Rapid PCR in a continuous flow device.

Abstract

Continuous flow polymerase chain reaction (CFPCR) devices are compact reactors suitable for microfabrication and the rapid amplification of target DNAs. For a given reactor design, the amplification time can be reduced simply by increasing the flow velocity through the isothermal zones of the device; for flow velocities near the design value, the PCR cocktail reaches thermal equilibrium at each zone quickly, so that near ideal temperature profiles can be obtained. However, at high flow velocities there are penalties of an increased pressure drop and a reduced residence time in each temperature zone for the DNA/reagent mixture, that potentially affect amplification efficiency. This study was carried out to evaluate the thermal and biochemical effects of high flow velocities in a spiral, 20 cycle CFPCR device. Finite element analysis (FEA) was used to determine the steady-state temperature distribution along the micro-channel and the temperature of the DNA/reagent mixture in each temperature zone as a function of linear velocity. The critical transition was between the denaturation (95 degrees C) and renaturation (55 degrees C-68 degrees C) zones; above 6 mm s(-1) the fluid in a passively-cooled channel could not be reduced to the desired temperature and the duration of the temperature transition between zones increased with increased velocity. The amplification performance of the CFPCR as a function of linear velocity was assessed using 500 and 997 base pair (bp) fragments from lambda-DNA. Amplifications at velocities ranging from 1 mm s(-1) to 20 mm s(-1) were investigated. The 500 bp fragment could be observed in a total reaction time of 1.7 min (5.2 s cycle(-1)) and the 997 bp fragment could be detected in 3.2 min (9.7 s cycle(-1)). The longer amplification time required for detection of the 997 bp fragment was due to the device being operated at its enzyme kinetic limit (i.e., Taq polymerase deoxynucleotide incorporation rate).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Masahiko Hashimoto, Pin-Chuan Chen, Michael W Mitchell, Dimitris E Nikitopoulos, Steven A Soper, Michael C Murphy. 2004-10-19. Rapid PCR in a continuous flow device.. https://doi.org/10.1039/b406860b

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Propagation of fluorescent viruses in growing plaques.

To study virus propagation, we have developed a method by which the propagation of the Lambda bacteriophage can be observed and quantified. This is done by creating a fusion protein of the capsid protein gpD and the enhanced yellow fluorescent protein (EYFP). We show that this fusion allows capsid formation and that the modified viruses propagate on a surface covered with host bacteria thus forming fluorescent plaques. The intensity of fluorescence in a growing plaque determines the distribution of phages. This provides a new tool to study the propagation of infection at the microscopic level.

Bacteriophage lambda↗

Combining optical tweezers and scanning probe microscopy to study DNA-protein interactions.

We present the first results obtained with a new instrument designed and built to study DNA-protein interactions at the single molecule level. This microscope combines optical tweezers with scanning probe microscopy and allows us to locate DNA-binding proteins on a single suspended DNA molecule. A single DNA molecule is stretched taut using the optical tweezers, while a probe is scanned along the molecule. Interaction forces between the probe and the sample are measured with the optical tweezers. The instrument thus enables us to correlate mechanical and functional properties of bound proteins with the tension within the DNA molecule. The typical friction force between a micropipette used as probe and a naked DNA molecule was found to be <1 pN. A 16 micro m DNA molecule with approximately 10-15 digoxygenin (DIG) molecules located over a 90 nm range in the middle of the DNA was used as a model system. By scanning with an antidigoxygenin (alpha-DIG) antibody-coated pipette we were able to localize these sites by exploiting the high binding affinity between this antibody-antigen pair. The estimated experimental resolution assuming an infinitesimally thin and rigid probe and a single alpha-DIG/DIG bond was 15 nm.

Bacteriophage lambda↗

A rapid DNA digestion system.

This paper presents a novel microfluidic DNA digestion system incorporating a high performance micro-mixer. Through the appropriate control of fixed and periodic switching DC electric fields, electrokinetic forces are established to mix the DNA and restriction enzyme samples and to drive them through the reaction column of the device. The experimental and numerical results show that a mixing performance of 98% can be achieved within a mixing channel of length 1.6 mm when a 150 V/cm driving voltage and a 5 Hz switching frequency are applied. The relationship between the mixing performance, switching frequency, and main applied electric field is derived. It is found that the optimal switching frequency depends upon the magnitude of the main applied electric field. The successful digestion of lambda-DNA using Eco RI restriction enzyme is demonstrated. The DNA-enzyme reaction is completed within 15 min in the proposed microfluidic system, compared to 50 min in a conventional large-scale system. Hence, the current device provides a valuable tool for rapid lambda-DNA digestion, while its mixer system delivers a simple yet effective solution for mixing problems in the micro-total-analysis-systems field.

Bacteriophage lambda↗