Importance of body sway velocity information in controlling ankle extensor activities during quiet stance.

In literature, it has been suggested that the CNS anticipates spontaneous change in body position during quiet stance and continuously modulates ankle extensor muscle activity to compensate for the change. The purpose of this study was to investigate whether velocity feedback contributes by modulating ankle extensor activities in an anticipatory fashion, facilitating effective control of quiet stance. Both theoretical analysis and experiments were carried out to investigate to what extent velocity feedback contributes to controlling quiet stance. The experiments were carried out with 16 healthy subjects who were asked to stand quietly with their eyes open or closed. During the experiments, the center of pressure (COP) displacement (COPdis), the center of mass (COM) displacement (COMdis), and COM velocity (COMvel) in the anteroposterior direction were measured. Rectified electromyograms (EMGs) were used to measure muscle activity in the right soleus muscle, the medial gastrocnemius muscle, and the lateral gastrocnemius muscle. The simulations were performed using an inverted pendulum model that described the anteroposterior kinematics and dynamics of quiet stance. In the simulations, an assumption was made that the COMdis of the body would be regulated using a proportional-derivative (PD) controller. Two different PD controllers were evaluated in these simulations: 1) a controller with the high-derivative/velocity gain (HDG) and 2) a controller with the low-derivative/velocity gain (LDG). Cross-correlation analysis was applied to investigate the relationships between time series obtained in experiments 1) COMdis and EMGs and 2) COMvel and EMGs. Identical cross-correlation analysis was applied to investigate the relationships between time series obtained in simulations 3) COMdis and ankle torque and 4) COMvel and ankle torque. The results of these analyses showed that the COMdis was positively correlated with all three EMGs and that the EMGs temporally preceded the COMdis. These findings agree with the previously published studies in which it was shown that the lateral gastrocnemius muscle is actively modulated in anticipation of the body's COM position change. The COMvel and all three EMGs were also correlated and the cross-correlation function (CCF) had two peaks: one that was positive and another that was negative. The positive peaks were statistically significant, unlike the negative ones; they were larger than the negative peaks; and their time shifts were much shorter compared with the time shifts of the negative peaks. When these results were compared with the CCF results obtained for simulated time series, it was discovered that the cross-correlation results for the HDG controller closely matched cross-correlation results for the experimental time series. On the other hand, the simulation result obtained for LDG controller did not match the experimental results. These findings suggest that the actual postural control system during quiet stance adopts a control strategy that relies notably on velocity information and that such a controller can modulate muscle activity in anticipatory manner without using a feed-forward mechanism.

Adult↗

Transcutaneous functional electrical stimulator "Compex Motion".

Research groups in the field of functional electrical stimulation (FES) are often confronted with the fact that existing and commercially available FES stimulators do not provide sufficient flexibility and cannot be used to perform different FES tasks. The lack of flexibility of the commercial systems until now forced various FES research teams to develop their own stimulators. This paper presents a newly developed firmware and graphical programming software for the commercial Compex 2 stimulator which enhances the versatility and capabilities of the stimulator from a medical and therapeutic device to a neuroprosthesis and research tool. The new stimulator, called Compex Motion, can now be used to develop various custom-made neuroprostheses, neurological assessment devices, muscle exercise systems, and experimental setups for physiological studies. It can be programmed to generate any arbitrary stimulation sequence that can be controlled or regulated by various external sensors, sensory systems, or laboratory equipment. By interconnecting two or more Compex Motion stimulators, the number of stimulation channels can be increased to multiples of four channels, 8, 12, 16, 20, and so forth. The stimulation sequences and the control strategies are programmed and stored on exchangeable credit card-sized memory chip cards. The stimulator has four biphasic current-regulated stimulation channels and two general purpose analog input channels that can be configured to measure the output voltage of a variety of sensors such as goniometers, inclinometers, gyroscopes, or electromyographic (EMG) sensors. For real-time EMG control of the stimulation patterns, an EMG processing algorithm with software stimulation artifact blanking was implemented. The Compex Motion stimulator is manufactured by the Swiss company Compex SA and is currently undergoing clinical trials.

Electric Stimulation Therapy↗

Neuroprostheses for grasping.

In recent years a number of neuroprostheses have been developed and used to assist stroke and spinal cord injured subjects to restore or improve grasping function. These neuroprostheses clearly demonstrated that the targeted group of subjects can significantly benefit from this technology and that functional electrical stimulation (FES) is a viable method for restoring or improving grasping function. In this article the FES technology is briefly explained and some of the better known neuroprostheses for grasping are discussed. Furthermore, a typical population of subjects that can benefit from this technology is indicated as well as the methodology to select and train these subjects to apply the neuroprosthesis in daily living activities. This article also provides a brief summary of the achieved results with the existing neuroprostheses for grasping and discusses some of the challenges this technology is currently facing.

Artificial Limbs↗