PubMed Health⌕ Search

PubMed · 12940601

Sulfate-selective PVC membrane electrode based on a strontium Schiff's base complex.

Abstract

A strontium Schiff's base complex (SS) can be used as a suitable ionophore to prepare a sulfate-selective PVC-based membrane electrode. The use of oleic acid (OA) and hexadecyltrimethylammonium bromide (HTAB), as additives, and nitrobenzen (NB), dibutyl phthalate (DBP) and benzyl acetate (BA) as solvent mediators, were investigated. The best performance was observed with a membrane composition PVC: NB: SS: HTAB of 30%: 62%: 5%: 3% ratio. The resulting sensor works well over a wide concentration range (1.0 x 10(-2)-1.0 x 10(-6) M) with a Nernstian slope of -29.2 mV per decade of sulfate activity over a pH range 4.0-7.0. The limit of detection of the electrode is 5 x 10(-7) M. The proposed sensor shows excellent discriminating ability toward SO4(2-) ions with regard to many anions. It has a fast response time of about 15 s. The membrane electrode was used to the determination of zinc in zinc sulfate tablets. The sensor was also used as an indicator electrode in the potentiometric titration of SO4(2-) against barium ion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mohammad Reza Ganjali, Parviz Norouzi, Mahmood Gol-Mohammadi, Farhang Mizani, Tahereh Poursaberi, Masoud Salavati-Niasari, Mojtaba Shamsipur, Morteza Hosseini, Mehran Javanbakht. Sulfate-selective PVC membrane electrode based on a strontium Schiff's base complex.. https://pubmed.ncbi.nlm.nih.gov/12940601/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development of an array of ion-selective microelectrodes aimed for the monitoring of extracellular ionic activities.

In this study, we present the development and the characterization of a generic platform for cell culture able to monitor extracellular ionic activities (K+, NH4+) for real-time monitoring of cell-based responses, such as necrosis, apoptosis, or differentiation. The platform for cell culture is equipped with an array of 16 silicon nitride micropipet-based ion-selective microelectrodes with a diameter of either 2 or 6 microm. This array is located at the bottom of a 200-microm-wide and 350-microm-deep microwell where the cells are cultured. The characterization of the ion-selective microelectrode arrays in different standard and physiological solutions is presented. Near-Nernstian slopes were obtained for potassium- (58.6 +/- 0.8 mV/pK, n = 15) and ammonium-selective microelectrodes (59.4 +/- 3.9 mV/pNH4, n = 13). The calibration curves were highly reproducible and showed an average drift of 4.4 +/- 2.3 mV/h (n = 10). Long-term behavior and response after immersion in physiological solutions are also presented. The lifetime of the sensors was found to be extremely long with a high recovery rate.

Ion-Selective Electrodes↗

In-soil potassium sensor system.

A potentiometric sensor system based on potassium ion-selective electrodes was developed for agricultural purposes. Sensors were built using PVC ion-selective membranes over an inner solid contact prepared with graphite-epoxy composites. A copper plate was used as a reference electrode. A two-stage electronic circuit composed of current and voltage amplifiers was designed to interface the sensors to a distributed data acquisition system. Three ion-selective sensors and three off-the-shelf temperature sensors and their associated circuits were mounted in a PVC tube to set up a soil probe. The electronic controls were placed in an airtight box fixed at the upper part of the probe. The system was evaluated in the field, where the sensors presented sensibility within the range of 69-71 mV dec(-)(1). Extracts of soil samples were analyzed by a current flame photometry approach, and the results, compared with the probe measurements, showed a linear relationship (r (2) = 0.992 and 0.995, respectively, to 5 and 20 cm depths), which implies viability and instrumentation reliability for agricultural applications.

Ion-Selective Electrodes↗

Rotating disk potentiometry for inner solution optimization of low-detection-limit ion-selective electrodes.

The extent of optimization of the lower detection limit of ion-selective electrodes (ISEs) can be assessed with an elegant new method. At the detection limit (i.e., in the absence of primary ions in the sample), one can observe a reproducible change in the membrane potential upon alteration of the aqueous diffusion layer thickness. This stir effect is predicted to depend on the composition of the inner solution, which is known to influence the lower detection limit of the potentiometric sensor dramatically. For an optimized electrode, the stir effect is calculated to be exactly one-half the value of the case when substantial coextraction occurs at the inner membrane side. In contrast, there is no stir effect when substantial ion exchange occurs at the inner membrane side. Consequently, this experimental method can be used to determine how well the inner filling solution has been optimized. A rotating disk electrode was used in this study because it provides adequate control of the aqueous diffusion layer thickness. Various ion-selective membranes with a variety of inner solutions that gave different calculated concentrations of the complex at the inner membrane side were studied to evaluate this principle. They contained the well-examined silver ionophore O,O' '-bis[2-(methylthio)ethyl]-tert-butylcalix[4]arene, the potassium ionophore valinomycin, or the iodide carrier [9]mercuracarborand-3. Stir effects were determined in different background solutions and compared to theoretical expectations. Correlations were good, and the results encourage the use of such stir-effect measurements to optimize ISE compositions for real-world applications. The technique was also found to be useful in estimating the level of primary ion impurities in the sample. For an iodide-selective electrode measured in phosphoric acid, for example, apparent iodide impurity levels were calculated as 5 x 10(-10) M.

Ion-Selective Electrodes↗