PubMed Health⌕ Search

Biomedical subjects

Mark A Reed

Publications and source records attributed to Mark A Reed.

9 recordsLinked to original sources

Electropolymerization on microelectrodes: functionalization technique for selective protein and DNA conjugation.

A critical shortcoming of current surface functionalization schemes is their inability to selectively coat patterned substrates at micrometer and nanometer scales. This limitation prevents localized deposition of macromolecules at high densities, thereby restricting the versatility of the surface. A new approach for functionalizing lithographically patterned substrates that eliminates the need for alignment and, thus, is scalable to any dimension is reported. We show, for the first time, that electropolymerization of derivatized phenols can functionalize patterned surfaces with amine, aldehyde, and carboxylic acid groups and demonstrate that these derivatized groups can covalently bind molecular targets, including proteins and DNA. With this approach, electrically conducting and semiconducting materials in any lithographically realizable geometry can be selectively functionalized, allowing for the sequential deposition of a myriad of chemical or biochemical species of interest at high density to a surface with minimal cross-contamination.

Benzaldehydes↗

Observation of plasmon propagation, redirection, and fan-out in silver nanowires.

We report the coupling of free-space photons (vacuum wavelength of 830 nm) to surface plasmon modes of a silver nanowire. The launch of propagating plasmons, and the subsequent emission of photons, is selective and occurs only at ends and other discontinuities of the nanowire. In addition, we observe that the nanowires redirect the plasmons through turns of radii as small as 4 microm. We exploit the radiating nature of discontinuities to find a plasmon propagation length >3 +/- 1 microm. Finally, we observe that interwire plasmon coupling occurs for overlapping wires, demonstrating plasmon fan-out at subwavelength scales.

Light↗

Microfluidic system for planar patch clamp electrode arrays.

We present a microfluidic system integrated with disposable cell interface partitions for simultaneous patch clamp recordings. Glass-supported poly(dimethylsiloxane) (PDMS) partitions, having a 2 microm air-blown aperture, were reversibly sealed to a microfluidic system including PDMS channels with isolation valves and microfabricated Ag/AgCl electrodes. Gigaseal recordings from RBL-1 cells were obtained with a 24% success rate. Simultaneous whole cell recordings from valve-isolated electrodes were obtained.

Animals↗

Motor vehicle restraint system use and risk of spine injury.

OBJECTIVE: Motor vehicle collision (MVC)-related spinal injury is a severe and often permanently disabling injury. In addition, strain injuries have been reported as a common outcome of MVCs. Although advances in automobile crashworthiness have reduced both fatalities and severe injuries, the impact of varying occupant restraint systems (seatbelts and airbags) on thoracolumbar spine injuries is unknown. This study examined the relationship between the occurrence of mild to severe cervical and thoracolumbar spine injury and occupant restraint systems among front seat occupants involved in frontal MVCs. METHODS: A retrospective cohort study was conducted among subjects obtained from the 1995-2004 National Automotive Sampling System. Cases were identified based on having sustained a spine injury of >/=1 on the Abbreviated Injury Scale (AIS), 1990 Revision. Risk risks (RRs) and 95% confidence intervals (CIs) were computed comparing occupant restraint systems with unrestrained occupants. RESULTS: We found an overall incidence of AIS1 cervical (11.8%) and thoracolumbar (3.7%) spinal injury. Seatbelt only restraints were associated with increased cervical AIS1 injury (RR = 1.40, 95% CI 1.04-1.88). However, seatbelt only restraints showed the greatest risk reduction for AIS2 spinal injuries. Airbag only restraints reduced thoracolumbar AIS1 injuries (RR = 0.29, 95% CI 0.08-1.04). Seatbelt combined with airbag use was protective for cervical AIS3+ injury overall (RR = 0.29, 95% CI 0.14-0.58), cervical neurological injury (RR = 0.19, 95% CI 0.05-0.81), and thoracolumbar AIS3+ injury overall (RR = 0.20, 95% CI 0.05-0.70). CONCLUSIONS: The results of this study suggest that seatbelts alone or in combination with an airbag increased the incidence of AIS1 spinal injuries, but provide protection against more severe injury to all regions of the spine. Airbag deployment without seatbelt use did not show increased protection relative to unrestrained occupants.

Abbreviated Injury Scale↗

Anionic O --> alpha- and beta-vinyl carbamoyl translocation of 2-(O-carbamoyl) stilbenes.

[reaction: see text] New anionic oxygen to alpha- and beta-vinyl carbamoyl migration reactions, 17a and 26a-c --> 18 and 30a-c, proceed under LDA-mediated conditions leading stereoselectively to highly substituted stilbenes bearing electron-donating and -withdrawing substituents. Compounds 17a and 26a-c are prepared by combination of efficient, directed ortho metalation, Sonogashira, and Suzuki-Miyaura cross-coupling procedures.

Journal Article↗

Speed and accuracy of head- and eye-based aiming systems at high vertical acceleration.

BACKGROUND: The benefits of using a head tracker in a fast jet to aim weapons and control sensor direction have been amply demonstrated, but head direction is difficult to control at high G. An experiment was conducted to assess whether aiming using the eye, rather than the head, might be advantageous. METHODS: A centrifuge provided sustained accelerations of up to 8 Gz. Participating aircrew were asked to point at static targets using head- or eye-aiming, maintain the acquisition while the target was lit, and then transfer to the next target as quickly as possible. A helmet-mounted scene camera recorded the subject's view of the target board. A laser mounted by the scene camera was used for head-aiming and to determine head direction. The eye tracker camera and illuminator were also helmet-mounted. The eye and scene images were recorded and analyzed off-line. RESULTS: Eye-aiming acquisition times and accuracy were affected only slightly by Gz; however, both head-aiming speed and accuracy deteriorated as Gz increased. Eye-aiming was substantially faster than head-aiming at all Gz levels, but head-aiming was more accurate under these experimental conditions. Subjective ratings supported the objective data. A majority of subjects preferred eye to head as an aiming mechanism. CONCLUSIONS: Eye-aiming was faster and easier to use than head-aiming at all Gz levels, and particularly at high Gz.

Acceleration↗

Synthesis of constrained raloxifene analogues by complementary use of Friedel-Crafts and directed remote metalation reactions.

New constrained heterocyclic analogues, 2a,b and 3, of Raloxifene (1) have been prepared by complementary Directed remote Metalation (DreM)/Friedel-Crafts cyclization approaches. Utilization of a benzylidene-thiolactone rearrangement was successfully implemented to construct benzothiophenes 13a-c in good yields. Selective deprotection of 13a and 13b induced by complexation followed by triflation gave 18 and 23, thereby allowing efficient Suzuki-Miyaura cross coupling with borolane 16 to give biaryls 19 and 24. Treatment of 19 with BCl(3) induced an intramolecular para Fridel-Crafts cyclization and concomitant double deprotection to furnish analogue 2a, a new 5,6,6,6-(C(4)S-C(6)-C(6)-C(6)) sulfur-containing heterocycle. Exposure of 25 with excess LDA induced a DreM cyclization delivering the ortho-substituted 5,6,6,6-(C(4)S-C(6)-C(6)-C(6)) heterocylic analogue 26 in 70% yield. Similar treatment of 13c and 27 afforded 30, representing the novel 5,5,6,6-(C(4)S-C(5)-C(6)-C(6)) ring system, which was subjected to Suzuki-Miyaura cross coupling with 16 to give the biaryl 31 in 93% yield; deprotection furnished the final constrained analogue 3.

Cyclohexanes↗

Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells.

The patch clamp method measures membrane currents at very high resolution when a high-resistance 'gigaseal' is established between the glass microelectrode and the cell membrane (Pflugers Arch. 391 (1981) 85; Neuron 8 (1992) 605). Here we describe the first use of the silicone elastomer, poly(dimethylsiloxane) (PDMS), for patch clamp electrodes. PDMS is an attractive material for patch clamp recordings. It has low dielectric loss and can be micromolded (Annu. Rev. Mat. Sci. 28 (1998) 153) into a shape that mimics the tip of the glass micropipette. Also, the surface chemistry of PDMS may be altered to mimic the hydrophilic nature of glass (J. Appl. Polym. Sci. 14 (1970) 2499; Annu. Rev. Mat. Sci. 28 (1998) 153), thereby allowing a high-resistance seal to a cell membrane. We present a planar electrode geometry consisting of a PDMS partition with a small aperture sealed between electrode and bath chambers. We demonstrate that a planar PDMS patch electrode, after oxidation of the elastomeric surface, permits patch clamp recording on Xenopus oocytes. Our results indicate the potential for high-throughput patch clamp recording with a planar array of PDMS electrodes.

Coated Materials, Biocompatible↗