A framework for optimising the radiographic technique in digital X-ray imaging.

The transition to digital radiology has provided new opportunities for improved image quality, made possible by the superior detective quantum efficiency and post-processing capabilities of new imaging systems, and advanced imaging applications, made possible by rapid digital image acquisition. However, this transition has taken place largely without optimising the radiographic technique used to acquire the images. This paper proposes a framework for optimising the acquisition of digital X-ray images. The proposed approach is based on the signal and noise characteristics of the digital images and the applied exposure. Signal is defined, based on the clinical task involved in an imaging application, as the difference between the detector signal with and without a target present against a representative background. Noise is determined from the noise properties of uniformly acquired images of the background, taking into consideration the absorption properties of the detector. Incident exposure is estimated or otherwise measured free in air, and converted to dose. The main figure of merit (FOM) for optimisation is defined as the signal-difference-to-noise ratio (SdNR) squared per unit exposure or (more preferably) dose. This paper highlights three specific technique optimisation studies that used this approach to optimise the radiographic technique for digital chest and breast applications. In the first study, which was focused on chest radiography with a CsI flat-panel detector, a range of kV(p) (50-150) and filtration (Z = 13-82) were examined in terms of their associated FOM as well as soft tissue to bone contrast, a factor of importance in digital chest radiography. The results indicated that additive Cu filtration can improve image quality. A second study in digital mammography using a selenium direct flat-panel detector indicated improved SdNR per unit exposure with the use of a tungsten target and a rhodium filter than conventional molybdenum target/molybdenum filter techniques. Finally, a third study focusing on cone-beam computed tomography of the breast using a CsI flat-panel detector indicated that high Z filtration of a tungsten target X-ray beam can notably improve the signal and noise characteristics of the image. The general findings highlight the fact that the techniques that are conventionally assumed to be optimum may need to be revisited for digital radiography.

Bone and Bones↗

Evaluation of fully 3-D emission mammotomography with a compact cadmium zinc telluride detector.

A compact, dedicated cadmium zinc telluride (CZT) gamma camera coupled with a fully three-dimensional (3-D) acquisition system may serve as a secondary diagnostic tool for volumetric molecular imaging of breast cancers, particularly in cases when mammographic findings are inconclusive. The developed emission mammotomography system comprises a medium field-of-view, quantized CZT detector and 3-D positioning gantry. The intrinsic energy resolution, sensitivity and spatial resolution of the detector are evaluated with Tc-99m (140 keV) filled flood sources, capillary line sources, and a 3-D frequency-resolution phantom. To mimic realistic human pendant, uncompressed breast imaging, two different phantom shapes of an average sized breast, and three different lesion diameters are imaged to evaluate the system for 3-D mammotomography. Acquisition orbits not possible with conventional emission, or transmission, systems are designed to optimize the viewable breast volume while improving sampling of the breast and anterior chest wall. Complications in camera positioning about the patient necessitate a compromise in these two orbit design criteria. Image quality is evaluated with signal-to-noise ratios and contrasts of the lesions, both with and without additional torso phantom background. Reconstructed results indicate that 3-D mammotomography, incorporating a compact CZT detector, is a promising, dedicated breast imaging technique for visualization of tumors < 1 cm in diameter. Additionally, there are no outstanding trajectories that consistently yield optimized quantitative lesion imaging parameters. Qualitatively, imaging breasts with realistic torso backgrounds (out-of-field activity) substantially alters image characteristics and breast morphology unless orbits which improve sampling are utilized. In practice, the sampling requirement may be less strict than initially anticipated.

Breast Neoplasms↗

Simulation study of a quasi-monochromatic beam for x-ray computed mammotomography.

The purpose of this simulation study was to evaluate the feasibility, benefits, and potential operating parameters of a quasi-monochromatic beam from a tungsten-target x-ray source yielding projection images. The application is intended for newly developed cone beam computed mammotomography (CmT) of an uncompressed breast. The value of a near monochromatic x-ray source for a fully 3D CmT application is the expected improved ability to separate tissues with very small differences in attenuation coefficients. The quasi-monochromatic beam is expected to yield enhanced tomographic image quality along with a low dose, equal to or less than that of dual view x-ray mammography. X-ray spectra were generated with a validated projection x-ray simulation tool (XSpect) for a range of tungsten tube potentials (40-100 kVp), filter materials (Z=51-65), and filter thicknesses (10th to 1000th value layer determined at 60 kVp). The breast was modeled from ICRU-44 breast tissue specifications, and a breast lesion was modeled as a 0.5 cm thick mass. The detector was modeled as a digital flat-panel detector with a 0.06 cm thick CsI x-ray absorption layer. Computed figures of merit (FOMs) included the ratio of mean beam energy post-breast to pre-breast and the ratio of lesion contrasts for edge-located and center-located lesions as indices of breast beam hardening, and SNR2/exposure and SNR2/dose as indices of exposure and dose efficiencies. The impact of optimization of these FOMs on lesion contrast is also examined. For all simulated filter materials at each given attenuation thickness [10th, 100th, 500th, 1000th value layers (VLs)], the mean and standard deviation of the pre-breast spectral full-width at tenth-maximum (FWTM) were 16.1 +/- 2.4, 10.3 +/- 2.2, 7.3 +/- 1.4, and 6.5 +/- 1.5 keV, respectively. The change in beam width at the tenth maximum from pre-breast to post-breast spectra ranged from 4.7 to 1.1 keV, for the thinnest and thickest filters, respectively. The higher Z filters (Z=57-63) produced a quasi-monochromatic beam that allowed the widest tube potential operating range (50-70 kVp) while maintaining minimal beam hardening and maximal SNR2/exposure and SNR2/dose, and providing a contrast greater than that obtained in the unfiltered case. Figures of merit improved with increasing filter thickness, with diminishing returns beyond the 500th value layer attenuation level. Operating parameters required to produce optimal spectra, while keeping exposures equal to that of dual view mammography, are within the capability of the commercial x-ray tube proposed for our experimental study, indicating that use of these highly attenuating filters is viable. Additional simulations comparing Mo/Mo, Mo/Rh, and W/Rh target/filter combinations indicate that they exhibit significantly lower SNR2/exposure than the present approach, precluding them from being used for computed mammotomography, while maintaining dose limitations and obtaining sufficient SNR. Beam hardening was also much higher in the existing techniques (17%-42%) than for our technique (2%). Simulations demonstrate that this quasi-monochromatic x-ray technique may enhance tissue separation for a newly developed cone beam computed mammotomography application for an uncompressed breast.

Breast↗

Mammotomography with pinhole incomplete circular orbit SPECT.

UNLABELLED: Dedicated mammotomography with pinhole incomplete circular orbit (PICO) SPECT imaging of an uncompressed pendant breast was evaluated with small, very-high-stopping-power pinhole apertures. Comparisons were made with planar pinhole scintimammography. Enhanced 3-dimensional imaging performance with very-high-stopping-power apertures is thought to ultimately yield improved sensitivities for lesion detection and identification in breast disease. METHODS: Pinhole collimators made of high-density and high atomic number (184)W or depleted (238)U, with aperture diameters from 1 to 4 mm, were used to image 0.6- and 1.0-cm-diameter spherical lesions in a pendulous, uncompressed breast phantom in planar and PICO-SPECT modes. The breast was centered on the horizontal axis of rotation of an incomplete circular orbit. Lesion, breast and body, and myocardial activities (L:B:M) were included in the phantoms to simulate clinical imaging conditions with (99m)Tc (140 keV). Lesion contrasts and signal-to-noise ratios (SNRs) for all apertures were determined for near clinical acquisition times for L:B:M ratios of 12:1:20 and 7:1:25. A set of minidisks inserted in the breast phantom was scanned to determine sampling limitations at depth from the nipple. In an initial study, a patient with biopsy-confirmed breast carcinoma was injected with 960 MBq (99m)Tc-tetrofosmin and scanned 2 h later with planar pinhole and PICO-SPECT techniques. RESULTS: Overall, for PICO-SPECT imaging there were small differences in measured counting rate sensitivity (4.9%) and lesion contrast (8.8%) with larger SNR differences (20.8%) between tungsten and depleted uranium pinhole materials at this energy and these lesion sizes. Backgrounds from simulated myocardial uptake had minor contributions in all reconstructed image volumes because of the rapid sensitivity fall-off for pinhole apertures. An optimal aperture diameter between 2 and 3 mm was determined from peak SNR, indicating that these aperture sizes may have the best performance for lesions as small as 0.6 cm in diameter with activity concentration ratios of (99m)Tc similar to those currently seen in patients. Both lesions were visualized with PICO-SPECT better than with planar pinhole imaging, with respective contrast improvements >20 times the values obtained from planar imaging for the same pinholes. In the patient study, higher contrast (>6) visualization of the active tumor periphery was obtained with PICO-SPECT than with planar imaging. CONCLUSION: These results indicate that the enhanced spatial resolution of smaller apertures outweighs the loss in sensitivity in small lesion identification with PICO-SPECT. Although the imaging differences between investigated aperture types are small and some limitations to this imaging approach exist, dedicated PICO-SPECT of the breast appears to be an improved technique compared with conventional planar pinhole scintimammography. This technique provides enhanced contrast and SNR for imaging small lesions with the high-resolution pinhole apertures along with 3-dimensional localization of the lesions.

Breast↗

A novel silicon array designed for intraoperative charged particle imaging.

A novel Si-PIN imaging array is under investigation for a charged particle (beta, positron, or alpha) sensitive intraoperative camera to be used for (residual) tumor identification during surgery. This class of collimator-less nuclear imaging device has a higher signal response for direct interactions than its scintillator-optical detector-based counterparts. Monte Carlo simulations with 635 keV betas were performed, yielding maximum and projected ranges of 1.64 and 0.55 mm in Si. Up to 90% of these betas were completely absorbed in the first 0.30 mm. Based on these results, 300 microm thick prototype Si detector arrays were designed in a 16 x 16 crossed-grid arrangement with 0.8 mm wide orthogonal strips on 1.0 mm pitch. A NIM- and CAMAC-based high-density data acquisition and processing system was used to collect the list mode data. The system was calibrated by comparisons of measured spectra to energy deposition simulations or by direct measurement of various >100 keV conversion electron or beta emitters. Mean electronic noise per strip was <3.6 keV FWHM at room temperature. When detecting positrons, which have an accompanying 511 keV annihilation background, the flood irradiated beta/gamma ratio was approximately 40, indicating that beta images could be made without the use of background rejection techniques. The intrinsic spatial resolution corresponds to the 1 x 1 mm2 pixel size, and measurements of beta emitting point and line sources yielded FWHM resolutions of 1.5 (lateral) and 2.5 mm (diagonal), respectively, with the larger widths due to particle range blurting effects. Deconvolution of the finite source size yielded intrinsic resolutions that corresponded to the image pixel size. Transmission images of circle and line phantoms with various hole sizes and pitch were resolved with either pure beta or positron irradiation without a background correction. This novel semiconductor imaging device facilitates high charged particle and low gamma sensitivity, high signal/noise ratio, and allows for compact design to potentially aid surgical guidance by providing in situ images of clinical relevance.

Alpha Particles↗