PubMed Health⌕ Search

Biomedical subjects

Matthias Taupitz

Publications and source records attributed to Matthias Taupitz.

At least 19 recordsLinked to original sources

Local staging of rectal cancer: the current role of MRI.

With the advent of powerful gradient coil systems and high-resolution surface coils, magnetic resonance imaging (MRI) has recently extended its role in the staging of rectal cancer. MRI is superior to endorectal ultrasound, the most widely used staging modality in patients with rectal tumors, in that it visualizes not only the intestinal wall but also the surrounding pelvic anatomy. The crucial advantage of MRI is not that it enables exact T-staging but precise evaluation of the topographic relationship of a tumor to the mesorectal fascia. This fascia is the most important anatomic landmark for the feasibility of total mesorectal excision, which has evolved into the standard operative procedure for the resection of cancer located in the middle or lower third of the rectum. MRI is currently the only imaging modality that is highly accurate in predicting whether or not it is likely that a tumor-free margin can be achieved and thus provides important information for planning of an effective therapeutic strategy, especially in patients with advanced rectal cancer.

Contrast Media↗

Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging.

BACKGROUND: Multislice computed tomography (CT) and magnetic resonance imaging (MRI) are the main candidates for noninvasive coronary angiography; however, multislice CT, unlike MRI, exposes patients to radiation and an iodinated intravenous contrast agent. OBJECTIVE: To compare the diagnostic accuracy of multislice CT and MRI for noninvasive detection of clinically significant coronary stenoses (> or =50%). DESIGN: Prospective intention-to-diagnose study. SETTING: Single tertiary referral center, Berlin, Germany. PATIENTS: 129 consecutive patients with suspected coronary artery disease. INTERVENTIONS: Multislice CT and MRI were both performed within a median of 1 day before conventional coronary angiography, which served as the reference standard. MEASUREMENTS: Diagnostic performance of multislice CT and MRI. RESULTS: 129 patients completed the study. Altogether, 108 patients with 430 vessels could be examined with both multislice CT and MRI and were used for analysis. In the per-patient analysis, the sensitivity of multislice CT (92% [95% CI, 82% to 96%]) was significantly higher than that of MRI (74% [CI, 61% to 83%]; P = 0.013). The sensitivity for detecting clinically significant stenoses was 82% for multislice CT and 54% for MRI (P < 0.001). Specificity and negative predictive value of multislice CT and MRI in the per-vessel analysis were 90% versus 87% (P = 0.73) and 95% versus 90% (P = 0.032), respectively. The effective radiation dose used with multislice CT (mean, 12.3 mSv [SD, 1.4]) in a consecutive subgroup of 73 patients was not significantly different from that used with diagnostic cardiac catheterization (11.4 mSv [SD, 4.8]) (P = 0.169). Most patients (74%) indicated that they would prefer multislice CT for future diagnostic imaging (P < 0.001). LIMITATIONS: This was a single-center study with 129 patients. CONCLUSIONS: In patients referred for conventional coronary angiography, multislice CT compares favorably with MRI for noninvasive detection of coronary stenoses.

Coronary Angiography↗

Uterine fibroids: contrast-enhanced MR angiography to predict ovarian artery supply--initial experience.

PURPOSE: To prospectively evaluate the diagnostic performance of contrast material-enhanced magnetic resonance (MR) angiography in helping predict ovarian artery supply of uterine fibroids by using postembolization conventional aortography as the reference standard. MATERIALS AND METHODS: The protocol for the study was approved by the institutional review board, and each patient gave informed consent. Ninety consecutive women (mean age, 42.5 years; range, 33-63 years) underwent MR angiography before uterine artery embolization (UAE). The number and origin of the ovarian arteries were determined. Ovarian artery supply of fibroids was graded as very unlikely, possible, or very likely by using a scoring system based on a combination of MR angiographic findings. MR angiographic results were compared with those of conventional aortography performed after UAE in all patients and followed by selective angiography in case of a suspected ovarian artery supply of fibroids. Analysis of the association between MR angiographic grading and conventional angiography as the standard of reference was performed with a chi(2) trend test. Sensitivity and specificity, including exact 95% confidence intervals (CIs), of MR angiography were determined. RESULTS: MR angiography depicted 18 ovarian arteries (four bilateral, 10 unilateral), one with an atypical origin. Five ovarian arteries were classified as very likely; three, as possible; and 10, as very unlikely sources of arterial fibroid supply. Seven (39%) of 18 ovarian arteries detected at MR angiography were visible at conventional aortography. Fibroid supply was verified at selective angiography in five ovarian arteries in five (6%) of 90 patients. There was a strong association between MR angiographic grading and the results of conventional angiography (P = .002). Sensitivity of MR angiography in depicting ovarian artery supply (grade, possible or very likely) was 100% (five of five, 95% CI: 48%; 100%) and specificity was 77% (10 of 13, 95% CI: 46%; 95%). CONCLUSION: Contrast-enhanced MR angiography can help predict ovarian artery supply of uterine fibroids.

Adult↗

Focal liver lesions: SPIO-, gadolinium-, and ferucarbotran-enhanced dynamic T1-weighted and delayed T2-weighted MR imaging in rabbits.

PURPOSE: To compare a superparamagnetic iron oxide (SPIO), VSOP-C184, with a gadopentetate dimeglumine with regard to signal-enhancing effects on T1-weighted dynamic magnetic resonance (MR) images and with another SPIO contrast medium with regard to signal-reducing effects on delayed T2-weighted MR images. MATERIALS AND METHODS: All experiments were approved by the responsible Animal Care Committee. Twenty rabbits (five for each contrast agent and dose) implanted with VX-2 carcinoma were imaged at 1.5 T. VSOP-C184 at 0.015 and 0.025 mmol Fe/kg was compared with gadopentetate dimeglumine at 0.15 mmol Gd/kg and ferucarbotran at 0.015 mmol Fe/kg. The imaging protocol comprised a T1-weighted dynamic gradient-echo (GRE) MR before injection and at 6-second intervals for up to 42 seconds after injection and a T2-weighted turbo spin-echo MR before and 5 minutes after injection. Images were evaluated quantitatively, and contrast media were compared by using nonparametric analysis of variance. RESULTS: At dynamic T1-weighted GRE MR imaging with 0.015-mmol Fe/kg VSOP-C184, 0.025-mmol Fe/kg VSOP-C184, gadopentetate dimeglumine, and ferucarbotran, the median peak contrast-to-noise ratio (CNR) was 20.7 (25th percentile, 16.3; 75th percentile, 22.6), 24.2 (25th percentile, 19.3; 75th percentile, 28.5), 16.4 (25th percentile, 13.7; 75th percentile, 20.3), and 14.0 (25th percentile, 11.4; 75th percentile, 16.8), respectively. Both doses of VSOP-C184 yielded significantly higher CNR (P < .05) than the other two agents. At T2-weighted turbo spin-echo imaging with 0.015-mmol Fe/kg VSOP-C184, 0.025-mmol Fe/kg VSOP-C184, gadopentetate dimeglumine, and ferucarbotran, the median CNR was 15.0 (25th percentile, 13.4; 75th percentile, 21.3), 15.7 (25th percentile, 14.5; 75th percentile, 19.8), 11.3 (25th percentile, 8.2; 75th percentile, 12.2), and 15.7 (25th percentile, 12.5; 75th percentile, 22.4), respectively. There was no significant difference between VSOP-C184 and ferucarbotran; both had a significantly higher CNR than did gadopentetate dimeglumine. CONCLUSION: VSOP-C184 produces higher liver-to-tumor contrast at dynamic T1-weighted imaging than does gadopentetate dimeglumine; at delayed T2-weighted imaging, the contrast is comparable to that achieved with ferucarbotran.

Animals↗

Myocardial viability: assessment with three-dimensional MR imaging in pigs and patients.

PURPOSE: To prospectively evaluate the correlation between a three-dimensional (3D) delayed enhancement magnetic resonance (MR) imaging sequence and a two-dimensional (2D) delayed enhancement MR imaging sequence for noninvasive assessment of myocardial viability in pigs and patients. MATERIALS AND METHODS: The pig and patient studies were approved by the responsible authorities, and patients gave written informed consent. MR imaging was performed by using a rapid 3D inversion-recovery balanced steady-state free precession sequence and a 2D segmented inversion-recovery fast low-angle shot sequence as the reference standard. Fourteen pigs with reperfused (n=7) or nonreperfused (n=7) myocardial infarction and 17 patients (13 men, four women; mean age, 64.9 years+/-8.6 [standard deviation]) suspected of having myocardial infarction were included. Linear regression analysis and Bland-Altman analysis were used to compare the infarction volumes. RESULTS: In 10 of the 14 pigs the induction of myocardial infarction was successful. In these pigs, altogether 81 segments with myocardial infarction were demonstrated by both MR sequences, and agreement between the two sequences for classification of transmural extent of myocardial infarction was 99.7%. The infarction volume determined by using 3D MR imaging (4.64 cm3+/-2.48) in the pigs highly correlated with that of 2D MR imaging (4.65 cm3+/-2.39, r=0.989, P<.001) and that of staining by using triphenyltetrazolium chloride (4.67 cm3+/-2.44, r=0.996, P<.001). Thirteen of the 17 patients examined showed myocardial infarction in 34 myocardial segments with both sequences, and agreement between the two sequences for classification of transmural extent of myocardial infarction was 98.6%. In the patients, the infarction volume determined with both sequences highly correlated (9.71 cm3+/-7.47 for the 3D sequence vs 10.01 cm3+/-8.04 for the 2D sequence, r=0.982, P<.001). The breath-hold time necessary for the 3D MR imaging (21.0+/-2.3 seconds) was significantly shorter than that for 2D MR imaging (188.3+/-20.2 seconds, P<.001). CONCLUSION: Myocardial infarction volumes obtained with the 3D MR imaging sequence are highly correlated and in good agreement with volumes obtained with the 2D MR imaging standard approach and reduced the acquisition time by a factor of nine.

Animals↗

Alterations of the proton-T2 time in relaxed skeletal muscle induced by passive extremity flexions.

PURPOSE: To demonstrate reciprocal changes of the apparent proton-T2 time in the biceps and triceps due to passive contraction and extension of the muscle fibers. MATERIALS AND METHODS: The contraction state of the upper arm muscles of six healthy volunteers was passively changed by alternating the forearm position between the straight-arm position and an elbow flexion of 90 degrees. The relaxation of the muscle during passive contraction and extension was measured with the use of muscle electromyography (EMG) experiments. Spin-echo (SE) MRI with increasing echo times (TEs) of 12-90 msec was used to acquire the averaged signal decay of the segmented biceps and triceps. The apparent T2 was deduced using monoexponential least-square fitting. RESULTS: The median T2 alterations in biceps and triceps among all volunteers were found to be 1.2 and -1.3 msec in the straight and bent forearm positions, respectively. The confidence intervals (0.5 to 1.7 msec in biceps, and -2.6 to -1.1 msec in triceps) clearly indicate that proton-T2 in MR images is significantly (P < 0.05) prolonged with muscle contraction. CONCLUSION: The observed increase of the proton-T2 time was correlated with a passive contraction of skeletal muscle fibers. This passive effect can be attributed to changes in the intracellular water mobility corresponding to the well-known "active" T2 increase that occurs after stimulation of muscle.

Humans↗

Combination of free-breathing and breathhold steady-state free precession magnetic resonance angiography for detection of coronary artery stenoses.

PURPOSE: To analyze the incremental diagnostic value of a combination of two approaches (free-breathing and breathhold) vs. the sole free-breathing approach to coronary magnetic resonance angiography (CMRA) for detection of significant stenoses. MATERIALS AND METHODS: Thirty patients were consecutively included in this prospective trial. CMRA was performed on a 1.5-T MR scanner (Magnetom Sonata, Siemens) using a balanced steady-state free precession (SSFP) sequence during free-breathing (2.4 x 0.9 x 0.7 mm3). Breathholding acquisitions (3.0 x 1.5 x 0.7 mm3) were only performed in cases in which the quality of free-breathing CMRA precluded assessment. Patients with contraindications to CMRA, claustrophobia, or nonassessable images were not excluded from the assessment of diagnostic accuracy (intention-to-diagnose design). RESULTS: In 60% of all free-breathing coronary acquisitions the image quality was adequate for diagnostic assessment. For the remaining 40% of the cases, breathhold acquisitions were obtained. The sensitivity, specificity, nonassessable rate, and accuracy in identifying main coronary branches with significant stenoses using the combination of both breathing approaches and the free-breathing approach alone were 65% vs. 32%, 73% vs. 53%, 24% vs. 52%, and 71% vs. 46%, respectively (P < 0.001). CONCLUSION: In this consecutive cohort of patients, the combination of free-breathing and breathhold CMRA significantly improved diagnostic accuracy. Nevertheless, even this combination did not reach accuracies sufficient for routine clinical application.

Cohort Studies↗

Respiratory-triggered MRCP applying parallel acquisition techniques.

PURPOSE: To evaluate the influence of parallel imaging on the image quality of respiratory triggered magnetic resonance cholangiopancreatography (MRCP). MATERIALS AND METHODS: A total of 30 consecutive patients underwent MRCP applying a respiratory triggered T2-weighted (T2w) turbo spin-echo (TSE) sequence without and with parallel imaging (acceleration factor of 2). Acquisition times of both sequences were recorded. Quantitative evaluation included measurement of a contour sharpness index of two segments of the pancreaticobiliary tree as well as calculation of the relative contrast between ductal structures and organ parenchyma at four different segments. The qualitative evaluation was performed by two independent radiologists who graded overall image quality, depiction of eight segments of the pancreaticobiliary tree, and the frequency of artifacts. RESULTS: The application of parallel imaging significantly (P<0.05) reduced the acquisition time of the respiratory triggered MRCP sequence by 37.7% (six minutes and two seconds+/-one minute and 26 seconds vs. three minutes and 46 seconds+/-58 seconds). The quantitative and qualitative evaluation revealed no statistically significant differences between the two sequences (P>0.05). The frequency of artifacts was at the same level for both sequences as well. CONCLUSION: The application of parallel imaging for respiratory triggered MRCP significantly reduces the acquisition time without relevant influence on image quality.

Adult↗

Assessment of unspecific near-infrared dyes in laser-induced fluorescence imaging of experimental arthritis.

OBJECTIVE: The aim of the study is to evaluate in vivo fluorescence imaging of experimental inflammatory joint disease by applying two different near-infrared (NIR) dyes in a model of Borrelia-induced Lyme arthritis. MATERIALS AND METHODS: Forty mice, 20 with Lyme arthritis and 20 controls, were examined. Two nonspecific NIR carbocyanine dyes, indocyanine green (ICG) and a hydrophilic carbocyanine derivative (1,1'-bis-[4-sulfobutyl] indotricarbocyanine-5,5'-dicarboxylic acid diglucamide monosodium salt [SIDAG]), were administered intravenously at two doses. Fluorescence images were acquired before and during 120 seconds after injection of cyanine dyes. For both dyes, the area under the curve (AUC) was determined for the interval between 40 and 80 seconds after injection. In addition, the slope of the signal decrease was compared among animal groups. Results were compared with histological findings. RESULTS: The general temporal fluorescence intensity course for ICG was characterized by a rapid increase, with a peak at 40-50 seconds followed by a decrease; conversely for SIDAG, by a slow increase. AUC analysis for both dyes showed that the fluorescence signal differed significantly between controls and arthritic animals (P < .05). Within these groups, there were significant differences between the two doses investigated. ICG differed significantly between control and arthritic animals in the slope of the signal decrease for both doses investigated (P < .05). Histological examination showed early stages of inflammation in arthritic animals. CONCLUSIONS: NIR fluorescence imaging based on the pharmacokinetic behavior of ICG or SIDAG is a promising approach to detect inflammatory joint changes of experimental arthritis. Moreover, SIDAG is suited to differentiate inflammatory and noninflammatory joints 24 hours after dye application.

Animals↗

Contrast enhancement in electron beam tomography of the heart: comparison of a monomeric and a dimeric iodinated contrast agent in 59 patients.

RATIONALE AND OBJECTIVES: The aim of the study is to determine whether intravascular time-density course and visualization of the coronary arteries differ with use of a hyperosmolar monomeric versus an iso-osmolar dimeric contrast agent in electron beam tomography (EBT) of the heart. MATERIALS AND METHODS: Fifty-nine patients underwent EBT of the coronary arteries using the monomeric ioversol or the dimeric iodixanol at the same concentration of 320 mg I/mL. Contrast volume was determined relative to body surface area and injected over 40 seconds. Intravascular time-density curves were created for quantitative analysis. For qualitative assessment, visualization of coronary arteries on axial scans and three-dimensional reconstructions was scored. Patients were matched for contrast flow, transit time, and mean pulse rate for statistical analysis. RESULTS: Ioversol produced a significantly greater increase in intravascular density for up to 30 seconds after injection (P < .01) compared with iodixanol. No difference between the two contrast media was seen in the qualitative assessment. CONCLUSION: Monomeric and dimeric contrast media differ in their time-density curves at coronary EBT, a reason for which is not apparent. Qualitative evaluation of coronary arteries is not affected by this difference.

Area Under Curve↗

Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction.

PURPOSE: The objective of this study was to evaluate the image quality of a respiratory-triggered T2-weighted (T2w) turbo spin-echo (TSE) sequence for magnetic resonance cholangiopancreatography (MRCP) using a new method for respiratory triggering by tracking the motion of the right diaphragm [prospective acquisition correction (PACE) technique]. MATERIALS AND METHODS: Fifty consecutive patients underwent MRCP imaging applying breath-hold half-Fourier single-shot TSE sequences and the respiratory-triggered T2w TSE sequence. Qualitative evaluation grading the depiction of eight segments of the pancreaticobiliary tree and the frequency of artifacts was performed. Quantitative evaluation included calculation of the relative contrast (RC) between fluid-filled ductal structures and organ parenchyma at four segments. RESULTS: A significantly higher (P<.01) RC was measured for the respiratory-triggered T2w TSE sequence [maximum intensity projection (MIP)] for all of the four investigated segments (one of four segments for the MIP) of the pancreaticobiliary tree, as well as a significant (P<.01) improvement of visualization of all ductal segments compared with the breath-hold sequences. The frequency of artifacts was significantly lower (P<.01) compared with the breath-hold sequences. CONCLUSION: Respiratory-triggered MRCP using a T2w TSE sequence with PACE significantly improves image quality and may be included into the routine MRCP sequence protocol.

Adult↗

Contrast-enhanced magnetic resonance angiography of the lower extremities: standard-dose vs. high-dose gadodiamide injection.

PURPOSE: To compare the efficacy and safety of two different doses (0.1 and 0.3 mmol/kg of body weight [BW]) of gadodiamide for contrast-enhanced magnetic resonance angiography (ce-MRA) of the lower extremities with intraarterial digital subtraction angiography (IA-DSA). MATERIALS AND METHODS: A total of 30 patients with peripheral arterial occlusive disease underwent IA-DSA and ce-MRA from the aortic bifurcation down to the ankle. Patients were randomized to receive a total dose of 0.1 or 0.3 mmol/kg of BW gadodiamide (Omniscan, Amersham Buchler), administered intravenously as a series of three automatic bolus injections. Ce-MRA was performed with a 1.5-T system using a body phased-array coil, centered stepwise over the calf, thigh, and pelvic region. A fast T1-weighted, three-dimensional gradient-echo sequence was obtained before and after injection of the allocated dose. IA-DSA was performed using the Seldinger technique and a femoral approach. The vessels under investigation were divided into 31 segments, and ce-MRA and IA-DSA image sets were evaluated in a double-blind fashion for the presence of stenosis, presence of collateral vessels, vessel delineation, and overall image quality. Both dose groups were compared with regard to contrast index (CI) and signal- and contrast-to-noise ratios (SNR, CNR). The occurrence of adverse events or side effects was also documented. Sensitivity, specificity, and accuracy were calculated in relation to the results of stenosis grading. RESULTS: A total of 26 patients were entered in the efficacy evaluation, while all 30 patients were included in the safety assessment. The sensitivity, specificity, and accuracy for the 0.1 and 0.3 mmol/kg dose groups were 78.8%/93.0%/88.9% vs. 60.2.%/91.5%/83.2%, respectively. The detection of collaterals was similar to IA-DSA for the 0.3 mmol/kg dose group (30.2% vs. 27.4%), but was lower in the 0.1 mmol/kg dose group (27.3% vs. 12.3%). The high-dose gadodiamide injection proved to be superior to the 0.1 mmol/kg dose group with regard to vessel delineation and overall image quality (P = 0.007 and P = 0.002, respectively). The difference between the two dose groups regarding CI, SNR, and CNR was significant (P = 0.0001), in favor of the 0.3 mmol/kg dose group. No adverse events were observed in any of the patients. CONCLUSION: Ce-MRA with gadodiamide is safe and efficacious. Comparison of two different doses with IA-DSA as the standard of reference showed that the 0.3 mmol/kg dose is superior to the standard 0.1 mmol/kg dose with respect to contrast enhancement, vessel delineation, image quality, and detection of collaterals. However, the 0.1 mmol/kg dose was superior to the high dose in the grading of stenosis.

Aged↗

Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction.

PURPOSE: To evaluate a free-breathing navigator triggered T2-weighted turbo spin-echo sequence with prospective acquisition correction (T2w-PACE-TSE) for MRI of the upper abdomen in comparison to a conventional T2-weighted TSE (T2w-CTSE), a single-shot TSE (T2w-HASTE), and a T1-weighted gradient-echo sequence (T1w-FLASH). MATERIALS AND METHODS: A total of 40 consecutive patients were examined at 1.5 T using free-breathing T2w-PACE-TSE, free-breathing T2w-CTSE, and breath-hold T2w-HASTE and T1w-FLASH acquisition. Images were evaluated qualitatively by three radiologists regarding motion artifacts, liver-spleen contrast, depiction of intrahepatic vessels, the pancreas and the adrenal glands, and overall image quality on a four-point scale. Quantitative analysis of the liver-spleen contrast was performed. RESULTS: Depiction and sharpness of intrahepatic vessels were rated significantly better (P < 0.01) using T2w-PACE-TSE compared to T2w-CTSE and T2w-HASTE sequences. Significantly higher contrast values were measured for T2w-PACE-TSE images compared to T2w-CTSE, T2w-HASTE, and T1w-FLASH images (P < 0.01). Mean examination time of the T2w-PACE-TSE was 7.91 minutes, acquisition time of the T2w-CTSE sequence was 4.52 minutes. CONCLUSION: Prospective acquisition correction is an efficient method for reducing respiratory movement artifacts in T2w-TSE imaging of the upper abdomen. Compared to T2w-CTSE and T2w-HASTE sequences recognition of anatomical details and contrast can be significantly improved.

Abdomen↗

On the heating of inductively coupled resonators (stents) during MRI examinations.

Stents that have been implanted to preserve the results of vascular dilatation are frequently affected by in-stent restenosis, which ideally should be followed up by a noninvasive diagnostic modality. Active MRI stents can enable this kind of follow-up, while normal metallic stents can not. The prototype stents investigated in this study were designed as electric resonating circuits without a direct connection to the MR imager, and function as inductively coupled transmit coils. The model of a long solenoid coil is used to describe the additional power loss caused by such resonators. The theoretically estimated temperature increase is verified by measurements for different resonators and discussed for worst-case conditions. The RF power absorption of an active resonator is negligible compared to the total power absorbed during MRI. The local temperature increase observed for prototypes embedded in phantoms is in a range that excludes direct tissue damage. However, ruptures in the conducting structure of a resonator can cause hot spots, which may establish a high local temperature. This hazard can be reduced by designing resonators with a low quality (Q) factor or by setting the circuit slightly off resonance; however, this would lower the nominal amplification for which the resonator was designed.

Blood Vessel Prosthesis↗

Computer-assisted diagnosis of focal liver lesions on CT images evaluation of the Perceptron algorithm.

RATIONALE AND OBJECTIVE: The purpose of the study was to investigate a modified version of a so-called Perceptron algorithm in detecting focal liver lesions on CT scans. MATERIALS AND METHODS: The modified Perceptron algorithm is based on simulated annealing with a logarithmic cooling schedule and was implemented on a standard workstation. The algorithm was trained with 400 normal and 400 pathologic CT scans of the liver. An additional 100 normal and 100 pathologic scans were then used to test the detection of pathology by the algorithm. The total of 1000 scans used in the study were selected from the portal venous phase of upper abdominal CT examinations performed in patients with normal findings or hypovascularized liver lesions. The pathologic scans contained 1 to 4 focal liver lesions. For the preliminary version of the algorithm used in this study, it was necessary to define regions of interest that were converted to a matrix of 119 x 119. RESULTS: Training of the algorithm with 400 examples each of normal and abnormal findings took about 75 hours. Subsequently, the testing took several seconds for processing each scan. The diagnostic accuracy in discriminating scans with and without focal liver lesions achieved for the 200 test scans was approximately 99%. The error rate for pathologic and normal scans was comparable to results reported in the literature, which, however, were obtained for much smaller test sets. CONCLUSION: The modified Perceptron algorithm has an accuracy of close to 99% in detecting pathology on CT scans of the liver showing either normal findings or hypovascularized focal liver lesions.

Algorithms↗

Implementation of a rapid inversion-prepared dual-contrast gradient echo sequence for quantitative dynamic contrast-enhanced magnetic resonance imaging of the human prostate.

The first step in quantitative pharmacokinetic modeling is to determine the arterial input function (AIF) by deriving the contrast medium (CM) concentration from an appropriate imaging sequence by monitoring changes in either the amplitude or the phase signal of an accommodative artery. The bolus passage is best detected on T2- or T2*-weighted images, while extravasation is best assessed on T1-weighted images. Here, an imaging sequence is used that employs a parallel acquisition technique for the interleaved acquisition of an inversion-prepared T1-weighted image and a T1/T2*-mixed-weighted image for determination of the AIF. The sequence was applied in six patients with prostate cancer. A method is presented for quantifying the AIF derived from the signal intensity-time courses of both the T1/T2*-mixed-weighted and the T1-weighted image. Furthermore, in some patients the signal intensity-time course of the T1-weighted image exhibits flow-induced signal modulations. To reduce the effect of this flow-related signal enhancement the corresponding phase information was used. The sequence presented here has the potential to improve the quantification of the AIF at all time points and pharmacokinetic modeling of the CM dynamics of the prostate.

Algorithms↗

Hepatic steatosis in Dunnigan-type familial partial lipodystrophy.

OBJECTIVES: Characterization of familial clusters of subjects with metabolic derangements predisposing to hepatic steatosis and nonalcoholic steatohepatitis could facilitate genomic studies to identify risk factors for their development. Dunnigan-type familial partial lipodystrophy (FPLD) is an autosomal dominantly inherited disorder caused by mutations in the LMNA gene. Affected subjects have loss of subcutaneous fat from the extremities and symptoms similar to those characterizing the metabolic syndrome, including insulin resistance and dyslipidemia. The goal of this study was to determine the prevalence of steatosis in subjects with FPLD. METHODS: We examined 18 subjects from six families with FPLD for mutations in LMNA and analyzed plasma lipid and serum glucose concentrations. Liver ultrasound and serum aminotransferase activities were used as indicators of steatosis or steatohepatitis. In two subjects, histological examination of hepatic tissue was performed. RESULTS: All subjects had FPLD-causing mutations in LMNA. Plasma lipids were measured in 17 subjects, 16 of whom had hyperlipidemia and 14 presented with either documented insulin resistance or diabetes mellitus. Hepatic steatosis was present in 15 subjects who had ultrasound examinations and 9 of these had elevated serum aminotransferase activities. Liver biopsy confirmed steatosis in 2 subjects. CONCLUSIONS: Hepatic steatosis is part of the clinical phenotype of FPLD. This familial disorder may provide a human metabolic model system to facilitate genomic and environmental studies to determine risk factors for hepatic steatosis and nonalcoholic steatohepatitis.

Adipose Tissue↗