PubMed Health⌕ Search

Biomedical subjects

Michael Bruegmann

Publications and source records attributed to Michael Bruegmann.

3 recordsLinked to original sources

Interventional atrial septal defect closure using a totally bioresorbable occluder matrix: development and preclinical evaluation of the BioSTAR device.

OBJECTIVES: We sought to test the hypothesis that interventional atrial septal defect (ASD) closure can be performed safely and effectively using a bioresorbable occluder matrix. BACKGROUND: The ideal septal occluder scaffold should promote the healthiest and most complete healing response while eventually facilitating the full resorption of the material and leaving "native" tissue behind, thus minimizing the potential for future complications from chronic foreign body and maintaining the possibility for later unobstructed transseptal access to the left atrium. METHODS: The STARFlex occluders (NMT Medical Inc., Boston, Massachusetts) were modified by substituting the conventional polyester fabric for a bioengineered, acellular type-I collagen matrix derived from porcine submucosa with a heparin-coated surface (BioSTAR occluder, NMT Medical Inc.). Comparative transcatheter closure of ASDs was performed in young sheep (n = 36). Gross pathology and histopathology were obtained after follow-up periods ranging from 7 days to 2 years. RESULTS: The STARFlex (control) devices were encapsulated time-dependently by ingrown fibrous tissue. Histology showed a mild but chronically persisting foreign body reaction. By contrast, BioSTAR devices exhibited a mild-to-moderate transient cellular immune response. Heparin coating of the BioSTAR surface improved the biocompatibility of the device by reducing surface thrombogencity. A remodeling process of the collagen scaffold, starting after 30 days in vivo, resulted in the full replacement of the matrix by host tissue after 2 years of follow-up. CONCLUSIONS: The BioSTAR device is the first septal occluder with a totally bioresorbable matrix that is fully replaced by host tissue during the healing process. The promising results of this study support testing of the BioSTAR device in clinical trials.

Absorbable Implants↗

Degradation of tungsten coils implanted into the subclavian artery of New Zealand white rabbits is not associated with local or systemic toxicity.

OBJECTIVE: To assess whether corrosion of tungsten coils is related to residual shunting and to evaluate whether elevated tungsten serum levels are associated with local or systemic toxicity. METHODS: Tungsten coils (SPI, Balt, France) were implanted into the subclavian artery of New Zealand white rabbits leading to a residual high-flow shunt in 5/10 rabbits. Serial serum tungsten levels, complete blood count and clinical chemistry were analysed prior to the implantation as well as 15 min, 2 and 4 months thereafter. After 4 months the rabbits underwent repeat angiography before they were sacrificed and the internal organs were evaluated histopathologically. RESULTS: Mean tungsten levels rose from 0.48 microg/l prior to the implantation to 12.4 microg/l 4 months post-implantation. The rise in serum tungsten levels was neither associated with residual shunting present at the time of implantation nor with residual shunting at the time of explantation. One animal had to be sacrificed because of non-resolving palsy of the upper extremity. The remaining animals had an uneventful clinical course with no signs of toxicity of the elevated tungsten levels. Histological examination revealed no evidence of local or systemic toxicity of the tungsten coils. CONCLUSION: Tungsten coils corrode and lead to a steady increase in serum tungsten levels starting as early as 15 min after implantation. Residual shunting does not seem to influence the kinetics of corrosion of tungsten coils. Despite markedly elevated serum tungsten levels 4 months after implantation degradation of tungsten coils is not associated with local or systemic toxicity.

Animals↗

A new biological matrix for septal occlusion.

The ideal septal occluder scaffold should promote the healthiest and most complete healing response possible while eventually facilitating the full resorption of the material, leaving "native" tissue behind. An excellent biocompatibility of the scaffold tissue is a prerequisite for quick, complete, and firm ingrowth of the device, optimizing outcomes and minimizing the potential for complications. Intestinal collagen layer (ICL) is a highly purified (acellular) bioengineered type-1 collagen derived from porcine submucosa. It is gradually resorbed by the host organism and subsequently replaced by the host tissue. CardioSEAL occluders were modified by substituting the conventional polyester fabric for an intestinal collagen layer (ICL). Percutaneous transcatheter closure of interventionally created atrial septal defects was performed in lambs using these modified occluders. A complete pathomorphological investigation including histology was carried out after 2, 4, and 12 weeks follow-up. Standard CardioSEAL implants served as a control group. After 2 weeks in vivo the devices were already covered completely by neo-endothelium. Compared with the conventional synthetic scaffold, ICL devices showed a quicker endothelialization, decreased thrombogenicity, and superior biocompatibility with no significant cellular infiltration observed in the histology of explants with ICL fabrics. After 3 months in vivo the collagen layer remained mechanically intact, but began to show the first histological signs of mild disintegration, gradual resorption, and remodeling. In conclusion, short-term results from preliminary in vivo experiments using a bioengineered collagen matrix as the occluder tissue scaffold showed excellent biocompatibility. This resulted in superior overall results: quicker endothelialization, a decreased thrombogenicity, and decreased immunological host response.

Absorbable Implants↗