving rise to anisotropic orientation and restricted motion of molecules and proteins residing in the membrane. At the same time as being an organized matrix of defined structure, the cell membrane is heterogeneous and dynamic. Here we present a method where we use fluorescence imaging of linear dichroism to measure the orientation of molecules relative to the cell membrane. By detecting linear dichroism as well as fluorescence anisotropy, the orientation parameters are separated from dynamic properties such as rotational diffusion and homo energy transfer (energy migration). The sensitivity of the technique is enhanced by using two-photon excitation for higher photo-selection compared to single photon excitation. We show here that we can accurately image lipid organization in whole cell membranes and in delicate structures such as membrane nanotubes connecting two cells. The speed of our wide-field imaging system makes it possible to image changes in orientation and anisotropy occurring on a subsecond timescale. This is demonstrated by time-lapse studies showing that cholesterol depletion rapidly disrupts the orientation of a fluorophore located within the hydrophobic region of the cell membrane but not of a surface bound probe. This is consistent with cholesterol having an important role in stabilizing and ordering the lipid tails within the plasma membrane.

Algorithms↗

Dynamic axial-position control of a laser-trapped particle by wave-front modification.

The axial position of a laser-trapped particle has been controlled by modification of the wave front by means of a membrane deformable mirror. The mirror gives wave-front modulation in terms of Zernike polynomials. By modulation of the Zernike defocus term we can modulate the particle position under conditions of laser trapping. A polystyrene particle of 1-microm diameter was moved along the optical axis direction for a distance of 2370 nm in minimum steps of 55.4 nm. We also demonstrated particle oscillation along the optical axis by changing the focal position in a sinusoidal manner. From the frequency dependency of the amplitude of particle oscillation we determined the spring constant as 91.7 nN/m.

Journal Article↗

Adaptive aberration correction in a confocal microscope.

The main advantage of confocal microscopes over their conventional counterparts is their ability to optically "section" thick specimens; the thin image slices thus obtained can be used to reconstruct three-dimensional images, a capability which is particularly useful in biological applications. However, it is well known that the resolution and optical sectioning ability can be severely degraded by system or specimen-induced aberrations. The use of high aperture lenses further exacerbates the problem. Moreover, aberrations can considerably reduce the number of photons that reach the detector, leading to lower contrast. It is rather unfortunate, therefore, that in practical microscopy, aberration-free confocal imaging is rarely achieved. Adaptive optics systems, which have been used widely to correct aberrations in astronomy, offer a solution here but also present new challenges. The optical system and the source of aberrations in a confocal microscope are considerably different and require a novel approach to wavefront sensing. This method, based upon direct measurement of Zernike aberration modes, also exhibits an axial selectivity similar to that of a confocal microscope. We demonstrate an adaptive confocal fluorescence microscope incorporating this modal sensor together with a deformable membrane mirror for aberration correction. Aberration corrected images of biological specimens show considerable improvement in contrast and apparent restoration of axial resolution.

Fourier Analysis↗

Active aberration correction for the writing of three-dimensional optical memory devices.

We describe an active optical system that both measures and corrects the aberrations introduced when writing three-dimensional bit-oriented optical memory by a two-photon absorption process. The system uses a ferroelectric liquid-crystal spatial light modulator (FLCSLM) configured as an arbitrary wave-front generator that is reconfigurable at speeds as great as 2.5 kHz. A method of aberration measurement by the FLCSLM wave-front generator is described. The same device is also used to correct the induced aberrations by preshaping the wave fronts with the conjugate phase aberration as well as to scan the focal spot in three dimensions. Experimental results show the correction of both on- and off-axis aberrations, allowing the writing of data at depths as great as 1 mm inside a LiNbO3 crystal.

Journal Article↗

New modal wave-front sensor: application to adaptive confocal fluorescence microscopy and two-photon excitation fluorescence microscopy.

Confocal and multiphoton microscopes are particularly sensitive to specimen- or system-induced aberrations, which result in decreased resolution and signal-to-noise ratio. The inclusion of an adaptive optics correction system could help overcome this limitation and restore diffraction-limited performance, but such a system requires a suitable method of wave-front measurement. By extending the concept of a modal wave-front sensor previously described by Neil et al. [J. Opt. Soc. Am. A 17, 1098-1107 (2000)], we present a new sensor capable of measuring directly the Zernike aberration modes introduced by a specimen. This modal sensor is particularly suited to applications in three-dimensional microscopy because of its inherent axial selectivity; only those wave fronts originating in the focal region contribute to the measured signal. Four wave-front sensor configurations are presented and their input response is characterized. Sensitivity matrices and axial responses are presented.

Microscopy, Confocal↗