Dual-chamber versus single-chamber detection enhancements for implantable defibrillator rhythm diagnosis: the detect supraventricular tachycardia study.

BACKGROUND: Delivery of inappropriate shocks caused by misdetection of supraventricular tachycardia (SVT) remains a substantial complication of implanted cardioverter/defibrillator (ICD) therapy. Whether use of optimally programmed dual-chamber ICDs lowers this risk compared with that in single-chamber ICDs is not clear. METHODS AND RESULTS: Subjects with a clinical indication for ICD (n=400) at 27 participating centers received dual-chamber ICDs and were randomly assigned to strictly defined optimal single- or dual-chamber detection in a single-blind manner. Programming minimized ventricular pacing. The primary end point was the proportion of SVT episodes inappropriately detected from the time of programming until crossover or end of study. On a per-episode basis, 42% of the episodes in the single-chamber arm and 69% of the episodes in the dual-chamber arm were due to SVT. Mortality (3.5% in both groups) and early study withdrawal (14% single-chamber, 11% dual-chamber) were similar in both groups. The rate of inappropriate detection of SVT was 39.5% in the single-chamber detection arm compared with 30.9% in the dual-chamber arm. The odds of inappropriate detection were decreased by almost half with the use of the dual-chamber detection enhancements (odds ratio, 0.53; 95% confidence interval, 0.30 to 0.94; P=0.03). CONCLUSIONS: Dual-chamber ICDs, programmed to optimize detection enhancements and to minimize ventricular pacing, significantly decrease inappropriate detection.

Aged↗

Mechanism of diastolic mitral regurgitation in candidates for cardiac resynchronization therapy.

It was hypothesized that restricted diastolic leaflet motion is implicated not only in the mechanism of systolic mitral regurgitation (MR) but also in the mechanism of diastolic MR observed in patients with severe heart failure. Cardiac resynchronization therapy (CRT) can oppose increased mitral leaflet tethering by increasing transmitral pressure, thereby providing an opportunity to explore this hypothesis. A total of 26 consecutive candidates for CRT with diastolic MR were compared with 26 candidates without diastolic MR. Maximal diastolic mitral leaflet opening and inflow direction and measures of mitral valve apparatus (i.e., mitral annular diameters, calculated mitral annular area, and tethering distance) were assessed from the apical 4-chamber view before and during CRT. There were no significant differences in New York Heart Association functional class, ejection fraction, QRS duration, PR interval, systolic MR grade, or 2-dimensional geometry of the mitral valve apparatus between the groups. Patients with diastolic MR had more restricted maximal diastolic leaflet openings (54 degrees +/- 17 degrees vs 71 degrees +/- 11 degrees , p = 0.003) and substantially smaller inflow angles (66 degrees +/- 7 degrees vs 79 degrees +/- 9 degrees , p = 0.0003) compared with patients without diastolic MR. After the institution of CRT, diastolic MR was eliminated in all patients, although there were no significant changes in any of the parameters of mitral valve apparatus. In conclusion, abnormal mitral valve tethering is a constitutive element of the mechanism of diastolic MR in patients with left ventricular dysfunction. Its acute resolution after CRT does not seem to be caused by changes in mitral valve geometry but rather by an increase in transmitral closing forces.

Cardiac Pacing, Artificial↗

Clinical surveillance of a tined, bipolar, silicone-insulated ventricular pacing lead.

AIMS: This study assesses short- and long-term performance of the S80TB ventricular lead manufactured by Sorin Biomedica, Italy. METHODS AND RESULTS: Three hundred and thirty leads were implanted and had complete follow-up with us for a minimum of 60 months or up to failure, removal, and/or patient death (mean 40 months, range: 1 day to 81 months). Thirty-two patients (9.6%) had spontaneous lead-related complications: 7 (2.1%) occurred during the first week; 25 (7.6%) had chronic complications, of which 20 (6.1%) necessitated re-operations; 3 (0.9%) were lead material failures. Of the 110 re-operations (90 pacemaker replacements and 20 operations due to complications), 7 additional cases (6.4%) were complicated by unique connector damage that occurred during disconnection of the lead from the connector block. The Kaplan-Meier estimated 5-year lead survival free of lead material failure and free of any significant lead complication were 97.9 and 87%, respectively. CONCLUSION: The S80TB lead demonstrates an acceptable rate of acute and chronic spontaneous complications and very few lead material failures over 5 years of follow-up. However, there seems to be a relatively high incidence of connector damage during disconnection from the connector block. Extra caution is required during those procedures in patients with this lead.

Adult↗

Improvement of congestive heart failure by upgrading of conventional to resynchronization pacemakers.

AIMS: To compare the clinical response of patients with right ventricular apical pacing (RVAP) upgraded to cardiac resynchronization therapy (CRT) to that of previously nonpaced heart failure (HF) patients who had de novo CRT implantation. BACKGROUND: The role of CRT in patients with wide QRS and HF due to RVAP is less well established than in other CRT candidates. METHODS: Ninety-eight consecutive patients with CRT were studied (mean age 70, mean ejection fraction 0.23). Group A: patients having RVAP prior to CRT implantation (n = 25), group B: patients without prior RVAP (n = 73). Clinical and echocardiographic parameters were recorded prior to, and 3 months after, CRT implantation. RESULTS: Group A patients had a wider QRS at baseline compared to group B (203 +/- 32 ms vs 163 +/- 30 ms respectively, P < 0.001), and a shorter 6-minute walking distance (222 +/- 118 m vs 362 +/- 119 m, respectively, P < 0.005). Otherwise, clinical and echocardiographic parameters were not different. At follow up, group A patients had an average 0.7 +/- 0.5 decrease in their NYHA functional class, compared to 0.3 +/- 0.7 in group B patients (P < 0.05). Six-minute walking distance increased by 93 +/- 113 m in group A, versus 36 +/- 120 m in group B (P = 0.22). There was no difference in echocardiographic response to CRT between the groups. CONCLUSIONS: HF patients with prior RVAP demonstrate clinical improvement after upgrading to CRT that is comparable, and in some aspects, even better than that observed in HF patients with native conduction delay who undergo de novo CRT implantation.

Aged↗

[Cardiac MRI: report on preliminary experience in Sheba Medical Center and review of main indications].

The rapid technical development of cardiac MR imaging in the last decade enables us today to evaluate cardiac morphology, function and viability in a reliable and very good spatial and temporal resolution. The advanced technology allows us to conduct those examinations in an acceptable time for clinical daily use and thus, the number of indications for cardiac MR imaging is steadily increasing. Since the beginning of 2004, a dedicated cardiac MR scanner has been employed in the Department of Medical Imaging in the Sheba Medical Center. We hereby conclude our preliminary experience with 58 sequential cases that were referred for cardiac MR imaging. Indications for the examination included 17 patients with congenital cardiac and great vessels anomalies, 14 patients with a suspected cardiac mass, 12 patients with suspected right ventricular dysplasia, and 4 patients with suspected constrictive pericarditis. This article also includes a review of the main indications for obtaining cardiac MR imaging.

Heart↗

Mid-term results of the 'hybrid maze': a combination of bipolar radiofrequency and cryoablation for surgical treatment of atrial fibrillation.

BACKGROUND AND AIM OF THE STUDY: Although the use of new sources of energy for the ablation of atrial fibrillation (AF) has simplified the procedure, concerns have been expressed with regard to the safety and efficacy of the various devices. Herein are described the results of a technique using a combination of bipolar radiofrequency (RF) and cryoablation. METHODS: Between February 2004 and August 2005, the combined procedure was used on 60 patients, 32 of whom (54%) had persistent AF, and 28 (46%) permanent AF. Lesions set similar to the Maze III procedure were used, with the addition of a right atrial isthmus lesion in the area of the coronary sinus and without right atrial appendage amputation and septal lesion. RESULTS: There were no operative complications and no death or major morbidity. The mean duration of the ablation procedure was 30 min (range: 27-36 min) for biatrial procedures, and 16 min (range: 15-19 min) for left atrial procedures. Forty-two patients (70%) were discharged in sinus rhythm. On completion of follow up, 48 patients (80%) were in sinus rhythm. Among 45 patients treated with cryoablation rather than monopolar RF, 89% were in sinus rhythm at the mean follow up of nine months. The predictor for recurrent post-procedural AF was preoperative permanent AF for more than 10 years' duration (p = 0.039), while that for postoperative atypical flutter was use of the monopolar RF ablator rather than the cryoablator (p = 0.001). CONCLUSION: The use of a bipolar RF device with the cryoprobe is an appealing combination which enables the Maze III lesion set to be completed in a straightforward, safe, and efficient manner.

Adult↗

Plowing the atrium and growing thrombi: two cases of large atrial thrombi following ablative and surgical procedure for atrial fibrillation.

AIM: We present two patients with a large left atrial (LA) thrombus following invasive treatment for atrial fibrillation and inadequate anticoagulation. METHODS AND RESULTS: Case 1: A 30-year-old woman, with a one-year history of symptomatic paroxysmal atrial fibrillation resistant to medical therapy, underwent catheter ablation for atrial fibrillation. Three days after the procedure the patient presented with dizziness, fatigue, rapid atrial fibrillation with a sub-therapeutic INR. Transesophageal echocardiography (TEE) revealed a large LA thrombus. Case 2: A 59-year-old male, with severe mitral regurgitation and chronic atrial fibrillation, underwent mitral valve repair and Cox-Maze procedure. Three months later, while asymptomatic, a follow-up transthoracic echocardiography a large posterior LA thrombus was imaged. His INR was also sub-therapeutic. Both patients were treated by enhancing anticoagulation and close echocardiographic follow-up. So far both patients have remained asymptomatic two months following discharge. CONCLUSION: Large LA thrombi detected by transthoracic echocardiography are a rare complication of the Cox-Maze procedure and radio-frequency ablation for atrial fibrillation, which may occur even in patients with restored normal sinus rhythm receiving inadequate anticoagulation therapy.

Adult↗

Atrial fibrillation in dobutamine stress echocardiography.

OBJECTIVES: To describe the incidence of atrial fibrillation induced by dobutamine stress echocardiography and characterize patients at risk of developing atrial fibrillation, by constructing a simple validated risk score index. DESIGN: An observational study using prospectively collected data. METHODS: 3800 consecutive patients in sinus rhythm undergoing dobutamine stress echocardiography were randomly divided to a case (2/3) and test group (1/3). Associations of predetermined demographic, clinical, electrocardiographic and echocardiographic variables were calculated in patients with and without atrial fibrillation induced by dobutamine stress echocardiography in the case group. Logistic regression analysis determined significant independent risk predictors, a scoring index was constructed and validated on the test group. RESULTS: There was a 2% incidence of dobutamine stress echocardiography-induced atrial fibrillation in the study population. Risk predictors of atrial fibrillation included: a history of atrial fibrillation (2 points), increased left atrial diameter, right bundle branch block, decreased rest heart rate and hypertension (1 point each). The case subgroup low-risk patients (score 0-2) had a 1% risk, moderate-risk patients (score 3) a 2.7% and high-risk patients (score 4-6) a 14.5% risk of developing atrial fibrillation during dobutamine stress echocardiography. The rates in the test subgroup were 1%, 3.8% and 15.3%, respectively. CONCLUSION: Atrial fibrillation during dobutamine stress echocardiography is not common, the risk of developing atrial fibrillation during dobutamine stress echocardiography can be predicted by using a simple risk score system comprised of clinical, electrocardiographic and rest echocardiographic variables, which may be of help when planning a dobutamine stress echocardiography test in selected cases.

Aged↗

Optimal combination of discriminators for differentiating ventricular from supraventricular tachycardia by dual-chamber defibrillators.

UNLABELLED: Discriminators for ventricular/supraventricular tachycardia. INTRODUCTION: Dual-chamber implantable cardioverter defibrillators (ICDs) use discriminators to differentiate between supraventricular tachycardias (SVTs) and ventricular tachycardias (VT), the accuracy of which may depend on the type and method used. ICDs can combine rate branching of tachyarrhythmias according to their A:V relationship with two SVT-VT discriminators in each rate branch, using ANY (either) or ALL (both) logic. Our goal was to determine the optimal discriminator combination. METHODS: Stored electrogram data from 596 spontaneous tachyarrhythmias from 203 patients with Photon DR ICDs were analyzed. Arrhythmias are first classified by the relationship of atrial and ventricular rates (rate branches V A) followed by additional discriminators: morphology and/or sudden onset if V=A; morphology and/or interval stability if V V branch: ANY logic provided adequate sensitivity. The combination of morphology only in V=A with interval stability or morphology (ANY logic) in V<A, provided the optimal result with sensitivity, specificity, positive, and negative predictive values of 99%, 79%, 87%, and 98%, respectively. CONCLUSION: SVT-VT combined discriminators strongly influence dual-chamber SVT-VT discrimination performance. In our study, optimal programming is morphology only in the V=A branch and morphology or interval stability (ANY) in the V<A branch. ALL logic should be used with caution due to loss of sensitivity.

Adult↗

Long-term performance of screw-in atrial pacing leads: a randomized comparison of J-shaped and straight leads.

OBJECTIVE: In this prospective, randomized, control study we compared performance of J-shaped (JL) and straight atrial leads (SL) with active (screw-in) fixation mechanism, over a 5-year follow-up period. SUBJECTS AND METHODS: A total of 208 consecutive patients were randomized for implantation with a Medtronic 4568 JL model (n = 103) versus a Medtronic 4068 SL model (n = 105), and all lead-related measurements and complications were recorded. RESULTS: Lead-related complications occurred in JL and SL with similar frequency (6% and 9%, respectively, P = 0.45). Lead dislodgment occurred in 8 (7.8%) cases in SL versus none in JL (P = 0.004). Lead malfunction and excessive pacing thresholds without macrodislodgment occurred more frequently in JL (11; 10.7%) than in SL (4; 3.8%), P = 0.055. Lead material failure (insulation break) occurred only once in SL at the 5-year checkup. Most complications occurred during the first year after implantation. Other events occurred in both leads with similar frequency and included: death in 39 and 35, loss of follow-up in 8 and 6, and development of atrial fibrillation in 9 and 15 patients, respectively. Of those who completed follow-up, lead impedance and pacing threshold increased significantly in both groups. P wave decreased in SL but not in JL. CONCLUSION: More dislocations occurred in SL, but were counterbalanced by more lead malfunctions and excessive pacing thresholds in the JL group. Both leads demonstrated minor deterioration in electrical measurements during follow-up, with only 1 case of lead material failure in SL. Overall, both groups demonstrated favorable lead performance throughout follow-up.

Aged↗

Programmable multiple pacing configurations help to overcome high left ventricular pacing thresholds and avoid phrenic nerve stimulation.

BACKGROUND: High left ventricular pacing (LVP) thresholds and phrenic nerve stimulation (PNS) are common problems with cardiac resynchronization (CRT). Newer systems capable of multiple LVP configurations may help overcome these problems without the need for reoperation. METHODS: CRT systems capable of multiple LVP configurations (Guidant models H155 and H145) were implanted in 43 patients (study group). An additional 49 patients (control group) received CRT systems (Guidant, Medtronic, Biotronik, St. Jude Medical, various models) lacking this feature. RESULTS: Overall, acute high (> or =2.5 V/0.5 ms) LVP thresholds were encountered in 13 (30%) of the study group, and 25 (50%) of control group patients (P = 0.03). PNS was encountered in 5 (12%) of the study group and 12 (24%) of control group patients (P = 0.13). All cases of high LVP thresholds and PNS in the study group were managed by switching to a different LVP configuration, while high thresholds remained in control group patients, and PNS was managed by replacing the lead. The CS lead was successfully placed in a lateral branch in 95% of study group, compared to only 77% of control group patients (P = 0.004). CONCLUSIONS: Multiple LVP configurations were clinically useful in a significant number of patients undergoing CRT system implantation by helping to overcome high LVP thresholds and PNS, and by providing more flexibility in placing the LV lead.

Aged↗

Use of advanced mapping systems to guide ablation in complex cases: experience with noncontact mapping and electroanatomic mapping systems.

OBJECTIVE: This report describes our experience with noncontact mapping and electroanatomic mapping in complex ablations, which are defined as ablations done after failure of conventional ablation. MATERIAL AND METHODS: Patients were included (N = 68; 49% with structural heart disease) in whom previous ablation failed and in whom a second procedure was done with advanced mapping. Non-contact mapping was used in 17 patients, electroanatomic mapping in 36, and both noncontact and electroanatomic mapping in 15. Arrhythmias included focal atrial tachycardia (n = 16), reentrant atrial tachycardia (n = 14), right ventricular outflow tachycardia (n = 10), post-myocardial infarction ventricular tachycardia (n = 9), and others (n = 19). RESULTS: Acute success at the second ablation was achieved in 79% of patients. At 20 +/- 9 months after the procedure, 69% of these patients reported having significantly fewer symptoms than before the second ablation, and 51% were free of symptoms. Only 16% were using antiarrhythmic medications. Complications included a small pericardial effusion in two patients, hypotension in one patient, and a femoral pseudoaneurysm in another. CONCLUSIONS: Advanced mapping is a useful and safe adjunct for catheter ablation after ablation has failed in patients with complex substrate.

Arrhythmias, Cardiac↗

Adaptive cardiac resynchronization therapy device: a simulation report.

We report the results of a simulation of an adaptive cardiac resynchronization therapy (CRT) device performing biventricular pacing in which the atrioventricular (AV) delay and interventricular (VV) interval parameters are changed dynamically in response to data provided by the simulated IEGMs and simulated hemodynamic sensors. A learning module, an artificial neural network, performs the adaptive part of the algorithm supervised by an algorithmic deterministic module, internally or externally from the implanted CRT or CRT-D. The simulated cardiac output obtained with the adaptive CRT device is considerably higher (30%) especially with higher heart rates than in the nonadaptive CRT mode and is likely to be translated into improvement in quality of life of patients with congestive heart failure.

Arrhythmias, Cardiac↗

Upper limit of vulnerability determination during implantable cardioverter-defibrillator placement to minimize ventricular fibrillation inductions.

The defibrillation threshold (DFT) and upper limit of vulnerability (ULV) were determined using step-down protocols in 50 patients who underwent implantable cardioverter-defibrillator placement or testing. The sensitivity and specificity of each ULV energy level was assessed for detecting an increased DFT, correlation of the DFT and ULV, and optimal shock timing for ULV determination. A ULV <10 or 11 J (failure to induce ventricular fibrillation with 10- to 11-J shocks) was 100% predictive of an acceptable DFT and may be sufficient to exclude unacceptable DFTs in 60% of implantable cardioverter-defibrillator recipients. All 4 shocks used to scan the peak of the T wave during ULV testing were necessary for accurate ULV determination.

Aged↗

A novel form of familial bidirectional ventricular tachycardia.

We evaluated a family with 30 members, 3 of whom had incessant polymorphous and bidirectional ventricular tachycardia (VT) that was electrocardiographically similar to that described in other familial polymorphic VT series; the VT was unrelated to exercise and asymptomatic. More subtle, but morphologically similar, ventricular arrhythmias were detected in 3 other family members. Genes related to intracellular calcium transport were specifically excluded.

Adult↗