Clinical value of manual fusion of PET and CT images in patients with suspected recurrent colorectal cancer.

OBJECTIVE: The purpose of this study was to compare the diagnostic performance of manually fused PET images obtained using 18F-FDG and CT images with that of CT alone, PET alone, and conventional side-by-side review of PET images and CT images (hereafter referred to as "PET + CT") in patients with suspected recurrent colorectal cancer. MATERIALS AND METHODS: Ethics committee approval and informed consent were obtained. Sixty-three patients with suspected recurrent colorectal cancer underwent whole-body 18F-FDG PET followed by diagnostic CT. The acquired PET and CT images were merged on a workstation on a pixel-to-pixel basis. CT, PET, PET + CT, and fused images were evaluated separately in terms of the presence or absence of recurrence, new metastases, or both using a 5-point grading scale (0 = definitely negative, 1 = probably negative, 2 = equivocal, 3 = probably positive, and 4 = definitely positive). Lesions determined to be grade 3 or 4 were considered positive, and diagnostic accuracy and certainty were evaluated with statistical analysis using the chi-square test for independence. RESULTS: Of 119 pathologically or clinically confirmed lesions in 36 patients, evaluation of CT, PET, PET + CT, and fused images resulted in the detection of 75 (63%), 84 (71%), 91 (76%), and 111 (93%) lesions, respectively (p < 0.01) with the number of grade 4 lesions detected being 59 (50%), 72 (61%), 84 (71%), and 108 (91%), respectively (p < 0.01). Overall, the diagnostic accuracy of CT, PET, PET + CT, and fused images according to patient were 78%, 79%, 84%, and 92%, respectively (p = 0.13). CONCLUSION: Interpreting fused images provided more accurate diagnoses than interpreting CT, PET, or PET + CT images. This method of manually fusing separately obtained PET and CT images increased the diagnostic certainty for detecting colorectal cancer recurrence and decreased the number of equivocal cases.

Adult↗

[Comparison of noise equivalent count rate and image quality for two-dimensional and three-dimensional PET scans].

The aim of this study was to investigate the correlation between noise equivalent count (NEC) rates and the signal-to-noise ratio (S/N) in reconstructed images. The NEC rates were determined using uniform 20 cm and 70 cm tall, 20 cm diameter cylinders filled with 11C. The phantoms were scanned in both two-dimensional and three-dimensional modes. The reconstructed image noise was evaluated using FBP and OSEM algorithms (4 iterations and 8 subsets). The images were filtered to a final image resolution of 6.5 mm. From the reconstructed image sets, averages and standard deviations of images were generated, from which the average image S/N (=average/standard deviation) was calculated within an 18 cm central ROI. The S/N of a central slice and an end slice was compared with the NEC. The NEC was found to have a linear relationship to the image S/N of all slices, depending on differences in noise properties specific to the reconstruction algorithm. In two-dimensional mode, although the image S/N of the central slice and the edge slice showed a linear relationship with the NEC, in three-dimensional mode, the S/N of the central slice did not show a relationship with the NEC. The linear relationship was also found in both two- and three-dimensional acquisition modes, as well as for the different activity distributions. These results indicate that the NEC is not only a measure for comparing the count rate performance of imaging systems. However, an absolute evaluation is impossible to depend on reconstruction algorithm, slice number, and phantom type.

Algorithms↗

[Accuracy of attenuation coefficient obtained by 137Cs single-transmission scanning in PET: comparison with conventional germanium line source].

UNLABELLED: Transmission scanning can be successfully performed with a Cs-137 single-photon-emitting point source for three-dimensional PET imaging. This method was effective for postinjection transmission scanning because of differences in physical energy. However, scatter contamination in the transmission data lowers measured attenuation coefficients. The purpose of this study was to investigate the accuracy of the influence of object scattering by measuring the attenuation coefficients on the transmission images. We also compared the results with the conventional germanium line source method. METHODS: Two different types of PET scanner, the SET-3000 G/X (Shimadzu Corp.) and ECAT EXACT HR(+) (Siemens/CTI) , were used. For the transmission scanning, the SET-3000 G/X and ECAT HR(+) were the Cs-137 point source and Ge-68/Ga-68 line source, respectively. With the SET-3000 G/X, we performed transmission measurement at two energy gate settings, the standard 600-800 keV as well as 500-800 keV. The energy gate setting of the ECAT HR(+) was 350-650 keV. The effects of scattering in a uniform phantom with different cross-sectional areas ranging from 201 cm(2) to 314 cm(2) to 628 cm(2) (apposition of the two 20 cm diameter phantoms) and 943 cm(2) (stacking of the three 20 cm diameter phantoms) were acquired without emission activity. First, we evaluated the attenuation coefficients of the two different types of transmission scanning using region of interest (ROI) analysis. In addition, we evaluated the attenuation coefficients with and without segmentation for Cs-137 transmission images using the same analysis. The segmentation method was a histogram-based soft-tissue segmentation process that can also be applied to reconstructed transmission images. RESULTS: In the Cs-137 experiment, the maximum underestimation was 3% without segmentation, which was reduced to less than 1% with segmentation at the center of the largest phantom. In the Ge-68/Ga-68 experiment, the difference in mean attenuation coefficients was stable with all phantoms. CONCLUSION: We evaluated the accuracy of attenuation coefficients of Cs-137 single-transmission scans. The results for Cs-137 suggest that scattered photons depend on object size. Although Cs-137 single-transmission scans contained scattered photons, attenuation coefficient error could be reduced using by the segmentation method.

Cesium Radioisotopes↗

[Optimization of basic adjustable data-acquisition parameters for continuous three-dimensional whole-body FDG-PET].

UNLABELLED: The SET-3000 G/X (Shimadzu Corp., Kyoto, Japan) has a large aperture and functions as a three-dimensional (3D) dedicated PET scanner. However, the large number of line of responses in the SET-3000 G/X scanner creates a large volume of sinogram data and prolongs reconstruction time in iterative reconstruction. The purpose of this study was to optimize basic acquisition parameters (maximum ring difference and span) for sensitivity and spatial resolution for 3D whole-body (18)F-FDG PET. METHODS: Detector rings and image planes numbered 50 and 99, respectively. In sensitivity measurement, the maximum ring difference (MRD) was changed from 1 to 49. In the measurement of spatial resolution, the span was changed from 3 to 21. For sensitivity and spatial resolution measurements, the standard protocols defined by the Japan Radioisotope Association (JRIA) 1994 and the National Electrical Manufacturers Association (NEMA) NU 2-2001 were used. We also evaluated the corresponding image noise by placing identical ROI on the reconstructed images. RESULTS: The total sensitivity of MRD=49 was 85.7 cps/Bq/ml in a uniform phantom (15 cm diameter, 30 cm tall cylinder) filled with (18)F. This was approximately two times higher than MRD=13. The image noise in the center of the axial FOV decreased with increasing MRD. Spatial resolution was slightly decreased as MRD increased, but axial resolution deteriorated with a span of more than 11. CONCLUSION: Optimum basic data-acquisition parameters for whole-body (18)F-FDG PET were MRD 49 to obtain maximum sensitivity and span 9 to avoid decreasing spatial resolution. Additionally, it was concluded that the basic data-acquisition parameters should be carefully selected for 3D whole-body (18)F-FDG PET in order to maximize the efficiency of PET measurement.

Electronic Data Processing↗

Performance of list mode data acquisition with ECAT EXACT HR and ECAT EXACT HR+ positron emission scanners.

Recently, list mode (event-by-event) data acquisition with positron emission tomography (PET) has been widely noticed because list mode acquisition is superior to conventional frame mode data acquisition in terms of (1) higher efficiency of data storage, (2) higher temporal resolution, and (3) higher flexibility of data manipulation. The aim of this study is to investigate the performance of list mode data acquisition with ECAT EXACT HR and HR+ PET scanners (CTI PET Systems) and its feasibility in clinical applications. A cylindrical phantom (16 cm in diameter and length) filled with a 11C solution for the HR and a 15O solution for the HR+ was scanned several times by varying the radioactivity concentration with the list mode and frame mode acquisitions. The scans were also carried out with a septa (2D mode) and without a septa (3D mode) in order to evaluate the effect of the interplane septa on the quality of the list mode data. The acquired list mode data were sorted into a sinogram and reconstructed using a filtered back-projection algorithm. The count rate performance of the list mode data was comparable to that of the frame mode data. However, the list mode acquisition could not be performed when the radioactivity concentration in the field-of-view was high (exceeding 24 kBq/ml for the 3D mode) due to a lack of sufficient transfer speed for sending data from the memory to hard disk. In order to estimate the pixel noise in a reconstructed image, ten replicated data sets were generated from one list mode data. The reconstructed images with the 3D mode had a signal-to-noise ratio that was more than 60% better than that of the image with the 2D mode. The file size of the generated list mode data was also evaluated. In the case of ECAT EXACT HR+ with the 3D list mode, the list mode data with a generated file size of 2.31 Mbytes/ s were generated for 37 MBq injections. Our results suggest that careful attention must be paid to the protocol of the list mode data acquisition in order to obtain the highest performance of the PET scanner.

Algorithms↗

Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard.

UNLABELLED: The SET-3000 G/X (clinical tomograph with high resolution and a large axial field of view) is a 3-dimensional (3D) (only) dedicated PET camera with germanium oxyorthosilicate (GSO) and bismuth germanate (BGO) scintillators. The main characteristic of the SET-3000 G/X PET scanner is 3D continuous-emission and spiral-transmission (CEST) scanning, yielding a reduction in whole-body scan time. We evaluated the physical performance of the SET-3000 G/X PET scanner with the National Electrical Manufacturers Association (NEMA) NU 2-2001 standard. METHODS: A GSO 3D emission scanner is combined with a BGO transmission scanner separated axially by a lead shield. In the GSO scanner, small and thick scintillators (2.45 x 5.1 x 30 mm(3)) are arranged in small blocks (23.1 x 52 mm) to achieve high resolution and a high counting rate. The detector ring has a large solid angle with a diameter of 664 mm and an axial coverage of 260 mm (50 rings). The transmission scanner consists of BGO block detectors with a diameter of 798 mm and an axial width of 23.1 mm and is equipped with a rotating (137)Cs point source of 740 MBq and a tungsten collimator. The low- and high-energy thresholds are set to 400 and 700 keV, respectively, in the emission system. The coincidence time window is set to 6 ns. In CEST acquisition, the patient couch moves continuously through the emission and transmission scanners in a 1-way motion. Emission coincidence data are acquired in the histogram mode with on-the-fly Fourier rebinning, and transmission single data are acquired with emission contamination correction. RESULTS: With the NEMA NU 2-2001 standard, the main performance results were as follows: the average (radial and tangential) transverse and axial spatial resolutions (full width at half maximum) at 1 cm and at 10 cm off axis were 3.49 and 5.04 mm and 4.48 and 5.40 mm, respectively; the average sensitivity for the 2 radial positions (0 and 10 cm) was 20.71 cps/kBq; the scatter fraction was 50%; the peak noise equivalent count rate was 62.3 kcps at 9.8 kBq/mL; and the peak random rate was 542.1 kcps at 37.6 kBq/mL. CONCLUSION: The new integrated SET-3000 G/X PET scanner has good overall performance, including high resolution and sensitivity, and has the potential of reducing whole-body acquisition time to less than 10 min while improving small-lesion detectability with a low radiation dose.

Equipment Design↗

Annular geometry in patients with chronic ischemic mitral regurgitation: three-dimensional magnetic resonance imaging study.

BACKGROUND: Although animal studies showed that annular remodeling may be related to the pathogenesis of chronic ischemic mitral regurgitation (CIMR), little was known in humans. A better understanding of the precise 3D geometry of the mitral valvular-ventricular complex in CIMR is needed to devise a better surgical technique. The purpose of the study was to elucidate mitral annular geometry in patients with CIMR using cardiac MRI. METHODS AND RESULTS: Thirty-eight patients with previous inferior or posterior myocardial infarction were studied. With the 3D reconstruction of the mitral annulus and subvalvular apparatus from a series of longitudinal cine MRIs, end-systolic mitral annulus dimensions and 3D geometry were calculated. Patients were grouped by mitral regurgitation grade using echocardiography (> or =2+, n=15 versus < or =1+, n=23). Both septal-lateral and commissure-commissure mitral annular diameters were significantly greater in CIMR(+) patients (35+/-5 versus 30+/-4 mm, P=0.005; 46+/-6 versus 39+/-4 mm, P<0.001, respectively). The length of the fibrous annulus was significantly larger in CIMR(+) patients (28+/-3 versus 24+/-3 mm; P<0.001). The height of the annular "saddle horn" above a best-fit plane was lower in CIMR(+) patients (4.2+/-1.2 versus 6.0+/-1.8 mm; P=0.002), and the annular height to commissural width ratio was significantly lower in CIMR(+) patients (12+/-3 versus 21+/-5%; P<0.001). CONCLUSIONS: Patients with CIMR had greater septal-lateral and commissure-commissure mitral annular dimension, larger intertrigonal distance, and flattened saddle shape of mitral annulus. These associated geometric alterations may be important in the pathogenesis of CIMR.

Adult↗

An intra-operative positron probe with background rejection capability for FDG-guided surgery.

For radio-guided surgery on tumors using F-18-FDG, detection of annihilation gamma photons emanating from other parts of the body produces background radiation counts and limits its use in clinical situations. To overcome this limitation, we have developed an intra-operative positron probe with background-rejection capability. The positron probe uses a phoswich detector composed of a plastic scintillator and a bismuth germinate (BGO). A positron from a positron emitter such as F-18 is detected by the plastic scintillator and emits annihilation photons. The BGO detects one of the annihilation photons while a photo-multiplier tube (PMT) detects scintillation photons from both scintillators. The decay time differences of these two scintillators are used to distinguish whether the event is a true event where a positron and a following annihilation photon are detected simultaneously, or a background event. In this configuration, only positrons can be selectively detected, even in an environment of high background gamma photon flux. Spatial resolution was 11-mm full width at half maximum (FWHM) 5 mm from the detector surface. Measured sensitivity for the F-18 point source was 2.6 cps/kBq 5 mm from the detector surface. The background count rate was less than 0.5 cps for a 20-cm diameter cylindrical phantom containing 37 MBq of F-18 solution measured on the phantom surface, while the positron count rate was almost linear over a range of approximately 6 kcps. These results indicate that our developed intra-operative positron probe is valuable for radio-guided surgery on tumors using F-18-FDG in a high flux of background annihilation gamma photons.

Background Radiation↗

Investigation of single, random, and true counts from natural radioactivity in LSO-based clinical PET.

OBJECTIVE: Lutetium oxyorthosilicate (LSO) contains natural radioactivity that emits beta particles and three gamma photons simultaneously. These beta particles and gamma photons increase the single and random rates in a positron emission tomography (PET) system while a beta particle and gamma photon produced in the same decay of Lu-176 and detected by another detector can be beta-gamma coincidence true events. The purpose of this work is to measure the single, random, and true count rates due to the natural radioactivity in LSO and determine the optimum lower energy threshold level for an energy window in an LSO-based clinical PET. METHODS: First, we measured the energy spectra of these beta particles and gamma photons in LSO using a single crystal to obtain the basic data. Then, we measured single, random, and true count rates of an LSO-based clinical PET from the natural radioactivity as a function of the lower energy threshold. RESULTS: In the PET, single and random count rates due to the natural background activity were gradually decreased as the lower energy threshold level increased. The true count rates due to the beta-gamma coincidence were more than 10 kcps below a lower energy threshold of 250 keV. However, these true count rates due to the natural radioactivity in LSO can be decreased to less than 1 kcps at a lower energy threshold level set at more than 350 keV. CONCLUSION: With these considerations, in an LSO-based clinical PET, a lower energy threshold level set at above 350 keV is recommended.

Artifacts↗

Accuracy of image fusion using a fixation device for whole-body cancer imaging.

OBJECTIVE: The purpose of this study was to evaluate the clinical feasibility of a simple image fusion technique with PET and CT images acquired separately using a vacuum cushion as a fixation device. SUBJECTS AND METHODS: Forty-four patients underwent whole-body PET using 18F-fluoro-2-deoxy-D-glucose (FDG) followed by CT with IV contrast material. The patients were carefully fixed in an individually molded cushion to provide the same positioning for both examinations. The PET and CT images were fused on a workstation by using the lower margin of the urinary bladder as a reference. The degree of misregistration was evaluated for the physiologic uptake of the liver and kidneys and for the pathologic uptake of lesions. RESULTS: The average deviation of the center point of the liver between the two images was 6.6 +/- 8.7 (SD) mm in the craniocaudal direction, 1.9 +/- 5.1 mm in the anteroposterior direction, and 2.3 +/- 7.0 mm in the right-left direction. This value in the craniocaudal direction was 4.7 +/- 8.7 mm in the right kidney and 4.0 +/- 8.8 mm in the left kidney. Above the diaphragm, the deviations of the center point of movable and static lesions were 11.7 +/- 3.4 mm and 10.4 +/- 5.3 mm, respectively. Below the diaphragm, those of movable and static lesions were 9.7 +/- 2.5 mm and 6.9 +/- 2.9 mm, respectively. CONCLUSION: Our preliminary data indicate that this technique is a simple and practical method for manual image fusion that may be acceptable in clinical settings.

Feasibility Studies↗

Usefulness of L-[methyl-11C] methionine-positron emission tomography as a biological monitoring tool in the treatment of glioma.

OBJECT: The authors retrospectively analyzed the data obtained in patients who had undergone L-[methyl-11C] methionine (MET)-positron emission tomography (PET) studies to clarify the relationship between MET uptake and tumor biological features and to discuss the clinical usefulness of MET-PET studies. METHODS: One hundred ninety-four patients with cerebral glioma or suspected glioma underwent PET scanning 20 minutes after injection of MET, whose uptake into the tumor was expressed as a ratio to contralateral healthy brain tissue (T/N ratio). Analyses were performed to determine how MET uptake correlated with tumor pathological features and prognosis. The T/N ratios before and after various treatments were also examined. There were significant differences in the T/N ratio among the nonneoplastic lesions, low-grade gliomas, and malignant gliomas. Furthermore, there were significant correlations between patient survival and pretreatment T/N ratios. Among patients with malignant gliomas, a significant difference in survival was observed between cases with and without postoperative tumor remnant based on elevated MET uptake. The MET uptake was heterogeneous even among the homogeneous tumor areas demonstrated on MR imaging. Malignant pathological features were detected in the areas with the highest MET uptake. The effectiveness of radiotherapy or chemotherapy was expressed as a significantly decreased T/N ratio in some of the tumor types. CONCLUSIONS: The ability of MET-PET to reflect the biological nature of gliomas makes it an excellent method for monitoring active tumor tissue, and treatments based on its findings should provide a powerful clinical protocol in the course of glioma therapy.

Brain Neoplasms↗

Validation of anatomical standardization of FDG PET images of normal brain: comparison of SPM and NEUROSTAT.

PURPOSE: Statistical parametric mapping (SPM) and NEUROSTAT (NS) are widely used for intersubject statistical analysis of brain images. We investigated individual anatomical variations after standardization of 18F-fluorodeoxyglucose positron emission tomography (FDG PET) images of normal brain and compared the differences in the standardized images obtained from SPM and NS. METHODS: Twenty healthy normal subjects were recruited for FDG PET and magnetic resonance imaging (MRI) studies. Sylvian fissures (SF), cingulate sulci (CingS) and central sulci (CtlS) were marked on the brain surface of each individual's co-registered MR images. Then spatial standardization was performed on each subject's PET images using SPM99 and NS with NS's FDG template image, and each subject's MR images (with the SF, CingS, and CtlS marked in advance) were standardized using the sets of parameters obtained from PET standardization by SPM and NS, respectively. The coordinates of each subject's SF, CingS, and CtlS detected on the MR images standardized by the two methods were measured and compared with those on the template images. RESULTS: The mean individual deviations from the averaged coordinates for the markers on the SF, CingS and CtlS standardized by SPM and by NS were no more than 0.21-1.15 mm. The number of voxels within the brain volume on standardized MR images of all 20 subjects was 88.0% of the total number of brain volume voxels for SPM and 85.3% for NS. CONCLUSION: This study demonstrates that SPM and NS yield relatively small differences in standardization and that both methods are effective and valid for PET studies in normal subjects.

Adolescent↗

Development of an MR-compatible gamma probe for combined MR/RI guided surgery.

We have developed and tested an MR-compatible gamma probe to simultaneously obtain anatomical information and functional information during surgery. The probe consists of a probe head, an optical fibre bundle and a photo-multiplier tube (PMT). The NaI(T1) scintillator contained in the probe head is connected to a 7 m optical fibre bundle that transfers the scintillation photons produced in the NaI(T1) to an area of low magnetic field or out of the MR-scanner's magnetic shielded room. Although the light loss due to the optical fibre bundle was more than 90%, the photo-peak of the gamma for Co-57 (122 keV) could be observed. The point spread function was 4.5 mm full width at half maximum (FWHM) at 5 mm from the collimator surface for 122 keV gamma photons. Furthermore, there was no sensitivity change outside the MR-scanner, inside the MR-scanner without scanning and inside the MR-scanner with scanning. The probe produced a small artefact on the phantom image of the MR-scanner due to the susceptibility difference of the alloy used for the collimator and the shield. However, the artefact was only limited to area surrounding the probe. These results indicate that the developed MR-compatible gamma probe will make it possible to realize the combined MR/RI guided surgery that provides surgeons with anatomical and RI distribution information simultaneously.

Equipment Design↗

Database of normal human cerebral blood flow, cerebral blood volume, cerebral oxygen extraction fraction and cerebral metabolic rate of oxygen measured by positron emission tomography with 15O-labelled carbon dioxide or water, carbon monoxide and oxygen: a multicentre study in Japan.

Measurement of cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO(2)) by positron emission tomography (PET) with oxygen-15 labelled carbon dioxide (C(15)O(2)) or (15)O-labelled water (H(2)(15)O), (15)O-labelled carbon monoxide (C(15)O) and (15)O-labelled oxygen ((15)O(2)) is useful for diagnosis and treatment planning in cases of cerebrovascular disease. The measured values theoretically depend on various factors, which may differ between PET centres. This study explored the applicability of a database of (15)O-PET by examining between-centre and within-centre variation in values. Eleven PET centres participated in this multicentre study; seven used the steady-state inhalation method, one used build-up inhalation and three used bolus administration of C(15)O(2) (or H(2)(15)O) and (15)O(2). All used C(15)O for measurement of CBV. Subjects comprised 70 healthy volunteers (43 men and 27 women; mean age 51.8+/-15.1 years). Overall mean+/-SD values for cerebral cortical regions were: CBF=44.4+/-6.5 ml 100 ml(-1) min(-1); CBV=3.8+/-0.7 ml 100 ml(-1); OEF=0.44+/-0.06; CMRO(2)=3.3+/-0.5 ml 100 ml(-1) min(-1). Significant between-centre variation was observed in CBV, OEF and CMRO(2) by one-way analysis of variance. However, the overall inter-individual variation in CBF, CBV, OEF and CMRO(2) was acceptably small. Building a database of normal cerebral haemodynamics obtained by the(15)O-PET methods may be practicable.

Blood Volume↗

Optimum threshold setting for a positron-sensitive probe with background rejection capability.

In a positron-sensitive probe composed of a plastic scintillator and a bismuth germanate (BGO), scattered annihilation photons in the plastic scintillator become background counts. Although these scattered annihilation photons can be rejected by higher threshold level settings for the scintillation pulse of the plastic scintillator and for that of the BGO, the system sensitivity is reduced. We have theoretically and experimentally optimized the threshold levels for both the plastic scintillator and the BGO. After calculating the energy loss in the plastic scintillator and the BGO for the scattered annihilation photons, we measured the background counts of a positron-sensitive probe by changing these threshold levels. Results revealed that one optimum threshold setting of the positron-sensitive probe was 0.3 of the peak level of the pulse for the plastic scintillator and 0.7 of that for the BGO. With these threshold levels, the background counts could be decreased to less than 0.2% of the true positron counts.

Algorithms↗

What is the most appropriate scan timing for intraoperative detection of malignancy using 18F-FDG-sensitive gamma probe? Preliminary phantom and preoperative patient study.

PURPOSE: To evaluate the appropriate post-injection timing for hand-held-gamma-ray-detecting probe (GDP) scanning for the intraoperative detection of malignancy after preoperative F-18 FDG (FDG) injection. METHODS: Patient study with superficially located cancer was performed on three patients before operation by dual-phase whole-body PET at 2 and 6-7 hr post-injection of FDG (370 MBq), and by probe scanning from the skin at several points at 1, 3, 5, and 7 hr after FDG injection. TNRa (tumor-adjacent-normal ratio) and TNRc (tumor-contralateral-normal ratio) were calculated. Phantom study was also performed to determine basic GDP function. RESULTS: The patient study revealed that tumors showed constant TNRa (0.9-1.3) and TNRc (1.1-3.0) by GDP count rate, and that there was no tendency of an increase in TNRa with time. The standard deviations of GDP count rate were lower at 1-3 hr post-injection compared with those of delayed scans. While delayed PET showed an increase or no change in the tumor FDG uptake, the decrease of normal tissue FDG uptake was not adequate to create higher TNRs. The phantom study revealed that LN model showed TNRa of 1.7 or greater by GDP count rate (cps) when background contained no FDG, but that they showed TNRa of 1.3 or less when the background contained 4% of the LN FDG activity per ml. CONCLUSION: The present study suggests that higher FDG count rate of tumors at 1-3 hr postinjection would be more suitable for the gamma-probe detection compared with lower count rate at 6-7 hr delayed scans with wide standard deviations.

Adult↗

[Reduction of reconstruction time and data volume of sinogram by angular compression for clinical three-dimensional whole body FDG-PET].

In positron emission tomography (PET), the large number of lines of responses in three-dimensional (3D) acquisition mode creates a high volume of sinogram data and increases reconstruction time in iterative reconstruction. We tried to decrease sinogram data volume by reducing the number of views using angular compression and then evaluated the accuracy of this mashed mode. Three methods were compared, conventional mode (CONV), X2 mashed mode (X2: two adjacent projection angles are added together), and X4 mashed mode (X4: four adjacent angles added). A point source of (18)F was used to measure spatial resolution. A hot spot phantom made of 6 hot spheres (10-38 mm in diameter) within water of 20 cm in diameter was scanned to evaluate the recovery coefficient (RC). A lung-heart-liver phantom made of homogeneous radioactive myocardium, a spherical hot mass in the lung (10 mm in diameter), and background activity in the liver was scanned to evaluate the homogeneity of the myocardial wall. The quality of the reconstructed images was evaluated in terms of the normalized mean square error (NMSE), Bull's eye map, profile curve, and peak value of the spherical hot mass. The reconstruction times of X2 and X4 were one-half and one-quarter, respectively, of that of CONV. In terms of spatial resolution, FWHM of CONV, X2, and X4 were, 4.26, 4.33, and 4.48 (mm) at the center, 4.81, 5.68, and 8.73 tangentially, and 8.01, 8.19, and 8.27 radially at R=200 mm, respectively. RC was similar for all methods. The NMSE values of X2 and X4 compared with CONV were 0.0003 and 0.0014, respectively. In the hot mass, these methods showed almost the same profile curves, although the peak value of X4 was only -1.95% less than that of CONV. Although the result of spatial resolution of X4 was slightly degraded, image quality and physical performance were good. Therefore, the X4 mashed mode used with angular compression was considered clinically useful.

Humans↗

[Evaluation of noise equivalent count per line of response: new parameter for count statistics for PET systems].

OBJECTIVE: The noise equivalent count (NEC) is a useful, widely accepted method of evaluating image quality in positron emission tomography (PET) from the standpoint of effective count statistics. However, NEC cannot be used when different types of PET scanners are compared owing to the differences in slice thickness and field of view. Moreover, NEC should be treated differently depending on whether the 2D or 3D mode is used for a given PET scanner. A new parameter "Specific NEC," which is NEC per line of response (LOR) was devised to compare image quality between different PET scanners and acquisition modes. METHODS: Two PET scanners were employed, the CTI-Siemens ECAT EXACT HR(+) and ECAT EXACT 47. Images of a cylindrical (68)Ge phantom were scanned in 2D and 3D modes using various acquisition times ranging from 15 secx20 frames to 120 secx20 frames in order to examine the effect of count statistics on the quality of image reconstruction. The data were reconstructed using a ramp filter with a cutoff frequency of 0.5 cycles/pixel, corrected for dead time, random, attenuation, and scatter. The quality of the reconstructed images was evaluated with the coefficient of variation (COV; SD/average for the pixels within a 16 cm region of interest). Specific NEC was defined as NEC divided by the number of LOR for the entire scanner at detector level. RESULTS: COV showed a linear relationship with Specific NEC in double logarithmic plot within a given experiment. When the Specific NEC was used, all 2D and 3D mode showed the same relationship. The slight difference between the two scanners was attributed to the difference in slice thickness. CONCLUSION: Image quality was dependent on effective count statistics per number of LOR. Our method was considered effective for evaluating image quality in both 2D and 3D modes.

Artifacts↗