Valvular regurgitation: dynamic MR imaging.

Abstract

Cine magnetic resonance (MR) imaging is a new technique that combines short repetition times, limited flip angles, gradient refocused echoes, and cardiac gating. This technique has a temporal resolution of up to 32 time frames per cardiac cycle and accentuates signal from flowing blood. Cine MR images of 56 valves in 27 patients were evaluated and compared with either Doppler echocardiograms or cardiac catheterization images. An area of decreased signal that correlated spatially and temporally with regurgitant blood flow was seen in all instances in which valvular incompetence was demonstrated on either Doppler echocardiograms or cardiac catheterization images (20 valves). This abnormality was seen in nine of 36 cases without valvular incompetence. Cine MR imaging may be sensitive to turbulence and thus sensitive to valvular regurgitation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Utz, R J Herfkens, J A Heinsimer, A Shimakawa, G Glover, N Pelc. 1988. Valvular regurgitation: dynamic MR imaging.. https://doi.org/10.1148/radiology.168.1.3380987

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Clinical and echocardiographic assessment of the Medtronic Advantage aortic valve prosthesis: the Scandinavian multicentre, prospective study.

OBJECTIVE: The aim of this report is the prospective, multicentre evaluation of clinical results and haemodynamic performance of the Medtronic Advantage aortic valve prosthesis. METHODS: From April 2001 to June 2003, 166 patients (male:female 125:41; mean (SD) age 61.8 (11.8) years) received an aortic advantage valve prosthesis. Complete cumulative follow-up was 242.7 patient-years (maximum 3.2; mean 1.6 years). Postoperatively, patients underwent early (within 30 days) and 1 year transthoracic echocardiography. RESULTS: 30 day mortality was 2.4% (n = 4). Kaplan-Meier estimates of freedom from complications and linearised rates were as follows: 96.9 (1.6)% survival; 94.7 (1.3)% (2.06 patients/year) thrombo-embolism; 99.4 (0.6)% (0.4 patients/year) bleeding; 98.8 (0.9)% (0.8 patients/year) non-structural valve dysfunction; 98.8 (0.9)% (0.8 patients/year) reoperation. Valvular mean pressure gradients ranged from 16 (3) mm Hg for size 19 to 7 (2) mm Hg for size 27 and the corresponding effective orifice areas ranged from 1.2 (0.25) to 3.2 (0.66) cm(2). In all, left ventricular mass significantly decreased (p<0.001) and fractional shortening increased (p<0.001) from postoperative to 1 year echocardiography. CONCLUSIONS: Haemodynamic performance and early clinical results of Medtronic advantage in the aortic position were satisfactory and comparable with those of other bileaflet valves in current clinical use.

Aortic Valve Insufficiency↗

Aortic insufficiency due to a partial left-coronary aortic valve prolapse and the detection of two small interatrial jets after blunt thoracic trauma.

Aortic valve regurgitation due to blunt thoracic trauma is a rare complication. Autopsy studies have been shown that the aortic valve is the most often lacerated one among the heart valves. Actually, we describe a case of a 47 year old man with the signs of heart failure after a blunt thoracic trauma 2 months before caused by aortic insufficiency due to a partial left-coronary aortic valve prolapse. Furthermore, transthoracic and transesophageal echocardiography revealed two small jets between the left and the right atrium.

Aortic Valve Insufficiency↗