PubMed Health⌕ Search

PubMed · 12396442

Local hemostasis during laparoscopic partial nephrectomy using biodegradable hydrogels: initial porcine results.

Abstract

BACKGROUND AND PURPOSE: Despite the advance of laparoscopic partial nephrectomy, significant technical limitations remain with regard to control of bleeding and closure of the collecting system. An attractive approach on the horizon for local hemostatic and wound control is the use of local tissue sealants. To date, sealants remain largely derived from natural biologic products and are difficult to apply laparoscopically with precise local control. In this study, we examined the novel strategy of forming occlusive tissue-adherent hydrogels utilizing a synthetic biodegradable polyethylene glycol-lactide copolymer (PEG-lactide) as an in situ occlusive barrier for hemostasis and wound control. Specifically, the objects of this study were to determine if PEG-lactide hydrogels could be formed intraperitoneally on renal tissue, to test the adhesiveness of the hydrogels to injured renal parenchyma, and to evaluate the ability of adherent hydrogel barriers to limit renal parenchymal bleeding and collecting system leakage following renal pole amputation or wedge excision. MATERIALS AND METHODS: Five kidneys from three female pigs were used in a nonsurvival study. A standardized model for laparoscopic partial nephrectomy was created by performing wedge excision or polar amputation under vascular control using a laparoscopic Satinsky clamp. Bleeding briskness following injury was assessed utilizing a scoring system and free blood quantitated comparing a conventional "clamp and wait" strategy with an adherent hydrogel strategy. For the hydrogel group, PEG-lactide hydrogel primer and macromer were applied through laparoscopic ports. The hydrogel was polymerized using a xenon light source, and the pedicle clamp was released to observe for bleeding. A subsequent opposite polar injury was created to confirm renal perfusion and the sites were compared. The kidneys were removed, and the adhesion of the hydrogel to the renal parenchyma was examined. RESULTS: The PEG-lactide macromer was effectively applied to five kidneys following partial nephrectomy. In all cases, successful intraperitoneal in situ polymerization was achieved, with resultant hydrogel formation. Polymeric hydrogel adhesion to the cut renal parenchyma was assessed semiquantitatively following vigorous cyclic washing. In all cases, polymer gels remained adherent without any evidence of peeling, delamination, or separation from the underlying tissue surface. In the control group, the mean bleeding score was 2.63 +/- 0.48 v 0.00 +/- 0.00 in the gel-treated group (P < 0.001). Blood loss in the control group was 56 +/- 5 ml v 0.00 +/- 0.00 in the gel-treated group (P < 0.001). In an ex vivo retrograde ureteral perfusion, no leakage was observed at pressure as high as 100 mm Hg. CONCLUSIONS: In this feasibility study, a biodegradable PEG-lactide polymer system photopolymerized rapidly in situ on exposed renal parenchymal surfaces, forming adherent hydrogel barriers. When applied during vascular clamping, an adequate physical bond and patch-like cap was created to prevent bleeding at physiologic renal perfusion pressures. Use of locally applied occlusive hydrogels holds promise for hemostasis and local wound control during laparoscopic urologic procedures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sanjay Ramakumar, William W Roberts, Oscar E Fugita, Peter Colegrove, Theresa M Nicol, Thomas W Jarrett, Louis R Kavoussi, Marvin J Slepian. 2002. Local hemostasis during laparoscopic partial nephrectomy using biodegradable hydrogels: initial porcine results.. https://doi.org/10.1089/089277902760367458

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Encapsulation of proteins in biodegradable polymeric microparticles using electrospray in the Taylor cone-jet mode.

Solvent extraction (or evaporation from a W(1)/O/W(2)-dispersion), coacervation, and spray drying methods are commonly employed to encapsulate protein drugs in polymeric microparticles for sustained delivery applications. To overcome the limitations of these methods, a novel electrospray method was developed to encapsulate a model protein drug-bovine serum albumin (BSA) in biodegradable polymeric microparticles and examine the feasibility of the process in not denaturing the protein. Microparticles of approximately 20 microm diameter with corrugated surfaces and smooth surfaces were observed by scanning electron microscope. Confocal laser scanning microscope images showed that BSA was distributed evenly in microparticles. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) was employed to investigate the protein integrity of BSA released from the polymer matrix after 38 days. No protein degradation was observed during the 38 days release. The secondary structure of released BSA was characterized by Fourier transform infrared (FTIR) and circular dichroism (CD), which suggested that the released BSA was almost identical to native BSA. The encapsulation efficiency could reach 76% by adjusting the amount of the additive Pluronic F127 and processing parameters. The release profile could be tailored by the fabrication process and the sustained release of BSA could endure for more than 1 month. More than 80% of the bioactivity of BSA (evaluated by BSA ELISA kit) could be maintained after releasing from polymer matrix. Findings of the present study demonstrate that this novel electrospray method is a promising approach to encapsulate bioactive materials such as proteins, enzymes, antibiotics, and DNA fragments in biodegradable polymeric particles.

Absorbable Implants↗

A novel poly(ethylene glycol)-fibrinogen hydrogel for tibial segmental defect repair in a rat model.

The aim of this study is to investigate regeneration in a segmental bone defect using a novel fibrinogen-based hydrogel material. The use of hydrogels made from poly(ethylene glycol) (PEG) conjugated to fibrinogen for this purpose may be better to conventional fibrin-based materials as it offers an additional degree of control over the structural characteristics and biodegradation of the material. At the same time, it maintains some of the inherent biofunctionality of the fibrinogen molecule. PEGylated fibrinogen hydrogels with various degrees of proteolytic resistance based on PEG and fibrinogen composition were designed for slow, intermediate, and fast biodegradation. The hydrogels were implanted into 7-mm segmental rat tibial defects without additional osteoinductive factors with the rationale that the ingrowth matrix will displace the normal fibrin clot while sustaining a similar healing effect for a longer duration. Histological and X-ray results confirmed that the extent and distribution of newly formed bone in the defect after 5 weeks strongly parallels the biodegradation pattern of the implanted material. When compared to nonunions in animals treated with the fast-degrading implants and untreated control animals, the rats implanted with the intermediate-degrading material exhibited osteoneogenesis. This data supports the hypothesis that the perseverance of the PEGylated fibrinogen material can be synchronized with the optimal healing characteristics of a segmental osseous defect and that the consequent sustained release of fibrinogen fragments facilitates the osteogenic response at the injury site. The PEGylated fibrinogen material may, therefore, be a highly efficacious material for promoting the healing of bone defects and especially nonunion fractures.

Absorbable Implants↗

Pores in synthetic nerve conduits are beneficial to regeneration.

Current opinion holds that pores in synthetic nerve guides facilitate nerve regeneration. Solid factual support for this opinion, however, is absent; most of the relevant studies assessed only morphological parameters and results have been contradictory. To evaluate the effect of pores, the rat sciatic nerve was either autografted or grafted with nonporous, macroporous (10-230 mum), and microporous (1-10 microm) biodegradable epsilon-caprolactone grafts. Twelve weeks later, the grafted nerves were resected, and the electrophysiological properties were determined in vitro. Subsequently midgraft-level sections were inspected, and peroneal nerve sections were evaluated morphometrically. Finally, the gastrocnemic and tibial muscle morphometrical properties were quantified. The microporous nerve graft performed much better than the nonporous and macroporous grafts with respect to most parameters: it was bridged by a free floating bundle that contained myelinated nerve fibers, there were more nerve fibers present distal to the graft, the electrophysiological response rate was higher, and the decrease in muscle cross-sectional area was markedly smaller. Hence, the present study demonstrates the beneficial effect of synthetic nerve guide pores on nerve regeneration, although with the caveat that not pores per se, but only small (1-10 microm) pores were effective.

Absorbable Implants↗