Transcutaneous functional electrical stimulator "Compex Motion".

Abstract

Research groups in the field of functional electrical stimulation (FES) are often confronted with the fact that existing and commercially available FES stimulators do not provide sufficient flexibility and cannot be used to perform different FES tasks. The lack of flexibility of the commercial systems until now forced various FES research teams to develop their own stimulators. This paper presents a newly developed firmware and graphical programming software for the commercial Compex 2 stimulator which enhances the versatility and capabilities of the stimulator from a medical and therapeutic device to a neuroprosthesis and research tool. The new stimulator, called Compex Motion, can now be used to develop various custom-made neuroprostheses, neurological assessment devices, muscle exercise systems, and experimental setups for physiological studies. It can be programmed to generate any arbitrary stimulation sequence that can be controlled or regulated by various external sensors, sensory systems, or laboratory equipment. By interconnecting two or more Compex Motion stimulators, the number of stimulation channels can be increased to multiples of four channels, 8, 12, 16, 20, and so forth. The stimulation sequences and the control strategies are programmed and stored on exchangeable credit card-sized memory chip cards. The stimulator has four biphasic current-regulated stimulation channels and two general purpose analog input channels that can be configured to measure the output voltage of a variety of sensors such as goniometers, inclinometers, gyroscopes, or electromyographic (EMG) sensors. For real-time EMG control of the stimulation patterns, an EMG processing algorithm with software stimulation artifact blanking was implemented. The Compex Motion stimulator is manufactured by the Swiss company Compex SA and is currently undergoing clinical trials.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Thierry Keller, Milos R Popovic, Ion P I Pappas, Pierre-Yves Müller. 2002. Transcutaneous functional electrical stimulator "Compex Motion".. https://doi.org/10.1046/j.1525-1594.2002.06934.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modeling biological motor control for human locomotion with functional electrical stimulation.

This paper develops a novel control system for functional electrical stimulation (FES) locomotion, which aims to generate normal locomotion for paraplegics via FES. It explores the possibility of applying ideas from biology to engineering. The neural control mechanism of the biological motor system, the central pattern generator, has been adopted in the control system design. Some artificial control techniques such as neural network control, fuzzy logic, control and impedance control are incorporated to refine the control performance. Several types of sensory feedback are integrated to endow this control system with an adaptive ability. A musculoskeletal model with 7 segments and 18 muscles is constructed for the simulation study. Satisfactory simulation results are achieved under this FES control system, which indicates a promising technique for the potential application of FES locomotion in future.

Electric Stimulation Therapy↗

Complications and troubleshooting of two-stage sacral neuromodulation therapy: a single-institution experience.

OBJECTIVES: With the increasing use of sacral neuromodulation therapy, urologists are faced with postimplantation challenges. The purpose of this study was to identify these events and their causes and management in our large single-institution experience. METHODS: From July 2002 to September 2004, all patients who underwent sacral neuromodulation therapy for refractory bladder conditions were identified. Their medical records were retrospectively evaluated for history, operative intervention, and programming visits. Events after implantation of the implantable pulse generator (IPG) unit were noted. The evaluation, troubleshooting, management, and resolution of events at the last follow-up visit were extracted. RESULTS: A total of 214 patients underwent sacral neuromodulation therapy at our institution. The mean patient age was 53.5 +/- 15.4 years. Of the 214 patients, 161 underwent IPG implantation during a mean follow-up period of 16 months (range 5 to 30). The second-stage explantation and revision rate was 10.5% and 16.1%, respectively. The indications for explantation were infection (8 of 17) and failure to maintain a response (9 of 17). Revisions were done for decreases in response with abnormal (12 of 26) or normal (5 of 26) impedance measurements, IPG site discomfort (4 of 26), draining sinus at the IPG site (4 of 26), and lead migration (1 of 26). Equalization of impedance measurements was the most commonly observed impedance abnormality. These were managed by drying fluid from the connection in 4 patients and lead change in the rest. CONCLUSIONS: After IPG implantation, a decline in response may occur. Although some were explanted, most were revised, with most of the revisions functional on follow-up. Familiarity with impedance evaluation and development of algorithms for postimplant management are essential for troubleshooting and maintenance of the device.

Electric Stimulation Therapy↗