PubMed Health⌕ Search

Biomedical subjects

Mark E Meyerhoff

Publications and source records attributed to Mark E Meyerhoff.

At least 19 recordsLinked to original sources

S-nitrosothiol detection via amperometric nitric oxide sensor with surface modified hydrogel layer containing immobilized organoselenium catalyst.

A novel electrochemical device for the direct detection of S-nitrosothiol species (RSNO) is proposed by modifying an amperometric nitric oxide (NO) gas sensor with thin hydrogel layer containing an immobilized organoselenium catalyst. The diselenide, 3,3'-dipropionicdiselenide, is covalently coupled to primary amine groups in polyethylenimine (PEI), which is further cross-linked to form a hydrogel layer on a dialysis membrane support. Such a polymer film containing the organoselenium moiety is capable of decomposing S-nitrosothiols to generate NO(g) at the distal tip of the NO sensor. Under optimized conditions, various RSNOs (e.g., nitrosocysteine (CysNO), nitrosoglutathione (GSNO), etc.) are reversibly detected at </=0.1 microM levels, with sensor lifetimes of at least 10 days. The presence of reducing agents (e.g., glutathione) added to the test solution enhances the amperometric dynamic range output to approximately 25 microM levels of RSNO species. Sensitivities observed for different small molecule RSNO species are nearly equivalent, in sharp contrast to the behavior observed previously for a similar RSNO sensing configuration based on an immobilized Cu(I/II) catalytic layer. It is further shown that the new RSNO sensors can be used to assess the "NO-generating" ability of fresh blood samples by effectively detecting the total level of reactive low molecular-weight RSNO species present in such samples.

Animals↗

Catalytic generation of nitric oxide from S-nitrosothiols using immobilized organoselenium species.

Novel nitric oxide (NO) generating polymeric materials possessing immobilized organoselenium species are described. These materials mimic the capability of small organoselenium molecules as well as a known selenium-containing enzyme, glutathione peroxidase (GPx), by catalytically decomposing S-nitrosothiols (RSNO) into NO and the corresponding free thiol. Model polymeric materials, e.g., cellulose filter paper and polyethylenimine, are modified with an appropriate diselenide species covalently linked to the polymeric structures. Such organoselenium (RSe)-derivatized polymers are shown to generate NO from RSNO species in the presence of an appropriate thiol reducing agent (e.g., glutathione). The likely involvement of both immobilized selenol/selenolate and diselenide species for NO production is suggested via a catalytic pathway, as deduced in separate homogeneous solution phase experiments using non-immobilized forms of small organodiselenide species. Preliminary experiments with the new RSe-polymers clearly demonstrate the ability of such materials to generate NO from RSNO species even after the contact with fresh animal plasma. It is anticipated that such NO generation from endogenous S-nitrosothiols in blood could render RSe-containing polymeric materials more thromboresistant when in contact with flowing blood, owing to NO's ability to inhibit platelet adhesion and activation.

Animals↗

A rapid competitive binding nonseparation electrochemical enzyme immunoassay (NEEIA) test strip for microcystin-LR (MCLR) determination.

A competitive binding nonseparation electrochemical enzyme immunoassay (NEEIA) is described for the determination of microcystin-LR (MCLR) using a double-sided microporous gold electrode in cartridge-type cells. A gold film sputtered on one side of porous nylon membrane constitutes a working electrode, while another gold film formed on the opposite side serves as a pseudo reference electrode. After immobilizing MCLR antibody on working electrode by physical adsorption, the double-sided electrode was placed simply in a diffusion U-type or within a dry strip-type cell with a conjugate pad pre-loaded with a glucose oxidase labeled MCLR (GOx-MCLR) on working electrode side. Assays were performed in two steps: an MCLR-containing sample mixed with a known amount of GOx-MCLR conjugate either in buffer solution or in pre-loaded dry pad was incubated for an appropriate period (about 10 min) to induce competitive reaction with an immobilized anti-MCLR antibody on working electrode, and a fixed concentration of glucose solution (substrate) was then added to the backside of the working electrode. Due to the competitive nature of the assay, enzymatically generated product, hydrogen peroxide (H2O2), was detected at the working gold electrode (at +800 mV versus Au) by oxidation, and the magnitude of amperometric current was inversely proportional to the concentration of MCLR in the sample. The response time after substrate addition was about 30s. Mean recovery of MCLR added to tap water was 93.5%, with a coefficient of variation (CV) of 6.6%. The proposed competitive NEEIA system is in general comparable to existing heterogeneous enzyme immunoassays with a similar detection limit (100 pg/mL MCLR), and suitable for developing a disposable type biosensor for on-site monitoring of environment.

Biosensing Techniques↗

Gold-coated magnetic particles for solid-phase immunoassays: enhancing immobilized antibody binding efficiency and analytical performance.

The preparation and characterization of gold-coated magnetic particles are described for use as more efficient solid-phase materials in immunoassay development. A thin gold coating on commercial tosylated magnetic polystyrene particles (4.5 microm) is achieved via an electroless plating method involving initial reaction of the particles with Sn(II), followed by redox deposition of Ag0, that serves as a catalytic site for the subsequent reduction of Na3Au(SO3)2 in the presence of formaldehyde to yield the adhered gold layer. Scanning electron microscopy, energy-dispersive X-ray analysis, and X-ray photoelectron spectroscopy indicate the presence of the desired Au0 outer layer. To characterize the improved yield of antibody binding sites on such gold-coated phases, the modified particles are reacted with the free thiols of Fab' fragments of an anti-alkaline phosphatase (ALP) antibody to orient all the antigenic binding sites in a favorable direction. After equilibration with ALP, the amount of ALP bound to the surface of such particles is nearly 2.5-fold greater than on non-gold-coated particles possessing the same amount of immobilized anti-ALP Fab', but oriented randomly on the surface. The new gold-coated magnetic particles are further used as a solid phase for developing a sandwich-type enzyme immunoassay to detect C-reactive protein (CRP) using horseradish peroxidase as the enzyme label. The gold-coated magnetic particles with anti-CRP monoclonal Fab' reagents provide assays with enhanced assay slope (1.8-fold), lower nonspecific adsorption, and a detection limit improvement of nearly 10-fold (0.14 vs 1.9 ng/mL) compared to the same Fab' anti-CRP immobilized on the initial tosylated polystyrene magnetic particles. The improved assay performance is attributed to the more favorable binding orientation of the self-assembled monolayer of Fab' fragments on the gold-coated particles compared to the random orientation on the non-gold-coated surfaces.

Alkaline Phosphatase↗

Nitric oxide releasing polyurethanes with covalently linked diazeniumdiolated secondary amines.

Two novel strategies for synthesizing stable polyurethanes (PUs) capable of generating bioactive nitric oxide (NO) are described. The methods rely on covalently attaching diazeniumdiolate (N(2)O(2)(-)) groups onto secondary amine nitrogens at various positions within the polymer chain such that, when in contact with water or physiological fluids, only the two molecules of NO available from each diazeniumdiolate moiety are released into the surrounding medium, with potential byproducts remaining covalently bound to the matrix. Extensive analysis of the NO(x)() products released from the polymers was employed to develop appropriate strategies to better stabilize the diazeniumdiolate-based polymer structures. In one approach, diazeniumdiolate groups are attached to secondary amino nitrogens of alkane diamines inserted within the diol chain extender of a PU material. Oxidative loss of NO was minimized by blending the polymer with a biocompatible, relatively nonnucleophilic salt before exposing solutions of the polymer to NO during the diazeniumdiolation step. Fluxes of molecular NO from such materials during immersion in physiological buffer reached levels as high as 19 pmol x cm(-2) x s(-1) with a total recovery of 21 nmol of NO/mg of PU. A second general synthetic strategy involved omega-haloalkylating the urethane nitrogens and then displacing the halide from the resulting polymer with a nucleophilic polyamine to form a PU with pendent amino groups suitable for diazeniumdiolation. Commercially available Pellethane 2363-80AE that was bromobutylated and then reacted with diethylenetriamine and further exposed to gaseous NO proved stable in solid form for several months, but released NO with a total recovery of 17 nmol/mg upon immersion in physiological buffer. This material showed an initial NO flux of 14 pmol x cm(-2) x s(-1) when immersed in pH 7.4 buffer at 37 degrees C, with gradually decreasing but still observable fluxes for up to 6 days.

Amines↗

Water-soluble poly(ethylenimine)-based nitric oxide donors: preparation, characterization, and potential application in hemodialysis.

A novel approach to potentially resolve serious thrombosis issues associated with kidney dialysis (hemodialysis) therapies is described. New water-soluble polymeric nitric oxide (NO) donors, based on the diazeniumdiolated branched poly(ethylenimine)s and their derivatives, are prepared and characterized. These macromolecular NO donors (with up to 4.15 micromol/mg of total NO release) are utilized as additives to the dialysate solution of model dialysis filters. The presence of these species can create a localized increase in NO levels at the high surface area dialysis fiber/blood interface within the hemodialyzers. Nitric oxide is a naturally occurring and potent anti-platelet agent and is expected to greatly decrease the risk of thrombosis in the dialysis units.

Carboxylic Acids↗

Mediation of in vivo glucose sensor inflammatory response via nitric oxide release.

In vivo glucose sensor nitric oxide (NO) release is a means of mediating the inflammatory response that may cause sensor/tissue interactions and degraded sensor performance. The NO release (NOr) sensors were prepared by doping the outer polymeric membrane coating of previously reported needle-type electrochemical sensors with suitable lipophilic diazeniumdiolate species. The Clarke error grid correlation of sensor glycemia estimates versus blood glucose measured in Sprague-Dawley rats yielded 99.7% of the points for NOr sensors and 96.3% of points for the control within zones A and B (clinically acceptable) on Day 1, with a similar correlation for Day 3. Histological examination of the implant site demonstrated that the inflammatory response was significantly decreased for 100% of the NOr sensors at 24 h. The NOr sensors also showed a reduced run-in time of minutes versus hours for control sensors. NO evolution does increase protein nitration in tissue surrounding the sensor, which may be linked to the suppression of inflammation. This study further emphasizes the importance of NO as an electroactive species that can potentially interfere with glucose (peroxide) detection. The NOr sensor offers a viable option for in vivo glucose sensor development.

Animals↗

Diazeniumdiolate ions as leaving groups in anomeric displacement reactions: a protection-deprotection strategy for ionic diazeniumdiolates.

Diazeniumdiolate ions [R2N-N(O)=N-O-] are of growing interest pharmacologically for their ability to generate up to two molar equivalents of bioactive nitric oxide (NO) spontaneously on protonating the amino nitrogen. Accordingly, their stability increases as the pH is raised. Here we show that the corresponding beta-glucosides [R2N-N(O)=N-O-Glc] decreased in stability with pH; when R2N was diethylamino, the rate equation was kobs = ko + kOH- [OH-], where ko = 7.8 x 10-7 s-1 and kOH- = 5.3 x 10-3 M-1 s-1. The primary products were 1,6-anhydroglucose and the regenerated R2N-N(O)=N-O- ion. The results were qualitatively similar to those of beta-glucosyl fluoride and p-nitrophenoxide, whose hydrolyses have been rationalized as proceeding via a glycal oxide intermediate. This chemistry offers a convenient strategy for protecting heat- and acid-sensitive diazeniumdiolate ions during manipulations that would otherwise destroy them. As an example, a poly(urethane) film that generated NO in physiological buffer at a surface flux comparable to that of the mammalian vascular endothelium was prepared by glucosylating the ionic diazeniumdiolate group attached to the diol monomer before reacting it with the bis-isocyanate, then removing the saccharide with base when the protecting group was no longer needed.

Azo Compounds↗

Fluoride-selective optical sensor based on aluminum(III)-octaethylporphyrin in thin polymeric film: further characterization and practical application.

More detailed analytical studies of a new fluoride-selective optical sensor based on the use of aluminum(III)-octaethylporphyrin and a lipophilic pH indicator (4',5'-dibromofluorescein octadecyl ester; ETH-7075) within a thin plasticized poly(vinyl chloride) film are reported. The sensor exhibits extraordinary optical selectivity for fluoride over a wide range of other anions, including anions with far more positive free energies of hydration (e.g., perchlorate, thiocyanate, nitrate, etc.). UV-visible spectrophotometric studies of the sensing films indicate that fluoride interacts with the Al(III) center of the porphyrin structure, yielding both a change in the Soret band lambda(max) of the porphyrin and a change in the protonation state of the pH indicator within the film. The same change in spectral properties of the metalloporphyrin occurs in the absence of added pH indicator or with added tetraphenylborate derivative anionic sites, but optical responses to fluoride in these cases are shown to be irreversible. The presence of the pH indicator and the simultaneous fluoride/proton coextraction equilibrium chemistry is shown to greatly enhance the reversibility of fluoride binding to the Al(III) porphyrin. Optical response toward fluoride can be observed in the range of 0.1 microM-1.6 mM. Optical selectivity coefficients of <10(-6) for common anions (e.g., sulfate, chloride, nitrate, etc.) and <10(-4) for perchlorate and thiocyanate are obtained. Measurements of fluoride in drinking water via the new optical sensor are shown to correlate well with values obtained for the same samples using a classical LaF3-based fluoride ion-selective electrode method.

Aluminum↗

Titrimetric method for determination of O-desulfated heparin in physiological samples using protamine-sensitive membrane electrode as endpoint detector.

O-Desulfated heparin (ODSH) is a promising new anti-inflammatory agent for the prevention of reperfusion injury following myocardial infarction or stroke. This partially desulfated heparin derivative has less anticoagulant activity than unfractionated heparin but retains the inherent anti-inflammatory properties of heparin. Thus, ODSH could be administered at the high doses needed to achieve desired anti-inflammatory function without risk of hemorrhage. However, given the very low anticoagulant activity of this species, traditional methods for heparin determination in clinical samples might not be well suited for ODSH measurements. In this article, a novel titrimetric method for detection of ODSH in buffer and plasma is described using a protamine-sensitive polymer membrane electrode as the detector. Titrations of ODSH with the heparin antagonist protamine yield sharp endpoints with sensitivity to ODSH in the micrograms per milliliter range for plasma samples. The stoichiometry for protamine interaction with ODSH is determined to average 1.39 microg protamine/microg ODSH in plasma. This technology is further applied to a toxicokinetic study of ODSH in an animal model, demonstrating the ability to detect the changes in ODSH concentrations in biological samples.

Animals↗

Bis-diazeniumdiolates of dialkyldiamines: enhanced nitric oxide loading of parent diamines.

[reaction: see text] The synthesis and characterization of a series of symmetric bis-dialkyldiamine-based diazeniumdiolates, RN[N(O)NO(-)Na(+)](CH(2))(x)()N[N(O)NO(-)Na(+)]R', are reported. Preparation of corresponding intramolecular diazeniumdiolates of the form RN[N(O)NO](-)(CH(2))(x)()NH(2)(+)R' with alkyl groups > (CH(2))(4)CH(3) have been shown previously to lack stability. In contrast, sodium-stabilized bis-diazeniumdiolates of such lipophilic species can be readily formed when these same diamines are reacted with NO in basic media. The resulting compounds release 4 mol of NO per mole of original diamine. This approach enables the synthesis of more lipophilic NO donors than previously possible.

Azo Compounds↗

Direct detection of S-nitrosothiols using planar amperometric nitric oxide sensor modified with polymeric films containing catalytic copper species.

The direct amperometric detection of S-nitrosothiol species (RSNOs) is realized by modifying a previously reported amperometric nitric oxide gas sensor with thin hydrophilic polyurethane films containing catalytic Cu(II)/(I) sites. Catalytic Cu(II)/(I)-mediated decomposition of S-nitrosothiols generates NO(g) in the thin polymeric film at the distal tip of the NO sensor. Three different species are examined to create the catalytic layer: (1) a lipophilic Cu(II)-ligand complex; (2) Cu(II)-phosphate salt; and (3) small (3-microm) metallic Cu(0) particles. All three catalytic layers yield reversible amperometric response in proportion to the concentration of S-nitrosothiols (e.g., nitrosocysteine, nitrosoglutathione, S-nitroso-N-acetylcysteine, S-nitrosoalbumin) present in the aqueous test solution. Sensitivity toward the different RSNO species is dependent on the respective catalytic rates of decomposition of the RSNO species by reactive Cu(I), accessibility of the species into the polyurethane layer containing the catalyst, the level of reducing agents (ascorbate) used in solution to help generate reactive Cu(I) species, and the concentration of metal ion complexing agents present in the test solution (e.g., EDTA). Under optimized conditions, all RSNO species can be detected at < or =1 microM levels, with sensor lifetimes of at least 10 days for the sensors based on Cu(II)-phosphate and Cu0 particles. It is further shown that the new RSNO sensors can be used to assess the "NO-generating" ability of fresh blood samples by effectively detecting the total level of reactive RSNO species present in such samples.

Animals↗

Highly selective optical fluoride ion sensor with submicromolar detection limit based on aluminum(III) octaethylporphyrin in thin polymeric film.

A highly selective, sensitive, and reversible fluoride optical sensing film based on aluminum(III)octaethylporphyrin as a fluoride ionophore and a lipophilic pH indicator as the optical transducer is described. The fluoride optical sensing films exhibit a submicromolar detection limit and high discrimination for fluoride over several lipophilic anions such as nitrate, perchlorate, and thiocyanate.

Aluminum↗

Synthesis, characterization, and controlled nitric oxide release from S-nitrosothiol-derivatized fumed silica polymer filler particles.

A new type of nitric oxide (NO)-releasing material is described that utilizes S-nitrosothiols anchored to tiny fumed silica (FS) particles as the NO donor system. The synthetic procedures suitable for tethering three different thiol species (cysteine, N-acetylcysteine, and N-acetylpenicillamine) to the surface of FS polymer filler particles are detailed. The thiol-derivatized particles are converted to their corresponding S-nitrosothiols by reaction with t-butylnitrite. The total NO loading on the resulting particles range from 21-138 nmol/mg for the three different thiol-derivatized materials [S-nitrosocysteine-(NO-Cys)-FS, S-nitroso-N-acetylcysteine (SNAC)-FS, and S-nitroso-N-acetylpenicillamine (SNAP)-FS], with SNAP-FS yielding the highest NO loading. NO can be generated from these particles when suspended in solution via the addition of copper(II) ions, ascorbate, or irradiation with visible light. The SNAC-FS and SNAP-FS particles can be blended in polyurethane and silicone rubber matrixes to create films that release NO at controlled rates. Polyurethane films containing SNAC-FS submerged in phosphate-buffered saline (pH 7.4) generate NO surface fluxes approximately 0.1-0.7x10(-10) mol cm-2 min-1 and SNAP-FS films generate NO fluxes of approximately 0-7.5x10(-10) mol cm-2 min-1 upon addition of increasing amounts of copper ions. Silicone rubber films containing SNAC-FS or SNAP-FS do not liberate NO upon exposure to copper ions or ascorbate in phosphate-buffered saline solution. However, such films are shown to release NO at rates proportional to increasing intensities of visible light impinging on the films. Such photoinitiated NO release from these composite materials offers the first NO-releasing hydrophobic polymers with an external on/off trigger to control NO generation.

Acetylcysteine↗

Polymers incorporating nitric oxide releasing/generating substances for improved biocompatibility of blood-contacting medical devices.

The current state-of-the-art with respect to the preparation, characterization and biomedical applications of novel nitric oxide (NO) releasing or generating polymeric materials is reviewed. Such materials show exceptional promise as coatings to prepare a new generation of medical devices with superior biocompatiblity. Nitric oxide is a well-known inhibitor of platelet adhesion and activation, as well as a potent inhibitor of smooth muscle cell proliferation. Hence, polymers that release or generate NO locally at their surface exhibit greatly enhanced thromboresistivity and have the potential to reduce neointimal hyperplasia caused by device damage to blood vessel walls. In this review, the use of diazeniumdiolates and nitrosothiols as NO donors within a variety polymeric matrixes are summarized. Such species can either be doped as discrete NO donors within polymeric films, or covalently linked to polymer backbones and/or inorganic polymeric filler particles that are often employed to enhance the strength of biomedical polymers (e.g., fumed silica or titanium dioxide). In addition, very recent efforts to create catalytic polymers possessing immobilized Cu(II) sites capable of generating NO from endogenous oxidized forms of NO already present in blood and other physiological fluids (nitrite and nitrosothiols) are discussed. Preliminary literature data illustrating the efficacy of the various NO release/generating polymers as coatings for intravascular sensors, extracorporeal blood loop circuits, and arteriovenous grafts/shunts are reviewed.

Animals↗

Preparation and characterization of polymeric coatings with combined nitric oxide release and immobilized active heparin.

A new dual acting polymeric coating is described that combines nitric oxide (NO) release with surface-bound active heparin, with the aim of mimicking the nonthrombogenic properties of the endothelial cell (EC) layer that lines the inner wall of healthy blood vessels. A trilayer membrane configuration is employed to create the proposed blood compatible coating. A given polymeric substrate (e.g., the outer surface of a catheter sleeve, etc.) is first coated with a dense polymer layer, followed by a plasticized poly(vinyl chloride) (PVC) or polyurethane (PU) layer doped with a lipophilic N-diazeniumdiolate as the NO donor species. Finally, an outer aminated polymer layer is applied. Porcine heparin is then covalently linked to the outer layer via formation of amide bonds. The surface-bound heparin is shown to possess anti-coagulant activity in the range of 4.80-6.39 mIU/cm2 as determined by a chromogenic anti-Factor Xa assay. Further, the surface NO flux from the underlying polymer layer containing the diazeniumdiolate species can be controlled and maintained at various levels (from 0.5 to 60 x 10(-10) mol cm(-2)min(-1)) for at least 24 h and up to 1 week (depending on the flux level desired) by changing the chemical/polymer composition of the NO release layer. The proposed polymeric coatings are capable of functioning by two complementary anti-thrombotic mechanisms, one based on the potent anti-platelet activity of NO, and the other the result of the ability of immobilized heparin to inhibit Factor Xa and thrombin (Factor IIa). Thus, the proposed polymeric coatings are expected to exhibit greatly enhanced thromboresistivity compared to polymers that utilize either immobilized heparin or NO release alone.

Animals↗