Adaptive aberration correction in a confocal microscope.

Abstract

The main advantage of confocal microscopes over their conventional counterparts is their ability to optically "section" thick specimens; the thin image slices thus obtained can be used to reconstruct three-dimensional images, a capability which is particularly useful in biological applications. However, it is well known that the resolution and optical sectioning ability can be severely degraded by system or specimen-induced aberrations. The use of high aperture lenses further exacerbates the problem. Moreover, aberrations can considerably reduce the number of photons that reach the detector, leading to lower contrast. It is rather unfortunate, therefore, that in practical microscopy, aberration-free confocal imaging is rarely achieved. Adaptive optics systems, which have been used widely to correct aberrations in astronomy, offer a solution here but also present new challenges. The optical system and the source of aberrations in a confocal microscope are considerably different and require a novel approach to wavefront sensing. This method, based upon direct measurement of Zernike aberration modes, also exhibits an axial selectivity similar to that of a confocal microscope. We demonstrate an adaptive confocal fluorescence microscope incorporating this modal sensor together with a deformable membrane mirror for aberration correction. Aberration corrected images of biological specimens show considerable improvement in contrast and apparent restoration of axial resolution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Martin J Booth, Mark A A Neil, Rimas Juskaitis, Tony Wilson. 2002-04-16. Adaptive aberration correction in a confocal microscope.. https://doi.org/10.1073/pnas.082544799

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Identification of differentially expressed genes in multiple microarray experiments using discrete fourier transform.

Research in the post-genome sequence era has been shifting towards a functional understanding of the roles and relationships between different genes in different conditions. While the advances in genetic expression profiling techniques including microarrays enable detailed and genome-scale measurements, the extraction of meaningful information from large datasets remains a challenging task. Here, we propose a novel method of generating gene differential expression profiles such that gene expression values from one dataset can be directly compared with those of another dataset. A simplified Discrete Fourier Transform is applied to interposed gene expression values, thereby generating the 'spectra' for a pair of conditions. Using this technique, differentially expressed genes produce higher amplitudes at the Nyquist Frequency. By measuring the phase of the 'spectra' generated, the over- and under-expressed nature of the genes can be identified. This method was validated using two sets of GeneChip array data, one from prostate cancer related dataset and the other from macular degeneration related dataset. The genes identified as differentially expressed by our method were found to be similar to those published using their preferred methods. Based on our findings, the proposed DFT method could be used efficiently in identifying differentially expressed genes from multiple-array experiments from two different conditions.

Fourier Analysis↗

Observation of terahertz vibrations in Pyrococcus furiosus rubredoxin via impulsive coherent vibrational spectroscopy and nuclear resonance vibrational spectroscopy--interpretation by molecular mechanics.

We have used impulsive coherent vibrational spectroscopy (ICVS) to study the Fe(S-Cys)(4) site in oxidized rubredoxin (Rd) from Pyrococcus furiosus (Pf). In this experiment, a 15 fs visible laser pulse is used to coherently pump the sample to an excited electronic state, and a second <10 fs pulse is used to probe the change in transmission as a function of the time delay. PfRd was observed to relax to the ground state by a single exponential decay with time constants of approximately 255-275 fs. Superimposed on this relaxation are oscillations caused by coherent excitation of vibrational modes in both excited and ground electronic states. Fourier transformation reveals the frequencies of these modes. The strongest ICV mode with 570 nm excitation is the symmetric Fe-S stretching mode near 310 cm(-1), compared to 313 cm(-1) in the low temperature resonance Raman. If the rubredoxin is pumped at 520 nm, a set of strong bands occurs between 20 and 110 cm(-1). Finally, there is a mode at approximately 500 cm(-1) which is similar to features near 508 cm(-1) in blue Cu proteins that have been attributed to excited state vibrations. Normal mode analysis using 488 protein atoms and 558 waters gave calculated spectra that are in good agreement with previous nuclear resonance vibrational spectra (NRVS) results. The lowest frequency normal modes are identified as collective motions of the entire protein or large segments of polypeptide. Motion in these modes may affect the polar environment of the redox site and thus tune the electron transfer functions in rubredoxins.

Fourier Analysis↗

Truncation effects in SENSE reconstruction.

Finite sampling is an important practical issue in Fourier imaging systems. Although data truncation effects are well understood in conventional Fourier imaging where a single uniform receiver channel is used for data acquisition, this issue is not yet fully addressed in parallel imaging where an array of nonuniform receiver channels is used for sensitivity encoding to enable sub-Nyquist sampling of k-space. This article presents a systematic analysis of the problem by comparing the truncation effects in parallel imaging with those in conventional Fourier imaging. Specifically, it derives a convolution kernel function to characterize the truncation effects, which is shown to be approximately equal to that associated with the conventional Fourier imaging scheme. This article also describes a set of conditions under which significant differences between the truncation effects in parallel imaging and conventional Fourier imaging occur. The results should provide useful insight into interpreting and reducing data truncation effects in parallel imaging.

Fourier Analysis↗