PubMed Health⌕ Search

Biomedical subjects

Mark E Meyerhoff

Publications and source records attributed to Mark E Meyerhoff.

At least 37 records · Page 2Linked to original sources

Nitric oxide-releasing hydrophobic polymers: preparation, characterization, and potential biomedical applications.

The synthetic methods used recently in this laboratory to prepare a variety of novel nitric oxide (NO)-releasing hydrophobic polymers are reviewed. Nitric oxide is a well known inhibitor of platelet adhesion and activation. Thus, such NO release polymers have potential applications as thromboresistant coatings for a large number of blood-contacting biomedical devices (e.g., in vivo sensors, arteriovenous grafts, stents, catheters, extracorporeal circuits). The approaches taken to prepare NO releasing poly(vinyl chloride) (PVC), silicone rubber (SR), polymethacrylate (PM), and polyurethane (PU) materials are grouped into three categories: (1) dispersion/doping of discrete diazeniumdiolated molecules within the polymeric films; (2) chemical derivatization of polymeric filler microparticles (e.g., silicon dioxide, titanium dioxide) to possess NO release chemistry and then their dispersion within the hydrophobic polymers; and (3) covalent attachment of NO release moieties to polymer backbones. Specific chemical examples of each of these approaches are summarized and the advantages and disadvantages of each are discussed. Other related work in the field of NO release polymers is also cited. It is further shown that several of the NO-releasing polymeric materials already prepared exhibit the expected improved thromboresistivity when tested in vivo using appropriate animal models.

Animals↗

Potentiometric response characteristics of polycation-sensitive membrane electrodes toward poly(amidoamine) and poly(propylenimine) dendrimers.

The potentiometric response characteristics of polycation-sensitive membrane electrodes toward two classes of polycationic dendrimers are examined. Using appropriately formulated polymer membrane electrodes composed of a dinonylnaphthalenesulfonate (DNNS) salt in a plasticized polyurethane matrix, it is shown that poly(amidoamine) (PAMAM) and poly(propylenimine) (PPI) dendrimers are readily detected at submicrogram per milliliter levels via a nonequilibrium response mechanism. The relationship between the total EMF response (at equilibrium) and the specific dendrimer structure is also examined. For both the PAMAM and PPI species, it is shown that the total EMF response does not change significantly with dendrimer generation number; however, the nonequilibrium analytically useful response curves are shifted to higher mass concentrations as the generation number is increased. The relative contributions of the terminal primary amines and the interior tertiary amines of the dendrimers to the observed EMF response are investigated by synthesis of various dendrimer derivatives (acetylated, quaternized, etc.). By comparing the total EMF responses for these derivatives as a function of sample pH, it is demonstrated that the lipophilic cation exchanger (DNNS) within the membrane phase can likely interact electrostatically with both protonated forms of the terminal primary amines and interior tertiary amines of the dendrimer structures. The practical application of the nonequilibrium potentiometric detection of dendrimers for monitoring their interaction with DNA is also demonstrated.

Amines↗

Controlled photoinitiated release of nitric oxide from polymer films containing S-nitroso-N-acetyl-DL-penicillamine derivatized fumed silica filler.

This report describes the first hydrophobic nitric oxide (NO)-releasing material that utilizes light as an external on/off trigger to control the flux of NO generated from cured polymer films. Fumed silica polymer filler particles were derivatized with S-nitroso-N-acetyl-dl-penicillamine and blended into the center layer of trilayer silicone rubber films. Nitric oxide is generated upon irradiation with light, and fluxes increase with increasing power of incident light. The ability to precisely control NO generation from this material has the potential to answer fundamental questions about the levels of NO needed to achieve desired therapeutic affects in different biomedical applications.

Delayed-Action Preparations↗

Improved planar amperometric nitric oxide sensor based on platinized platinum anode. 1. Experimental results and theory when applied for monitoring NO release from diazeniumdiolate-doped polymeric films.

An improved miniature amperometric nitric oxide sensor design with a planar sensing tip (ranging from 150 microm to 2 mm in diameter) is reported. The sensor is fabricated using a platinized platinum anode and a Ag/AgCl cathode housed behind a microporous poly(tetrafluoroethylene) (PTFE; Gore-tex) gas-permeable membrane. Platinization of the working platinum electrode surface dramatically improves the analytical performance of the sensor by providing approximately 10-fold higher sensitivity (0.8-1.3 pA/nM), approximately 10-fold lower detection limit (< or =1 nM), and extended (at least 3-fold) stability (>3 d) compared to sensors prepared with bare Pt electrodes. These improvements in performance arise from increasing the kinetics and lowering the required potential for the 3-electron oxidation of NO to nitrate, relative to that observed using a nonplatinized working electrode. The outer porous PTFE membrane provides complete selectivity for NO over nitrite ions (up to 10 mM nitrite). The new sensor is applied for surface measurements of NO released from diazeniumdiolate-loaded silicone rubber films (SR-DACA-6/N(2)O(2)). The effects of sensor size (for sensor dimensions of 0.15-, 1-, and 2-mm o.d.) and the distance of the sensor from the surface of the NO-emitting polymer film are investigated via experiments as well as theoretical calculations. A significant analyte trapping effect is demonstrated, the degree of which depends on the sensor size and its distance from the surface. It is further demonstrated that surface NO concentrations for fresh SR-DACA-6/N(2)O(2) loaded films are also influenced by the polymer film thickness, with thicker films generating higher surface concentrations of NO.

Azo Compounds↗

Improved planar amperometric nitric oxide sensor based on platinized platinum anode. 2. Direct real-time measurement of NO generated from porcine kidney slices in the presence of l-arginine, l-arginine polymers, and protamine.

Nitric oxide generation from porcine kidney slices is assessed using a new planar NO-selective amperometric sensor. The planar shape of the sensor allows for direct NO measurements near the surface (10 microm) of renal tissue slices in real time. Renal NO production may be modulated by the addition of L-arginine, arginine homopolymers (R2, R6, R10), and protamine, all of which can potentially transport across cellular membranes and provide a substrate for nitric oxide synthase within kidney parenchyma. Real-time amperometric measurements demonstrate that most L-arginine species can translocate across the cell membrane and rapidly increase NO production. However, no increase in NO generation is observed when the dimer of L-arginine (R2) is added to the solution bathing the tissue, suggesting that this species cannot permeate cell membranes. The degree of enhancement in NO generation observed for L-arginine and the larger peptides depends on the structure and follows the following sequence: R10 (decamer) > protamine > R6 (hexamer) > L-arginine. Protamine and the R10 decamer, especially, induce the largest increases in NO generation owing to their apparent rapid translocation into cells and subsequent cleavage by proteases to create high intracellular levels of L-arginine. The effect of sensor size (for sensor dimensions of 0.15- and 1-mm outer diameters) on the measured surface NO levels is also examined. The larger sensor traps more NO but hinders access of the L-arginine species to the tissue area between the flat distal plane of the sensor and the surface of the kidney slice. The use of such NO-generating peptides may be important in numerous biological systems that depend on NO production, such as ischemia-reperfusion injury and thrombogenesis.

Animals↗

Nitric oxide-releasing biopolymers inhibit thrombus formation in a sheep model of arteriovenous bridge grafts.

OBJECTIVES: Nitric oxide (NO), produced by normal vascular endothelial cells, reduces platelet aggregation and thrombus formation. NO-releasing biopolymers have the potential to prolong vascular graft and stent patency without adverse systemic vasodilation. METHODS: 5-mm polyurethane vascular grafts coated with a polymer containing the NO-donor dialkylhexanediamine diazeniumdiolate were implanted for 21 days in a sheep arteriovenous bridge-graft model. RESULTS: Eighty percent (4/5) of grafts coated with the NO-releasing polymer remained patent through the 21 day implantation period, compared to fifty percent (2/4) of sham-coated grafts and no (0/3) uncoated grafts. Thrombus-free surface area (+/-SEM) of explanted grafts was significantly increased in NO-donor coated grafts (98.2% +/- 0.9%) compared with sham-coated (79.2% +/- 8.6%) and uncoated (47.2% +/- 5.4%) grafts ( P = .00046). Examination of the graft surface showed no adherent thrombus or platelets and no inflammatory cell infiltration in NO-donor coated grafts, while control grafts showed adherent complex surface thrombus consisting of red blood cells in an amorphous fibrin matrix, as well as significant red blood cell and inflammatory cell infiltration into the graft wall. CONCLUSION: In this study we determined that local NO release from the luminal surface of prosthetic vascular grafts can reduce thrombus formation and prolong patency in a model of prosthetic arteriovenous bridge grafts in adult sheep. These findings may translate into improved function and improved primary patency rates in small-diameter prosthetic vascular grafts.

Animals↗

Catalytic generation of nitric oxide from nitrite at the interface of polymeric films doped with lipophilic CuII-complex: a potential route to the preparation of thromboresistant coatings.

A novel approach potentially useful for the development of more thromboresistant polymeric materials is examined. The method is based on the catalytic generation of nitric oxide (NO) via Cu(I) mediated reduction of nitrite ions. Preliminary solution phase studies demonstrate that ascorbate or thiolate anions can generate Cu(I) from Cu(II) with subsequent catalytic conversion of any nitrite ions present to NO by the unstable Cu(I) species. Incorporation of this same chemistry within a hydrophobic polymeric material requires immobilizing Cu(II) ions into a polymeric phase via use of a lipophilic Cu(II) chelating ligand (dibenzo [e,k]-2,3,8,9-tetraphenyl-1,4,7,10-tetraaza-cyclododeca-1,3,7,9-tetraene (DTTCT)). It is shown that this complex can be reduced to its Cu(I) form by appropriate reducing equivalents present in the bathing solution. The resulting Cu(I) complex can then reduce nitrite to NO with the NO generation occurring at the polymer/solution interface at physiological pH. Data from chemiluminescence experiments indicate that the flux of NO at the polymer surface is comparable to that of endothelial cells (>/=1x10(-10)mol/cm(2)min) when 0.5mM nitrite/1mM ascorbate are present in the bathing solution. Potentially more useful NO generation can be achieved by doping the polymer film with the Cu(II) complex along with a lipophilic quaternary ammonium nitrite salt. In this case reducing equivalents within the aqueous phase enable the nitrite derived from the polymer to be converted into NO by the Cu(II/I) ligand complex. Films of this type are shown to generate NO for at least 6h in PBS buffer with fluxes on the order of 1.5x10(-10)mol/cm(2)min. Physiologically relevant levels of NO release are also shown to exist at the polymer interface when films are soaked in fresh plasma as well as undiluted whole blood, indicating that endogenous reducing equivalents present in blood can efficiently reduce the Cu(II)-ligand within the polymer film. The prospects of using these new NO releasing films to devise more biocompatible polymeric coatings for biomedical applications are discussed.

Ascorbic Acid↗

More lipophilic dialkyldiamine-based diazeniumdiolates: synthesis, characterization, and application in preparing thromboresistant nitric oxide release polymeric coatings.

The synthesis, characterization, and biomedical application in preparing more thromboresistant polymeric coatings for a series of lipophilic dialkyldiamine-based diazeniumdiolatesare described. Dialkylhexamethylenediamine diazeniumdiolates of the form RN[N(O)NO](-)(CH(2))(6)NH(2)(+)R, where R = CH(3), CH(2)CH(3), (CH(2))(2)CH(3), (CH(2))(3)CH(3), (CH(2))(4)CH(3,) (CH(2))(5)CH(3), and (CH(2))(11)CH(3), are prepared via reaction of the corresponding diamine with NO. The more lipophilic diazeniumdiolates [e.g., R = (CH(2))(3)CH(3)] can be incorporated into hydrophobic polymeric films (e.g., plasticized PVC), and the resulting materials release NO for extended periods of time upon exposure to PBS buffer. The mechanism of NO release from these films is examined in detail. More stable initial NO release can be achieved by adding lipophilic anionic species (e.g., tetraphenylborate derivative) to the polymeric material to buffer the activity of protons within the organic phase. It is shown that the use of these new lipophilic NO-donors in polymers provides the ability to tailor NO release rates for a variety of medical applications. As an example, polymers doped with N,N'-dibutylhexamethylenediamine diazeniumdiolate and a tetraphenylborate derivative are employed as coatings for vascular grafts in sheep. The NO release grafts exhibited enhanced performance and had an average 95% thrombus-free surface area compared to 42% for the corresponding control grafts when examined after 21d of implantation.

Animals↗

Spontaneous catalytic generation of nitric oxide from S-nitrosothiols at the surface of polymer films doped with lipophilic copperII complex.

A new approach for preparing potentially more blood-compatible nitric oxide (NO)-generating polymeric materials is described. The method involves creating polymeric films that have catalytic sites within (lipophilic copper(II) complex) that are capable of converting endogenous S-nitrosothiols present in blood (S-nitrosoglutathione (GSNO), S-nitrosocysteine (CysNO), etc.) to NO. The catalytic NO generation reaction involves the initial reduction of Cu(II) to Cu(I) within the complex by appropriate reducing agents (e.g., thiolates or ascorbate), followed by the reduction of S-nitrosothiols to NO by the Cu(I) complex at the polymer/solution interface. The NO fluxes observed when PVC or polyurethane films containing the copper(II) complex are placed in solutions containing physiological levels of nitrosothiols (muM levels) reach ca. 8 x 10-10 mol cm-2 min-1, greater than that produced by normal endothelial cells that line all healthy blood vessels. It is thus anticipated that this spontaneous catalytic generation of NO from endogenous nitrosothiols will render such polymeric materials more thromboresistant when in contact with blood in vivo.

Catalysis↗

Enhanced sensitivity electrochemical assay of low-molecular-weight heparins using rotating polyion-sensitive membrane electrodes.

Use of a novel rotating polycation-sensitive polymer membrane electrode yields sensors that can serve as simple potentiometric titration endpoint detectors for the determination of three FDA approved low-molecular-weight heparin (LMWH) anticoagulant drugs (Fragmin, Normiflo, and Lovenox). The rotating electrode configuration dramatically improves the reproducibility and increases the sensitivity for LMWH determinations by protamine titration. At a rotation speed of 3000 rpm, electrodes with optimized thin (50 microm) polymer membranes doped with dinonylnaphthalene sulfonate (DNNS) respond to low levels of protamine (<2 microg mL(-1)) with good precision (+/-1 mV, N=10), when protamine is infused continuously into a Tris-buffer solution, pH 7.4. When infusing protamine (at 5 microg min(-1)) continuously into solutions containing Fragmin, a clear endpoint is obtained, with the amount of protamine required to reach this endpoint proportional to the level of Fragmin present. A detection limit of less than 0.02 U mL(-1) Fragmin can be obtained via this new method, approximately one order of magnitude lower than that previously reported based on a non-rotating polycation electrode. Similar low detection limits can be achieved for potentiometric titrations of Normiflo and Lovenox. Such titrations can also be carried out in undiluted plasma samples containing the various LMWH species. In this case, detection of the LMWHs at clinically relevant concentrations (>0.2 U mL(-1)) can be readily achieved.

Animals↗

Nitric oxide-releasing fumed silica particles: synthesis, characterization, and biomedical application.

The preparation, characterization, and preliminary biomedical application of various nitric oxide (NO)-releasing fumed silica particles (0.2-0.3 microm) are reported. The tiny NO-releasing particles are synthesized by first tethering alkylamines onto the surface of the silica using amine-containing silylation reagents. These amine groups are then converted to corresponding N-diazeniumdiolate groups via reaction with NO(g) at high pressure in the presence of methoxide bases (e.g., NaOMe). N-Diazeniumdiolate groups were found to form more readily with secondary amino nitrogens than primary amino nitrogens tethered to the silica. Different alkali metal cations of the methoxide bases, however, have little effect on the degree of N-diazeniumdiolate formation. The N-diazeniumdiolate moieties attached on the silica surface undergo a primarily proton-driven dissociation to NO under physiological conditions, with an "apparent" reaction order somewhat greater than 1 owing to local increases in pH at the surface of the particles as free amine groups are generated. The rates of N-diazeniumdiolate dissociation are further related to the parent amine structures and the pH of the soaking buffer. The N-diazeniumdiolate groups also undergo slow thermal dissociation to NO, with zero-order dissociation observed at both -15 and 23 degrees C. It is further shown that the resulting NO-releasing fumed silica particles can be embedded into polymer films to create coatings that are thromboresistant, via the release of NO at fluxes that mimic healthy endothelial cells (EC). For example a polyurethane coating containing 20 wt % of NO-releasing particles prepared with pendant hexane diamine structure (i.e., Sil-2N[6]-N(2)O(2)Na) is shown to exhibit improved surface thromboresistivity (compared to controls) when used to coat the inner walls of extracorporeal circuits (ECC) employed in a rabbit model for extracorporeal blood circulation.

Amines↗

Optical sensor for amine vapors based on dimer-monomer equilibrium of indium(III) octaethylporphyrin in a polymeric film.

A novel transduction chemistry for the development of a polymer film-based optical sensor that responds reversibly to gas-phase amine species at sub-ppm levels is described. The sensor is based on the equilibrium of a indium(III) octaethylporphyrin hydroxide ion-bridged dimer species with corresponding monomeric porphyrins within a thin poly(vinyl chloride) film as a function of the level of volatile amine in the surrounding gas phase. The presence of amines causes the dimeric species to be converted to monomer via the ligation of the amine with the In(III) center of the porphyrin structure. This yields a significant change in the visible absorption spectrum of the film, with a decrease in the intensity of the Soret band corresponding to the dimer (lambdamax = 390 nm) and a concomitant increase in the Soret band for the monomer lambdamax = 406-408 nm). Response to different amines is based on their relative partition coefficient into the polymer film and their strength of axial ligation reactions, with a selectivity pattern of 1-butylamine > 1-propylamine > pyridine > triethylamine > ethylamine > methylamine > diethylamine > tert-butylamine > ammonia. It is further shown that a significant concentration of dimeric species within the polymer film can only be achieved if appropriate amounts of lipophilic anionic sites are also incorporated into the polymer in the form of a tetraphenylborate derivative and the resulting film is equilibrated briefly with water prior to gas-phase measurements. With optimized film compositions, 1-butylamine can be detected in the gas phase to levels approaching 0.1 ppm, while less lipophilic ammonia can be monitored down to 10 ppm, with fully reversible responses to each species. A simple mathematical model for the response of the amine sensor is presented and shown to predict the optical behavior observed.

Amines↗

Electrochemical assay of protease activities based on polycation/polyanion complex as substrate and polyion sensitive membrane electrode detection.

A novel electrochemical method to detect protease activities is demonstrated. The assay is based on the use of a macromolecular polycation/polyanion substrate; specifically, a complex of the arginine-rich peptide protamine and pentosan polysulfate (PPS), a highly sulfated polysaccharide. As the protease of interest cleaves the protamine within the complex into smaller fragments, free PPS is generated and detected potentiometrically via a polyanion sensitive membrane electrode. Thus, the rate of free PPS generation is proportional to the activity of the protease in the assay solution. The effect of the substrate concentration is examined, as is the influence of the protamine/PPS stoichiometry on the assay performance. Using the optimized composition and concentration of the complex, the determination of trypsin at levels down to 5 U/ml and plasmin at levels approaching 0.002 U/ml can be achieved in a 10 min period. The prospects of further adapting this scheme to determine clot-busting plasminogen activators (e.g. streptokinase, tissue plasminogen activator, etc.) in samples as complex in whole blood are discussed.

Biosensing Techniques↗

In vivo biocompatibility and analytical performance of intravascular amperometric oxygen sensors prepared with improved nitric oxide-releasing silicone rubber coating.

The in vivo biocompatibility and analytical performance of amperometric oxygen-sensing catheters prepared with a new type of nitric oxide (NO)-releasing silicone rubber polymer (DACA/N2O2 SR) is reported. The NO-release silicone rubber coating contains diazeniumdiolated secondary amine sites covalently anchored to a dimethylsiloxane matrix. Narrow diameter (0.9 mm, o.d.) silicone rubber tubing coated with this polymer can be employed to construct functional oxygen-sensing catheters that release NO continuously at levels > 1 x 10(-10) mol/cm2-min for more than 20 h. In vivo evaluation of such sensors within the carotid and femoral arteries of swine over a 16-h time period demonstrates that sensors prepared with the new NO-release coating exhibit no significant platelet adhesion or thrombus formation, but control sensors (non-NO release) implanted within the same animals do show a high propensity for cell adhesion and bulk clot formation. Furthermore, the in vivo analytical data provided by sensors fabricated with NO-release coatings (N = 9) are shown to be statistically equivalent to PO2 levels measured in vitro on discrete samples of blood. Control sensors (N = 9) placed within the same animals yield average PO2 values that are statistically different (p < or = 0.05) (lower) from both the levels measured on discrete samples and those provided by the NO-release sensors over a 16-h in vivo monitoring period.

Animals↗

Nitric oxide-releasing fluorescence-based oxygen sensing polymeric films.

The in vitro analytical performance of fluorescence-based oxygen sensing polymeric films prepared with silicone rubbers that spontaneously release nitric oxide (NO) is examined. The use of NO-release polymers for fabricating functional optical sensors is proposed as a potential solution to fingering biocompatibility and concomitant performance problems encountered with prototype intravascular optical oxygen sensors. Plasticized silicone rubber films formulated with two distinct types of diazeniumdiolate NO donors release NO for more than 24 h. The optical oxygen sensing films prepared by doping these NO release polymeric materials with oxygen indicators (pyrene/perylene donor/acceptor pair) display different analytical responses, as compared to controls without NO release capability. Nonlinear Stern-Volmer behavior is observed for single-layer NO release oxygen sensors owing to heterogeneous environments for the pyrene/perylene pair and a concomitant quenching of the fluorescence by excess amine sites in such films. In contrast, a dual-layer configuration using an underlying NO-release silicone rubber layer covered with a second polymeric layer containing the fluorescent indicators is shown to yield identical sensitivity and linearity toward oxygen as conventional non-NO-releasing oxygen sensing films, while still providing surface NO fluxes necessary to yield more thromboresistive devices.

Animals↗

Synthesis and characterization of polymethacrylate-based nitric oxide donors.

A synthetic path for the preparation of methacrylic homo- and copolymers containing secondary amine groups that can be converted into nitric oxide (NO) releasing N-diazeniumdiolates is described. The polymers are obtained by a multistep procedure involving synthesis of methacrylate monomers containing boc-protected secondary amine sites, free radical benzoyl peroxide initiated polymerization, deprotection of the amine sites, and subsequent reaction of the polymers with NO in the presence of sodium methoxide. Monomers with both linear and cyclic pendant secondary amines are examined as polymer building blocks. In most cases, polymers are obtained for both types with compositions that agree well with initial monomer ratios and with number average molecular weights (M(n)) ranging from 1.69 to 2.58 x 10(6) Da. The final N-diazeniumdiolated methacrylic amine polymers are shown to release NO for extended periods of time with "apparent" t(1/2) values ranging from 30 to 60 min when suspended in phosphate buffer, pH 7.4. Total NO loading and release for these materials can reach 1.99 micromol per mg of polymer and is proportional to the amine content of the polymer. It is further shown that by using a dimethacrylate cross-linking agent in conjunction with the various methacrylate amines, suspension polymerization methods can be employed to create small (100-200 microm) polymeric methacrylate microbeads. Such microbeads that can be sequentially deprotected and converted to NO release particles via in-situ diazeniumdiolate formation as carried out for the non-crosslinked polymers.

Animals↗

Optical chloride sensor based on dimer-monomer equilibrium of indium(III) octaethylporphyrin in polymeric film.

A novel transduction chemistry for preparing optical anion-selective polymeric films that respond reversibly and selectively to chloride ion activity is demonstrated. The chloride sensors are prepared by casting thin (5-10 microm) plasticized PVC films containing indium(III) octaethylporphyrin hydroxide, along with optimized levels of a lipophilic tetraphenylborate salt, onto glass slides. When bathed in low-pH buffered solutions void of chloride, the porphyrin species spontaneously forms a hydroxide ion-bridged dimer, with the added lipophilic borate species serving as the counteranion for this complex. The maximum for the Soret absorption band of this dimeric species is shifted to 390 nm, from 410 nm for the initial monomeric porphyrin. Increases in chloride ion levels in the bathing solution results in chloride extraction and ligation to the In(III) center, and concomitant breaking of the dimer into monomeric porphyrin species, yielding a decrease in absorbance at 390 nm and an increase in optical signal at 410 nm. Under optimized conditions, optical selectivity coefficients toward chloride over a wide range of other anions (NO3-, ClO4-, SCN-, SO4(2-), F-, Br-, H2PO4-) are measured to be < 10(-3). Of all anions tested, only salicylate yields a slightly greater response than chloride. This selectivity is shown to be adequate for reversible and accurate sensing of chloride levels in diluted serum samples.

Animals↗