PubMed Health⌕ Search

Biomedical subjects

Mehran Javanbakht

Publications and source records attributed to Mehran Javanbakht.

6 recordsLinked to original sources

Novel PVC-based copper(II) membrane sensor based on 2-(1'-(4'-(1''-hydroxy-2''-naphthyl)methyleneamino)butyl iminomethyl)-1-naphthol.

A copper(II) ion-selective PVC membrane sensor based on 2-(1'-(4'-(1''-hydroxy-2''-naphthyl)methyleneamino)butyl iminomethyl)-1-naphthol (BHNB) as a novel Schiff base containing a sensing material has been successfully developed. The sensor exhibits a good linear response of 29 mV per decade within the concentration range of 10(-1)-10(-6) M of Cu2+. The sensor shows good selectivity for copper(II) ion in comparison with alkali, alkaline earth, transition and heavy metal ions. The BHNB-based sensor is suitable for use with aqueous solutions of pH 3.5-7.0 and displays minimal interference by Sr(II), Cd(II), Hg(II), Zn(II) and Pb(II), which are known to interfere with other previously suggested electrodes. The proposed membrane electrode was used as a sensor for determining the Cu(II) content in black tea samples. It was also applied as an indicator electrode in the potentiometric titration of Cu2+ ions with EDTA.

Copper↗

Novel potentiometric membrane sensor for the determination of trace amounts of chromium(III) ions.

A plasticized Cr3+ ion sensor by incorporating 2,3,8,9-tetraphenyl-1,4,7,10-tetraazacyclododeca-1,3,7,9-tetraene (TTCT) ionophore exhibits a good potentiometric response for Cr3+ over a wide concentration range (1.0 x 10(-6)-1.0 x 10(-1) M) with a slope of 19.5 mV per decade. The sensor response is stable for at least three months. Good selectivity for Cr3+ in comparison with alkali, alkaline earth, transition and heavy metal ions, and minimal interference are caused by Li+, Na+, K+, Co2+, Hg2+, Ca2+, Pb2+ and Zn2+ ions, which are known to interfere with other chromium membrane sensors. The TTCT-based electrode shows a fast response time (15 s), and can be used in aqueous solutions of pH 3-5.5. The proposed sensor was used for the potentiometric titration of Cr3+ with EDTA and for a direct potentiometric determination of Cr3+ content in environmental samples.

Chromium↗

Novel membrane potentiometric sulfate ion sensor based on zinc-phthalocyanine for the quick determination of trace amounts of sulfate.

Poly(vinyl chloride) (PVC) based membranes of zinc-phthalocyanine (ZPC) with hexadecyltrimethylammonium bromide (HTAB) as a cation excluder, and dibutyl phthalate (DBP) and benzyl acetate (BA) as plasticizing solvent mediators were prepared and investigated as a SO4(2-) selective electrode. The best performance was observed with a membrane having a composition of ZPC-PVC-HTAB-BA in a ratio of 5%:32%:3%:60%, which works well over a wide concentration range (1.0 x 10(-2) - 1.0 x 10(-6) M) with a Nemstian slope of -29.2 mV per decade of activity, between the pH values of 2.0 to 7.0. This sensor shows a very fast response time of 10 s, and can be used over a period of 2 months with good reproducibility. The proposed sensor displays excellent selectivity for SO4(2-) over a large number of common inorganic anions. The sensor has been successfully applied for the direct and indirect determination of sulfate and zinc in zinc sulfate tablets, respectively. It was also used as an indicator electrode in the potentiometric titration of sulfate ions with barium ions.

Journal Article↗

A 9,10-anthraquinone derivative having two propenyl arms as a neutral ionophore for highly selective and sensitive membrane sensors for copper(II) ion.

New polymeric membrane (PME) and coated graphite (CGE) copper(II)-selective electrodes based on 1-hydroxy-2-(prop-2'-enyl)-4-(prop-2'-enyloxy)-9,10-anthraquinone were prepared. The electrodes reveal linear emf-pCu2+ responses over wide concentration ranges (1.0 x 10(-5)-1.0 x 10(-1) M with a slope of 27.3 mV decade-1 for PME and 8.0 x 10(-8)-5.0 x 10(-2) M with a slope of 29.1 mV decade-1 for CGE) and very low limits of detection (8.0 x 10(-6) M for PME and 5.0 x 10(-8) M for CGE). The potentiometric response is independent of the pH of the test solution in the pH range 3.0-6.0. The proposed electrodes possess very good selectivities over a wide variety of other cations, including alkali, alkaline earth, transition and heavy metal ions, the selectivity coefficients for the CGE being much improved over those for the PME. The electrodes were used as indicator electrodes in the potentiometric titration of Cu2+ and in the recovery of copper ions from wastewater.

Alkenes↗

Determination of SCN- in urine and saliva of smokers and non-smokers by SCN(-)-selective polymeric membrane containing a nickel(II)-azamacrocycle complex coated on a graphite electrode.

The construction, performance characteristics, and application of a novel polymeric membrane coated on a graphite electrode with unique selectivity towards SCN- are reported. The electrode was prepared by incorporating Ni(II)-2,2,4,9,9,11-hexamethyltetraazacyclotetradecanediene perchlorate into a plasticized poly(vinyl chloride) membrane. The influences of membrane composition, pH and foreign ions were investigated. The electrode displays a near Nernstian slope (-57.8 mV decade-1) over a wide concentration range of 1 x 10(-7)-1 x 10(-1) M of SCN- ion. The electrode has a detection limit of 4.8 x 10(-8) M (2.8 ng/cm3) SCN- and shows response times of about 15 s and 120 s for low to high and high to low concentration sequences, respectively. The proposed sensor shows high selectivity towards SCN- over several common organic and inorganic anions. The electrode revealed a great enhancement in selectivity coefficients and detection limit for SCN-, in comparison with the previously reported electrodes. It was successfully applied to the direct determination of SCN- in milk and biological samples, and as an indicator electrode in titration of Ag+ ions with thiocyanate.

Aza Compounds↗

Sulfate-selective PVC membrane electrode based on a strontium Schiff's base complex.

A strontium Schiff's base complex (SS) can be used as a suitable ionophore to prepare a sulfate-selective PVC-based membrane electrode. The use of oleic acid (OA) and hexadecyltrimethylammonium bromide (HTAB), as additives, and nitrobenzen (NB), dibutyl phthalate (DBP) and benzyl acetate (BA) as solvent mediators, were investigated. The best performance was observed with a membrane composition PVC: NB: SS: HTAB of 30%: 62%: 5%: 3% ratio. The resulting sensor works well over a wide concentration range (1.0 x 10(-2)-1.0 x 10(-6) M) with a Nernstian slope of -29.2 mV per decade of sulfate activity over a pH range 4.0-7.0. The limit of detection of the electrode is 5 x 10(-7) M. The proposed sensor shows excellent discriminating ability toward SO4(2-) ions with regard to many anions. It has a fast response time of about 15 s. The membrane electrode was used to the determination of zinc in zinc sulfate tablets. The sensor was also used as an indicator electrode in the potentiometric titration of SO4(2-) against barium ion.

Ion-Selective Electrodes↗