PubMed Health⌕ Search

Biomedical subjects

N Olson

Publications and source records attributed to N Olson.

At least 19 recordsLinked to original sources

Effects of the cowpea chlorotic mottle bromovirus beta-hexamer structure on virion assembly.

The X-ray crystal structure of Cowpea chlorotic mottle bromovirus (CCMV) revealed a unique tubular structure formed by the interaction of the N-termini from six coat protein subunits at each three-fold axis of the assembled virion. This structure, termed the beta-hexamer, consists of six short beta-strands. The beta-hexamer was postulated to play a critical role in the assembly and stability of the virion by stabilizing hexameric capsomers. Mutational analyses of the beta-hexamer structure, utilizing both in vitro and in vivo assembly assays, demonstrate that this structure is not required for virion formation devoid of nucleic acids in vitro or for RNA-containing virions in vivo. However, the beta-hexamer structure does contribute to virion stability in vitro and modulates disease expression in vivo. These results support a model for CCMV assembly through pentamer intermediates.

Base Sequence↗

Surface chemical characterization of 2.5-microm particulates (PM2.5) from air pollution in Salt Lake City using TOF-SIMS, XPS, and FTIR.

Particulate matter with a diameter of 2.5 microm collected in Salt Lake City (SLC PM2.5) was studied using TOF-SIMS (time-of-flight secondary-ion mass spectrometry), XPS (X-ray photoelectron spectroscopy), and FTIR (Fourier transform infrared spectroscopy). The high spatial resolution and high surface sensitivity of TOF-SIMS allow the surfaces of individual particulates to be analyzed. The high mass-resolution of TOF-SIMS provides good separation of signals from different chemical species at the same nominal mass, and the extremely high detection sensitivity of TOF-SIMS makes the detection of trace elements possible. Metallic elements such as Li, Na, Mg, Al, K, Ca, Cr, Mn, Fe, Cu, Zn, Cs, and Bi were detected by TOF-SIMS on the surface of SLC PM25. The uranium ion U+ together with its oxide ions UO+ and UO2+ were also found. Inorganic compounds detected include oxides, hydroxides, nitrates, sulfates, silicates, borates, chlorides, etc. Organic compounds detected include hydrocarbons, alcohols, aldehydes, ethers, carboxylic acids, amines, amides, nitriles, etc. A number of polycyclic aromatic hydrocarbons (PAH) and nitrated polycyclic aromatic hydrocarbons were detected by TOF-SIMS. High-resolution XPS Cls spectrum shows functional groups such as C-O, CO2, C-CO2, C-C, and C-H and aromatic pi-pi* shake-up transitions. High-resolution XPS O 1s spectrum indicates the coexistence of different oxygen compounds on the surface of PM2.5. FTIR results confirm the presence of various organic compounds in SLC PM2.5 detected by TOF-SIMS and XPS.

Air Pollutants↗

Analysis and occurrence of polybrominated diphenyl ethers in Washington state freshwater fish.

A method is described for analyzing polybrominated diphenyl ethers (PBDEs) in fish tissue using gas chromatography with atomic emission detection (GC/AED) and quantitation by compound independent calibration (CIC). The method has the advantage of an element-selective response, including selectivity between bromine and chlorine. An analysis of fish tissue samples from selected locations in Washington State showed total PBDE concentrations ranged from 1.4 microg/kg (wet weight) in rainbow trout from a remote spring-fed stream to 1,250 microg/kg in mountain whitefish from the urbanized Spokane River. Tetra and penta isomers were the major compounds present. There appear to be substantial between-species differences in the ability of fish to metabolize PBDEs.

Animals↗

Pictures into words. Visual models and data in psychoanalysis.

The psychoanalytic method is considered as an instrument or medium of observation, with attention to certain peculiarities of data collection and recording. Freud's visual models and metaphors are then reviewed. Subsequent approaches to visual data in analysis are examined in the work of Charles Fisher, Mark Kanzer, Bertram Lewin, and M. Robert Gardner. A corresponding theory of therapeutic action is suggested.

Art↗

Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning.

BACKGROUND: The soiling levels of patient-used narrow-lumened flexible endoscopes were assessed for bronchoscopes, duodenoscopes, and colonoscopes. The effect of cleaning on the soil composition and concentration was evaluated. DESIGN: Suction channels from 10 each of bronchoscopes, duodenoscopes used for endoscopic retrograde cholangiopancreatography, and colonoscopes were assessed immediately after patient use for the levels of bilirubin, hemoglobin, protein, sodium ion, carbohydrate, endotoxin, and viable bacteria. Another 10 suction channels of each type of endoscope were evaluated for the same components after routine cleaning but before processing by high-level disinfection or sterilization for subsequent clinical use. RESULTS: Recognizing that only soluble components could be quantified, the worst-case soil levels in the suction channels (the average surface area of these channels was 45.6 cm(2), 149.8 cm,(2) and 192.0 cm(2) for bronchoscopes, duodenoscopes, and colonoscopes, respectively) were protein 115 microg/cm(2), sodium ion 7.4 micromol/cm(2), hemoglobin 85 microg/cm(2), bilirubin 299 nmol/cm(2), carbohydrate 29.1 microg/cm(2), endotoxin 9852 endotoxin units/cm(2), and bacteria 7.1 (log(10)) colony-forming units (CFU)/cm(2). Colonoscopes had 4 to 5 times greater soiling on average compared with the other endoscope types. Routine cleaning reduced the levels of bilirubin to below the limits of detection for all endoscopes evaluated (limits of detection were <1 nmol/mL). After cleaning, residual hemoglobin was detectable in bronchoscopes only. After cleaning, the levels of protein, endotoxin, and sodium ion all were reduced fivefold to tenfold for all types of endoscopes. Carbohydrate was reduced to lower than the limit of detection for all endoscopes after cleaning, except the duodenoscopes. The average load of viable bacteria was reduced from 3 log(10) to 5 log(10) CFU/cm(2) (which represents 5.9-9.5 log(10) CFU/endoscope channel) after patient use to approximately 2 log(10) CFU/cm(2) (which represents 3.2-5.3 log(10) CFU/endoscope channel) after cleaning. CONCLUSIONS: These data demonstrated that cleaning effectively reduced or eliminated many components of soil, but a substantial amount of viable bacteria and protein remained. Hemoglobin levels in before samples indicated that blood was not present in high concentrations in the suction channels of the majority of flexible endoscope samples. Soil that mimics the worst-case composition from patient-used endoscopes would be ideal for simulated-use studies for such medical devices.

Bronchoscopes↗

Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens.

The aim of this study was to determine how well peracetic acid liquid chemical sterilization (LCPAS) killed test organisms in the presence of 10% fetal bovine serum and 0.65% salt challenge (RPMI-S) compared with a 100% ethylene oxide (ETO) sterilizer and an ETO hydrochlorofluorocarbon (ETO-HCFC) sterilization method with long (125 cm), narrow (3-mm internal diameter) flexible lumens as the test carrier. The inoculated lumens were dried overnight before processing. The test organisms included Mycobacterium chelonei, Enterococcus faecalis, and Bacillus subtilis. For all 3 organisms tested, the LCPAS process resulted in a 6 log10 reduction in bacterial load compared with a 2.5 log10 to 6 log10 reduction for the 100% ETO and ETO-HCFC sterilizers. Sterilization was achieved for 100%, 61%, and 67% of the lumen test carriers for the LCPAS, 100% ETO, and ETO-HCFC sterilizers, respectively. The data indicate that of the sterilization methods evaluated, LCPAS was the most effective for sterilizing narrow flexible lumens in the presence of residual inorganic and organic soil. This effectiveness was achieved through a combination of organism wash-off and peracetic acid sterilant killing of organisms. Salt was the major compounding factor for effective ETO gas sterilization, because carriers inoculated with organisms in 10% fetal bovine serum alone all were sterilized by both 100% ETO and ETO-HCFC sterilization methods. Our data support the critical need to ensure adequate precleaning of narrow flexible lumen endoscopes before any sterilization method.

Bacillus subtilis↗

Cubism, Freud, and the image of wit.

This essay contributes to the psychoanalytic understanding of creativity by applying Freud's theories of jokes and dreams to the interpretation of Cubist-paintings and collages of 1907-14. The selection of Cubism is justified on the basis of various questions which Freud and the Cubists asked in common, questions concerning reality, both external and psychic; the processes of representation and interpretation; the correspondences between the arts and other mental products, such as language and dreams; and the nature of the child and of the so-called primitive mind. Moreover, certain innovative features of Cubism--the incorporation of words, texts, and jokes into painting, and the use of collage--lend themselves to, perhaps even require, exegesis in Freudian terms.

Art↗

Bacterial killing ability of 10% ethylene oxide plus 90% hydrochlorofluorocarbon sterilizing gas.

OBJECTIVES: To use a serum and salt challenge in narrow-lumen carriers to evaluate a 10% ethylene oxide plus 90% hydrochlorofluorocarbon (EO-HCFC) sterilant mixture in a retrofitted 12/88 sterilizer as an alternative to the banned chlorofluorocarbon-ethylene oxide (EO) sterilant mixture. DESIGN: An EO-HCFC sterilizing gas mixture in a retrofitted 12/88 sterilizer was compared to 100% ethylene oxide (100% EO) sterilizing gas to determine its relative ability to kill seven different bacteria (Escherichia coli, Pseudomonas aeruginosa, Enterococcus faecalis, Bacillus subtilis spores, Bacillus stearothermophilus spores, Bacillus circulans spores, and Mycobacterium chelonei) in the presence or absence of a combined 10% serum and 0.65% salt challenge using both penicylinders (PC) and long narrow-lumen (LU) carriers. RESULTS: The EO-HCFC sterilant mixture (96% sterile carriers) was equivalent to the 100% EO sterilant (98% sterile carriers) for killing vegetative organisms, as well as spore suspensions, on the 27 PC and 27 LU carriers in the absence of serum and salt. In the presence of serum and salt, the EO-HCFC sterilant mixture was markedly better than the 100% EO sterilant at reducing the bacterial load on the 63 PC carriers (95% vs 62% sterile PC carriers, respectively), whereas both sterilizers were equivalent for the 63 LU carriers (49% vs 40% sterile LU carriers, respectively). Of the seven test organisms, E faecalis, B subtilis, B stearothermophilus, and B circulans were the most difficult to kill for both PC and LU carriers when serum and salt were present. CONCLUSIONS: The data presented in this report indicate that the EO-HCFC sterilant mixture is an effective alternative for gas sterilization. Indeed, the efficiency of bacterial killing for the EO-HCFC sterilant mixture was similar to that achieved by the 12/88 EO-CFC sterilant mixture.

Bacteria↗

Improved detection of bacterial growth in continuous ambulatory peritoneal dialysis effluent by use of BacT/Alert FAN bottles.

Culture-negative peritonitis is a major complication for patients on continuous ambulatory peritoneal dialysis (CAPD) and precludes organism-specific therapy. The aim of the present study was to compare inoculation of 10 ml of CAPD effluent into BacT/Alert blood culture bottles (FAN [fastidious antimicrobic neutralizing], BacTAlert aerobic [BTA], and BacT/Alert anaerobic [BTAn] bottles) to our conventional method of using 50 ml of concentrated CAPD effluent to inoculate peptone broth bottles (BD bottles) and MacConkey agar and blood agar medium (BA-MAC). The FAN, BTA, and BTAn bottles were monitored automatically in the BacT/Alert blood culture instrument. A total of 207 CAPD effluents were studied, and in 97 bacteria were detected by at least one method. Compared to BTA bottles (79 of 97; 81.4%), BTAn bottles (78 of 97; 80.4%), and BD bottles (88 of 97; 90.7%), the single best broth medium for detecting bacterial growth in CAPD effluents was the FAN bottle (90 of 97 effluents; 92.8%). A total of 125 bacterial species were detected by any method, and the majority (91.8%) of CAPD effluents were infected with a single species. A combination of FAN and BTAn bottles detected 111 of 125 (88.8%) of all organisms, whereas a combination of BD bottles and BA-MAC detected 107 of 125 (85.6%) of all organisms. One or more organisms that would have been completely missed by the conventional method with BD bottles and BA-MAC were detected in 18 CAPD effluents. Of these 18 CAPD effluents, 6 showed no growth by the conventional method with BD bottles and BA-MAC. On the basis of our data, the most sensitive and least labor intensive method was direct inoculation of 10 ml of CAPD effluent into a FAN bottle and a BTAn bottle, which could be automatically monitored by the BacT/Alert blood culture instrument. On the basis of case definitions for peritonitis, the sensitivities and specificities of the methods with FAN and BTAn bottles and with BD bottles and BA-MAC were 81.1 and 98.8% and 74.5 and 96.5%, respectively.

Bacteria↗

Standardized problem list generation, utilizing the Mayo canonical vocabulary embedded within the Unified Medical Language System.

UNLABELLED: VOCABULARY: The Mayo problem list vocabulary is a clinically derived lexicon created from the entries made to the Mayo Clinic's Master Sheet Index and the problem list entries made to the Impression/ Report/Plan section of the Clinical Notes System over the last three years. The vocabulary was reduced by eliminating repetition including lexical variants, spelling errors, and qualifiers (Administrative or Operational terms). Qualifiers are re-coordinated with other terms, at run-time, which greatly increased the number of input strings which our system is capable of recognizing. IMPLEMENTATION: The Problem Manager is implemented using standard windows tools in a Windows NT environment. The interface is designed using Object Pascal. HTTP calls are passed over the World Wide Web to a UNIX based vocabulary server. The server returns a document, which is read into Object Pascal structures, parsed, filtered and displayed. STUDY: This paper reports the results of a recent Usability Trial focused on assessing the viability of this mechanism for standardized problem entry. Eight clinicians engaged in eleven scenarios and responded as to their satisfaction with the systems performance. These responses were observed, videotaped and tabulated. Clinicians in this study were able to find acceptable diagnoses in 91.1% of the scenarios. The response time was acceptable in 92.5% of the scenarios. The presentation of related terms was stated to be useful in at least one scenario by seven of the eight participants. All clinicians wanted to make use of shortcuts which would minimize the amount of typing necessary to encode the concept they were searching for (e.g. Abbreviations, Word Completion). CONCLUSIONS: Clinicians are willing to choose a canonical term from a suggested list (as opposed to their own wording). Clinicians want an "intelligent" system, which would suggest terms within a category (e.g. Types of "Migraine"). They are able to make functional use of our system, in its current state of development. Finally, all clinicians appreciate the value of encoding their problems in a standardized vocabulary, toward improved research, education and practice.

Computer Communication Networks↗

Comparison of ion plasma, vaporized hydrogen peroxide, and 100% ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer.

OBJECTIVE: The performance of a standard gas sterilizer, which uses a mixture of 12% ethylene oxide (EtO) and 88% chlorofluorocarbon as the sterilizing gas (12/88), was compared to selected gas, ion plasma, and vaporized hydrogen peroxide (H2O2) sterilizers that do not use chlorofluorocarbons. The effect of serum and salt on sterilizer performance was evaluated. DESIGN: Test carriers (porcelain and stainless steel penicylinders, or 125-cm lengths of plastic tubing [internal diameter of 3.2 mm]) were inoculated with Escherichia coli, Enterococcus faecalis, Pseudomonas aeruginosa, Mycobacterium chelonei, Bacillus stearothermophilus spores, Bacillus subtilis spores, and Bacillus circulans spores and then subjected to sterilization using 12/88, 100% EtO, ion plasma, or vaporized H2O2. The bacterial inoculum was prepared with and without 10% serum and 0.65% salt, and the residual bacterial load after sterilization as determined using viable counts. RESULTS: All of the sterilizers tested effected a six-log10 reduction of the bacterial inoculum on penicylinders, unless 10% serum and 0.65% salt were present, in which case the 100% EtO, vaporized H2O2, and ion plasma sterilizers were not as effective as the 12/88 sterilizer. None of the sterilizers could eradicate 10(6) CFU of all of the bacteria in 10% serum and 0.65% salt when inoculated inside a narrow lumen. CONCLUSIONS: The margin of safety for the 100% EtO, vaporized H2O2, and ion plasma sterilizers is less than that of the 12/88 sterilizer. The inability of all sterilizers, including the 12/88, to kill organisms in narrow lumens reliably when serum and salt were present raises concern about the current practice of gas sterilization of flexible endoscopes.

Analysis of Variance↗

Transmission of Ureaplasma urealyticum from mothers to full and preterm infants.

This study assessed maternal genital colonization and subsequent neonatal transmission rate of Ureaplasma urealyticum in pregnant women in an average socioeconomic population. In addition very low birth weight infants were assessed to determine whether the presence of U. urealyticum correlated with increased risk of developing respiratory problems. The study group consisted of 108 sequential full term mothers and 104 preterm mothers delivering in a tertiary care hospital in central Canada. The genital carriage rates (assessed using placental sampling) of ureaplasmas in term and preterm mothers were 25.9 and 19.2%, respectively (P = 0.3185). Acquisition of ureaplasmas in the neonatal respiratory tract of neonates occurred significantly (P = 0.0182) more often in preterm neonates (11 of 130; 8.5%) than in term neonates (2 of 110; 0.9%). Very low birth weight (VLBW) infants (< or = 1500 g) were at greater risk (P = 0.042) of acquiring ureaplasmas in their respiratory tracts (5 of 26; 19%) than larger preterm neonates (6 of 104; 5.8%). All VLBW infants with respiratory colonization by ureaplasmas (5 of 5) developed bronchopulmonary dysplasia compared with 33% (7 of 21) of VLBW neonates without ureaplasmas (P = 0.028). This difference in bronchopulmonary dysplasia development among VLBW infants was independent of further stratification by birth weight. These VLBW neonates with ureaplasmas also stayed significantly (P = 0.037) longer in the neonatal intensive care unit (43.6 +/- 10.4 days) than did other preterm neonates (22.1 +/- 20.8 days). Our results demonstrate that VLBW preterm neonates have increased risk of acquiring U. urealyticum.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Serologic testing for reactive arthritis.

The objective of the study was to determine the sensitivity and specificity of quantitative serum antibody response to Salmonella enteritidis lipopolysaccharide (LPS) as a diagnostic test for post-Salmonella reactive arthritis (ReA). In a single food-source outbreak of Salmonella enteritidis, serum was collected from dysenteric individuals with and without ReA at 6, 12, and 24 months post infection. Serum was also collected from control patients with no prior exposure to Salmonella infection. Quantitative measurements of isotypic antibodies to Salmonella enteritidis LPS were performed by an ELISA. Sensitivity and specificity of quantitative isotypic antibody levels over time were plotted on receiver operator characteristic (ROC) curves. Serum IgG and IgA anti-LPS were found to be present in higher levels in the ReA patients than in controls. Using the optimal cutoff of 0.10 selected from an ROC curve, IgG anti-LPS is 88% sensitive and 94% specific, and IgA anti-LPS is 75% sensitive and 100% specific. We conclude that IgA anti-LPS is both sensitive and specific in distinguishing prior exposure to Salmonella LPS in ReA patients compared to unexposed controls.

Antibodies, Bacterial↗

Secretory immune response and clinical sequelae of Salmonella infection in a point source cohort.

OBJECTIVE: To determine the kinetic isotypic serum and secretory immune response to Salmonella enteritidis in a cohort of individuals exposed to the organism in a single food source outbreak of dysentery. To determine the clinical outcome and immunogenetics of the exposed cohort and to correlate these features with the immune response. METHODS: Following a single point source outbreak of Salmonella enteritidis, a cohort of dysenteric individuals were ascertained using a reactive arthritis screening questionnaire (QUEST). Serum and stimulated saliva samples were obtained at 6, 12, and 24 months following the outbreak of dysentery; examinations were conducted at the same time. Two unexposed control groups were ascertained: (1) general rheumatology clinic patients and (2) well nonarthritic family practice patients. An ELISA to determine quantitative IgA responses to Salmonella enteritidis lipopolysaccharide (LPS) was performed. RESULTS: Eleven of the 84 exposed individuals with dysentery developed reactive arthritis (ReA) of reactive enthesitis (ReE). There was a prolonged salivary IgA anti-LPS response in both the ReA/ReE and DYS (dysentery alone) patients compared with unexposed controls. A ratio of salivary IgA anti-LPS/serum IgA anti-LPS > 1 was associated with a good outcome (remission) of ReA, whereas a ratio < 1 was associated with chronic disease. CONCLUSIONS: There is a more prolonged humoral immune response to Salmonella LPS in exposed individuals than hitherto described. A risk factor in the prolongation of ReA is the inability to mount an appropriate specific salivary (secretory) immune response.

Adolescent↗

Analysis of risk factors associated with prostate cancer extension to the surgical margin and pelvic node metastasis at radical prostatectomy.

We analyzed data from 107 consecutive patients with clinical stage B prostate cancer in an attempt to identify those at high risk for having involved margins or nodal metastasis. Each patient underwent transrectal ultrasound-guided sextant biopsies of the prostate. Patient age, surgical approach to prostatectomy, pre-biopsy prostate specific antigen (PSA) level, and number, location and maximum Gleason score of positive biopsies were statistically evaluated for all patients groups. Prostate volume and PSA density (PSAD) were calculated for all patients undergoing prostatectomy. Of the 101 patients who underwent radical prostatectomy 64 had negative margins, 37 had at least 1 positive margin and 11 of the 37 had more than 1 positive margin. Involved margins were most common at the apex (62%) and mid portion (59%) of the gland. Prostatectomy was not performed on 6 patients with nodal metastases evident on frozen section examination. Therefore, 43 patients are considered to be at high risk for having residual disease after surgery. The mean PSAD, PSA level and number of positive biopsies were significant (p < 0.05) predictors of tumor extension to the surgical margin. The mean number of positive biopsies, biopsy Gleason score and PSA level were significantly greater (p < 0.05) in patients with nodal metastases. Only 15% of the patients with a single positive biopsy had positive margins versus 47% of those with multiple positive biopsies (p < 0.05). Of the patients with tumor positive nodes on frozen section 67% had 5 or more positive biopsies, whereas only 9% of all others had that many positive biopsies (p < 0.05). The number of positive biopsy sites, PSAD and PSA level were significantly associated with tumor at the surgical margin or metastatic to the pelvic nodes.

Adenocarcinoma↗

Humoral immune response of humans to lipooligosaccharide and outer membrane proteins of Haemophilus ducreyi.

The humoral immune response to purified lipooligosaccharide (LOS) and outer membrane proteins (OMP) of Haemophilus ducreyi was evaluated. Sera from chancroid-endemic (Uganda, Kenya) and -nonendemic (Canada) countries were tested by an ELISA. The response to OMPs was cross-reactive with other Haemophilus species, and elevated levels of antibody were detected in patients that did not have chancroid. The LOS component stimulated an H. ducreyi-specific immune response that was detected only in patients with chancroid. The sensitivity of the LOS ELISA was 96% (95% confidence interval, 89.9%-100%) and the specificity was 97% (95% confidence interval, 95.8%-98.2%). Thus, the anti-H. ducreyi LOS immune response is a significant diagnostic and epidemiologic indicator.

Adolescent↗

Regulation of the phage phi 29 prohead shape and size by the portal vertex.

Bacteriophage phi 29 of Bacillus subtilis packages its double-stranded DNA into a preformed prohead during morphogenesis. The prohead is composed of the scaffold protein gp7, the capsid protein pg8, the portal protein gp10, and the dispensable head fiber protein gp8.5. Our objective was to elucidate the phi 29 prohead assembly pathway and to define the factors that determine prohead shape and size. The structural genes of the phi 29 prohead were cloned and expressed in Escherichia coli individually or in combination to study form determination. The scaffold protein was purified from E. coli as a soluble monomer. In vivo and in vitro studies showed that the scaffolding protein interacted with both the portal vertex and capsid proteins. When the scaffold protein interacted only with the capsid protein in vivo, particles were formed with variable size and shape. However, in the presence of the portal vertex protein, particles with uniform size and shape were produced in vivo. SDS-PAGE analysis showed that the latter particles contained the proteins of the scaffold, capsid, head fiber, and portal vertex. These results suggest that the scaffolding protein serves as the linkage between the portal vertex and the capsid proteins, and that the portal vertex plays a crucial role in regulating the size and shape of the prohead.

Bacillus subtilis↗

Endoscopic and videofluoroscopic evaluations of swallowing and aspiration.

A new procedure for evaluating oropharyngeal dysphagia utilizing fiberoptic laryngoscopy was compared to the videofluoroscopy procedure. Twenty-one subjects were given both examinations within a 48-hour period. Results of the fiberoptic endoscopic evaluation of swallowing (FEES) and videofluoroscopy examinations were compared for presence or absence of abnormal events. Good agreement was found, especially for the finding of aspiration (90% agreement). The FEES was then measured against the videofluoroscopy study for sensitivity, specificity, positive predictive value, and negative predictive value. Sensitivity was 0.88 or greater for three of the four parameters measured. Specificity was lower overall, but was still 0.92 for detection of aspiration. It was concluded that the FEES is a valid and valuable tool for evaluating oropharyngeal dysphagia. Some specific patients and conditions that lend themselves to this procedure are discussed.

Adult↗