Max E Valentinuzzi

Publications and source records attributed to Max E Valentinuzzi.

10 recordsLinked to original sources

Algorithm for identifying and separating beats from arterial pulse records.

BACKGROUND: This project was designed as an epidemiological aid-selecting tool for a small country health center with the general objective of screening out possible coronary patients. Peripheral artery function can be non-invasively evaluated by impedance plethysmography. Changes in these vessels appear as good predictors of future coronary behavior. Impedance plethysmography detects volume variations after simple occlusive maneuvers that may show indicative modifications in arterial/venous responses. Averaging of a series of pulses is needed and this, in turn, requires proper determination of the beginning and end of each beat. Thus, the objective here is to describe an algorithm to identify and separate out beats from a plethysmographic record. A secondary objective was to compare the output given by human operators against the algorithm. METHODS: The identification algorithm detected the beat's onset and end on the basis of the maximum rising phase, the choice of possible ventricular systolic starting points considering cardiac frequency, and the adjustment of some tolerance values to optimize the behavior. Out of 800 patients in the study, 40 occlusive records (supradiastolic- subsystolic) were randomly selected without any preliminary diagnosis. Radial impedance plethysmographic pulse and standard ECG were recorded digitizing and storing the data. Cardiac frequency was estimated with the Power Density Function and, thereafter, the signal was derived twice, followed by binarization of the first derivative and rectification of the second derivative. The product of the two latter results led to a weighing signal from which the cycles' onsets and ends were established. Weighed and frequency filters are needed along with the pre-establishment of their respective tolerances. Out of the 40 records, 30 seconds strands were randomly chosen to be analyzed by the algorithm and by two operators. Sensitivity and accuracy were calculated by means of the true/false and positive/negative criteria. Synchronization ability was measured through the coefficient of variation and the median value of correlation for each patient. These parameters were assessed by means of Friedman's ANOVA and Kendall Concordance test. RESULTS: Sensitivity was 97% and 91% for the two operators, respectively, while accuracy was cero for both of them. The synchronism variability analysis was significant (p < 0.01) for the two statistics, showing that the algorithm produced the best result. CONCLUSION: The proposed algorithm showed good performance as expressed by its high sensitivity. The correlation analysis demonstrated that, from the synchronism point of view, the algorithm performed the best detection. Patients with marked arrhythmic processes are not good candidates for this kind of analysis. At most, they would be singled out by the algorithm and, thereafter, to be checked by an operator.

Algorithms↗

Amplifier spurious input current components in electrode-electrolyte interface impedance measurements.

BACKGROUND: In Impedance Microbiology, the time during which the measuring equipment is connected to the bipolar cells is rather long, usually between 6 to 24 hrs for microorganisms with duplication times in the order of less than one hour and concentrations ranging from 10(1) to 10(7) [CFU/ml]. Under these conditions, the electrode-electrolyte interface impedance may show a slow drift of about 2%/hr. By and large, growth curves superimposed on such drift do not stabilize, are less reproducible, and keep on distorting all over the measurement of the temporal reactive or resistive records due to interface changes, in turn originated in bacterial activity. This problem has been found when growth curves were obtained by means of impedance analyzers or with impedance bridges using different types of operational amplifiers. METHODS: Suspecting that the input circuitry was the culprit of the deleterious effect, we used for that matter (a) ultra-low bias current amplifiers, (b) isolating relays for the selection of cells, and (c) a shorter connection time, so that the relays were maintained opened after the readings, to bring down such spurious drift to a negligible value. Bacterial growth curves were obtained in order to test their quality. RESULTS: It was demonstrated that the drift decreases ten fold when the circuit remained connected to the cell for a short time between measurements, so that the distortion became truly negligible. Improvement due to better-input amplifiers was not as good as by reducing the connection time. Moreover, temperature effects were insignificant with a regulation of +/- 0.2 [ degrees C]. Frequency did not influence either. CONCLUSION: The drift originated either at the dc input bias offset current (Ios) of the integrated circuits, or in discrete transistors connected directly to the electrodes immersed in the cells, depending on the particular circuit arrangement. Reduction of the connection time was the best countermeasure.

Amplifiers, Electronic↗

Hematocrit measurement by dielectric spectroscopy.

Based on permittivity changes, a new method to measure hematocrit (HCT) in extracorporeal blood systems is presented. Human blood samples were tested at different HCT levels pairing the values of permittivity change, obtained by means of a commercial impedance analyzer, with traditional centrifugation measurements. Data were correlated using both linear and nonlinear regression. When using the lineal model, the comparison yielded a high correlation coefficient (r = 0.99). Theoretical simplifications suggest that the method is independent of changes in the conductivities of the intracellular and extracellular compartments. The influence of osmolarity and conductivity of the extracellular compartment was analyzed. It is shown that HCT can be predicted within an error lower than 5% when those parameters changed as much as 1 mS/cm and 50 mOsm/kg, respectively. Thus, the method appears as valid and viable showing good possibilities in applications such as renal dialysis.

Algorithms↗

Comparative analysis of hematocrit measurements by dielectric and impedance techniques.

In a previous paper, a new dielectric technique was used to estimate hematocrit (HTC) in extracorporeal blood circulation systems, independently of plasma conductivity or osmolarity. Although many impedance techniques have been formerly proposed in the literature, none has been evaluated against plasma conductivity and osmolarity. Herein, we estimate HTC based on permittivity changes and also with other four techniques found in the literature. Besides, the error incurred in each is also studied when plasma conductivity and osmolarity changed as much as 1 mS/cm and 50 mOsm/kg, respectively. The dielectric (permittivity) technique has an error close to 5.4%, while the others showed both tendencies, i.e., lower error (2.5%, two of them) and higher error (8.6% and 16.3%, the other two). The dielectric technique, even though did not produce the lowest error, provides a well-described physical model along with simple instrumentation.

Algorithms↗

Honor thy dog.

Explore the source record for details and available documents.

Animals↗