PubMed Health⌕ Search

Biomedical subjects

Matthias Taupitz

Publications and source records attributed to Matthias Taupitz.

At least 37 records · Page 2Linked to original sources

MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results.

The authors evaluated a magnetic resonance (MR) imaging-compatible biopsy device comprising a needle guide that can be visualized with MR imaging and manipulated mechanically from outside the MR unit. With approval from the local ethics committee and patient consent, this device was tested in 12 patients by using a closed 1.5-T MR unit and a body phased-array coil. Patients had elevated prostate-specific antigen levels (6-60 ng/mL) and one or more areas in the prostate that were suspicious for carcinoma at prebiopsy MR imaging. Biopsy was performed with transrectal access and with the patient prone. A 16-gauge MR imaging-compatible needle was successfully positioned with the device, and between six and nine tissue cores were obtained in each patient. In one patient, two suspicious basal areas could not be reached with the device. Histologic analysis showed prostate cancer in five patients and prostatitis in six. No complications were observed. The device enabled MR imaging-guided core-needle biopsy of prostate areas suspicious for cancer on MR images.

Aged↗

Urinary bladder cancer: preoperative nodal staging with ferumoxtran-10-enhanced MR imaging.

PURPOSE: To prospectively evaluate ferumoxtran-10-enhanced magnetic resonance (MR) imaging for nodal staging in patients with urinary bladder cancer. MATERIALS AND METHODS: Fifty-eight patients with proved bladder cancer were enrolled. Results of MR imaging performed before and after injection of ferumoxtran-10 were compared with histopathologic results in surgically removed lymph nodes. High-spatial-resolution three-dimensional T1-weighted magnetization-prepared rapid acquisition gradient-echo (voxel size, 1.4 x 1.4 x 1.4 mm) and T2*-weighted gradient-echo (voxel size, 0.8 x 0.8 x 3.0 mm) sequences were performed before and 24 hours after injection of ferumoxtran-10 (2.6 mg iron per kilogram of body weight). On precontrast images, lymph nodes were defined as malignant by using size and shape criteria (round node, >8 mm; oval, >10 mm axial diameter). On postcontrast images, nodes were considered benign if there was homogeneous decrease in signal intensity and malignant if decrease was absent or heterogeneous. Qualitative evaluation was performed on a node-to-node basis. Sensitivity, specificity, predictive values, and accuracy were evaluated with logistic regression analysis. RESULTS: In 58 patients, 172 nodes imaged with use of ferumoxtran-10 were matched and correlated with results of node dissection. Of these, 122 were benign and 50 were malignant. With nodal size and shape criteria, accuracy, sensitivity, specificity, and positive and negative predictive values on precontrast images were 92%, 76%, 99%, 97%, and 91%, respectively; corresponding values on postcontrast images were 95%, 96%, 95%, 89%, and 98%. In the depiction of pelvic metastases, sensitivity and negative predictive value improved significantly at postcontrast compared with those at precontrast imaging, from 76% to 96% (P < .001) and from 91% to 98% (P < .01), respectively. At postcontrast imaging, metastases (4-9 mm) were prospectively found in 10 of 12 normal-sized nodes (<10 mm); these metastases were not detected on precontrast images. Postcontrast images also showed lymph nodes that were missed at pelvic node dissection in two patients. CONCLUSION: Ferumoxtran-10-enhanced MR imaging significantly improves nodal staging in patients with bladder cancer by depicting metastases even in normal-sized lymph nodes.

Contrast Media↗

Assessment of myocardial infarction in pigs using a rapid clearance blood pool contrast medium.

Delayed enhancement MRI using extracellular contrast media allows reliable detection of myocardial infarction. If blood pool contrast media like P792 (Vistarem, Guerbet, France), in addition to improving coronary MR angiography, can be shown to also produce delayed enhancement in myocardial infarction they could improve the prerequisites for a comprehensive cardiac MR examination. In this study reperfused myocardial infarction in five minipigs was imaged with an inversion-recovery fast low-angle shot sequence using P792 (0.013 mmol Gd/kg) and the extracellular contrast medium Gd-DOTA (Dotarem, 0.1 mmol Gd/kg, Guerbet). The infarction size determined on MRI using P792 (7.55 +/- 2.31 cm(2)) highly correlated both with histomorphometry (7.81 +/- 2.18 cm(2), r = 0.991, P < 0.002) and with MRI using Gd-DOTA (7.85 +/- 2.35 cm(2), r = 0.978, P < 0.005). Bland-Altman analysis showed that the limit of agreement of MRI using P792 compared to histomorphometry was 3.3 +/- 7.6% of the infarction size. The contrast-to-noise ratio between infarcted and remote myocardium was not significantly different between Gd-DOTA (5.9 +/- 2.4) and P792 (4.4 +/- 1.1, P = 0.5). The blood pool contrast medium P792 allows reliable assessment of viability with good contrast and accuracy.

Animals↗

Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography: intraindividual comparison in an animal model.

OBJECTIVE: Comparison of coronary artery visualization by multislice spiral CT (MSCT) and electron-beam CT (EBCT). MATERIALS AND METHODS: Six minipigs underwent MSCT (collimation 4 x 1 mm, gantry rotation time 500 milliseconds, acquisition time per cardiac cycle 126 +/- 30 milliseconds) and EBCT (slice thickness 1.5 mm, acquisition time per scan 100 milliseconds). Visualized vessel length and contour sharpness was measured, contrast-to-noise ratios were calculated, and the frequency of motion artifacts were evaluated. RESULTS: MSCT depicted significantly longer segments of the coronary tree than EBCT (length: 248.8 vs. 222.8 mm; P < 0.05), delineated the vessel contours more sharply (slope of density curves: 219.2 vs. 160.2 DeltaHU/mm; P < 0.05), and had a higher contrast-to-noise ratio (13.4 vs. 7.3; P < 0.05). The frequency of motion artifacts did not differ between both modalities (94.7% vs. 95.7% of visualized vessel length; P > 0.05). CONCLUSIONS: Because its higher spatial resolution and lower image noise, MSCT seems to be superior to EBCT in the visualization of the coronary arteries. Despite different temporal resolutions motion artifacts seem to be similar with both modalities.

Animals↗

Magnetic resonance imaging of myocardial perfusion and viability using a blood pool contrast agent.

RATIONALE AND OBJECTIVES: A comprehensive cardiac magnetic resonance (MR) examination should comprise imaging of myocardial perfusion, viability, and the coronary arteries. Blood pool contrast agents (BPCAs) improve coronary MR angiography, whereas their potential for imaging of perfusion and viability is unknown. The abilities to noninvasively image myocardial perfusion and viability using the BPCA P792 (Guerbet, France) were tested in a closed-chest model of nonreperfused myocardial infarction in 5 pigs. MATERIALS AND METHODS: Two to 3 days after instrumentation, myocardial perfusion imaging with a saturation-recovery steady-state free precession technique and viability imaging with an inversion-recovery fast low-angle shot sequence were conducted on a 1.5-T MR scanner using the extracellular contrast agents (ECCA) Gd-DOTA (0.1 mmol Gd/kg) and blood pool contrast agent (BPCA) P792 (0.013 mmol Gd/kg). RESULTS: Perfusion defects were visualized in all pigs with good correlation between the ECCA and the BPCA (1.77 +/- 1.16 cm2 vs. 1.80 +/- 1.19 cm2, r = 0.959, P < 0.01). Reduced myocardial perfusion was detected using the ECCA up to 80 seconds after injection. In contrast, BPCA administration enabled visualization of perfusion defects on equilibrium perfusion imaging in all cases for 10 minutes. The size of myocardial infarction detected with viability MR imaging correlated well between the standard method (ECCA) and delayed-enhancement imaging with the BPCA (5.40 +/- 3.16 versus 5.52 +/- 3.13 cm3, r = 0.994, P < 0.002). CONCLUSIONS: The BPCA investigated in this study allows both reliable detection of perfusion defects on first pass and equilibrium perfusion imaging and characterization of viability after myocardial infarction. Thus, this contrast agent is suitable for a comprehensive cardiac MR examination.

Animals↗

Phase I clinical evaluation of citrate-coated monocrystalline very small superparamagnetic iron oxide particles as a new contrast medium for magnetic resonance imaging.

RATIONALE AND OBJECTIVES: To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. METHODS: A total of 18 healthy subjects received either VSOP-C184 (core diameter: 4 nm; total diameter: 7 +/- 0.15 nm; relaxivities in water at 0.47 T (T1) 18.7 and (T2) 30 L/(mmol*seconds)) at doses of 0.015, 0.045, or 0.075 mmol Fe/kg (n = 5 per dose) or placebo (n = 1 per dose) as intravenous injections. Physical status and vital parameters were recorded, blood samples were collected for clinical chemistry and relaxometry (0.94 T), and urinalyses were performed before and for up to 2 weeks after administration. RESULTS: No serious adverse events occurred. The most pronounced adverse events occurred in 2 subjects of the highest dose group 45-50 minutes after injection. These were a drop in blood pressure and a drop in oxygen saturation, which were considered to be possibly drug-related and rapidly resolved without medication. Otherwise, no relevant changes in vital and laboratory parameters were observed. The parameters of iron metabolism exhibited short-term, dose-related changes. The injection of VSOP-C184 decreased T1 relaxation time of blood below 100 milliseconds for 18 minutes after a dose of 0.045 mmol [corrected] Fe/kg and for 60 minutes after 0.075 mmol [corrected] Fe/kg. CONCLUSIONS: The favorable data on the safety, tolerability, and efficacy of VSOP-C184 justify further clinical phase II and III trials as a contrast medium for MRI.

Adult↗

Comparison of the iron oxide-based blood-pool contrast medium VSOP-C184 with gadopentetate dimeglumine for first-pass magnetic resonance angiography of the aorta and renal arteries in pigs.

RATIONALE AND OBJECTIVES: VSOP-C184 at a dose of 0.045 mmol Fe/kg has been shown to be an efficient blood pool contrast medium for equilibrium magnetic resonance angiography (MRA) that can be administered as a bolus. The present study was performed to determine whether VSOP-C184 is also suitable for first-pass MRA. MATERIALS AND METHODS: Fifteen MRA examinations at 1.5 T were performed in minipigs using a fast 3D fast low-angle shot (FLASH) sequence (repetition time = 4.5 ms, echo time = 1.7 ms, excitation angle = 25 degrees, matrix 256, body phased-array coil). The citrate-stabilized iron oxide preparation VSOP-C184 was investigated (total particle diameter: 7.0 +/- 0.15 nm; core size: 4 nm) and compared with gadopentetate dimeglumine (Gd-DTPA). The following doses were tested: VSOP-C184: 0.015, 0.025, and 0.035 mmol Fe/kg; Gd-DTPA: 0.1 and 0.2 mmol Gd/kg; n = 3 examinations/dose. Data were analyzed quantitatively (signal enhancement (ENH) and vessel edge definition (VED)) and qualitatively. RESULTS: First-pass MRA using the 3 doses of VSOP-C184 yielded the following ENH: aorta: 9.4 +/- 2.6; 12.31 +/- 1.2; 16.53 +/- 1.7; renal arteries: 7.6 +/- 2.2; 9.9 +/- 1.0; 13.2 +/- 0.5. The values for the 2 doses of Gd-DTPA were aorta: 12.9 +/- 1.0; 16.8 +/- 2.2; renal arteries: 11.2 +/- 1.23; 11.3 +/- 1.7. VED for the 3 doses of VSOP-C184 was aorta: 106.3 +/- 31.0; 135.3 +/- 58.8; 141.3 +/- 71.0; renal arteries: 102.2 +/- 24.3; 146.8 +/- 63.0; 126.9 +/- 37.6 and for the 2 doses of Gd-DTPA, aorta: 157.2 +/- 47.8; 164.2 +/- 36.8; renal arteries: 165.9 +/- 30.4; 170.3 +/- 38.2 respectively. The differences between VSOP-C184 and Gd-DTPA are clinically not relevant and statistically not significant (p > or = .05). Qualitative evaluation of image quality, contrast, and delineation of vessels showed the results obtained with VSOP-C184 at doses of 0.025 and 0.035 mmol Fe/kg to be similar to those of Gd-DTPA at 0.1 and 0.2 mmol Gd/kg. CONCLUSION: VSOP-C184 is suitable for first-pass MRA at doses of 0.025 and 0.035 mmol Fe/kg and thus, in addition to its blood pool characteristics, allows for selective visualization of the arteries without interfering venous signal.

Animals↗

Improved detection of focal liver lesions at MR imaging: multicenter comparison of gadoxetic acid-enhanced MR images with intraoperative findings.

PURPOSE: To evaluate the safety and efficacy of gadoxetic acid disodium-enhanced magnetic resonance (MR) imaging for the detection of focal liver lesions, with results of histopathologic examination and/or intraoperative ultrasonography used as a standard of reference. MATERIALS AND METHODS: One hundred sixty-nine patients who were known to have or suspected of having focal liver lesions and were scheduled for liver surgery were included in this study. Results in 131 patients could be included in the efficacy analysis. MR imaging was performed before and immediately and 20 minutes after bolus injection of 0.025 mmol/kg of the liver-specific hepatobiliary contrast agent gadoxetic acid. T1-weighted gradient-echo (with and without fat saturation and including dynamic data sets) and T2-weighted fast spin-echo/turbo spin-echo sequences were performed. All images were evaluated on site and by three independent and blinded off-site reviewers. Lesion matching based on the standard-of-reference results was performed. Differences in lesion detection with precontrast and with postcontrast MR images were assessed with the two-sided Wilcoxon signed rank test. RESULTS: Gadoxetic acid was well tolerated. In the on-site review, the number of patients in whom all lesions were correctly matched increased from 89 of 129 patients at precontrast MR imaging to 103 of 129 patients at postcontrast MR imaging. In the off-site evaluation, the number of patients in whom all lesions were correctly matched and the corresponding sensitivity values increased from 72 (55.8%), 68 (52.7%), and 66 (51.2%) with the precontrast images to 88 (68.2%), 69 (53.5%), and 76 (58.9%) with the postcontrast images for readers 1, 2, and 3, respectively. Two of the three blinded readers showed a statistically significant difference in lesion detection between precontrast and postcontrast MR imaging (P <.001 and P =.008). A large number of additionally correctly detected and localized lesions were smaller than 1 cm. CONCLUSION: MR imaging with gadoxetic acid is safe and improves lesion detection and localization.

Adult↗

Coronary artery disease: new insights and their implications for radiology.

Coronary artery disease (CAD) diminishes local, regional, or global blood supply to the heart and is most commonly caused by coronary atherosclerosis. New insights into the etiology of atherosclerosis suggest that CAD is an inflammatory disorder that responds well to modulation rather than an unchangeable chronic process. Since 75% of all acute coronary syndromes result from rupture of atherosclerotic plaques, factors causing rupture have a crucial role. Magnetic resonance imaging and CT have the potential to visualize the composition of coronary artery plaques and thus to identify plaques at risk. Considering the new insights into stunning and hibernation, myocardial late enhancement on MRI might provide pivotal information for therapeutic decision making among lysis therapy, catheter intervention, and bypass surgery. Exercise electrocardiography without or with right precordial leads, stress echocardiography, and stress scintigraphy are simple clinical procedures to identify CAD with high sensitivities of 67, 92, 76, and 88%, respectively. The MRI and CT have to be compared with these good results. Nevertheless, we are expecting that MRI and CT will replace the conventional diagnostic modalities, gain a central role in diagnosing patients with suspected CAD, and prove to be cost-effective in this regard.

Coronary Disease↗

Gadolinium-enhanced three-dimensional magnetic resonance angiography versus conventional digital subtraction angiography: which modality is superior in evaluating living kidney donors?

This study evaluates the correlation of magnetic resonance angiography (MRA) and digital subtraction angiography (DSA) with the operative vessel findings in living kidney donors. The intraoperative vessel findings of 52 living renal donors were compared with the preoperative diagnoses of each imaging technique. Sixty-seven arteries were found during explantation. Forty kidneys showed a single arterial blood supply, and 12 kidneys showed a multiple arterial blood supply. No advantage of either imaging method was found for arterial imaging. There were 55 veins identified during organ harvesting. MRA could not determine the venous system in one donor (1.9%) and failed to detect one small pole vein in another. DSA did not yield a venous diagnosis in seven patients (13.5%) and yielded misdiagnoses in four patients. The correct diagnosis of renal donor veins differed significantly in favor of MRA (kappa 0.79 vs. 0.45; P=0.008). MRA is superior to DSA in assessing the renal vasculature in living kidney donors.

Angiography↗

Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease: a prospective, multi-centre blinded comparison with digital subtraction angiography.

The purpose of this study was to compare moving-table three-dimensional contrast-enhanced magnetic resonance angiography (CE MRA), using 1.0-mol gadobutrol, with intra-arterial digital subtraction angiography (i.a. DSA) for evaluation of pelvic and peripheral arteries in patients with peripheral arterial occlusive disease. A total of 203 patients were examined in a prospective, multi-centre study at 1.0/1.5 T. Ten vessel segments of one leg were evaluated on-site and by three independent blinded reviewers off-site. One hundred eighty-two patients were evaluable in blinded reading. For pelvis and thigh, there was statistically significant diagnostic agreement between CE MRA and i.a. DSA on-site (94%) and off-site (86-88%). Overall, for detection of clinically significant stenoses, 93% sensitivity and 90% specificity were achieved in on-site evaluation, with 71-76 and 87-93% off-site; for detection of occlusion, sensitivity and specificity on-site were 91 and 97%, with 75-82 and 94-98% off-site. Evaluation was more sensitive on-site than off-site for detection of stenoses and occlusion, whereas specificity was similar. The CE MRA with 1.0-mol gadobutrol gave results comparable to those of i.a. DSA for the larger arteries of pelvis and thigh. Results for calf arteries were compromised by spatial resolution and technical limitations.

Angiography, Digital Subtraction↗

Disintegration and stepwise expulsion of a large uterine leiomyoma with restoration of the uterine architecture after successful uterine fibroid embolization: case report.

Uterine fibroid embolization (UFE) is a new minimally-invasive treatment option for leiomyomata of the uterus leading to symptomatic improvement and shrinkage of the fibroids. We present a case of restoration of the uterine architecture after disintegration and stepwise expulsion of infarcted leiomyoma tissue 7 months after UFE for leiomyoma-related menorrhagia.

Embolization, Therapeutic↗

A vascular stent as an active component for locally enhanced magnetic resonance imaging: initial in vivo imaging results after catheter-guided placement in rabbits.

RATIONALE AND OBJECTIVE: A vascular stent constructed as a high frequency resonator improves the local signal-to-noise ratio at magnetic resonance (MR) imaging. After catheter placement and intravascular expansion, the stent can be used as an inductively coupled coil for MRI. The imaging properties of this balloon-expandable active MRI stent (AMRIS) were evaluated after x-ray fluoroscopy guided placement in the abdominal aorta of five rabbits using MR angiography (MRA) and flow measurements. METHODS: The AMRIS was implanted in the abdominal aorta of five rabbits using a balloon catheter inserted through the common carotid artery. The rabbits were examined by MRA (3D fast low-angle shot) at 1.5 tesla before and after intravenous injection of an iron-oxide-based blood pool contrast medium (dose 50 micro mol Fe/kg) and flow measurements (ECG-triggered phase contrast cine gradient-echo sequence). Signal-to-noise ratios (SNR) were calculated and flow volume curves were generated. The in-stent increase in temperature was measured in vitro using a fiberoptic thermometry system. RESULTS: The SNR was 5.0 +/- 0.6 outside the stent and 23.2 +/- 14.1 within the stent ( < 0.0 5) in plain MRA, 19.5 +/- 5.0 outside and 30.7 +/- 8.2 within the stent ( < 0.05) in contrast enhanced MRA, and 5.8 +/- 1.6 and 13.9 +/- 5.9, respectively ( < 0.05) in the magnitude images of the flow measurements. Flow volume curves within and distal to the stent were comparable. CONCLUSIONS: The expandable active MRI stent produces local signal enhancement in MRA and MR flow measurements after catheter placement and thus may improve assessment of the stented vessel segment by MR imaging.

Animals↗

Effect of partial left ventriculectomy on left and right ventricular volumes and function as assessed with electron beam tomography: preliminary results.

Our objective was to determine if left ventricular reduction surgery affects left and right ventricular volumes and function. Twenty-three patients with end-stage heart failure underwent contrast-enhanced electron beam tomographic function studies before and twice after partial left ventriculectomy (PLV). The PLV was combined with other cardiosurgical procedures in 20 of 23 patients. Left and right ventricular enddiastolic volume (LVEDV, RVEDV), stroke volume (LVSV, RVSV), ejection fraction (LVEF, RVEF), and enddiastolic diameter (LVEDD, RVEDD) were determined by manual tracing of endo- and epicardial borders at enddiastole and endsystole. Patients were scanned 31 days (+/-34) before and 18 days (+/-13) and 8 months (+/-4) after PLV. Mean pre- and early and late postoperative values for LVEDV, LVSV, LVEF, and LVEDD were 387.9 ml (+/-125.5 ml), 255.6 ml (+/-79.3 ml; p<0.01), and 253.7 ml (+/-97.8 ml; p<0.05), 79.7 ml (+/-25.2 ml), 74.8 ml (+/-17.9; n.s.), and 79.1 ml (+/-26.5 ml; n.s.), 21.6% (+/-7.3%), 31.9% (+/-13.4%; p<0.05), and 34.1% (+/-14.1%; p<0.05), and 72.0 mm (+/-10.6 mm), 64.3 mm (+/-8.5 mm; p<0.05), and 63.5 mm (+/-9.4 mm; p<0.05), respectively. Mean pre- and postoperative values for RVEDV, RVSV, RVEF, and RVEDD were 177.7 ml (+/-72.8 ml), 172.4 ml (+/-59.2 ml; n.s.), and 178.9 ml (+/-60.8 ml; n.s.), 60.3 ml (+/-21.6 ml), 68.8 ml (+/-19.9 ml; n.s.), and 78.3 ml (+/-25.3 ml; n.s.), 38.1% (+/-15.4%), 43.7% (+/-16.3%; p<0.05), and 45.1% (+/-11.2%; n.s.), and 50.4 mm (+/-10.9 mm), 48.1 mm (+/-8.7 mm; n.s.), and 48.5 mm (+/-9.8 mm; n.s.), respectively. The PLV may induce a significant early reduction of left ventricular volumes and improvement of biventricular function; however, our results must be judged carefully as the majority of patients in this study underwent additional cardiosurgical procedures, the contributory effect of which on the overall outcome remains unclear.

Aged↗

Monomer-coated very small superparamagnetic iron oxide particles as contrast medium for magnetic resonance imaging: preclinical in vivo characterization.

RATIONALE AND OBJECTIVES: Preclinical in-vivo characterization of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184). METHODS: VSOP-C184 (core diameter: 4 nm; total diameter: 8.6 nm; relaxivities in water at 0.94 T (T1) 20.1 and (T2) 37.1 l/[mmol*sec]) was investigated to determine its pharmacokinetics, efficacy, acute single dose toxicity, repeated dose toxicity, and genotoxicity. RESULTS: The plasma elimination half-life at 0.045 mmol Fe/kg was 21.3 +/- 5.5 minutes in rats and 36.1 +/- 4.2 minutes in pigs, resulting in a T1-relaxation time of plasma of < 100 milliseconds for 30 minutes in pigs. The particles are mainly cleared via the phagocytosing system of the liver. MR angiography at a dose of 0.045 mmol Fe/kg shows an excellent depiction of the thoracic and abdominal vasculature in rats and of the coronary arteries in pigs. The LD50 in mice is > 17.9 mmol Fe/kg. A good tolerance and safety profile was found. CONCLUSIONS: The experiments indicate, that VSOP-C184 may be a well tolerated and safe contrast medium for MR imaging that can be effectively used for MR angiography including visualization of the coronary arteries.

Animals↗

In vitro characterization of two different ultrasmall iron oxide particles for magnetic resonance cell tracking.

RATIONALE AND OBJECTIVES: Comparison of two different ultrasmall superparamagnetic iron oxide (USPIO) particles in terms of their intracellular cell-labeling properties of macrophages and subsequent visualization by MR imaging. MATERIALS AND METHODS: Cultures containing the macrophage cell line P-388D1 were incubated with a neutral carboxydextran-coated USPIO preparation (DDM 43/34/103) or an acidic citrate-coated USPIO (VSOP-C125). Experiments were performed in which incubation concentration and duration were varied and phagocytosis and pinocytosis suppressed by specific inhibitors. In cell culture specimens iron content was measured quantitatively and signal intensities determined by in vitro MR imaging. RESULTS: VSOP-C125 is incorporated by cells much faster than DDM 43/34/103 and produces significantly higher final intracellular iron concentrations per cell (3420 vs. 727 ng/million cells). Both preparations show similar signal-reducing effects at MR imaging relative to the Fe content per cell. Intracellular USPIO has a much lower detection threshold at MR imaging (50/80 micromol/L) than extracellular USPIO in free solution (300 micromol/L). CONCLUSIONS: Citrate-coated USPIO particles VSOP-C125 appear to have more favorable properties for magnetic labeling of macrophages than the carboxydextran-coated USPIO preparation DDM 43/34/103.

Animals↗