PubMed Health⌕ Search

PubMed · 12462719

A novel silicon array designed for intraoperative charged particle imaging.

Abstract

A novel Si-PIN imaging array is under investigation for a charged particle (beta, positron, or alpha) sensitive intraoperative camera to be used for (residual) tumor identification during surgery. This class of collimator-less nuclear imaging device has a higher signal response for direct interactions than its scintillator-optical detector-based counterparts. Monte Carlo simulations with 635 keV betas were performed, yielding maximum and projected ranges of 1.64 and 0.55 mm in Si. Up to 90% of these betas were completely absorbed in the first 0.30 mm. Based on these results, 300 microm thick prototype Si detector arrays were designed in a 16 x 16 crossed-grid arrangement with 0.8 mm wide orthogonal strips on 1.0 mm pitch. A NIM- and CAMAC-based high-density data acquisition and processing system was used to collect the list mode data. The system was calibrated by comparisons of measured spectra to energy deposition simulations or by direct measurement of various >100 keV conversion electron or beta emitters. Mean electronic noise per strip was <3.6 keV FWHM at room temperature. When detecting positrons, which have an accompanying 511 keV annihilation background, the flood irradiated beta/gamma ratio was approximately 40, indicating that beta images could be made without the use of background rejection techniques. The intrinsic spatial resolution corresponds to the 1 x 1 mm2 pixel size, and measurements of beta emitting point and line sources yielded FWHM resolutions of 1.5 (lateral) and 2.5 mm (diagonal), respectively, with the larger widths due to particle range blurting effects. Deconvolution of the finite source size yielded intrinsic resolutions that corresponded to the image pixel size. Transmission images of circle and line phantoms with various hole sizes and pitch were resolved with either pure beta or positron irradiation without a background correction. This novel semiconductor imaging device facilitates high charged particle and low gamma sensitivity, high signal/noise ratio, and allows for compact design to potentially aid surgical guidance by providing in situ images of clinical relevance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Martin P Tornai, Bradley E Patt, Jan S Iwanczyk, Carolyn R Tull, Lawrence R MacDonald, Edward J Hoffman. 2002. A novel silicon array designed for intraoperative charged particle imaging.. https://doi.org/10.1118/1.1514241

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An experimental analysis of some of the factors affecting gross alpha-particle activity with an emphasis on 226Ra and its progeny.

This work presents an experimental investigation of the measurement of the gross alpha-particle activity of water samples by EPA Method 900.0. The residue produced in Method 900.0 is modeled by a BaSO4 precipitate distributed over a planchet. The dependence of the gross alpha-particle activity on the activity of Ra and its progeny, on the residue mass and geometry, and on the time between sample preparation and analysis is studied. It is shown that these factors can cause the gross alpha-particle activity of a sample to vary by more than a factor of three for replicate samples and to significantly overestimate the alpha activity of the residue. For a given sample geometry, the gross-alpha particle activity generally increases as the residue mass increases owing to the presence of the radium progeny.

Alpha Particles↗

The sensitivity of the alkaline comet assay in detecting DNA lesions induced by X rays, gamma rays and alpha particles.

Experiments were designed and performed in order to investigate whether or not the different cellular energy deposition patterns of photon radiation with different energies (29 kV, 220 kV X rays; Co-60, Cs-137-gamma-rays) and alpha-radiation from an Am-241 source differ in DNA damage induction capacity in human cells. For this purpose, the alkaline comet assay (single cell gel electrophoresis) was applied to measure the amount of DNA damage in relation to the dose received. The comet assay data for the parameters '% DNA in the tail' and 'tail moment' for human peripheral lymphocytes did not indicate any difference in the initial radiation damage produced by 29 kV X rays relative to the reference radiations, 220 kV X rays and the gamma rays, whether for the total mean dose range of 0-3 Gy nor in the low-dose range. In contrast, when the 'tail length' data were analysed saturation of the fitted dose response curve appeared for X rays at about 1.5 Gy but was not apparent for gamma rays up to 3 Gy. Preliminary data for alpha exposures of HSC45-M2 cells showed a significant increase in DNA damage only at high doses (>2 Gy Am-241), but the damage at 2 Gy exceeded the damage induced at 2 Gy by Cs-137-gamma-rays by a factor of 2.5. In contrast, other experiments involving different cell systems and DNA damage indicators such as chromosomal aberrations have detected a significant increase in DNA damage at much lower doses, that is at 0.02 Gy for Am-241 and depicte a higher biological effectiveness. These results indicate that differences in biological effects arise through downstream processing of complex DNA damage.

Alpha Particles↗

A microbeam study of DNA double-strand breaks in bystander primary human fibroblasts.

Radiation-induced bystander effect has been well documented. However, the mechanisms are poorly understood. How we incorporate this effect into the classical models of risk assessment remains an open question. Here, the induction of bystander effect was studied by assessing DNA double-strand break (DSB) formation in situ with the rapid and sensitive gamma-H2AX focus formation assay. Utilising the Columbia University single-cell microbeam system to deliver 2 or 20 individual alpha particles to selected cell nuclei in a precisely known proportion of cells in a population, the induced DNA DSB incidences were quantified 30 min and 18 h post-IR. The increase in DNA DSB incidence in bystander cells lacked of a linear dose response indicating that neither the dose of irradiation nor proportion of irradiated cells in a population, is a critical parameter. This study confirms a binary all-or-nothing model of triggering the bystander response. The delay and persistence of the bystander response suggests a different mechanism of DSB induction in bystander cells than in directly irradiated cells.

Alpha Particles↗