Amplifier spurious input current components in electrode-electrolyte interface impedance measurements.

Abstract

BACKGROUND: In Impedance Microbiology, the time during which the measuring equipment is connected to the bipolar cells is rather long, usually between 6 to 24 hrs for microorganisms with duplication times in the order of less than one hour and concentrations ranging from 10(1) to 10(7) [CFU/ml]. Under these conditions, the electrode-electrolyte interface impedance may show a slow drift of about 2%/hr. By and large, growth curves superimposed on such drift do not stabilize, are less reproducible, and keep on distorting all over the measurement of the temporal reactive or resistive records due to interface changes, in turn originated in bacterial activity. This problem has been found when growth curves were obtained by means of impedance analyzers or with impedance bridges using different types of operational amplifiers. METHODS: Suspecting that the input circuitry was the culprit of the deleterious effect, we used for that matter (a) ultra-low bias current amplifiers, (b) isolating relays for the selection of cells, and (c) a shorter connection time, so that the relays were maintained opened after the readings, to bring down such spurious drift to a negligible value. Bacterial growth curves were obtained in order to test their quality. RESULTS: It was demonstrated that the drift decreases ten fold when the circuit remained connected to the cell for a short time between measurements, so that the distortion became truly negligible. Improvement due to better-input amplifiers was not as good as by reducing the connection time. Moreover, temperature effects were insignificant with a regulation of +/- 0.2 [ degrees C]. Frequency did not influence either. CONCLUSION: The drift originated either at the dc input bias offset current (Ios) of the integrated circuits, or in discrete transistors connected directly to the electrodes immersed in the cells, depending on the particular circuit arrangement. Reduction of the connection time was the best countermeasure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Carmelo J Felice, Rossana E Madrid, Max E Valentinuzzi. 2005-03-29. Amplifier spurious input current components in electrode-electrolyte interface impedance measurements.. https://doi.org/10.1186/1475-925x-4-22

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A biopolymer transistor: electrical amplification by microtubules.

Microtubules (MTs) are important cytoskeletal structures engaged in a number of specific cellular activities, including vesicular traffic, cell cyto-architecture and motility, cell division, and information processing within neuronal processes. MTs have also been implicated in higher neuronal functions, including memory and the emergence of "consciousness". How MTs handle and process electrical information, however, is heretofore unknown. Here we show new electrodynamic properties of MTs. Isolated, taxol-stabilized MTs behave as biomolecular transistors capable of amplifying electrical information. Electrical amplification by MTs can lead to the enhancement of dynamic information, and processivity in neurons can be conceptualized as an "ionic-based" transistor, which may affect, among other known functions, neuronal computational capabilities.

Amplifiers, Electronic↗

Numerical study of wavelength-swept semiconductor ring lasers: the role of refractive-index nonlinearities in semiconductor optical amplifiers and implications for biomedical imaging applications.

Recent results have demonstrated unprecedented wavelength-tuning speed and repetition rate performance of semiconductor ring lasers incorporating scanning filters. However, several unique operational characteristics of these lasers have not been adequately explained, and the lack of an accurate model has hindered optimization. We numerically investigated the characteristics of these sources, using a semiconductor optical amplifier (SOA) traveling-wave Langevin model, and found good agreement with experimental measurements. In particular, we explored the role of the SOA refractive-index nonlinearities in determining the intracavity frequency-shift-broadening and the emitted power dependence on scan speed and direction. Our model predicts both continuous-wave and pulse operation and shows a universal relationship between the output power of lasers that have different cavity lengths and the filter peak frequency shift per round trip, therefore revealing the advantage of short cavities for high-speed biomedical imaging.

Amplifiers, Electronic↗

Influence of recording instrumentation on the stimulus artifact tail in the surface acquisition of somatosensory evoked potentials.

Surface recorded somatosensory evoked potentials (SEPs) are neural signals elicited by an external stimulus. In the case of electrically induced SEPs, the artifact generated by the stimulation process can severely distort the signal. The artifact is characterized by a large impulse followed by a slowly decaying tail. In some cases, the artifact tail often lasts well into the initiation of the SEP making the determination of absolute latency very difficult. While the literature often states that the recording instrumentation plays a part in the generation of this artifact tail, no firm evidence has ever been presented. In this work, comparisons are made between three instrumentation systems (BJT, JFET and CMOS) with differing input impedances in an attempt to quantify the effects on the artifact tail. The conclusions from this investigation show that there is no significant interaction between the input impedance of the recording instrumentation and the duration of the artifact tail. Each amplifier type produced results with no significant statistical differences. It was also found that while stimulation amplitude has a weak effect on the artifact tail, the greatest contribution to variation has an inter-subject origin. Consequently, it is concluded that the time constant of the artifact tail must originate from other sources that are subject dependent.

Amplifiers, Electronic↗