PubMed Health⌕ Search

Biomedical subjects

O Dössel

Publications and source records attributed to O Dössel.

At least 19 recordsLinked to original sources

Comparison of macroscopic models of excitation and force propagation in the heart.

Computer aided simulations of the heart provide knowledge of phenomena, which are commonly neither visible nor measurable with current techniques. This knowledge can be applied e.g. in cardiologic diagnosis and therapy. A variety of models was created to reconstruct cardiac processes, e.g. electrical propagation and force development. In this work different macroscopic models were compared, i.e. models based on excitation-diffusion equations and cellular automata. The comparison was carried out concerning reconstruct-ability of cardiac phenomena, mathematical and biophysical foundation as well as computational expense. Particularly, the reconstruct-ability of electromechanic feedback mechanisms was examined. Perspectives for further developments and improvements of models were given.

Animals↗

Excitation propagation and force development in the left ventricle of the visible female data set.

Simulations of the electro-mechanical behavior of the heart improve the comprehension of the mechanisms of the cardiovascular system. In this study a left ventricular model including electrical excitation and force development is presented. The electrical model consists of a complex electrophysiological cell model and a monodomain excitation diffusion model. The force development bases on the intracellular calcium concentration and is calculated with a force model. It consists--like the electrophysiological model--of non-linear coupled differential equations. Simulations are obtained in a realistic and anisotropic model of the left ventricle of the Visible Female data set provided by the National Library of Medicine, USA. Effects to the mechanical behavior will be examined in future.

Anatomy, Cross-Sectional↗

Comparison of regularization techniques for the reconstruction of transmembrane potentials in the heart.

Computer simulations to reconstruct the transmembrane potential distribution were performed for an anisotropic finite element model of the heart. Transmembrane potential was reconstructed in the form of 3D patches. Test patterns generated with a cellular automaton were used. Tikhonov 0-order and 2-order reconstruction techniques were compared. Tikhonov 2-order regularization was shown to deliver better solutions; this is demonstrated by the inspection of the source space of the inverse problem and by the comparison of the correlation coefficients between the reconstructed and original distributions. Time information was incorporated into the regularization.

Body Surface Potential Mapping↗

Calculation of the dielectric properties of biological tissue using simple models of cell patches.

The measurement of the dielectric properties of biological tissue is of increasing scientific relevance. Models for the comprehension of the dielectric properties at various frequencies have been successfully set up. However, students often have problems in understanding the effects taking place on cellular level which lead to the observed dispersion. A numerical model of a biological tissue brick composed of single cells (micron-dimensions) between two plate electrodes is presented in this study. An electrical current in a range of 1 Hz to 3 GHz was applied to the electrodes and hence to the tissue model. Using an equivalent series circuit of a resistor and a capacitor it is possible to calculate the effective equivalent dielectric properties of the whole tissue model. The results show an increasing conductivity and decreasing permittivity with increasing frequency. This corresponds to experimental results obtained with different biological tissues.

Algorithms↗

Simulation of non-contact measurement of the electrical impedance using an anatomical model.

The measurement of the impedance of biological tissue can be a non-invasive method to find new data of diagnostic relevance. A system for a non-contact measurement of the electrical impedance of biological tissue is presented. The system consists of an excitation coil and two sensing coils, an upper and a lower coil. If the two sensing coils are coupled it can be used as a gradiometer coil. Numerical experiments with focus on the eddy currents in the tissue and on the detection of the small changes of the signal are carried out to calculate the fields, eddy current distributions and induced voltages. Hereby tests with different frequencies of the excitation current and different conductivities of a tissue block are used. Then the homogeneous tissue block is replaced with a fraction of the arm of an anatomical model which contains different tissue classes.

Computer Simulation↗

Numerical field calculation of patient return electrodes in electrosurgery.

In order to examine the warming up characteristics during application of a new electrode design for a patient return electrode of an electrosurgical system numerical field calculations were performed in this study. A multi-layer thigh model was provided for this purpose, to which the patient return electrode and the active electrode were connected. The simulation geometry as well as the dielectric tissue parameters were set according to the current frequency. The heating up at the skin surface by the flowing current was evaluated. The results were compared with experimental thermographical measurements.

Computer Simulation↗

Imaging characteristics of different multichannel magnetocardiographic systems.

In this study a comparison of multichannel magnetocardiographic systems is performed with respect to the "detectable" information content. We investigate the lead-field matrices, the slope of the singular values and the source spaces of three different devices: the VectorView (Neuromag: magnetometer-gradiometer mixed device) of the BioMag Laboratory, Helsinki University Central Hospital (HUCH), the arrangement of electronically coupled magnetometers of the Physikalisch-Technische Bundesanstalt Berlin (PTB) and a virtual sensor geometry which was optimized for an improved slope of the singular values at the Institute of Biomedical Engineering, Karlsruhe.

Adult↗

Magnetic resonance imaging with implanted neurostimulators: numerical calculation of the induced heating.

Magnetic resonance imaging (MRI) is still contraindicated in patients with implanted active medical devices, as the applied radiofrequency (RF) fields can lead to significant heating of the implants and the electrodes. A head model with an implanted deep brain stimulation electrode (DBS) was exposed to a continuous RF-field similar to the excitational field used in MRI at a frequency of 64 MHz. In this study a two-step procedure for the accurate estimation of electrode-heating during MRI is presented. First the energy loss was calculated in the frequency domain during an applied RF-pulse. Then a thermodynamic algorithm taking heat transfer mechanisms into account was used. The applied method showed to be numerically stable and gave more accurate results than first calculated using a simple worst-case approximation.

Algorithms↗

Development of a cost-effective and MRI compatible temperature measurement system.

A reliable temperature measurement system working inside a MRI-system is required in order to determine the amount of local temperature rise during application of radiofrequency fields on medical implants and thus to ensure patient safety. Hence the aim of this study was to develop a cost-effective temperature measurement system suitable for use in a MRI system to investigate this heating having mainly phantom experiments in mind. Three active temperature measurement systems were set up, the first using a PTC as the temperature sensor, the other two with platinum resistors of 100 omega and 1000 omega. Interference tests in a MRI systems were performed. It could be shown that a stable temperature measurement at a resolution of 0.1 degree C could be established.

Cost-Benefit Analysis↗

Numerical calculations of switched magnetic field gradients during magnetic resonance imaging.

During magnetic resonance imaging (MRI) pulse-sequences the human body is exposed to switched magnetic gradient fields. These gradients become stronger and are switched faster for fast imaging. Effects resulting from these fields with trapezoidal waveforms are on the one hand sensory perception of induced currents and on the other hand muscular and cardiac stimulation. All three components of the current density induced by gradient pulse sequence were analysed in a high-resolution model of the human torso. The evaluation of the calculated data was performed thoroughly in the region of the heart muscle of the torso model to find out how different waveforms of the switched gradient field influence strength and direction of induced currents.

Electrocardiography↗

Thermal heating of human tissue induced by electromagnetic fields of magnetic resonance imaging.

The paper presents a simulation of the transient temperature distribution in the human body caused by induced eddy currents during magnetic resonance imaging (MRI). In a first simulation the validity of the used heat conduction equation was proven using a simple example of a cool-down-process of a sphere. Thereafter the heating of a phantom model with an implanted electrode placed in a MRI-System (active body coil) was examined. The resulting increase in temperature was compared with existing measurements. Finally the implications of the heating of the tissue are discussed based on the observed experimental and numerical results.

Body Temperature Regulation↗

Simulation of a birdcage and a ceramic cavity HF-resonator for high magnetic fields in magnetic resonance imaging.

The aim of this work was the 3D-simulation of a dielectric resonator for high-field-MRI. A 12-rod-bird-cage-resonator was simulated in a first step, in order to verify the capability of the commercial simulation software MAFIA to simulate homogeneous, transversal B-fields in resonators. The second step was the simulation of frequency-independent dielectric ceramic resonators for static magnetic field strengths of 7 T and 12 T (294 MHz and 504 MHz respectively). The results were compared to the measured results of a manufactured TiO2- and a Al2O3-resonator. Only minor deviations showed up. These results led to the conclusion that dielectric resonators for high field MRI can be optimised using numerical field calculation software.

Artifacts↗

Development and characterisation of a ceramic HF-resonator for the MR-tomography.

Future trends in magnetic resonance imaging (MRI) lead to higher magnetic field strengths of the static magnetic fields and as an implication of that to much higher frequencies. Nowadays a common model of a send-receive coil is the birdcage resonator. However it is very difficult to find an optimal L/C-relation for the capacities and inductivities at frequencies above 300 MHz. The idea is to build a completely new send-receive resonator without discrete network elements. The solution presented in this work is the development of a fully ceramic resonator with a high dielectric constant (between 30-100) and a low loss factor (tan delta approximately 10(3)). This approach has shown to produce a stable transversal magnetic field at the desired MR-frequencies above 300 MHz.

Artifacts↗

Hyperelastic description of elastomechanic properties of the heart: a new material law and its application.

Knowledge concerning passive mechanic cardiac properties is necessary to model behavior of whole hearts. Commonly, a continuum mechanics based description is chosen in conjunction with the finite element method. The aim of this work is to summarize, derive and evaluate hyperelastic material laws for inhomogeneous, anisotropic myocardium. Hence, different material laws were set up and their parameters were determined taking measurement data in literature into account. The material laws were compared from a theoretical and numerical point of view. Furthermore, the application of continuum mechanics based methods is evaluated concerning aspects of numerical solution and spatial discretisation. In further work the laws will be implemented and integrated in an existing software environment, which allows the calculation of deformations in complex geometries.

Anisotropy↗

Modeling force development in the sarcomere in consideration of electromechanical coupling.

Models of the cellular force development simulate the contractive behavior of the sarcomere. In conjunction with electrophysiological models they can contribute to a better comprehension of physiology and pathologies. Aim of this study is to examine the coupling of cellular electrophysiological processes and force development. For that a graphical user interface was developed to simplify the parameterization and calculation of the models as well as to present the results graphically. A feedback mechanism is introduced to pay attention to close connections between force development and intracellular processes. On basis of various tests with different boundary conditions, new force models are developed, parameterized, validated and compared with models in literature. In future studies the results will be tested in multiple cell organization.

Actins↗

Design of a system for contact-free measurement of the conductivity of biological tissue.

The electrical impedance of tissue can give important informations about the viability of the tissue. A non-invasive and contact-free measuring system using an inductive sensor is presented. Using a single pick-up coil the system is not sensitive enough for measuring the small changes in conductivity of biological tissue. Employing a gradiometer instead of a single pick-up coil can improve the resolution of the system. The developed data acquisition system is realized using four parts: A lock-in-amplifier, providing a sinusoidal signal and measuring the signal of the sensor, a power amplifier, driving the excitation coil of the sensor, the inductive sensor and a preamplifier for buffering a reference signal and amplifying the output signal of the sensor. In this paper the focus is on the hardware that was set up. Results of measurements on inhomogeneous phantoms are shown.

Amplifiers, Electronic↗