Evaluating a new method for maintaining body temperature during OPCAB and robotic procedures.

BACKGROUND: We evaluated the performance of a new temperature management system (Allon Thermowrap, MTRE, Israel) in maintaining normothermia during OPCAB (Off-Pump Coronary Artery Bypass) procedures and Zeus-robotic IMA (internal mammary artery) takedowns. MATERIAL/METHODS: One hundred patients were prospectively randomized to either a conventional temperature management method (thick blanket, warm intravenous fluids, operating room temperature 25 degrees C), or the new Allon Thermowrap system (pads with temperature-controlled water circulation placed on the patient's back, legs, and arms). The mean age, body surface area, total operating time, and OR air temperature were similar in both groups. RESULTS: The Allon Thermowrap system maintained a higher bladder and nasopharyngeal temperature (p<0.05). The SVR decreased (p<0.05) and the cardiac index increased (p<0.05) in patients with a body temperature>35.80 degrees C. Without reaching a significant level, the postoperative blood loss was lower in the Allon Thermowrap group. CONCLUSIONS: The Allon Thermowrap system significantly out-performed conventional techniques in achieving and maintaining normothermia during off-pump and robotic procedures.

Aged↗

The determination of the efficiency of energy dispersive X-ray spectrometers by a new reference material.

A calibration procedure for the detection efficiency of energy dispersive X-ray spectrometers (EDS) used in combination with scanning electron microscopy (SEM) for standardless electron probe microanalysis (EPMA) is presented. The procedure is based on the comparison of X-ray spectra from a reference material (RM) measured with the EDS to be calibrated and a reference EDS. The RM is certified by the line intensities in the X-ray spectrum recorded with a reference EDS and by its composition. The calibration of the reference EDS is performed using synchrotron radiation at the radiometry laboratory of the Physikalisch-Technische Bundesanstalt. Measurement of RM spectra and comparison of the specified line intensities enables a rapid efficiency calibration on most SEMs. The article reports on studies to prepare such a RM and on EDS calibration and proposes a methodology that could be implemented in current spectrometer software to enable the calibration with a minimum of operator assistance.

Journal Article↗

Relationship between factor XIII activity, fibrinogen, haemostasis screening tests and postoperative bleeding in cardiopulmonary bypass surgery.

We investigated the relationship between factor XIII, fibrinogen, blood coagulation screening tests and postoperative bleeding in 98 patients undergoing cardiopulmonary bypass (CPB) surgery. All patients received aprotinin. Blood samples were collected preoperatively (T1),after termination of CPB (T2),12 h (T3) and 24 h (T4) after surgery to determine FXIII activity, fibrinogen, platelet count, prothrombin time (PT), activated partial thromboplastin time (APTT) and D-dimers (DD). Laboratory results were correlated with the chest tube drainage 24 h after surgery and compared between patients with 24-hour chest tube drain volumes in the lower (Group 1) with those in the upper tertile (Group 3). Median FXIII and fibrinogen levels dropped by 33.9% and 34.2%, respectively, during CPB. No association between FXIII activity and the extent of postoperative bleeding was found. However, chest tube bleeding was significantly correlated with preoperative and postoperative fibrinogen. This was confirmed by comparing Groups 1 and 3. Group 3 patients had significantly lower fibrinogen levels than Group 1 at T1 - T4, although most fibrinogen values were within or above the reference range (medians, g/l: 3.5 vs. 4.0, p = 0.043 at T1; 2.3 vs. 2.7, p = 0.015 at T2; 2.9 vs. 3.3, p = 0.008 at T3; 4.2 vs. 5.2, p = 0.002 at T4). There was also a significant relationship of platelet count, PT and APTT, as measured after CPB (T2), with postoperative chest tube drainage. In conclusion, plasma FXIII activity does not influence postoperative bleeding in patients undergoing CPB surgery. There is however an inverse association between preoperative or postoperative plasma fibrinogen levels and postoperative bleeding. These findings indicate a modulation of postoperative bleeding by fibrinogen levels.

Adult↗

Influence of prolonged cardiopulmonary bypass times on splanchnic perfusion and markers of splanchnic organ function.

BACKGROUND: Cardiopulmonary bypass (CPB) is known to have considerable negative impact on perfusion and organ function. The effects of the duration of CPB on markers of splanchnic organ function was studied. METHODS: Consecutive patients undergoing elective aorto-coronary bypass grafting with CPB times (CPBT) of either less than 70 minutes (n = 15) or more than 80 minutes (n = 15) were prospectively studied. Splanchnic perfusion was assessed by measuring arterial and gastric mucosal PCO2 and calculating PCO2gap. Hepatic function was evaluated by monoethylglycinexylidide (MEGX) test and by measuring alpha-glutathione S-transferase (alpha-GST). Concentration of pancreatitis-associated protein was measured to assess pancreatic integrity. Measurements were performed after induction of anesthesia, at the end of surgery, 4 hours after arrival in the intensive care unit, and on postoperative day 1. RESULTS: The mean (+/- standard deviation) CPBT were 54 +/- 12 minutes and 99 +/- 16 minutes, respectively. PCO2gap increased significantly more in the group with CPBT of more than 80 minutes than in that with CPBT of less than 70 minutes, at +15 +/- 4 mm Hg versus +8 +/- 3 mm Hg, respectively, indicating reduction in splanchnic perfusion by longer CPBTs. Postoperative MEGX concentrations were significantly lower and postoperative alpha-GST concentrations were significantly higher in the group with CPBT of more than 80 minutes than in that with CPBT of less than 70 minutes. Plasma levels of pancreatitis-associated protein remained similar in both groups throughout the study period. CONCLUSIONS: In our patients with CPBT of more than 80 minutes, splanchnic perfusion and hepatocelluar integrity were moderately affected, whereas pancreatic function remained almost unchanged. Studies including a larger patient population are necessary to assess whether protective approaches would be helpful in patients undergoing complex cardiac surgery with very long CPBT.

Aged↗

Robotic surgery using Zeus MicroWrist technology: the next generation.

BACKGROUND: The use of computer-animated surgical instruments for various cardiac operations has been shown to be feasible, but to date, the available information regarding the operative and technical details of these procedures is still inadequate. METHODS: We used the Zeus (Computer Motion Inc., Goleta, Calif, USA) telemanipulation system to perform the internal mammary artery (IMA) takedown in 56 patients, in 12 of whom we used the newest model with MicroWristTM (Computer Motion Inc., Goleta, Calif, USA) technology. Port orientation was based on thoracic anatomy, the decisive landmarks being the mammillary line and the axillary line. The distance between ports was at least 9 cm, and the patient's arm was positioned with the left shoulder raised and angulated by not more than 90 degrees. RESULTS: Mean setup time was 44 +/- 18 minutes for the first five patients and 16 +/- 7 minutes for the last five patients, with an overall average of 24 +/- 12 minutes. IMA harvest time at the beginning reached a mean of 95 +/- 23 minutes and decreased to 44 +/- 18 minutes in the last five cases. Average IMA takedown time was 58 +/- 17 minutes. The IMA was patent with a good flow in all 56 patients. CONCLUSIONS: The introduction of robotic technology into clinical routine has resulted in safe procedures with a short learning curve. However, basic training in the modality is a must in order to achieve technical excellence.

Cardiac Surgical Procedures↗