PubMed Health⌕ Search

Biomedical subjects

Michael L Boninger

Publications and source records attributed to Michael L Boninger.

At least 37 records · Page 2Linked to original sources

Assessing the influence of wheelchair technology on perception of participation in spinal cord injury.

OBJECTIVE: To investigate factors related to the wheelchair, impairment, and environment that affect perception of participation of persons with spinal cord injury (SCI) in activities performed in 3 settings: in the home, in the community, and during transportation. DESIGN: Cross-sectional study. SETTING: Research centers and a specialized assistive technology (AT) clinic in Pittsburgh (Pitt). Research centers and community-based rehabilitation technology suppliers in Saint Louis (SL). PARTICIPANTS: Seventy wheelchair users with SCI. INTERVENTIONS: Subjects from Pitt and SL completed a written survey of AT usage in daily activities. MAIN OUTCOME MEASURES: Subjects were asked 5 questions within each setting (home, community, transportation) related to their perceived reason for functional limitations. RESULTS: The wheelchair was the most commonly cited factor limiting participation, followed by physical impairment and physical environment. Twenty-one percent of subjects with paraplegia reported pain as a limiting factor for their transportation use, significantly more (P=.047) than subjects with tetraplegia (3%). A trend (P=.099) was seen toward a higher percentage of subjects with tetraplegia (tetraplegia, 7%; paraplegia, 3%) reporting lack of equipment as a limiting factor for use of transportation. Differences were also seen across sites. CONCLUSIONS: The wheelchair was the most commonly cited limiting factor, followed by physical impairment and physical environment. The wheelchair is the most important mobility device used by persons with SCI and the one that users most associate with barriers.

Activities of Daily Living↗

Impact of a pushrim-activated power-assisted wheelchair on the metabolic demands, stroke frequency, and range of motion among subjects with tetraplegia.

OBJECTIVES: To determine differences in metabolic demands, stroke frequency, and upper-extremity joint range of motion (ROM) during pushrim-activated power-assisted wheelchair (PAPAW) propulsion and traditional manual wheelchair propulsion among subjects with tetraplegia. DESIGN: Repeated measures. SETTING: A biomechanics laboratory within a Veterans Affairs medical center. PARTICIPANTS: Fifteen full-time manual wheelchair users who had sustained cervical-level spinal cord injuries. INTERVENTIONS: Participants propelled both their own manual wheelchairs and a PAPAW through 3 different resistances (slight, 10W; moderate, 12W; high, 14W) on a wheelchair dynamometer. Each propulsion trial was 3 minutes long. MAIN OUTCOME MEASURES: Primary variables that were compared between the 2 wheelchairs were participants mean steady-state oxygen consumption, ventilation, heart rate, mean stroke frequency, and maximum upper-extremity joint ROM. RESULTS: When using the PAPAW, participants showed a significant ( P <.05) decrease in mean oxygen consumption and ventilation throughout all trials. Mean heart rate was significantly lower when using the PAPAW for the high resistance trial. Stroke frequency was significantly lower when using the PAPAW for the slight and moderate resistances. Overall joint ROM was significantly lower when using the PAPAW. CONCLUSIONS: For subjects with tetraplegia, PAPAWs reduce the energy demands, stroke frequency, and overall joint ROM when compared with traditional manual wheelchair propulsion.

Adult↗

Demographic and socioeconomic factors associated with disparity in wheelchair customizability among people with traumatic spinal cord injury.

OBJECTIVES: To determine if a standard of care for wheelchair provision exists within the participating centers and if there is disparity in wheelchair customizability among the study sample. DESIGN: Convenience sample survey. SETTING: Thirteen Model Spinal Cord Injury Systems that provide comprehensive rehabilitation for people with traumatic spinal cord injury (SCI) and that are part of the national database funded through the US Department of Education. PARTICIPANTS: A total of 412 people with SCI who use wheelchairs over 40 hours a week. INTERVENTION: Survey information was obtained from subjects via telephone and in-person interviews and from the national database. Collected information included age, race, education, level of injury, and wheelchair funding source. MAIN OUTCOME MEASURES: Number and type (manual or power) of wheelchairs. Wheelchair customizability as defined by design features (eg, adjustable axle position, programmable controls). RESULTS: Ninety-seven percent of manual wheelchair users and 54% of power wheelchair users had customizable wheelchairs. No power wheelchair user received a wheelchair without programmable controls. Minorities with low socioeconomic backgrounds (low income, Medicaid/Medicare recipients, less educated) were more likely to have standard manual and standard programmable power wheelchairs. Older subjects were also more likely to have standard programmable power wheelchairs. CONCLUSIONS: The standard of care for manual wheelchair users with SCI is a lightweight and customizable wheelchair. The standard of care for power wheelchairs users has programmable controls. Unfortunately, socioeconomically disadvantaged people were less likely to receive customizable wheelchairs.

Activities of Daily Living↗

Using the absorbed power method to evaluate effectiveness of vibration absorption of selected seat cushions during manual wheelchair propulsion.

Although wheelchair users are frequently subjected to oscillatory and shock vibrations, little research has been conducted to assess the whole-body vibration exposure of wheelchair users. The purpose of this study was to determine if selected wheelchair cushions alter potentially harmful whole-body vibrations transferred to wheelchair users. Thirty-two participants, who use wheelchairs as their primary mode of mobility, contributed to this study. Four of the most commonly prescribed wheelchair cushions were selected. Participants were asked to propel their wheelchair over a simulated activities of daily living (ADL) course while acceleration and force data were recorded. A repeated measures ANOVA showed no significant differences between the different cushions for the total averaged absorbed power (p = 0.190), the 50 mm curb drop (p = 0.234), or the rumble strip (p = 0.143). A repeated measure ANOVA for the peak curb drop absorbed power revealed a significant difference in the cushions (p = 0.043). The cushions that were most effective in this testing appear to be the Invacare Pindot and the Varilite Solo. Not only did those cushions appear to have the lowest values much of the time but also they did not display the highest values. When comparing results from a similar study, absorbed power appears to be as effective in determining vibration effects in the time domain as the methods in the ISO 2631 Standard.

Adult↗

The GAME(Cycle) exercise system: comparison with standard ergometry.

BACKGROUND: It is well established that physical activity is beneficial to health. For the individual in a wheelchair, a regular exercise program might not be available or may be too difficult to participate in physically and/or psychologically. Many exercise devices and regimes are boring. The goal, therefore, is to develop a device that makes exercise more exciting and, thus, motivates a person to exercise more or for a longer period of time, yielding increased energy expenditure. Our laboratory developed an interface between an arm ergometer and a computer game that allows the user to control game play on the screen as if using a joystick. The purpose of this study was to determine (a) whether the GAME(Cycle) system would elicit an exercise effect similar to arm ergometry, (b) whether perceived exertion would be different between the 2 devices, and (c) individuals' impressions regarding the GAME(Cycle) system. METHODS: Thirteen individuals who used wheelchairs participated in the study. Participants were asked to exercise for 2 separate, 19-minute sessions. For 1 session, a GAME(Cycle) system was used and for the other session, the same arm ergometer was used, but without the computer game being played. Physiologic data and perceived exertion were collected for each session. RESULTS: There were significant differences between playing the game and not playing the game for VO2 (P = 0.03) and VCO2 (P = 0.02), with higher values being found when the game was played. Perceived exertion was not significantly different between the 2 trials. CONCLUSION: GAME(Cycle) appears to be similar in nature with respect to energy expenditure to arm ergometry. Because this study was conducted on athletes, further research is needed with sedentary individuals to determine exercise effects and perceived exertion.

Adult↗

Evaluation of selected sidewalk pavement surfaces for vibration experienced by users of manual and powered wheelchairs.

BACKGROUND: Obstacles such as bumps, curb descents, and uneven driving surfaces cause vibrations that affect the wheelchair, and in turn, the wheelchair user. Chronic exposure can cause low-back pain, disk degeneration, and other harmful effects. Little research has been conducted to assess the vibrations experienced by wheelchair users. OBJECTIVE: The purpose of this study was to conduct an evaluation of the vibration exposure during electric-powered wheelchair driving and mechanical energy requirements for manual wheelchair propulsion over selected sidewalk surfaces. The goal was to determine the criteria for a wheelchair-pedestrian access route that does not require excessive propulsive work or expose wheelchair users to potentially harmful vibrations. METHODS: Ten unimpaired individuals participated in this study. Six sidewalk surfaces were tested. Measured variables included power of the acceleration per octave, mechanical work to propel over surfaces, peak acceleration, and frequency at which peak acceleration occurs. RESULTS: For both the manual and electric-powered wheelchair, at 1 m/s, significant differences were found in peak accelerations between the seat and footrest (P < 0.0001) and between the sidewalk surfaces (P = 0.004). The greatest risk for injury caused by shock and vibration exposure occurs at frequencies near the natural frequency of seated humans (4-15 Hz). The values for work required to propel over the surfaces tested were not statistically significantly different. Besides appearance and construction, the only distinguishing characteristic was surface roughness caused by the joints. CONCLUSION: When treating the poured concrete sidewalk as the standard, surfaces 2, 3, 5, and 6 compared most favorably in terms of vibration exposure, whereas surface 4 produced mixed results. Surfaces 2, 3, 5, and 6 yielded results that were similar to the poured concrete sidewalk and could be considered acceptable for wheelchair users. In conclusion, surfaces other than the traditional poured concrete can be used for pedestrian access routes without adding vibration exposure or reducing propulsion efficiency.

Adult↗

Push for power.

Explore the source record for details and available documents.

Electric Power Supplies↗

Preliminary assessment of a prototype advanced mobility device in the work environment of veterans with spinal cord injury.

The INDEPENDENCE 3000 IBOT Transporter (IBOT) is an electronically stabilizing device for people with disabilities. The purpose of this study was to collect qualitative data on the potential for the IBOT to improve employment satisfaction of veterans who use wheelchairs to work. This study was based upon observations by trained clinicians, and responses to a survey completed by four men with traumatic spinal cord injury, who worked in an office environment. The mean age of the subjects was 52 +/- 8.8 years. The subjects used the devices to hold eye-level discussions with colleagues, climb stairs, ascend steep ramps, and negotiate curbs. When subjects were asked to rate the ease of getting around in the IBOT compared to their personal wheelchairs, they responded with a mean of 6.7 +/- 1.8 on a 10-point visual analog scale. The response to rating the overall function of the IBOT within their working environment yielded a rating of 6.0 +/- 2.8. Half of the users felt that the IBOT would help them at work and all thought it should be made available to veterans who use wheelchairs. A larger study should be conducted to determine if the IBOT affects work performance and the ability to return to work.

Employment↗

Reliability and diagnostic accuracy of the clinical examination and patient self-report measures for cervical radiculopathy.

STUDY DESIGN: A blinded, prospective diagnostic test study was conducted. OBJECTIVES: To assess the reliability and accuracy of individual clinical examination items and self-report instruments for the diagnosis of cervical radiculopathy, and to identify and assess the accuracy of an optimum test-item cluster for the diagnosis of cervical radiculopathy. SUMMARY OF BACKGROUND DATA: Although cervical radiculopathy remains largely a clinical diagnosis, the reliability and diagnostic accuracy of clinical examination items, individually or in combination, for cervical radiculopathy is largely unknown. METHODS: Patients with suspected cervical radiculopathy or carpal tunnel syndrome received standardized electrophysiologic examination of the symptomatic upper quarter followed by a standardized clinical examination by physical therapist examiners blinded to diagnosis. Diagnostic properties were assessed using a neural impairment reference criterion standard. RESULTS: The study involved 82 patients. More than two thirds of 34 clinical examination items had reliability coefficients rated at least fair or better, and 13 items had likelihood ratio point estimates above 2 or below 0.50. A single diagnostic test item cluster of four variables was identified and produced a positive likelihood ratio point estimate of 30.3. The 95% confidence intervals for all likelihood ratio point estimates in this study were wide. CONCLUSIONS: Many items of the clinical examination were found to be reliable and to have acceptable diagnostic properties, but the test item cluster identified was more useful for indicating cervical radiculopathy than any single test item. Upper limb tension Test A was the most useful test for ruling out cervical radiculopathy. Further investigation is required both to validate the test item cluster and to improve point estimate precision.

Adult↗

Seat and footrest shocks and vibrations in manual wheelchairs with and without suspension.

OBJECTIVE: To examine differences in the shock and vibration transmitted to an occupant of a manual wheelchair with and without suspension caster forks and with and without rear-suspension systems. DESIGN: Repeated-measures engineering testing. SETTING: Rehabilitation engineering center with a wheelchair standards test laboratory. SPECIMENS: Six manual wheelchairs. INTERVENTIONS: An American National Standards Institute/Rehabilitation Engineering and Assistive Technology Society of North America wheelchair test dummy and a Hybrid III test dummy were used to test shock and vibration transmission in wheelchairs equipped with original equipment manufacturer (OEM) caster forks and suspension caster forks. Ultralight wheelchairs, half of which had factory-equipped rear-suspension systems, were tested. Testing was conducted on a double-drum wheelchair test machine. MAIN OUTCOME MEASURES: Shocks were examined by using peak acceleration and the frequency at which peak acceleration occurs for the seat and footrest. Vibration was characterized by the acceleration power per octave for the seat and footrest. RESULTS: Significant differences were found in the peak accelerations at the seat (P=.0004) and footrest (P=.0007) between the wheelchairs with the OEM caster forks and those with the suspension casters. The wheelchairs with suspension had significantly different frequencies at which the peak accelerations occurred for both the seat (P=.01) and footrest (P=.0001). The wheelchairs with suspension caster forks had a lower total power per octave than the wheelchairs with the OEM caster forks. For the footrest vibrations, significant differences were found between the types of caster forks for all octaves except those associated with frequencies more than 78.75Hz. There were significant differences for wheelchairs with and without rear suspension for total power per octave of seat vibrations in the octaves between 7.81 and 9.84Hz (P=.01) and 12.40 and 15.63Hz (P=.008). CONCLUSIONS: Suspension caster forks reduce the shock and vibration exposure to the user of a manual wheelchair. Rear-suspension systems reduce some of the factors related to shock and vibration exposure, but they are not clearly superior to traditional designs.

Acceleration↗

Shoulder magnetic resonance imaging abnormalities, wheelchair propulsion, and gender.

OBJECTIVE: To investigate the relationship between pushrim forces and the progression of shoulder injuries in manual wheelchair users. DESIGN: Longitudinal case series. SETTING: Biomechanics laboratory and magnetic resonance imaging (MRI) facility at a Veterans Health Administration medical center and university hospital, respectively. PARTICIPANTS: Fourteen individuals with spinal cord injury (8 men, 6 women) who used manual wheelchairs. INTERVENTION: Subjects propelled their own wheelchairs on a dynamometer at 0.9 and 1.8m/s. Bilateral biomechanical data were obtained by using force and moment sensing pushrims at time 1. Bilateral shoulder MR images were also completed on 2 occasions, at time 1 and, approximately 2 years later, at time 2. MAIN OUTCOME MEASURES: The peak pushrim forces in a pushrim coordinate system were calculated, weight normalized and averaged over 5 strokes (presented as % body weight). MRI abnormalities were graded by using a summated scale. Differences between scores between times 1 and 2 were calculated. RESULTS: Subjects were divided into 2 groups based on change in MRI score. Seven subjects were in the group with worsening scores (MRI+; mean, 8.14 points; range, 5-16), and 7 were in the group with improving or unchanging scores (MRI-; mean, -1.00 point; range, -5 to 1). There was no significant difference between groups with respect to age, body mass index, or years from injury. There were significantly more women in the MRI+ group (6 women, 1 man) than in the MRI- group (7 men) (P=.001). The MRI+ group used significantly greater weight-normalized radial force, or force directed toward the axle at time 1, to propel their wheelchairs at each speed (P<.01): MRI+ at 0.9m/s (mean radial force +/- standard deviation, 5.2%+/-1.0%) and MRI- at 0.9m/s (mean radial force, 3.2%+/-1.7%) (P=.028); and MRI+ at 1.8m/s (mean radial force, 6.6%+/-1.2%) (P=.023) and MRI- at 1.8m/s (mean radial force, 4.1%+/-2.2%). In a separate analysis, women were found to propel with a significantly higher radial force. A logistic regression found a significant relationship between radial force at time 1 and increased risk of progression of MRI findings over time. CONCLUSION: Individuals who propel with a greater percentage of force directed toward the axle were at increased risk of progression of MRI findings over time. Most people in this group were women. Clinicians should instruct wheelchair users in effective propulsion techniques and should pay particular attention to women who use wheelchairs. Reducing forces during wheelchair propulsion may minimize the likelihood of developing shoulder injuries.

Adult↗

A pilot study on community usage of a pushrim-activated, power-assisted wheelchair.

Manual wheelchair propulsion combined with other stresses to the upper extremities may result in secondary injury. Possible solutions would be to devise alternative methods of propulsion, such as a pushrim-activated, power-assist wheelchair (PAPAW). The goals of this study were to examine the usage of the PAPAW in a real world setting and to characterize the driving habits of manual wheelchair users. Feedback was also obtained regarding subjects' opinions with respect to the PAPAW: their likes and dislikes. A PAPAW was provided to subjects for 2 weeks. Usage (average and total distance traveled and velocity) was tracked for both the PAPAW and the subjects' own wheelchairs. Significant differences in usage were not seen between the personal wheelchairs or the PAPAW. As a result, weeks were combined to provide an overall examination of driving characteristics. The average distance traveled over an average day was 1,671.4 +/- 314.8 m with an average velocity of 0.44 +/- 0.09 m/second. This pilot study provides an idea of manual wheelchair usage in a population of individuals with spinal cord injury. The lack of significant findings between the PAPAW and the subjects' own wheelchairs may be a function of study methodology such as sample size and length of follow-up in the new wheelchair. Future studies should expand upon the pilot work completed here, strengthening the design.

Adult↗

Analysis of whole-body vibration during manual wheelchair propulsion: a comparison of seat cushions and back supports for individuals without a disability.

Whole-body vibration exposure has been found to be detrimental to the health of humans owing to effects such as degraded comfort, disc degeneration, and lower back pain. The purpose of this study was to determine if selected seat cushions and back supports minimize the transmission of vibrations during manual wheelchair propulsion. Ten unimpaired participants traversed an activities of daily living course using four seat cushions and four back supports. Vibrations were measured using triaxial accelerometers. The time domain and frequency domain transmissibility was used to determine if differences exist among seat cushions and back supports. Differences were found among the four seat cushions and four back supports. Seat cushion and back support manufacturers should concentrate on single-event shocks and repeated shocks, as opposed to oscillatory motions and self-generated vibrations, because the vibrations generated by these events tend to reside in the range of frequencies most sensitive to humans. Vibrations in this range of frequencies have the greatest effect on the transmission of whole-body vibration during manual wheelchair propulsion. Differences among the seat cushions and back supports appear to be due to the seat cushion/back support design and postural support. From a clinical perspective, the time domain transmissibility best describes the transmission of whole-body vibration.

Acceleration↗

Use of the Independence 3000 IBOT Transporter at home and in the community.

BACKGROUND: The INDEPENDENCE 3000 IBOT Transporter (IBOT) is an electronically stabilizing mobility device for people with disabilities. It operates in 4 functions: Standard, Balance (raised on 2 rear wheels), 4 Wheel (for inclines, curbs, and uneven terrain), and Remote (for loading into a vehicle). OBJECTIVE: The purpose of this study was to observe the IBOT at use in the home and in the community. METHODS: Data were obtained via observations by trained clinicians, data recorded from a computerized data logger, and reports from each expert. PARTICIPANTS: Participants included 10 unimpaired nonwheelchair users (6 men, 4 women) and 4 expert wheelchair users (men with spinal cord injuries, T7-L1). The participants used the IBOT to perform a variety of activities, including holding eye-level discussions with colleagues and shopping by balancing on 2 wheels, going up and down steep ramps, traversing outdoor surfaces (eg, grass, dirt trails), and climbing curbs. OBSERVATIONS: The Balance and 4-Wheel functions were helpful and worked well. The IBOT required attention to control in the Standard function. The seat height was too high for most tables and desks, and the IBOT was challenging to use in the bathroom. CONCLUSION: The IBOT is a functional mobility device that expands the options of wheelchair users. It is most useful outdoors and where there is sufficient space to use its unique Balance function.

Activities of Daily Living↗

Range of motion and stroke frequency differences between manual wheelchair propulsion and pushrim-activated power-assisted wheelchair propulsion.

BACKGROUND/OBJECTIVE: The objective of this study was to examine the use and efficacy of a pushrim-activated power-assist wheelchair (PAPAW) in the reduction of upper extremity range of motion (ROM) and stroke frequency in manual wheelchair users. METHODS: Ten manual wheelchair users were evaluated using a repeated-measures design with and without the use of a PAPAW for maximum ROM of shoulder flexion/extension, abduction/adduction, internal/external rotation, and horizontal flexion/extension; elbow flexion/extension; wrist flexion/extension, supination/pronation, and ulnar/radial deviation; and stroke frequency. Participants propelled a Quickie 2 manual wheelchair configured as a PAPAW and their own wheelchair on a computer-controlled dynamometer at 3 different resistance levels and 2 different speeds. RESULTS: The use of the PAPAW significantly (P < 0.05) decreased shoulder flexion/extension and horizontal flexion/extension, elbow flexion/extension, and wrist flexion/extension and ulnar/radial deviation for many speed and resistance combinations. Univariate analysis revealed that stroke frequency was unaltered in all cases. CONCLUSION: These findings provide the foundation for studying the utility of the PAPAW in reducing the risk of upper limb injury and neuropathy in the manual wheelchair user population.

Adult↗

Investigating neck pain in wheelchair users.

OBJECTIVE: Despite the fact that wheelchair users are exposed to risk factors for neck and upper back pain (NP), little is known about the impact and possible diagnoses associated with NP. The purpose of this study was to examine the significance of NP in wheelchair users and to determine if a portion of the NP may be myofascial in origin. DESIGN: Cross-sectional cohort study using questionnaires and physical exams to evaluate NP in a convenience sample of wheelchair users from the National Veteran's Wheelchair Games. Main outcome measures included reported NP, visual analog scale of neck complaints, Neck Disability Index, and physical examination findings of trigger points. RESULTS: Sixty-six percent of subjects reported NP since becoming a wheelchair user and, 60% reported pain during the past month. Neither age nor length of time in a wheelchair was significantly different between those subjects who did and those subjects who did not report pain. Of those respondents who reported NP, 60% visited the doctor about the pain and 40% limited their daily activities due to the pain. Trigger-point palpation reproduced pain in 54% of those respondents who experienced pain in the past month (n = 34). CONCLUSION: This study provides a first step in defining the prevalence and significance of NP among wheelchair users. Clinicians who work with this population need to ask subjects about symptoms and consider a myofascial origin for that pain when considering treatment.

Adult↗

Peer review: issues in physical medicine and rehabilitation.

Peer review, although the standard for evaluating scientific research, is not without flaws. Peer reviewers have been shown to be inconsistent and to miss major strengths and deficiencies in studies. Both reviewer and author biases, including conflicts of interest and positive outcome publication biases, are frequent topics of study and debate. Additional concerns have been raised regarding inappropriate authorship and adequate reporting of the ethical process involving human and animal experimentation. Despite these issues, a good peer review can provide positive feedback to authors and improve the quality of research reported in medical journals. This article reviews some issues and points of concern regarding the peer-review process, and it suggests guidelines for new (and established) reviewers in the area of physical medicine and rehabilitation. It also provides suggestions for editorial considerations and improvements in the peer-review process for physical medicine and rehabilitation research journals.

Ethics, Research↗

Whole-body vibration during manual wheelchair propulsion with selected seat cushions and back supports.

Although the exposure to whole-body vibrations (WBV) has been shown to be detrimental to seated humans, the effects of wheelchairs and seating systems on the transmission of vibration to an individual have not been thoroughly examined. The purpose of this study was to determine if the selected wheelchair seat cushions and back supports minimize the transmission of vibrations. Thirty-two wheelchair users traversed an activities of daily living course three times using 16 randomly selected seating systems as well as their own. Vibrations were measured using triaxial accelerometers at the seat and participant's head. The weighted fore-to-aft (Tx), vertical (Tz), and resultant (Tr) transmissibility based on the vibrational-dose-value (VDV) were used to determine if differences existed among the four seat cushions and back supports. The obstacles that seem to have the largest effect on the transmission of WBV are the single event shocks and the repeated event shocks. Comparisons between the individuals own seating system and the tested seating systems suggest that the individuals are not using the most appropriate seating system in terms of the reduction of vibration transmission.

Acceleration↗