PubMed Health⌕ Search

Biomedical subjects

N Nicoli Aldini

Publications and source records attributed to N Nicoli Aldini.

At least 19 recordsLinked to original sources

Bioabsorbable scaffold for in situ bone regeneration.

A non-porous poly-DL-lactide tubular chamber filled by demineralised bone matrix (DBM) and bone marrow stromal cells (BMSC) in combination, was evaluated as a scaffold for guided bone regeneration (GBR) in an experimental model using the rabbit radius. The tubular chamber had an internal diameter of 4.7 mm, a wall thickness of 0.4 mm and a length of 18 mm. Autologous BMSC were obtained, under general anaesthesia from rabbit iliac crest and isolated by centrifugation technique. Allogenic DBM was obtained from cortico-cancellous bone of rabbits. In general anaesthesia, a 10-mm defect was bilaterally created in the radii of 10 rabbits. On the right side (experimental side) the defect was bridged with the chamber filled with both BMSC and DBM. On the left side (control side) the defect was treated by positioning DBM and BMSC between the two stumps. At an experimental time of 4 months histology and histomorphometry demonstrated that the presence of a tubular chamber significantly improved bone regrowth in the defect The mean thickness of newly-formed bone inside the chamber was about 56.7+/-3.74% of the normal radial cortex, in comparison with 46.7+/-10.7% when DBM and BMSC without the chamber were placed in the defect, P<0.05). These results confirmed the effectiveness of the chamber as a container for factors promoting bone regeneration.

Absorbable Implants↗

In vivo study on the healing of bone defects treated with bone marrow stromal cells, platelet-rich plasma, and freeze-dried bone allografts, alone and in combination.

The repair of confined trabecular bone defects in rabbits treated by autologous bone marrow stromal cells (BMSC), platelet-rich plasma (PRP), freeze-dried bone allografts (FDBA) alone and in combination (BMSC + PRP; FDBA + BMSC; FDBA + PRP; FDBA + PRP + BMSC) was compared. A critical size defect was created in the distal part of the femurs of 48 adult rabbits. Histology and histomorphometry were used in the evaluation of healing at 2, 4, and 12 weeks after surgery. The healing rate (%) was calculated by measuring the residual bone defect area. Architecture of the newly formed bone was compared with that of bone at the same distal femur area of healthy rabbits. The defect healing rate was higher in PRP + BMSC, FDBA + PRP, FDBA + BMSC, and FDBA + PRP + BMSC treatments, while lower values were achieved with PRP treatment at all experimental times. The highest bone-healing rate at 2 weeks was achieved with FDBA + PRP + BMSC treatment, which resulted significantly different from PRP (p < 0.05) and BMSC (p < 0.05) treatments. At 4 weeks, the bone-healing rate increased except for PRP treatment. Finally, the bone-healing rate of FDBA + PRP, FDBA + BMSC, and FDBA + PRP + BMSC was significantly higher than that of PRP at 12 weeks (p < 0.05). At 12 weeks, significant differences still existed between PRP, BMSC, and FDBA groups and normal bone (p < 0.05). These results showed that the combination of FDBA, BMSC and PRP permitted an acceleration in bone healing and bone remodeling processes.

Animals↗

The healing of confined critical size cancellous defects in the presence of silk fibroin hydrogel.

In vitro and in vivo behaviour of an injectable silk fibroin (SF) hydrogel was studied through osteoblast cultures and after implantation in critical-size defects of rabbit distal femurs. A commercial synthetic poly(D,L lactide-glycolide) copolymer was used as control material. In vitro biocompatibility was evaluated by measuring LDH release, cell proliferation (WST1), differentiation (ALP, OC), and synthetic activity (collagen I, TGF ss1, IL-6). Bone defect healing rate and quality of the newly formed bone inside the defects were determined in vivo by measuring trabecular bone volume (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), trabecular separation (Tb.Sp), mineral apposition rate (MAR) and bone formation rate (BFR/B.Pm). In vitro tests indicated that both materials significantly increased cell proliferation in comparison with the negative control. A significant increase in the TGF-beta1 level was found for SF hydrogel in comparison with the control material and negative control. Both materials promoted bone healing when used to fill critical size defects in rabbit femurs. The new-formed bone of the SF hydrogel treated defects showed significantly higher BV/TV, Tb.Th, MAR and BFR/B.Pm and lower Tb.Sp values in comparison with the control gel. At 12 weeks the re-grown bone of the SF hydrogel-treated defects appeared more similar to normal bone than that of the control synthetic polymeric material-treated defects, except for the Tb.N value that differed significantly from that of normal bone (p<0.05). MAR and BFR/B.Pm presented significantly (p<0.05) higher values for SF hydrogel-treated defects in comparison with controls treated with a synthetic polymeric material, confirming that SF hydrogel accelerated remodelling processes.

Animals↗

Prosthetic devices shaped as tubular chambers for the treatment of large diaphyseal defects by guided bone regeneration.

Guided tissue regeneration is based on the hypothesis that the different tissues have unequal abilities to penetrate a wounded area during the healing process. The use of a device acting as a chamber allows the growth of a particular tissue and prevents the ingrowth of other tissues which impair the healing process. At the same time the chamber protects and maintains in situ the intrinsic growth factors so that they may perform their specific activity. Guided tissue regeneration currently plays a well-recognized role mostly in dentistry and peripheral nerve surgery but interesting perspectives have also opened up in orthopedics. Considering the possibility of using guided bone regeneration in the repair of diaphyseal bone defects, this updated survey highlights some critical points and pathways related to the state-of-the-art of this promising procedure, focusing particularly on the properties of the material to make the tubular chamber, the use of osteopromotive factors and the most appropriate animal model to be used for the experimental evaluation.

Animals↗

Osteointegration of bioactive glass-coated and uncoated zirconia in osteopenic bone: an in vivo experimental study.

In elderly and osteoporotic patients an age-related loss of osteoinductivity could be the biological cause of implant failure regardless of the high quality of the implanted device. yttria stabilized tetragonal zirconia (YSTZ), either coated with the bioactive glass named RKKP bioglaze (RKKP) or uncoated, was implanted in the distal femurs of sham-operated and ovariectomized female rats. Animals were sacrificed at 30 and 60 days. Histomorphometry and microhardness tests were performed to assess osteointegration rate as well as bone quality around the implants. Significant decreases (p < 0.0005) in trabecular bone volume, BV/TV (41%), trabecular bone surface BS/TV (33%), trabecular thickness Tb.Th (20%), and trabecular number Tb.N (32%), together with a significant increase in trabecular separation Tb.Sp (184%), were found for the osteopenic rats compared with the sham-operated rats. At both experimental times the RKKP coating ensured a better osteointegration rate with higher AI values than the uncoated YSTZ, even when osteopenic rats were used (48% at 30 days and 12% at 60 days). No differences were observed at the bone-biomaterial interfaces for either material when comparing sham-operated with osteopenic rats. The present results demonstrate that the RKKP bioactive glass used as a coating ensures a high osteointegration rate even in osteoporotic bone, which is already visible from postoperative day 30 and is still apparent on day 60.

Animals↗

Histomorphometric bone modifications induced by growth hormone treatment in a rabbit model of short bowel syndrome.

The effects of recombinant human growth hormone (rhGH) on cancellous and cortical bone were investigated in an experimental rabbit model of short bowel syndrome (SBS). Eighteen young male New Zealand rabbits, 2.0 +/- 0.2 kg b.w., were divided into three groups: an SBS Group submitted to a 70% midjejunoileal enterectomy and reanastomosis; an SBS-GH Group undergoing the same surgery and receiving 0.4 mg/kg/day rhGH for 28 days; a Control Group which was sham-operated. Thirty-five days after surgery, all the animals were pharmacologically euthanised and their femurs and L5 vertebrae were used for densitometric and histomorphometric studies. Vertebral and femoral densitometric results showed that the SBS Group presented significantly (P<0.01) lower values (10-25%) than the Control and SBS-GH Groups. Significant differences in the cancellous histomorphometric parameters, namely the trabecular bone area (-7% to 46%), trabecular thickness (-21% to 34%) and trabecular separation (17-32%), were observed between the SBS Group and the other groups. Both the SBS and SBS-GH Groups showed significantly (P<0.05) higher values than the Control Group in terms of cross-sectional area (approximately 24%), cortical area (approximately 20%), and periosteal perimeter (approximately 9%), while medullary area (41%) and endocortical perimeter (18%) were significantly higher (P<0.05) in SBS Group than those of Control Group. The current findings are encouraging and suggest that GH administration in SBS animal model used may improve skeletal tissue remodelling.

Animals↗

Poly(2-hydroxyethyl methacrylate) biomimetic coating to improve osseointegration of a PMMA/HA/glass composite implant: in vivo mechanical and histomorphometric assessments.

Bone implants must simultaneously satisfy many requirements, even though the surface properties remain a crucial aspect in osseointegration success. Since a single material with a uniform structure cannot satisfy all of these requirements, composite materials specifically designed for orthopedic or dental implant application should be envisaged. Two poly(methylmethacrylate)/hydroxyapatite composites reinforced by E-glass fibres, uncoated (PMMA/HA/Glass) and poly(2-hydroxyethyl methacrylate) (PMMA/HA/Glass+pHEMA) coated by the biomimetic method, were mechanically (push-out test) and histomorphometrically (Affinity Index, AI) investigated in an in vivo rabbit model. Cylindrical implants (diameter 2 mm x 5 mm length) were inserted into rabbit femoral cortical (mid-diaphysis) and cancellous (distal epiphysis) bone, under general anesthesia. The highest values of push-out force and ultimate shear strength were observed for the PMMA/HA/Glass at 12 weeks, which significantly (p < 0.001) differed from those of PMMA/HA/Glass+pHEMA at the same experimental time and from those of PMMA/HA/Glass at 4 weeks. At both experimental times, significantly (p < 0.0005) lower values of AI were observed in the PMMA/HA/Glass+pHEMA versus PMMA/HA/Glass (distal femoral epiphysis: 4 weeks = 33%; 12 weeks = 19%; femoral diaphysis: 4 weeks = 15%; 12 weeks = 11%). The good mechanical and histomorphometric results obtained with PMMA/HA/Glass should be followed by further evaluation of bone remodeling processes and mechanical strength around loaded PMMA/HA/Glass implants at longer experimental times. Finally, the biomimetic method applied to pHEMA needs to be further investigated in order to improve the positive effect of SBF on pHEMA and to enhance the coating adhesion.

Animals↗

Histomorphometric and microhardness assessments of sheep cortical bone surrounding titanium implants with different surface treatments.

Several factors influence the healing process and the long-term mechanical stability of cementless fixed implants, such as bone remodeling and mineralization processes. Histomorphometric and bone hardness measurements were taken in implants inserted in sheep femoral cortical bone at different times to compare the in vivo osseointegration of titanium screws (diam.; 3.5 x 7 mm length) with the following surface treatments: machined (Ti-MA); acid-etched (Ti-HF); HA vacuum plasma spray (Ti-HA); and Ca-P anodization followed by a hydrothermal treatment (Ti-AM/HA). Ti-MA and Ti-AM/HA implants presented the lowest (Ra = 0.20 +/- 0.01 microm) and highest (Ra = 1.97 +/- 0.64 microm) significant (p < 0.0005) roughness value, respectively. Bone-to-implant contact of Ti-HF was lower than that of the other surface treatments at both experimental times (8 weeks: -20%, ns; 12 weeks: -30%, p < 0.01). Significant differences in MAR (mineral apposition rate) were also found between the different experimental times for Ti-MA (115%, p < 0.01) and Ti-HF (57%, p < 0.01), demonstrating that bone growth had slowed inside the screw threads of Ti-HA and Ti-AM/HA after 12 weeks. No bone microhardness changes in preexisting host bone were found, while Ti-MA showed the lowest value for the inner thread area at 8 weeks (HV(200 microm)= 49.8 +/- 3.8 HV). These findings confirm that osseointegration may be accelerated by adequate surface roughness and bioactive ceramic coating such as Ca-P anodization followed by a hydrothermal treatment, which enhance bone interlocking and mineralization.

Animals↗

Biological assessment of the bone-screw interface after insertion of uncoated and hydroxyapatite-coated pedicular screws in the osteopenic sheep.

The sheep seems to be a promising model of osteoporosis and biomaterial osteointegration in osteopenic bone. The long-term ovariectomized sheep model was used for the biological investigation of bone healing around uncoated and hydroxyapatite (HA)-coated pedicle screws in osteopenic bone. Four sheep were ovariectomized and four sheep were sham-operated. Twenty-four months after surgery, the animals were implanted with uncoated and HA-coated stainless steel screws in the lumbar vertebral pedicles. Four months later, bone-to-implant contact, bone ingrowth, and bone hardness were measured around screws. Uncoated stainless steel presented significantly (p < 0.0005) lower bone-to-implant contact in healthy and osteopenic bone compared with HA-coated stainless steel. HA significantly improved bone ingrowth in healthy bone (p < 0.05) compared with uncoated stainless steel. Osteopenia significantly (p < 0.05) reduced the area of bone ingrowth around the screw threads for both types of implants. In the inner thread area, bone microhardness significantly increased (p < 0.05) in HA-coated surface versus uncoated for healthy and osteopenic bone. HA coating significantly enhances bone-to-implant contact also in osteopenic bone in comparison with uncoated stainless steel surfaces. Bone ingrowth and mineralization are ameliorated by the osteoconductive HA coating. However, osteopenia seems to greatly influence bone ingrowth processes around the implanted screws regardless of the characteristics of the material surface.

Animals↗

X-ray micro-diffraction analysis of reconstructed bone at Zr prosthetic surface with sub-micrometre spatial resolution.

The purpose of the present investigation is to demonstrate the power of the x-ray micro-diffraction technique in biological studies. In particular the reported experiment concerns the study of the interface between a Zr prosthetic device implanted in a rat femur and the newly-formed bone, with a spatial resolution of 0.5 microm. The obtained results give interesting information on the Zr deformation and on the crystallographic phase, the grain size and the orientation of the new bone. Moreover the study reveals a marked difference in the structure of the reconstructed bone with respect to the native bone, which cannot be appreciated with other techniques.

Animals↗

Biomechanical and histomorphometric investigations on two morphologically differing titanium surfaces with and without fluorohydroxyapatite coating: an experimental study in sheep tibiae.

The influence of fluorohydroxyapatite (FHA) coating and surface roughness of Ti6Al4V implants on bone response was investigated. Uncoated and FHA-coated screws with lower (LR and LR+FHA; Ra: 5.7+/-0.2 microm) and higher (HR and HR+FHA; Ra: 21.8+/-0.9 microm) surface roughness, were inserted into the diaphyses of 8 sheep tibiae. Twelve weeks after implantation, extraction torque and bone-to-implant contact were evaluated. The smoothest surfaces showed an improved extraction torque and significant differences were observed between LR and HR (-24.6%, p<0.0005), LR and HR+FHA (-30.7%, p<0.0005), LR+FHA and HR (-17.4%, p<0.005), and LR+FHA and HR+FHA (-24.0%, p<0.005). The bone-to-implant contact data paralleled the biomechanical data: the smoother the surface, the greater the bone-to-implant contact. Significant (p<0.0005) decreases in bone-to-implant contact were observed between LR+FHA and HR (-24.2%), and between LR+FHA and HR+FHA (-29.2%). The current findings suggest that LR surfaces significantly improve the osteointegration rate of implanted cortical screws independently of the FHA coating.

Animals↗

A new austenitic stainless steel with negligible nickel content: an in vitro and in vivo comparative investigation.

New nickel (Ni)-reduced stainless-steel metals have recently been developed to avoid sensitivity to Ni. In the present study, an austenitic Ni-reduced SSt named P558 (P558, Böhler, Milan, Italy) was studied in vitro on primary osteoblasts and in vivo after bone implantation in the sheep tibia, and was compared to ISO 5832-9 SSt (SSt) and Ti6Al4V. Cells were cultured directly on P558 and Ti6Al4V. Cells cultured on polystyrene were used as controls. Osteoblast proliferation, viability and synthetic activity were evaluated at 72 h by assaying WST1, alkaline phosphatase activity (ALP), nitric oxide, pro-collagen I (PICP), osteocalcin (OC), transforming growth factor-beta1 (TGFbeta-1) and interleukin-6 (IL-6) after 1.25(OH)2D3 stimulation. Under general anaesthesia, four sheep were submitted for bilateral tibial implantation of P558, SSt and Ti6Al4V rods. In vitro results demonstrated that the effect of P558 on osteoblast viability, PICP, TGF beta-1, tumor necrosis factor-alpha production did not significantly differ from that exerted by Ti6Al4V and controls. Furthermore, P558 enhanced osteoblast differentiation, as confirmed by ALP and OC levels, and reduced IL-6 production. At 26 weeks, the bone-to-implant contact was higher in P558 than in SSt (28%, p<0.005) and Ti6Al4V (4%, p<0.05), and was higher in Ti6Al4V than in SSt (22%, p<0.005). The tested materials did not affect bone microhardness in pre-existing host bone as evidenced by the measurements taken at 1000 microm from the bone-biomaterial interface (F=1.89, ns). At the bone-biomaterial interface the lowest HV value was found for SSt, whereas no differences in HV were observed between materials (F=1.55, ns). The current findings demonstrate P558 biocompatibility both in vitro and in vivo, and osteointegration processes are shown to be significantly improved by P558 as compared to the other materials tested.

Alloys↗

In vitro behaviour of osteoblasts cultured on orthopaedic biomaterials with different surface roughness, uncoated and fluorohydroxyapatite-coated, relative to the in vivo osteointegration rate.

The effects of two surfaces with different roughness (Low Roughness, LR: Ra: 5.6-5.9 microm; High Roughness, HR: Ra: 21.5-22.5 microm), uncoated and fluorohydroxyapatite(FHA)-coated, were investigated in MG-63 osteoblasts. At 72 hours, cells proliferated on biomaterials more slowly than in the control group (p < 0.0001), the proliferation rate was higher on FHA-coated LR than uncoated HR (p = 0.037). Collagen-I production was positively affected by the LR surface (p = 0.001) as compared to controls, while it was significantly lower (p = 0.0001) in the HR surfaces. Compared to controls, LR and HR surfaces led to enhanced production of TGF-beta1, further improved by FHA (FHA-coated LR: p = 0.007; FHA-coated HR p < 0.0001 respectively). ALP, OC, IL-6 and TNF-alpha levels were not significantly different from the controls. Results suggest that collagen-I production could be useful in predicting the in vivo osteointegration rate of biocompatible biomaterials observed in previous studies.

Alkaline Phosphatase↗

Improvement in zirconia osseointegration by means of a biological glass coating: An in vitro and in vivo investigation.

The biocompatibility and osseointegration of zirconia (ZrO(2)), either coated with RKKP bioglazeor uncoated, were evaluated in vitro and in vivo. The in vitro test was performed in human osteoblasts, whereas maximal sensitization was performed in 23 Dunkin Hurtley guinea pigs. RKKP bioglaze-coated and uncoated (controls) ZrO(2) cylinders were implanted in the distal femoral epiphyses of 14 Sprague-Dawley rats under general anesthesia, and animals were sacrificed at 30 and 60 days. Lactate dehydrogenase, alkaline phosphatase, and Thiazolyl Blue (MTT) were tested in vitro. A graded score was used for evaluating the results of the sensitization test. Histomorphometry and microhardness testing were performed to quantify the osseointegration rate, as well as bone quality around the implants. Neither in vitro cytotoxicity nor sensitization were observed. Histomorphometry demonstrated that at 30 days, the affinity index was significantly higher in coated implants than in uncoated ones (p < 0.05); at 60 days, the behavior of coated implants was better than that of uncoated ones, but differences were not significant. Significant increases in bone microhardness were found at 1000 microm from the interface area for both uncoated (p < 0.0005) and RKKP bioglaze-coated (p < 0.0005) ZrO(2), and also within 200 microm from the interface (p = 0.014) but only for coated ZrO(2.) These results suggest that RKKP bioglaze-coated ZrO(2) permits biocompatible devices with improved osseointegration properties to be manufactured.

Animals↗

Osteointegration of bioactive glass-coated zirconia in healthy bone: an in vivo evaluation.

Osteointegration of yttria stabilised tetragonal zirconia (YSTZ), either coated with bioactive glass named RKKP bioglaze (RKKP) or uncoated, was evaluated in an animal model. RKKP-coated and uncoated (controls) YSTZ cylinders were implanted in the distal femoral epiphyses of 14 Sprague Dawley rats under general anaesthesia. At the experimental times of 30 and 60 days after sacrifice, histomorphometry and SEM microanalysis were performed on methylmethacrylate-embedded undecalcified sections to determine the osteointegration rate. At 30 days, a significantly higher affinity index was demonstrated in vivo by histomorphometric evaluation in RKKP-coated versus uncoated YSTZ implants p < 0.05); at 60 days, the coated implants behaved better than controls (affinity index of + 32%), but the difference observed lay within the statistical uncertainty. SEM analysis demonstrated better bone adhesion to the material in RKKP-coated YSTZ at both 30 and 60 days. These findings suggest that YSTZ coated with the bioactive glass named RKKP enhances osteointegration of ceramics.

Adsorption↗

Pedicular fixation in the osteoporotic spine: a pilot in vivo study on long-term ovariectomized sheep.

Spinal instrumentation success is greatly affected by the presence of osteoporosis. To date, however, no data exist on in vivo investigations on biomaterial and surgical techniques in the osteoporotic spine. In the present study 24 uncoated and 24 HA-coated screws were implanted in the L3, L4 and L5 pedicles of eight sheep (four ovariectomized, OVX Group; four sham-operated, Control Group). At four months, uncoated screws showed a significant decrease of about -22% in the extraction torque of the OVX Group as compared to the Control Group (p < 0.005). The extraction torque of HA-coated screws significantly (p < 0.0005) improved in both groups when compared to that of uncoated screws and showed increases ranging from 133% to 157%. Pedicle trabecular bone of OVX sheep showed a significant decrease in BV/TV (-30%; p < 0.05) and Tb.Th (-33%; p < 0.01). The affinity index (AI) results revealed significant (p < 0.0005) differences between uncoated and HA-coated screws for both groups: values were lower for uncoated than HA-coated screws by about -35%. A significant difference was also found for the AI data of uncoated screws between the OVX and Control Groups (-13%, p < 0.005). The current findings have demonstrated that long-term ovariectomized sheep can be used to study in vivo osteointegration in the osteoporotic spine. The HA coating has proven to improve bone purchase and bone-screw interface strength in healthy and osteopenic animals.

Animals↗

Tibial implants: biomechanical and histomorphometric studies of hydroxyapatite-coated and uncoated stainless steel and titanium screws in long-term ovariectomized sheep.

This study was designed to evaluate osteointegration of HA-coated and uncoated titanium and stainless steel screws in the cortical bone of long-term (24 months) ovariectomized sheep (OVX group), in comparison with Sham-aged sheep (control group). The screws were tested biomechanically (extraction torque) and histomorphometrically (affinity index: Al) 12 weeks after their implantation in tibial diaphyses. Tibial cortical bone parameters showed significant differences between the groups, showing a reduction of the selected parameters in the OVX group. ANOVA showed significant effects for both material and ovariectomy factors on obtained extraction torque (material: F=159.26, p < 0.0005; ovariectomy: F=20.04, p < 0.0005) and Al data (material: F=8.04, p < 0.001; ovariectomy: F=7, 17, p < 0.05). In both groups the extraction torque for coated screws of both materials was significantly higher than for uncoated screws, and uncoated titanium had a better extraction torque than uncoated stainless steel. In the OVX group, the HA-coated stainless steel and titanium Al data were significantly higher than uncoated Al data. In conclusion, the biomechanical and histomorphological results obtained suggest employing HA-coated screws in the presence of osteopenic cortical bone.

Animals↗

Laser technology in orthopedics: preliminary study on low power laser therapy to improve the bone-biomaterial interface.

Low Power Laser (LPL) seems to enhance the healing of bone defects and fractures. The effect of LPL in other orthopedic areas such as osteointegration of implanted prosthetic bone devices is still unclear. In the present study, 12 rabbits were used to evaluate whether Ga-Al-As (780 nm) LPL stimulation has positive effects on osteointegration. Hydroxyapatite (HA) cylindrical nails were drilled into both distal femurs of rabbits. From postoperative day 1 and for 5 consecutive days, the left femura of all rabbits were given LPL treatment (Laser Group-LG) with the following parameters: 300 Joule/cm2, 1 Watt, 300 Hertz, pulsating emission, 10 minutes. The right femura were sham-treated (Control Group-CG). At 4 and 8 weeks after implantation, histologic and histomorphometric investigations evaluated bone-biomaterial-contact. Histomorphometry showed a higher degree of osteointegration at the HA-bone interface in the LG Group at 4 (p < 0.0005) and 8 weeks (p < 0.001). These preliminary positive results seem to support the hypothesis that LPL treatment can be considered a good tool to enhance the bone-implant interface in orthopedic surgery.

Animals↗