Planar system for magnetic induction conductivity measurement using a sensor matrix.

Abstract

In this study the performance of an axial gradiometer sensor for magnetic induction tomography was investigated and the results of measurements to determine the precision and sensitivity of the sensor were undertaken. In the first part of the study a single gradiometer sensor was used and the noise and drift were measured for two excitation current values at a single frequency of 600 kHz. The variations of the real and imaginary received signal components with conductivity were then obtained for samples with 0-5 S m(-1). Both sets of measurements were repeated using two different forms of capacitive shielding. In the second part of the study the results of preliminary measurements obtained with a 2 x 2 planar matrix of axial gradiometers are given. The results of a simulation of a similar matrix using a commercial electromagnetic field calculation programme are also presented for comparison. For the sample utilized, the sensor output showed a linear variation with conductivity for the imaginary component of 0.033 mV S(-1) m using an excitation current of 316 mA at 600 kHz. No apparent correlation with conductivity for the real component was observed. The noise and drift of the imaginary component of the sensor output were 0.001 mV and 0.006 mV respectively, for the same excitation current. The results of the planar matrix measurements and simulations suggest that significant sensitivity is provided by using the measurement coils of the adjacent sensors. The measurement results however suggest that large improvements in the sensor noise and drift performance are required for these data to be of use.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C H Riedel, M Keppelen, S Nani, R D Merges, O Dössel. 2004. Planar system for magnetic induction conductivity measurement using a sensor matrix.. https://doi.org/10.1088/0967-3334%2F25%2F1%2F043

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗