Publications and source records attributed to N Pelc.

12 recordsLinked to original sources

Renal blood flow: measurement in vivo with rapid spiral MR imaging.

PURPOSE: To assess the ability of three cine phase-contrast magnetic resonance (MR) imaging techniques to measure normal human renal blood flow (RBF) in vivo. MATERIALS AND METHODS: Eighteen healthy volunteers were studied with three cine phase-contrast MR imaging techniques: breath-hold, segmented k-space, two-dimensional, Fourier transform technique (ie, time-resolved imaging with automatic data segmentation, or TRIADS); a breath-hold rapid spiral acquisition; and a non-breath-hold rapid spiral acquisition that allowed resolution of both cardiac and respiratory cycles. In each case, total arterial RBF and blood flow per unit of renal volume were calculated. For each subject, RBF was measured with a standard technique of p-aminohippuric acid (PAH)-clearance hematocrit on the same day as the MR imaging examination was performed. RESULTS: The range of agreement (2 standard deviations, or 95% confidence interval) between RBF measurements obtained with the PAH-clearance hematocrit technique and the various cine phase-contrast techniques varied from +/- 17.6% to +/- 26.5%. The best agreement was obtained with non-breath-hold rapid spiral data, by using data from the end-expiratory phase of respiration. CONCLUSION: Findings with cine phase-contrast MR imaging employing rapid spiral acquisition are in good agreement with measurements made with PAH-clearance hematocrit and give the promise of clinical measurements of RBF.

Adult↗

Determination of blood flow to the transplanted kidney. A novel application of phase-contrast, cine magnetic resonance imaging.

There is at present no noninvasive method that reliably measures blood flow in the poorly functioning renal allograft. The present study was designed to evaluate phase-contrast cine magnetic resonance imaging (PC-cine-MRI) for this purpose. We recruited for study 18 patients who had received kidney transplants 13-66 months earlier from closely related living donors. As judged by the glomerular filtration rate, which was elevated for a single kidney (76 +/- 4 ml/min 1.73 m2), allograft function was excellent, permitting the assumption of unimpaired renal extraction of paminohippuric acid (PAH). Allograft blood flow was determined consecutively on the same day, first by the standard PAH clearance technique and they by the product of the velocity of protons and renal vein cross-sectional area using PC-cine-MRI. MRI determinations could not be completed because of claustrophobia in two patients and failure to image the terminus of the allograft vein another two. Comparison of blood flow in the remaining 14 subjects revealed the two techniques to be strongly related (r = 0.91, P < 0.001). On the average, the renal blood flow rate was similar by each method; 732 +/- 62 by PAH clearance and 703 +/- 69 ml/min by PC-cine-MRI, but the agreement among individuals between the two methods was only modest, with a 95% confidence interval of agreement from -214 to +254 ml/min. We conclude that PC-cine-MRI provides a fairly accurate and noninvasive method for determining the rate of blood flow in the transplanted kidney. With further refinement it should permit the role of depressed blood flow in a variety of acute and chronic forms of human allograft dysfunction to be elucidated in humans for the first time.

Glomerular Filtration Rate↗

Normal renal blood flow measurement using phase-contrast cine magnetic resonance imaging.

RATIONALE AND OBJECTIVES: This study assesses the ability of a cardiac-gated phase-contrast magnetic resonance imaging (MRI) technique to measure renal blood flow (RBF) noninvasively in humans. METHODS: In nine normal volunteers, total RBF in the renal arteries and in the left renal vein was estimated by MRI and correlated with RBF determined by the clearance of para-aminohippuric acid (CPAH) and the hematocrit level. RESULTS: Correlation of RBF estimated from left renal vein flow, with RBF by CPAH-hematocrit, yielded r = .86 (P less than .003). Repeated measurement of RBF by MRI demonstrated a high degree of reproducibility, with coefficients of variation ranging from 4.8% to 8.9%. However, the MRI measurements of arterial flow did not significantly correlate with the standard measurements. CONCLUSIONS: Reproducible noninvasive measurement of normal RBF is possible with the phase-contrast MRI technique used to measure renal venous blood flow.

Adult↗

Valvular regurgitation: dynamic MR imaging.

Cine magnetic resonance (MR) imaging is a new technique that combines short repetition times, limited flip angles, gradient refocused echoes, and cardiac gating. This technique has a temporal resolution of up to 32 time frames per cardiac cycle and accentuates signal from flowing blood. Cine MR images of 56 valves in 27 patients were evaluated and compared with either Doppler echocardiograms or cardiac catheterization images. An area of decreased signal that correlated spatially and temporally with regurgitant blood flow was seen in all instances in which valvular incompetence was demonstrated on either Doppler echocardiograms or cardiac catheterization images (20 valves). This abnormality was seen in nine of 36 cases without valvular incompetence. Cine MR imaging may be sensitive to turbulence and thus sensitive to valvular regurgitation.

Aortic Valve Insufficiency↗

Two-second MR images: comparison with spin-echo images in 29 patients.

MR images can be obtained with a 2-sec scan time when an extremely short repetition rate (22 msec), limited flip angle (30 degrees), and gradient refocused echoes are used. Comparison of 415 such images obtained in 29 patients with routine T1-weighted (TR 500, TE 25) and T2-weighted (TR 2000, TE 80) images showed that images free of respiratory artifacts could be obtained in all patients. Although abdominal organs were well seen with 2-sec scan time, overall evaluation of these organs was better on routine T1-weighted images. Vascular structures, however, were seen as well or better on the 2-sec images in 60% of cases. The images were extremely sensitive to field nonhomogeneity, and metallic artifact was exaggerated in five patients with surgical clips. Two-sec MR images provide a rapid method of localizing abdominal organs for further evaluation. The sensitivity to blood flow may assist in the assessment of vascular patency.

Adrenal Glands↗

Cine MR determination of left ventricular ejection fraction.

Cine MR imaging provides tomographic images of the heart with both high spatial and high temporal resolution. As many as 32 images per cardiac cycle can be acquired with up to four separate anatomic slices and a total imaging time of 128 cardiac cycles. End-diastolic and end-systolic volumes were determined in 11 patients, and ejection fractions were calculated. The results correlated linearly with those from cardiac catheterization (correlation coefficient of .88). We conclude that cine MR imaging can be used to obtain quantitative information about the heart and has the potential to become a valuable noninvasive means of cardiac evaluation.

Cardiac Catheterization↗

Chemical-shift magnetic resonance imaging of two-line spectra by gradient reversal.

A method of chemical-shift imaging is described using the invariance of chemical shifts to changes in magnetic field gradients used for frequency encoding of position in imaging. This enables separation of the effects on the observed signal of chemical shift from the effects of different positions along the imaging gradient when the signal is observed with different gradients. A simple implementation for a two-line spectrum is presented using signals observed with normal and reversed imaging gradients. This is used to create "fat" and "water" images of the thigh.

Adipose Tissue↗

Intracranial intravenous digital subtraction angiography.

Intravenous digital subtraction angiography (iDSA) promises to significantly alter the use of conventional cerebral angiography in the workup of neurological patients. Understanding its diagnostic potential and its limitations are important in incorporating this new examination into the diagnostic thought process of neuroradiologic tests. Different image processing techniques such as integration of mask and contrast images promise to improve image quality for neuroradiologic application. At present, iDSA is suitable for the diagnosis and follow-up of vascular lesions (atherosclerosis, aneurysms, arteriovenous malformations, venous sinus occlusion), and tumor (meningioma). Although limited, the spatial resolution of iDSA studies is capable of demonstrating diffuse vascular disease such as arteritis and vasospasm after subarachnoid hemorrhage. In some patients in conjunction with the CT scan, iDSA may prove sufficient as the primary and only diagnostic angiographic test necessary, supplanting conventional angiography.

Arteriosclerosis↗

Intravenous carotid arteriography using line-scanned digital radiography.

Digital subtraction and an experimental system for line-scanned radiography were used to image the bifurcations of the carotid arteries. The subtracted images were obtained before and after injections of contrast media. The anatomy of the extracranial carotid arteries was demonstrated in most patients, and verified by selective catheter arteriograms. Unsuccessful studies were attributed to improper timing while obtaining the images, and to venous occlusion. Artifacts produced by motion limit the temporal subtraction method.

Angiography↗

Physiologic motion phantom for MRI applications.

To address the need for a complex physiologic motion phantom for use in MR applications, such as the verification of techniques for measuring myocardial motion dynamics and motion insensitive pulse sequences, a computer-controlled motion phantom has been designed. The phantom, which consists of a deformable silicone gel annulus mounted on a translation stage, can undergo a range of bulk motions and deformations. Available motions include bulk rotation and translation, rotational shear, axial shear, and combinations of some or all of these motions. In this paper, the capability of the phantom to produce accurate constant and time-varying waveforms is demonstrated. In the current implementation, peak linear translation and rotation rates are 175 mm s-1 and 10 rad s-1, respectively. Cycle-to-cycle reproducibility is excellent, with variations of less than .003 radians over the period of hours while undergoing rotational shear. The phantom has been designed in a flexible fashion so that various test objects can be scanned while undergoing bulk translation and can be adapted to produce different deformations.

Hemodynamics↗