PubMed Health⌕ Search

Biomedical subjects

Michael C Murphy

Publications and source records attributed to Michael C Murphy.

6 recordsLinked to original sources

Fabrication of DNA microarrays onto polymer substrates using UV modification protocols with integration into microfluidic platforms for the sensing of low-abundant DNA point mutations.

We describe the microfabrication and operational characteristics of a simple flow-through biochip sensor capable of detecting low abundant point mutations in K-ras oncogenes from genomic DNA, which carry high diagnostic value for colorectal cancers. The biochip consisted of an allele-specific ligase detection reaction (LDR) coupled to a universal array for interrogating multiple mutations simultaneously from a clinical sample. The integrated sensing platform was micro-manufactured from two different polymers, polycarbonate, PC, which was used for the LDRs, and poly(methyl methacrylate), PMMA, which was used to build the microarray. Passive elements were hot embossed into the PC and PMMA microchips and then, the chips assembled into a three-dimensional architecture with the interconnect fabricated from an elastomer, poly(dimethylsiloxane), PDMS, to produce a leak-free connection between the biochips. The array in PMMA was produced using a photomodification process, which involved three steps; (1) UV (254 nm) exposure of the polymer surface; (2) EDC coupling of amine-terminated oligonucleotide probes to the surface (via an amide bond) and; (3) washing of the surface. The LDR/hybridization flow-through biochip performed the entire assay at a relatively fast processing speed: 6.5 min for on-chip LDR, 10 min for washing, and 2.6 min for fluorescence scanning (total processing time=19.1 min) and could screen multiple mutations simultaneously for high throughput applications at a level of one mutant sequence in 100 wild-type sequences.

Biosensing Techniques↗

Ligase detection reaction/hybridization assays using three-dimensional microfluidic networks for the detection of low-abundant DNA point mutations.

We have fabricated a flow-through biochip assembly that consisted of two different microchips: (1) a polycarbonate (PC) chip for performing an allele-specific ligation detection reaction (LDR) and (2) a poly(methyl methacrylate) (PMMA) chip for the detection of the LDR products using an universal array platform. The operation of the device was demonstrated by detecting low-abundant DNA mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. The PC microchip was used for the LDR in a continuous-flow format, in which two primers (discriminating primer that carried the complement base to the mutation being interrogated and a common primer) that flanked the point mutation and were ligated only when the particular mutation was present in the genomic DNA. The miniaturized reactor architecture allowed enhanced reaction speed due to its high surface-to-volume ratio and efficient thermal management capabilities. A PMMA chip was employed as the microarray device, where zip code sequences (24-mers), which were complementary to sequences present on the target, were microprinted into fluidic channels embossed into the PMMA substrate. Microfluidic addressing of the array reduced the hybridization time significantly through enhanced mass transport to the surface-tethered zip code probes. The two microchips were assembled as a single integrated unit with a novel interconnect concept to produce the flow-through microfluidic biochip. A microgasket, fabricated from an elastomer poly(dimethylsiloxane) with a total volume of the interconnecting assembly of <200 nL, was used as the interconnect between the two chips to produce the three-dimensional microfluidic network. We successfully demonstrated the ability to detect one mutant DNA in 100 normal sequences with the biochip assembly. The LDR/hybridization assay using the assembly performed the entire assay at a relatively fast processing speed: 6.5 min for on-chip LDR, 10 min for washing, and 2.6 min for fluorescence scanning (total processing time 19.1 min) and could screen multiple mutations simultaneously.

Base Sequence↗

Resist-free patterning of surface architectures in polymer-based microanalytical devices.

The ability to form patterns of chemically reactive surface functionalities in microanalytical devices using a simple photopatterning approach without the need for photoresist-based methods is described. Direct UV exposure of the surfaces of poly(methyl methacrylate), PMMA, and poly(carbonate), PC, microfluidic devices through optical masks leads to the production of patterns of near monolayer quantities of surface carboxylic acid groups as determined by surface coverage, X-ray photoelectron spectroscopy, and fluorescence microscopy experiments. Formation of the reactive carboxylic acid groups without significant physical (topographical) damage to the polymer device substrates is achieved by use of low UV fluence and exposure times. Modification of the patterned, surface carboxylic acid groups with metals, thermally responsive polymers, and antibodies results in microfluidic devices possessing metallic interconnects and detection electrodes and the ability to capture intact biological cells and proteins from solution.

Methylmethacrylates↗

Rapid PCR in a continuous flow device.

Continuous flow polymerase chain reaction (CFPCR) devices are compact reactors suitable for microfabrication and the rapid amplification of target DNAs. For a given reactor design, the amplification time can be reduced simply by increasing the flow velocity through the isothermal zones of the device; for flow velocities near the design value, the PCR cocktail reaches thermal equilibrium at each zone quickly, so that near ideal temperature profiles can be obtained. However, at high flow velocities there are penalties of an increased pressure drop and a reduced residence time in each temperature zone for the DNA/reagent mixture, that potentially affect amplification efficiency. This study was carried out to evaluate the thermal and biochemical effects of high flow velocities in a spiral, 20 cycle CFPCR device. Finite element analysis (FEA) was used to determine the steady-state temperature distribution along the micro-channel and the temperature of the DNA/reagent mixture in each temperature zone as a function of linear velocity. The critical transition was between the denaturation (95 degrees C) and renaturation (55 degrees C-68 degrees C) zones; above 6 mm s(-1) the fluid in a passively-cooled channel could not be reduced to the desired temperature and the duration of the temperature transition between zones increased with increased velocity. The amplification performance of the CFPCR as a function of linear velocity was assessed using 500 and 997 base pair (bp) fragments from lambda-DNA. Amplifications at velocities ranging from 1 mm s(-1) to 20 mm s(-1) were investigated. The 500 bp fragment could be observed in a total reaction time of 1.7 min (5.2 s cycle(-1)) and the 997 bp fragment could be detected in 3.2 min (9.7 s cycle(-1)). The longer amplification time required for detection of the 997 bp fragment was due to the device being operated at its enzyme kinetic limit (i.e., Taq polymerase deoxynucleotide incorporation rate).

Bacteriophage lambda↗

Engraftment of quiescent progenitors and conversion to full chimerism after nonmyelosuppressive conditioning and hematopoietic cell transplantation in miniature swine.

Our laboratory has previously reported a nonmyelosuppressive preparative regimen for hematopoietic cell transplantation that leads to mixed chimerism and allograft tolerance in miniature swine across minor and major histocompatibility disparities. Stable chimerism persisted in most of these animals but was restricted to T cells and confined to peripheral blood. Because of the importance of myeloid and erythroid progenitors for the treatment of hematologic disorders, the objective of this study was to assess whether such cells existed in the bone marrow of these lymphoid chimeras as an indication of functional engraftment. Colony-formation assays were performed on donor inocula before infusion and on bone marrow cells harvested from the transplant recipients. Donor-origin myeloid/erythroid progenitor colonies were detected in bone marrow from 6 of 7 lymphoid chimeric recipients. A delayed donor leukocyte infusion successfully converted a stable lymphoid chimera to full multilineage chimerism within 2 weeks. Donor-origin myeloid/erythroid progenitors could be detected in the bone marrow of a host-matched recipient after myeloablation and adoptive transfer of mobilized cells from one of the engrafted lymphoid chimeras. These data suggest that even when only lymphoid chimerism is readily detected by flow cytometry, dormant myeloid/erythroid progenitors can exist and subsequent conversion to full donor chimerism can be achieved. The ability to establish multilineage engraftment and chimerism without significant toxicity may have important clinical implications for the management of nonmalignant hematopoietic disorders and hematologic malignancies.

Animals↗