Long-term prognosis of inducible ventricular flutter: not an innocent finding.

BACKGROUND: The prognostic significance of ventricular flutter (VFL) induced during programmed electrical stimulation (PES) is currently unknown. METHODS: This study examined patients who had PES-induced VFL and assessed their long-term prognosis compared with patients who had inducible sustained monomorphic ventricular tachycardia (SMVT). RESULTS: Of 3414 patients undergoing PES, 74 (2%) had sustained VFL. They were compared with a group of 71 patients undergoing PES in the same time frame who had inducible SMVT. Patients with inducible VFL had a higher ejection fraction than patients with SMVT (0.39 vs 0.33; P =.05). More aggressive pacing was required for arrhythmia induction in patients with VFL, with more stimuli (2.7 +/- 0.5 vs 2.2 +/- 0.6; P <.01) and tighter S(2), S(3), and S(4) intervals. After a mean follow-up of 30 +/- 31 months, the mortality rate was 34% in patients with VFL and 30% in patients with SMVT (P =.41). No difference in the 2 groups in overall survival or a combined end point of sudden death or appropriate implantable cardioverter defibrillator shock was revealed with Kaplan-Meier analysis. CONCLUSION: The long-term prognosis of patients with inducible VFL is similar to that of patients with inducible SMVT, even when VFL is induced with a relatively aggressive protocol.

Arrhythmias, Cardiac↗

Is idiopathic ventricular fibrillation a short QT syndrome? Comparison of QT intervals of patients with idiopathic ventricular fibrillation and healthy controls.

OBJECTIVE: The purpose of this study was to determine if patients with idiopathic ventricular fibrillation (VF) have shorter QT intervals than comparable healthy controls. BACKGROUND: The upper limit of the normal QT is well defined. Less is known about the lower limit of the normal QT. Patients with the recently described "short QT syndrome" have characteristics resembling those of patients with idiopathic VF. METHODS: The ECGs of 28 consecutive patients with idiopathic VF (17 men and 11 women, age 31 +/- 17 years) were compared to those of 270 age- and gender- matched healthy controls. Based on published literature, we defined "short QT" as QTc < or = 360 ms for males and < or = 370 ms for females. RESULTS: Despite significant overlapping, the QTc of males with idiopathic VF was shorter than the QTc of healthy males (371 +/- 22 ms vs 385 +/- 19 ms, P = .034). Short QT intervals were found more frequently among males with idiopathic VF (35% vs 10%, P = .003). No such differences were apparent among women. Short QTc intervals were more commonly seen during bradycardia. However, the correlation between short QT and a history of VF was independent of heart rate. CONCLUSIONS: "Short" QTc values are commonly seen in male patients with idiopathic VF. However, "short" QTc values are not rare among healthy adults, especially at slow heart rates. Further studies are needed to define when a given QT is really "too short."

Adult↗

Long-term outcome of patients who received implantable cardioverter defibrillators for stable ventricular tachycardia.

INTRODUCTION: Evidence is inconclusive concerning the role of implantable cardioverter defibrillators (ICDs) to treat patients with hemodynamically stable ventricular tachycardia (VT). The goal of this study was to estimate future risk of unstable ventricular arrhythmias in patients who received ICDs for stable VT. METHODS AND RESULTS: We reviewed complete ICD follow-up data from 82 patients (age 66.1 +/- 11.3 years; left ventricular ejection fraction 32.3%+/- 11.2%; mean +/- SD) who received ICDs for stable VT. During the follow-up period of 23.6 +/- 21.5 months (mean +/- SD), 15 patients (18%) died, and 10 (12%) developed unstable ventricular arrhythmia, 8 of whom had the unstable arrhythmia as the first arrhythmia after ICD placement. Estimated 2- and 4-year survival in the whole group was 80% and 74%, respectively. Estimated 2- and 4-year probability of any VT and unstable VT was 67% and 77% and 11% and 25%, respectively. There were no differences in age, ejection fraction, sex, underlying heart disease, cycle length, symptoms, baseline electrophysiologic study results, or QRS characteristics of qualifying VT between patients who developed unstable ventricular arrhythmia and patients who did not. Twenty-nine patients (35%) had at least one inappropriate shock, and 11 (13%) underwent further surgery for ICD-related complications. CONCLUSION: Patients who present with hemodynamically stable VT are at risk for subsequent unstable VT. ICD treatment offers potential salvage of patients with stable VT who subsequently develop unstable VT/ventricular fibrillation, although complications and inappropriate shocks are considerable. No predictors could be found for high and low risk for unstable arrhythmias. These findings support ICD treatment for stable VT survivors.

Aged↗

Use of automatic threshold tracking function with non-low polarization leads: risk for algorithm malfunction.

The AutoCapture (AC) function of new pacemakers (PM) from St Jude Medical (SJM) was originally recommended for use with low polarization (LP) ventricular leads only.However, recent reports have encouraged the use of the AC function with various leads, including those lacking a special LP design. The objective of this study was to analyze the reliability and safety of the AC algorithm application with different types of pacing leads. The study group comprised 30 consecutive patients with AC PMs connected to three different types of non-LP leads. Ten patients with SJM LP leads served as the control group. The study protocol included a complete AC function test using four different pulse widths (PW). The pacing threshold was independently assessed by a manual/semiautomatic check. Erratic behavior of polarization measurements with increasing PWs was demonstrated in 43% (n = 13) of the study group. Invalid polarization measurements resulted in erroneous algorithm recommendation to apply AC function in 17% (n = 5) of the study patients. Subsequent AC function activation lead to incorrect threshold determination due to missed noncapture in three patients. AC function should be applied with caution with non-LP leads. "Off label" use of these leads may cause erroneous polarization signal measurements which, in some cases, may result in incorrect pacing threshold determination, rendering a potential risk to dependent patients.

Algorithms↗

Clinical characteristics of unexpected death among young enlisted military personnel: results of a three-decade retrospective surveillance.

STUDY OBJECTIVE: To explore the causes of sudden and unexpected death in a young and healthy military population, to examine the various patterns of diseases associated with these tragic events, and to investigate the factors found to be associated with this grave outcome. DESIGN: We retrospectively investigated 151 cases of Israeli military personnel who died unexpectedly over a 30-year period. We collected all the available medical records, autopsy results, and investigation committee reports. RESULTS: A total of 151 cases of sudden and unexpected death occurred among enlisted military personnel during the period. Cardiac disorders caused 47% of deaths, followed by neurologic causes (17%) and pulmonary causes (11%). In 30 events (20%), the cause of death remained undetermined. Symptoms (eg, syncope, chest pain, palpitations, and others) occurred prior to death in 52 cases (34%). Asthma was the most common risk factor in our study population having been previously recognized in 10 cases (6.7%). Eight of the 13 subjects with asthma died following an acute asthmatic attack. CONCLUSION: Cardiac events are the leading cause of unexpected death in young healthy people. The frequency of subjects with asthma was found to be higher than that in the general age-adjusted population.

Adolescent↗

Pericarditis following permanent pacemaker insertion.

BACKGROUND: The appearance of pericarditis following insertion of a permanent pacemaker is not widely acknowledged in the literature. OBJECTIVES: To describe our experience with pericarditis following 395 permanent pacemaker implantations over 2 years. METHODS: We retrospectively reviewed the medical records of 395 consecutive patients in whom new pacing systems or pacemaker leads had been implanted over a 2 year period. We searched the records for pericarditis that developed within 1 month after pacemaker implantation according to the ICD-9 code. The incidence, clinical picture, response to treatment, and relationship to lead design and location were studied. RESULTS: Eight cases (2%) of pericarditis following implantation were detected. Clinical manifestations in all patients were similar to those of post-pericardiotomy syndrome and included chest pain (n = 7), friction rub (n = 1), fever (n = 2), fatigue (n = 2), pleural effusion (n = 2), new atrial fibrillation (n = 2), elevated erythrocyte sedimentation rate (n = 4), and echcardiographic evidence of pericardial effusion (n = 8). All affected patients had undergone active fixation (screw-in) lead implantation in the atrial position. The incidence of pericarditis with screw-in atrial leads was 3% compared to 0% in other cases (P < 0.05). CONCLUSIONS: Pericarditis is not uncommon following pacemaker implantation with active fixation atrial leads. Special attention should be paid to identifying pericardial complications following pacemaker implantation, especially when anticoagulant therapy is resumed or initiated. The use of passive fixation leads is likely to reduce the incidence of pericarditis but this issue should be further investigated.

Adrenal Cortex Hormones↗

Incidence of dual AV node physiology following termination of AV nodal reentrant tachycardia by adenosine-5'-triphosphate: a comparison with drug administration in sinus rhythm.

Administration of adenosine triphosphate (ATP) in sinus rhythm identifies dual atrioventricular node physiology (DAVNP) in 75% of patients with inducible slow/fast AV nodal reentrant tachycardia (AVNRT). The incidence of DAVNP following termination of AVNRT with ATP is unknown. Incremental doses of ATP (10-60 mg) were administered, first in sinus rhythm and then during tachycardia induced at electrophysiologic study, to 84 patients with inducible AVNRT and to 18 control patients with inducible AV reentrant tachycardia (AVRT) and no electrophysiologic evidence of DAVNP. Study end-points were the occurrence of DAVNP or > or = 2nd degree AV block following administration of ATP in sinus rhythm and tachycardia termination following administration of ATP during tachycardia. Of the 82 patients with AVNRT who completed the study, 62 (75.6%) exhibited DAVNP following administration of 17.1 +/- 9.4 mg ATP in sinus rhythm, while 30 (36.5%) exhibited DAVNP at the termination of AVNRT following administration of 10.6 +/- 2.4 mg ATP. The occurrence of DAVNP following the administration of 10 mg ATP in sinus rhythm.was a good predictor (62%) of its occurrence after termination of AVNRT with ATP. The dose of ATP had a strong correlation between the presence of DAVNP following AVNRT termination and the ATP doses needed for tachycardia termination. Of the 18 control patients, none had DAVNP at ATP test during sinus rhythm but 1 (5.5%) showed slight (60 msec) PR jump after termination of AVRT with ATP. In conclusion, DAVNP is present in a relatively high proportion (36.5%) of patients following termination of AVNRT with ATP but is much less frequent (5.5%) in control patients. Thus, findings at termination of tachycardia by ATP may be useful in the noninvasive diagnosis of the mechanism of a paroxysmal supraventricular tachycardia.

Journal Article↗

Discrepancies between the upper limit of vulnerability and defibrillation threshold: prevalence and clinical predictors.

INTRODUCTION: Upper limit of vulnerability (ULV) has a strong correlation with defibrillation threshold (DFT) in patients with implantable cardioverter defibrillators (ICDs). Significant discrepancies between ULV and DFT are infrequent. The aim of this study was to characterize patients with such discrepancies. METHODS AND RESULTS: The ULV and DFT were determined in 167 ICD patients. Univariate and multivariate analyses were used to evaluate clinical predictors of a significant difference (> or =10 J) between ULV and DFT. Only 8 patients (5%) had > or =10 J difference. ULV exceeded DFT in all of them. Absence of coronary artery disease (6/8 vs 48/159 patients; P = 0.05) and absence of documented ventricular arrhythmias (4/8 vs 12/159 patients; P = 0.01) were the only independent predictors of a significant ULV-DFT discrepancy. CONCLUSION: Significant discrepancies between ULV and DFT occur in 5% of patients with ICDs. Absence of coronary disease and documented ventricular arrhythmias predict such a discrepancy. At ICD implant, DFT testing is recommended in these patients and in patients with a high (>20 J) ULV before first-shock energy and the need for lead repositioning are determined.

Aged↗

Managing pacemaker safety alerts: experience with three successive models of a single manufacturer.

This report describes the experience of a large pacemaker center during three successive replacement operations due to safety alerts involving three models from the same manufacturer. Between March 1993 and May 1999, 210 patients were implanted with three DDD pacemaker models (Sorin Biomedica, Saluggia, Italy) that were subsequently subject to safety alerts. Pacemaker records were reviewed for complications related to device malfunction, and those secondary to the replacement procedure. Pacemaker malfunction was observed in 16.4% of units despite much lower estimates from the company (range 1-4%). With the exception of one, all units were replaced. Malfunctions were discovered in 7 of 20 pacemakers following an urgent call for follow-up issued as a result of the alert. Twenty units implanted as substitutes for those replaced following the first alert turned out to be subject to the third alert. Significant clinical consequences of malfunction occurred in 5.3% of patients including a near fatal event in one case, while complications related to the replacement procedure occurred in 8.3% of patients, including one fatality. On the issuance of a safety alert, failure rates in a particular center may be higher than published by the manufacturer, and should prompt action by the center to weigh local incidence of device failure against complications of replacement procedures. When device failure mechanism is not entirely clear, particularly in cases of successive model failures, replacement devices from a different manufacturer should be considered.

Adolescent↗

Cardiac resynchronization therapy: a new frontier in the management of heart failure.

CRT offers today another option for some patients with heart failure, side by side with more "traditional" therapies like drugs, assist devices, and heart transplantation. Clinical studies show that in properly selected patients a significant improvement in hemodynamic parameters and clinical status can be achieved by BV pacing. It is still unknown whether this type of therapy will also result in a survival benefit for patients with severe heart failure. The next few years certainly promise to be as exciting for CRT as were the last few.

Cardiac Pacing, Artificial↗

Noncontact mapping to guide ablation of right ventricular outflow tract tachycardia.

OBJECTIVES: [corrected] The aim of this study was to determine whether noncontact mapping is feasible in the right ventricle and assess its utility in guiding ablation of difficult-to-treat right ventricular outflow tract (RVOT) ventricular tachycardia (VT). BACKGROUND: In patients without inducible arrhythmia, RVOT VT may be difficult to ablate. Noncontact mapping permits ablation guided by a single tachycardia complex, which may facilitate ablation of difficult cases. However, the mapping system may be geometry-dependent, and it has not been validated in the unique geometry of the RVOT. METHODS: Ten patients with left bundle inferior axis VT, no history of myocardial infarction and normal left ventricular function underwent noncontact guided ablation; seven had failed previous ablation and three had received a defibrillator. All noncontact maps were analyzed by a blinded reviewer to determine whether the arrhythmia focus was epicardial and to predict on the basis of the map whether arrhythmia would recur. RESULTS: The procedure was acutely successful in 9 of 10 patients. During a mean follow-up of 11 months, 7 of 9 patients remained arrhythmia-free. Both patients in whom the blinded reviewer predicted failure had arrhythmia recurrence: one due to epicardial origin with multiple endocardial exit sites and one due to discordance between site of lesion placement and earliest activation on noncontact map. CONCLUSIONS: Mechanisms of ablation failure in RVOT VT include absence of sustained arrhythmia, difficulty with substrate localization and epicardial origin of arrhythmia. In this study, noncontact mapping was safely and effectively used to guide ablation of patients with difficult-to-treat RVOT VT.

Adult↗

Inhibition of biventricular pacemakers by oversensing of far-field atrial depolarization.

This report describes two patients who exhibited far-field oversensing of the P wave by the ventricular channel of a DDD biventricular pacemaker implanted for the treatment of congestive heart failure. Oversensing probably occurred secondary to slight displacement of the left ventricular lead in the coronary venous system. Long-term reliable pacing was restored by decreasing the sensitivity of the ventricular channel.

Aged↗

ST-segment deviation following implantable cardioverter defibrillator shocks: incidence, timing, and clinical significance.

ST-segment analysis is frequently used during surgical procedures, while ST deviation is considered a sign of myocardial injury. ST deviations were reported following transthoracic and epicardial electrical shocks. The prevalence, timing, and clinical significance of ST-segment deviation following endocardial ICD shocks are discussed in this article. Twenty-eight patients undergoing 125 shock episodes during ICD implantation or testing were included. A 12-lead ECG was recorded at baseline, continuously during the first 3-10 seconds, 1 minute after test shocks, 3-10 seconds and 1 and 5 minutes after each shock given to terminate VF. ST deviation was diagnosed when the ST-segment was displaced > or = 1 mm in at least one lead compared to baseline. ST-segment deviations were observed after 49 (39%) of all shock episodes in 17 (61%) of patients. ST elevation was observed after 30 (24%) of all shock episodes, and ST depression after 31 (25%). Following 13 shock episodes in seven patients, ST-elevation and depression were observed. ST depressions occurred more frequently after shocks given to terminate VF than after lower energy test shocks (28% vs 18% respectively, P = 0.045). However, there was no significant difference in the prevalence of ST elevations between the lower or higher energy shocks. No adverse clinical events were observed in patients with or without postshock ST-segment deviation. ST-segment deviation following endocardial ICD shocks is a frequent phenomenon, occurring acutely and resolving during the first few minutes postshock. It mayhave no prognostic implications.

Defibrillators, Implantable↗

Multiple pulse generator malfunctions with a dual chamber pacemaker.

The aim of this study was to evaluate the dual chamber uni/bipolarpacemaker Minidual 50, manufactured by Sorin Biomedica. Between 1995 and 1998, 66 Minidual 50 models were implanted at the Heart Institute. During the follow-up period of 33 +/- 12.8 months (range 0-50 months), total function loss in seven (10.6%) units and false threshold measurement of sensing and pacing in three (4.5%) patients were observed. Average time from implantation to malfunction was 37 months (range 28-42). Malfunction was unrelated to battery status and could not be predicted by any measures obtained during the pacemaker follow-up period. Kaplan Meyer survival curve predicted a 70% 4-year malfunction-free survival of that pacemaker model. Given this high rate of total malfunction and the unpredictable nature of its occurrence, the authors recommend the replacement of all remaining Minidual 50 units at risk, at least in dependent patients.

Adult↗

Impaired detection of ventricular tachyarrhythmias by a rate-smoothing algorithm in dual-chamber implantable defibrillators: intradevice interactions.

INTRODUCTION: Rate smoothing is an algorithm initially designed to prevent rapid changes in pacemaker rates. In this study, we sought to determine the potential of the rate-smoothing mechanism in preventing detection of ventricular tachyarrhythmias. METHODS AND RESULTS: Clinical testing of rate smoothing was performed at the time of defibrillator arrhythmia induction in 16 patients with implantable defibrillators during 65 episodes of ventricular tachyarrhythmias. We also performed simulator-based testing to assess detection of ventricular tachycardia between 170 and 220 beats/min with systematic sequential change of rate-smoothing percent, AV delay, and maximal rate. During clinical testing of 54 ventricular fibrillation/polymorphic ventricular tachyarrhythmia episodes, there were no cases of nondetection and 3 episodes (5%) of minimally delayed detection. Of 10 monomorphic ventricular tachyarrhythmias, 6 had either delayed (2 cases) or absent (4 cases) detection. During simulator testing, complex interrelationships were demonstrated in AV delay, upper rate, and rate-smoothing percent in determining the severity of the effect on detection. Generally, long AV delay, higher upper rate, and smaller (more aggressive) rate smoothing were associated with increased risk of ventricular tachyarrhythmia underdetection. Importantly, use of parameters that impaired detection was always accompanied by a programmer warning message. CONCLUSION: Rate smoothing may result in delay or failure of ventricular tachycardia detection. It is important to consider warning messages when programming rate smoothing and to test for appropriate detection when rate smoothing is used despite warning messages.

Algorithms↗