Proper propulsion.

Explore the source record for details and available documents.

Equipment Design↗

The science behind mobility devices for individuals with multiple sclerosis.

There is a growing body of research related to prescription of mobility devices. This research enables clinicians and clients to make clinical decisions related to mobility based on sound research. Unfortunately, there is little research investigating appropriate prescriptions in degenerative disorders such as multiple sclerosis (MS). In this article we will review the literature on mobility devices in MS and how it can be used to assist with clinical decision-making considering the progressive nature of this condition. In addition, we will review other research not conducted on individuals with MS that is relevant to this population. Finally we will present a call for future research that should help address this critical area.

Canes↗

Comparison of virtual and real electric powered wheelchair driving using a position sensing joystick and an isometric joystick.

There are limited interface options for electric powered wheelchairs, which results in the inability of some individuals to drive independently. In addition, the development of new interface technologies will necessitate the development of alternative training methods. This study compares a conventional position sensing joystick to a novel isometric joystick during a driving task in a virtual environment and a real environment. The results revealed that there were few differences in task completion time and root-mean-square error (RMSE) between the two types of joysticks. There were significant correlations between the RMSE in the virtual environment and the real environment for both types of joysticks. The data indicate that performance in the virtual environment was representative of driving ability in the real environment, and the isometric joystick performed comparably to the position sensing joystick.

Algorithms↗

Driving characteristics of electric-powered wheelchair users: how far, fast, and often do people drive?

OBJECTIVES: To determine the driving characteristics of electric-powered wheelchair users during unrestricted community activities and to compare the activity levels among an active group and a group of regular users. DESIGN: Multisite engineering evaluation of electric-powered wheelchair driving activity during unrestricted community mobility. SETTING: Data were collected in the communities of Pittsburgh, PA, and the National Veterans Wheelchair Games (NVWG) in San Antonio, TX. PARTICIPANTS: Seventeen people participated, all of whom used electric-powered wheelchairs as their primary means of mobility. INTERVENTION: Each subject was asked standarized questions about self and wheelchair use. Data logger and sensor installed on wheelchair. Data downloaded from logger. MAIN OUTCOME MEASURES: Speed, distance traveled, and the time that each subject's personal wheelchair was being driven were recorded for 24hr/d over approximately 5 days for each subject by using a custom-built data logger. RESULTS: The NVWG group traveled faster than the Pittsburgh group, but this difference was only statistically significant on the first day. The NVWG group was more likely to travel longer than the Pittsburgh group with significant differences seen in day 4 (P = .03) and day 5 (P = .05). Total distance traveled during the 5-day period and average distance traveled per day were also significantly different between the groups (P = .02 for both 5-day distance and daily distance), with the NVWG group traveling longer (17,164 +/- 8708m) when compared with the Pittsburgh group (8335 +/- 7074m) over the 5-day period. Both distance traveled and speed increased during afternoon and evening hours. The maximum distance traveled by any subject for each hour across the 2 groups was used to create the theoretic maximum distance day, which resulted in 7970m of driving. CONCLUSION: Drivers of electric-powered wheelchairs are most active during the afternoon and evening hours. Over the 5-day period of this study, there was little variation in the speed or distance driven per day. The subjects participating in the NVWG were more active than their counterparts during a typical week at home. The maximum theoretic distance that a wheelchair user in our group would travel is less than 8km. The range of current electric-powered wheelchairs appears adequate, if not generous, for the subjects in our study.

Activities of Daily Living↗

Propulsion patterns and pushrim biomechanics in manual wheelchair propulsion.

OBJECTIVES: To classify stroke patterns of manual wheelchair users and to determine if different patterns of propulsion lead to different biomechanics. DESIGN: Case series. SETTING: Biomechanics laboratory. PARTICIPANTS: Thirty-eight individuals with paraplegia who use manual wheelchairs for mobility. INTERVENTION: Subjects propelled their own wheelchair on a dynamometer at 2 different steady state speeds. Bilateral biomechanical data were obtained by using a force and moment sensing pushrim and a motion analysis system. MAIN OUTCOME MEASURES: The propulsive stroke of each participant for each speed and side was classified as following 1 of 4 patterns. These 4 patterns were then compared by using a mixed-model analysis of variance. The biomechanical variables that were compared were cadence, peak and rate of rise of the resultant force, mechanical effective force, push angle, and ratio of time spent pushing to time in recovery. RESULTS: The most common propulsive stroke involved the user lifting the hand over the pushrim during the recovery phase. The stroke pattern was independent of axle position and varied from side to side and between speeds. After controlling for subject characteristics, significant differences were observed between stroke patterns in cadence and ratio of time spent pushing to time in recovery. A stroke pattern that involves using a semicircular motion with the hand below the pushrim during the recovery phase of the propulsion stroke was associated with a lower cadence and more time spent in the push phase relative to the recovery phase. CONCLUSION: The semicircular motion of propulsion displayed characteristics consistent with reduced repetition and more efficient propulsion. Use of this propulsion style may reduce trauma to the upper extremities. Clinicians should consider training individuals in this propulsion style.

Adult↗

Intelligent walkers for the elderly: performance and safety testing of VA-PAMAID robotic walker.

A walker that could help navigate and avoid collisions with obstacles could help reduce health costs and increase the quality of care and independence of thousands of people. This study evaluated the safety and performance of the Veterans Affairs Personal Adaptive Mobility Aid (VA-PAMAID). We performed engineering tests on the VA-PAMAID to determine safety factors, including stability, energy consumption, fatigue life, and sensor and control malfunctions. The VA-PAMAID traveled 10.9 km on a full charge and avoided obstacles while traveling at a speed of up to 1.2 m/s. No failures occurred during static stability, climatic, or fatigue testing. Some problems were encountered during obstacle climbing and sensor and control testing. The VA-PAMAID has good range, has adequate reaction time, and is structurally sound. Clinical trials are planned to compare the device to other low-technical adaptive mobility devices.

Equipment Design↗

Using wavelet analysis to characterize the thermoregulatory mechanisms of sacral skin blood flow.

Pressure-induced skin blood flow responses measured via laser Doppler flowmetry are commonly reported in the time domain. The usefulness of spectral analysis in examining blood flow control mechanisms has been demonstrated, but traditional Fourier analysis does not provide sufficient resolution to reveal characteristic low frequencies. Time-frequency (wavelet) analysis was performed on 10 subjects' sacral skin blood flow responses to heating (45 degrees C) with improved resolution. Five frequency bands were identified (0.008-0.02 Hz, 0.02-0.05 Hz, 0.05-0.15 Hz, 0.15-0.4 Hz, and 0.4-2.0 Hz) corresponding to metabolic, neurogenic, myogenic, respiratory, or cardiac origins. Significant differences were observed in the mean normalized power of the metabolic (p < 0.01) and myogenic frequency bands (p < 0.01) between preheating and maximal heating and preheating and postheating periods. Power increased for the metabolic frequency and decreased for the myogenic frequency. Wavelet analysis successfully characterized thermoregulatory control mechanisms by revealing the contributions of the physiological rhythms embedded in the blood flow signal.

Adult↗

Pushrim biomechanics and injury prevention in spinal cord injury: recommendations based on CULP-SCI investigations.

Over 50 percent of manual wheelchair users with spinal cord injury (SCI) are likely to develop upper-limb pain and injury. The majority of studies related to pain have implicated wheelchair propulsion as a cause. This paper draws from a large multisite trial and a long-standing research program to make specific recommendations related to wheelchair propulsion that may decrease the risk of upper-limb injury. The studies include over 60 subjects over 1 yr after a traumatic SCI below the second thoracic level. Specific aspects of the propulsive stroke that may relate to injury include cadence, magnitude of force, and the pattern of the hand during the nonpropulsive part of the stroke. Lower peak forces, slower cadence, and a circular propulsive stroke in which the hand falls below the pushrim during recovery may help prevent injury. In addition, wheelchair users should use the lightest weight adjustable wheelchair possible. Future work should include interventional trials and larger studies that allow for more complex statistical models that can further detail the relationship between wheelchair propulsion, user characteristics, and upper-limb injuries.

Adult↗

A kinetic analysis of manual wheelchair propulsion during start-up on select indoor and outdoor surfaces.

The objective of this study was to conduct a kinetic analysis of manual wheelchair propulsion during start-up on select indoor and outdoor surfaces. Eleven manual wheelchairs were fitted with a SMART(Wheel) and their users were asked to push on a course consisting of high- and low-pile carpet, indoor tile, interlocking concrete pavers, smooth level concrete, grass, hardwood flooring, and a sidewalk with a 5-degree grade. Peak resultant force, wheel torque, mechanical effective force, and maximum resultant force rate of rise were analyzed during start-up for each surface and normalized relative to their steady-state values on the smooth level concrete. Additional variables included peak velocity, distance traveled, and number of strokes in the first 5 s of the trial. We compared biomechanical data between surfaces using repeated-measures mixed models and paired comparisons with a Bonferroni adjustment. Applied resultant force (p = 0.0154), wheel torque (p < 0.0001), and mechanical effective force (p = 0.0047) were significantly different between surfaces. The kinetic values for grass, interlocking pavers, and ramp ascent were typically higher compared with tile, wood, smooth level concrete, and high- and low-pile carpet. Users were found to travel shorter distances up the ramp and across grass (p < 0.0025) and had a higher stroke count on the ramp (p = 0.0124). While peak velocity was not statistically different, average velocity was slower for the ramp and grass, which indicates greater wheelchair/user deceleration between strokes. The differences noted between surfaces highlight the importance of evaluating wheelchair propulsion ability over a range of surfaces.

Adult↗

Filter frequency selection for manual wheelchair biomechanics.

Wheelchair locomotion is an important form of mobility for many individuals with spinal cord injury. However, manual wheelchair propulsion can lead to upper-limb pain and can be very inefficient. This has led investigators to apply biomechanics to the study of wheelchair use. The objectives of this study were (1) to determine the frequency content of the motion of both hands during two speeds of wheelchair propulsion, (2) to obtain the filter frequencies necessary to remove noise from wheelchair motion data, and (3) to provide signal-to-noise ratio data for wheelchair kinematics. The participants in this study were a random sample of manual wheelchair users with paraplegia caused by spinal cord injury. Subjects propelled their personal wheelchairs on a computer-controlled dynamometer at speeds of 0.9 m/s and 1.8 m/s. Motion data were collected at 60 Hz with the use of a commercial infrared marker-based system. The main outcome measures were arm motions and noise frequency spectra, filter cutoff frequencies, and signal-to-noise ratio. Our results indicate that there is no useful signal power above 6 Hz during manual wheelchair propulsion at the speeds that we analyzed. In many cases, there was no useful signal power above 4 Hz. This would indicate that the frequency content of manual wheelchair propulsion is similar to that of human gait. The mean signal-to-noise ratio varied from a high of 91 dB to a low of 21.8 dB. The signal-to-noise ratio was greatest in the x direction (along the line of progression) and lowest in the z direction (medial-lateral). Manual wheelchair propulsion kinematic data should be low-pass filtered at approximately 6 Hz for speeds at or below 1.8 m/s. The data presented in the archival literature appear to have been filtered at an appropriate frequency.

Adult↗

Freestyle seating.

Explore the source record for details and available documents.

Arm↗