PubMed Health⌕ Search

Biomedical subjects

Nirlep A Patel

Publications and source records attributed to Nirlep A Patel.

5 recordsLinked to original sources

High-resolution imaging of progressive articular cartilage degeneration.

The objective of this study was to develop and verify a new technique for monitoring the progression of osteoarthritis (OA) by combining a rat model with the imaging modality optical coherence tomography (OCT). Time-sequential, in vivo, OCT imaging was performed on the left femoral condyles of 12 Wistar rats following sodium-iodoacetic acid-induced OA progression. The right femoral condyles (untreated) were also imaged and served as controls. Imaging was performed on days 0, 10, 20, 30, and 60 with an OCT system capable of acquiring images at four frames per second and an axial resolution of 5 microm. Progressive changes were analyzed using an OA scoring system. OCT successfully identified progressive cartilage degeneration as well as alteration of the cartilage/bone interface. Significant changes to both of these structures were observed in the sodium-iodoacetic acid-injected condyles. Structural changes detected with OCT were confirmed histologically. OCT in combination with a well-known model used in arthritis research represents a powerful tool for following degenerative joint disease progression in a given animal by detecting changes to the cartilage/bone interface and articular cartilage.

Animals↗

Monitoring osteoarthritis in the rat model using optical coherence tomography.

OBJECTIVE: A need exists for an animal model to assess therapeutics for osteoarthritis (OA) without sacrificing the animal. Our goal is to assess the progression of experimentally induced osteoarthritis in the rat knee joint by monitoring articular cartilage thickness, surface abnormalities, and collagen organization using a new technology known as optical coherence tomography (OCT). DESIGN: OA was generated in Wistar Hanover rats via injection of sodium iodoacetate into the left articular joint of the knee while normal saline was injected as a control in the contralateral right knee. Rats were sacrificed at 1-, 2-, 3-, 4-, and 8-week intervals and the knee joints were subsequently harvested and imaged using normal and polarization sensitive OCT (PS-OCT). Treated knees were compared to normal counterparts in the contralateral leg. Following imaging, knees underwent both routine histological processing and picrosirus staining for organized collagen. RESULTS: OCT images indicate that injection of sodium iodoacetate resulted in a progressive decrease in cartilage thickness and loss of the bone-cartilage interface which correlated with histology. In addition, PS-OCT was able to detect collagen disorganization, an early indicator of OA. CONCLUSIONS: The use of OCT in combination with the induction of OA in rats is a promising new animal model for assessing articular changes with the goal of monitoring therapeutics longitudinally. Future work will extend the model to in vivo assessments.

Animals↗

Using optical coherence tomography to guide articular cartilage ablation.

Current clinical imaging technologies are not capable of accurately resolving the microscopic components of articular cartilage. Optical coherence tomography (OCT) is a recently developed imaging modality analogous to ultrasound--OCT measures backreflection of infrared light instead of sound. In the study reported here, we wanted to determine the efficacy of OCT for monitoring cartilage laser ablation. Real-time imaging was conducted on bovine cartilage ablated by an argon laser in vitro. Image sequences were generated illustrating the extent of tissue degradation postablation. The images accurately correlated with histology. These results indicate that current ablation procedures could benefit from OCT guidance.

Animals↗

Guidance of aortic ablation using optical coherence tomography.

PURPOSE: There is a significant need for an imaging modality that is capable of providing guidance for intravascular procedures, as current technologies suffer from significant limitations. In particular, laser ablation of in-stent restenosis, revascularization of chronic total occlusions, and pulmonary vein ablation could benefit from guidance. Optical coherence tomography (OCT), a recently introduced technology, is similar to ultrasound except that it measures the back-reflection of infrared light instead of sound. This study examines the ability of OCT to guide vascular laser ablation. METHODS: Aorta samples underwent laser ablation using an argon laser at varying power outputs and were monitored with OCT collecting images at 4 frames. Samples were compared to the corresponding histopathology. RESULTS: Arterial layers could be differentiated in the images sequences. This allowed correlation of changes in the OCT image with power and duration in addition to histopathology. CONCLUSIONS: OCT provides real-time guidance of arterial ablation. At 4 frames, OCT was successfully able to show the microstructural changes in the vessel wall during laser ablation. Since current ablation procedures often injure surrounding tissue, the ability to minimize collateral damage to the adjoining tissue represents a useful advantage of this system. This study suggests a possible role for OCT in the guidance of intravascular procedures.

Animals↗

Review of the ability of optical coherence tomography to characterize plaque, including a comparison with intravascular ultrasound.

Over the last 50 years the introduction of several imaging technologies have been pivotal in reducing mortality associated with coronary artery disease. However coronary disease continues to be the leading cause of mortality in the industrialized world. Optical coherence tomography (OCT) has recently been introduced for micron scale intravascular imaging. It is analogous to ultrasound, measuring the intensity of back-reflected infrared light instead of sound. Some of the advantages of OCT include its resolution, which is higher than any currently available imaging technology and acquisition rates are near video speed. Unlike ultrasound, OCT catheters consist of simple fiber optics and contain no transducers within their frame, thereby making imaging catheters both inexpensive and small. Currently, the smallest catheters have a cross-sectional diameter of 0.014". OCT systems are compact and portable and can be combined with a range of spectroscopic techniques. We review the application of OCT to intracoronary imaging.

Animals↗