Cardiac replacement with a total artificial heart as a bridge to transplantation.

BACKGROUND: The CardioWest Total Artificial Heart orthotopically replaces both native cardiac ventricles and all cardiac valves, thus eliminating problems commonly seen in the bridge to transplantation with left ventricular and biventricular assist devices, such as right heart failure, valvular regurgitation, cardiac arrhythmias, ventricular clots, intraventricular communications, and low blood flows. METHODS: We conducted a nonrandomized, prospective study in five centers with the use of historical controls. The purpose was to assess the safety and efficacy of the CardioWest Total Artificial Heart in transplant-eligible patients at risk for imminent death from irreversible biventricular cardiac failure. The primary end points included the rates of survival to heart transplantation and of survival after transplantation. RESULTS: Eighty-one patients received the artificial-heart device. The rate of survival to transplantation was 79 percent (95 percent confidence interval, 68 to 87 percent). Of the 35 control patients who met the same entry criteria but did not receive the artificial heart, 46 percent survived to transplantation (P<0.001). Overall, the one-year survival rate among the patients who received the artificial heart was 70 percent, as compared with 31 percent among the controls (P<0.001). One-year and five-year survival rates after transplantation among patients who had received a total artificial heart as a bridge to transplantation were 86 and 64 percent. CONCLUSIONS: Implantation of the total artificial heart improved the rate of survival to cardiac transplantation and survival after transplantation. This device prevents death in critically ill patients who have irreversible biventricular failure and are candidates for cardiac transplantation.

Critical Illness↗

Description and evaluation of a ventriculo-coronary artery bypass device that provides bi-directional coronary flow.

OBJECTIVE: The objective of this study was to assess acute patency of a new myocardial revascularization device that connects the left ventricular cavity to a coronary artery (termed ventriculo-coronary artery bypass, VCAB) thereby providing proximal and distal blood flow from the site of the anastomosis. METHODS: A device made of expanded polytetrafluoroethylene and low density polyethylene was implanted from the base of the left ventricle to the mid left anterior descending coronary artery (LAD) in 11 juvenile domestic pigs using a beating heart approach. Flow rates were measured in the distal LAD before and after implant using ultrasonic flow techniques, and patency was assessed at explant at either 2 or 4 weeks post-implantation. Myocardial perfusion using positron emission tomography (PET) was assessed in a separate set of pigs (n=2) revascularized by VCAB 2 weeks post-implant. RESULTS: Net forward flow distal to the implanted device was 73 +/- 15% of native LAD flow. PET demonstrated that the target myocardium was perfused at 85% of that seen in the remote, control myocardium. Device patency rate was 80% (4/5) at 2 weeks in one set of pigs and 83% (5/6) at 4 weeks in a second set of pigs. Histologic analysis showed formation of neointima along the extraventricular segment of the device. CONCLUSIONS: This study demonstrates the promise of perfusing ischemic myocardium using a VCAB approach with a device that provides blood flow both proximal and distal to the anastomosis. Patency of the transmyocardial device was encouraging at 2 and 4 weeks and warrants further investigation.

Animals↗

Total artificial heart bridge to transplantation: a 9-year experience with 62 patients.

BACKGROUND: The SynCardia CardioWest total artificial heart (CardioWest TAH) is a biventricular, orthotopic, pneumatic, pulsatile blood pump driven by an external console. For each ventricle, the length of the blood-flow path is shorter and the inflow and outflow valves are larger than in any other bridge-to-transplant device, resulting in greater blood flow at smaller pre-load. Such a device should be optimal for bridging transplant candidates who have biventricular failure and for whom all other therapies have failed. METHODS: From January 1, 1993, to April 1, 2002, we prospectively studied 62 consecutive CardioWest TAH implant recipients to document safety and efficacy in bridge to transplantation. We used multisystem monitoring and multidrug therapy for anti-coagulation in 58 patients starting September 1, 1994. RESULTS: Before implantation, patients were critically ill with biventricular heart failure. Mortality in this group from the time of implantation until transplantation was 23%. Causes of death during device support included multi-organ failure (6), sepsis (3), and valve entrapment (2). Forty-eight patients underwent transplantation (77%). Forty-two survived to hospital discharge (68% of the total, 88% of those undergoing transplantation). Adverse events included bleeding (20%), device malfunction (5%), fit complications (3%), mediastinal infections (5%), visceral embolus (1.6%), and stroke during support (1.6%). The linearized stroke rate was 0.068 events per patient-year. CONCLUSIONS: Sixty-eight percent of critically ill transplant candidates for whom medical therapy failed were bridged to transplantation with the CardioWest TAH and survived long-term. Most deaths that occurred during device support were related to pre-implant problems. Infection and stroke were rare events. Therefore, we recommend the CardioWest TAH as the biventricular bridge-to-transplant device of choice.

Adolescent↗

Total artificial hearts: bridge to transplantation.

The CardioWest TAH was created and initially tested at the same time as the Thoratec, Novacor, and HeartMate devices. It was designed as a permanent artificial heart and was the first-ever mechanical circulatory device to be used as destination therapy. Twenty years have passed since that early experience. Pneumatic technology is still current and being developed as in existing or new implantable Thoratec VADs the pneumatic HeartMate, and the Abiomed BVS 5000 pumps. Portable pneumatic drivers have been available since 1982, and in recent times have allowed discharge to home of substantial numbers of patients, thus reducing the length of hospital stays and making mechanical device support less expensive to society and more tolerable to patients. Within months, a portable driver for the CardioWest will be available. The documented benefits of the CardioWest TAH include rescue of: critically ill patients with advanced heart failure; patients with biventricular failure especially those with significant right heart failure, elevated pulmonary vascular resistance, or pulmonary edema; patients with renal or hepatic failure secondary to low cardiac output; patients with massive myocardial damage such as those with post-\infarction VSD or irreversible cardiac graft rejection; patients with mechanical valves or native valve disease; and patients with intractable arrhythmias and heart failure. High device outputs with restoration of normal filling pressures result in high perfusion pressures that have led to dramatic recoveries, convalescence, and return to levels of activity compatible with normal life. The average device output with the CardioWest TAH is higher than any other approved or investigational device. The reason for this resides in design simplicity this device has the shortest and largest inflow pathway. Stroke, in the authors' own series, is rare with a linearized rate of 0.068 events per patient year. If the experiences of La Pitie and the University of Arizona are combined, there has been one stroke in 25 patient years (0.04 events/patient year). Serious infections have been rare (12% of patients). No clinical mediastinitis has occurred. Drivelines have healed in tightly and never caused an "ascending" infection. There has not been a case of device endocarditis. Using a broad definition of bleeding, including takeback reoperation for bleeding, bleeding more than 8 units in the first postoperative 24 hours or 5 units over any other 48-hour period, a 25% to 36% incidence has been documented. No cases of fatal exsanguination have resulted, as there have been with the HeartMate. The incidence of bleeding as an adverse event is about 17% lower than the rate reported for the HeartMate VE LVAD, and it is about the same as that reported for Novacor and for Thoratec. Implantation of this device is relatively easy and often done (with attending help) by the authors' residents. If one follows the guidelines for fitting the device, and takes the recommended advice for implantation, hemostasis is excellent and restoration of immediate cardiac function with high flows is nearly automatic. Use of a neopericardium of 0.1 mm EPTFE at the time of implantation assures atraumatic and relatively quick re-entry for transplantation and prevents the normal inflammatory mediastinal reaction that might be desirable in a destination application. In selected patients the CardioWest TAH is the device of choice for bridge to transplantation. When a portable driver becomes available, out of hospital management of CardioWest TAH patients will be feasible and consideration of use of this device for longer term applications, (e.g., "destination therapy,") will be reasonable. A wearable driver, even smaller than a portable, will improve quality of life and expand the patient population that may be therapeutically served with this system. In short, the CardioWest TAH has come nearly full circle. It was first used as a destination device. It has since been used as a bridge to transplantation in nearly 200 patients as the Jarvik-7/Symbion TAH and, since 1993, in over 225 patients as CardioWest. The results have improved with time. Thromboembolism and infection rates have been competitive with currently available devices. Device reliability and durability have been excellent. Survival rates have been very high in a group of perhaps the sickest patients to be supported with any pulsatile device. Pneumatic technology has improved with portability and miniaturization, and there is reason to believe that it will become even better. Application of modern manufacturing techniques to this very simple device raises the possibility of significant manufacturing cost reduction, in an era of prohibitive cost for other devices. All of this establishes the CardioWest as a valuable device for any program that is seriously interested in end-stage heart disease and a likely device for permanent use in appropriately selected patients.

Anticoagulants↗

Pulse transmission coefficient: a novel nonhyperemic parameter for assessing the physiological significance of coronary artery stenoses.

OBJECTIVES: We sought to test the hypothesis that the pulse transmission coefficient (PTC) can serve as a nonhyperemic physiologic marker for the severity of coronary artery stenosis in humans. BACKGROUND: Coronary lesions may impair the transmission of pressure waves across a stenosis, potentially acting as a low-pass filter. The PTC is a novel nonhyperemic parameter that calculates the transmission of high-frequency components of the pressure signal through a stenosis. Thus, it may reflect the severity of the coronary artery stenosis. This study was designed to examine the correlation between PTC and fractional flow reserve (FFR) in patients with coronary artery disease. METHODS: Pressure signals were obtained by pressure guidewire in 56 lesions (49 patients) in the nonhyperemic state and were analyzed with a new algorithm that identifies the high-frequency components in the pressure signal. The PTC was calculated as the ratio between the distal and proximal high-frequency components of the pressure waveform across the lesion. The FFR measurements were assessed with intracoronary adenosine. RESULTS: There was a significant correlation between PTC and FFR (r = 0.81, p < 0.001). By using a receiver operating characteristic analysis, we identified a PTC < 0.60 (sensitivity 100%, specificity 98%) to be the optimal cutoff value for predicting an FFR < 0.75. CONCLUSIONS: Pulse transmission coefficient is a novel nonhyperemic parameter for the physiologic assessment of coronary artery stenoses. It correlates significantly with FFR and may predict an FFR < 0.75 with high accuracy. Pulse transmission coefficient may be useful as an adjunct measurement to FFR, especially in patients with microcirculatory disease and impaired maximal hyperemia.

Adult↗

Local hemostasis during laparoscopic partial nephrectomy using biodegradable hydrogels: initial porcine results.

BACKGROUND AND PURPOSE: Despite the advance of laparoscopic partial nephrectomy, significant technical limitations remain with regard to control of bleeding and closure of the collecting system. An attractive approach on the horizon for local hemostatic and wound control is the use of local tissue sealants. To date, sealants remain largely derived from natural biologic products and are difficult to apply laparoscopically with precise local control. In this study, we examined the novel strategy of forming occlusive tissue-adherent hydrogels utilizing a synthetic biodegradable polyethylene glycol-lactide copolymer (PEG-lactide) as an in situ occlusive barrier for hemostasis and wound control. Specifically, the objects of this study were to determine if PEG-lactide hydrogels could be formed intraperitoneally on renal tissue, to test the adhesiveness of the hydrogels to injured renal parenchyma, and to evaluate the ability of adherent hydrogel barriers to limit renal parenchymal bleeding and collecting system leakage following renal pole amputation or wedge excision. MATERIALS AND METHODS: Five kidneys from three female pigs were used in a nonsurvival study. A standardized model for laparoscopic partial nephrectomy was created by performing wedge excision or polar amputation under vascular control using a laparoscopic Satinsky clamp. Bleeding briskness following injury was assessed utilizing a scoring system and free blood quantitated comparing a conventional "clamp and wait" strategy with an adherent hydrogel strategy. For the hydrogel group, PEG-lactide hydrogel primer and macromer were applied through laparoscopic ports. The hydrogel was polymerized using a xenon light source, and the pedicle clamp was released to observe for bleeding. A subsequent opposite polar injury was created to confirm renal perfusion and the sites were compared. The kidneys were removed, and the adhesion of the hydrogel to the renal parenchyma was examined. RESULTS: The PEG-lactide macromer was effectively applied to five kidneys following partial nephrectomy. In all cases, successful intraperitoneal in situ polymerization was achieved, with resultant hydrogel formation. Polymeric hydrogel adhesion to the cut renal parenchyma was assessed semiquantitatively following vigorous cyclic washing. In all cases, polymer gels remained adherent without any evidence of peeling, delamination, or separation from the underlying tissue surface. In the control group, the mean bleeding score was 2.63 +/- 0.48 v 0.00 +/- 0.00 in the gel-treated group (P < 0.001). Blood loss in the control group was 56 +/- 5 ml v 0.00 +/- 0.00 in the gel-treated group (P < 0.001). In an ex vivo retrograde ureteral perfusion, no leakage was observed at pressure as high as 100 mm Hg. CONCLUSIONS: In this feasibility study, a biodegradable PEG-lactide polymer system photopolymerized rapidly in situ on exposed renal parenchymal surfaces, forming adherent hydrogel barriers. When applied during vascular clamping, an adequate physical bond and patch-like cap was created to prevent bleeding at physiologic renal perfusion pressures. Use of locally applied occlusive hydrogels holds promise for hemostasis and local wound control during laparoscopic urologic procedures.

Absorbable Implants↗