PubMed Health⌕ Search

Biomedical subjects

O Karakida

Publications and source records attributed to O Karakida.

At least 19 recordsLinked to original sources

Diurnal T2 value changes in the lumbar intervertebral discs.

AIM: To investigate if there is any in vivo diurnal T2 value changes in the nucleus pulposus in normal and degenerated lumbar intervertebral discs. MATERIALS AND METHODS: Eighteen volunteers (16 men, two women) with no symptoms related to lumbar disease were imaged in the morning before beginning daily work and in the evening after finishing work. Sagittal fast spin-echo T2-weighted images were obtained, following spin-echo transverse imaging for T2 analysis. RESULTS: The normal disc group (n=71) showed statistically significant diurnal T2 value changes (p<0.001), whilst the degenerating disc group (n=19) showed no significant diurnal changes. The normal disc group up to age 34 years showed statistically significant diurnal T2 value changes. However no significant changes were demonstrated after the age 35 years. CONCLUSION: Statistically significant diurnal T2 value changes in the normal lumbar intervertebral discs were demonstrated. Disappearance of the diurnal T2 value changes in the normal discs after the age 35 years was revealed for the first time and thought to be an aspect of aging, not caused by degeneration.

Adult↗

Role of magnetization transfer imaging in bone tumors.

RATIONALE AND OBJECTIVES: The authors evaluated the role of magnetization transfer imaging in differentiation of bone tumors, with special emphasis on cartilaginous tumors. MATERIALS AND METHODS: Fifty-one patients with skeletal tumors or tumor-like lesions who had undergone magnetic resonance (MR) imaging were included. The tumors were divided into three groups according to their gross appearance and the origin of tissue: cyst, cartilaginous tumor, and noncartilaginous solid tumor. A gradient-recalled acquisition in the steady state sequence was used for MR imaging, and examinations were performed both with and without off-resonance magnetization transfer pulses. Magnetization transfer ratios were obtained as an indicator of magnetization transfer effect of the lesions and were compared. Then, the magnetization transfer ratios of all tumors in the cartilaginous tumor group were compared. The magnetization transfer ratios of benign and malignant solid tumors were also compared. RESULTS: The mean magnetization transfer ratio for cartilaginous tumors was 0.31 +/- 0.08 (standard deviation), and that of cysts and noncartilaginous solid tumors was 0.07 +/- 0.03 and 0.40 +/- 0.14, respectively. Comparisons between the three groups showed statistically significant intergroup differences in magnetization transfer ratio (P < .05). In the cartilaginous tumor category, enchondroma and low-grade chondrosarcoma had a lower magnetization transfer effect than chondroblastoma and mesenchymal chondrosarcoma. The mean magnetization transfer ratios of benign (n = 28) and malignant (n = 18) tumors were 0.35 +/- 0.11 and 0.39 +/- 0.15, respectively; there was no statistically significant intergroup difference (P = .14). CONCLUSION: Magnetization transfer imaging could be useful for categorizing bone tumors as cysts, cartilaginous tumors, or noncartilaginous solid tumors.

Adolescent↗

Intraosseous neurilemmoma of the fibula.

We present a case of intraosseous neurilemmoma of the fibula in a 56-year-old woman. The case showed the typical radiographic appearance except for the presence of spotted calcifications that mimicked a cartilaginous tumor. Enhanced MR images revealed the heterogeneity of the tumor, which consisted of Antoni type A and B tissue.

Bone Neoplasms↗

Ischiopubic insufficiency fractures: MRI appearances.

OBJECTIVE: To evaluate the MRI appearances in insufficiency fractures. DESIGN: A retrospective analysis of spin echo MR images with gadolinium-enhancement was undertaken with the emphasis on the signal change and the shape of the fracture gap and the adjacent bone marrow. PATIENTS: Five elderly women who had ischiopubic insufficiency fractures (pubis, 4; ischium 1) underwent MRI to exclude the possibility of pathologic fractures. RESULTS AND CONCLUSIONS: In no case was contrast enhancement noted at the fracture gap or the adjacent bone marrow, but a cleft-life, elongated bright signal area suggesting "fluid collection" was noted within the fracture gap. Absence of contrast enhancement and "fluid collection" at the fracture gap might suggest non-union of a fracture, which is additional information provided only by MRI.

Aged↗

Hemodialysis-related arthropathy. A prospective MR study with SE and GRE sequences.

PURPOSE: A prospective examination of hemodialysis-related arthropathy by MR imaging with SE and GRE sequences was undertaken to verify whether the low signal intensity on T2-weighted SE images is caused by a paramagnetic susceptibility effect derived from amyloid or from hemosiderin. MATERIAL AND METHODS: Twenty-seven joints (19 hip joints, 6 discovertebral joints of 5 lumbosacral spines and 1 cervical spine, 2 shoulder joints) in 14 patients undergoing long-term hemodialysis (duration 10-22 years, mean 17) were examined with SE T1-weighted, T2-weighted and GRE T2*-weighted sequences. RESULTS: The signal intensity of the intraarticular and periarticular masses of the involved joints was basically isointense to the muscle in all 3 pulse sequences. No significantly low signal area was found on GRE T2*-weighted images. CONCLUSION: The low signal areas in the hemodialysis-related arthropathy on SE T2-weighted images are not caused by a paramagnetic susceptibility effect, but probably by the hypocellular and fibrous nature of amyloid-containing tissues. Therefore the GRE sequence can be helpful for differentiating hemodialysis-related amyloid arthropathy from chronic hemarthrosis or juxta-articular brown tumor.

Adult↗

Epidural dumbbell-shaped chordoma mimicking a neurinoma.

The authors present a case of cervical chordoma which manifested in a 5-year-old boy as a dumbbell-shaped epidural tumor without bone destruction. Both CT and MRI demonstrated tumor features suggesting this diagnosis, which was confirmed by histology.

Child, Preschool↗

Hyaline cartilage: in vivo and in vitro assessment with magnetization transfer imaging.

PURPOSE: To elucidate the magnetization transfer (MT) effects of major components of hyaline cartilage. MATERIALS AND METHODS: The authors evaluated the MT effect of type II collagen and chondroitin sulfate phantoms (concentrations of 0.6%, 1.2%, 2.4%, 4.8%, 9.6%, and 19.2%), mass-cultured rat osteosarcoma-derived cells, and normal articular cartilage of the knee. RESULTS: The MT effect of collagen yielded a decrease in signal intensity of 10% (1.2% collagen) to 31% (19.2% collagen); the decrease varied linearly with collagen concentration. Chondroitin sulfate did not have a statistically significant MT effect. Cell pellets showed a decrease in signal intensity of 22%-26%, which was greater than that of 4.8% collagen. Normal articular cartilage of the knees showed a decrease in signal intensity of 38%-48%. CONCLUSION: The major role of collagen in MT contrast of hyaline cartilage was confirmed. In addition, a higher cellular contribution to the MT effect was also demonstrated.

Adolescent↗

Stress fractures.

Explore the source record for details and available documents.

Fractures, Stress↗

MR findings indicative of hemosiderin in giant-cell tumor of bone: frequency, cause, and diagnostic significance.

OBJECTIVE: We studied the frequency, cause, and diagnostic significance of MR findings indicative of large amounts of hemosiderin in giant-cell tumor of bone. MATERIALS AND METHODS: The clinical, MR, and histologic findings in 16 patients with giant-cell tumors of bone were reviewed. Eight tumors occurred in uncommon locations or in patients who were not in the usual age range; the other eight were more typical. Areas of decreased MR signal intensity considered to be caused by hemosiderin were identified. The number and distribution of RBCs within the tumor were studied histologically, and the presence of hemosiderin was determined on histologic sections made with iron stains. RESULTS: In 10 cases in which MR images showed areas of low signal intensity, large amounts of hemosiderin were noted histologically. The low-signal-intensity areas were nodular, zonal, whorled, or diffuse and occupied at least one fifth of the tumor volume. On histologic examination, many erythrocytes were in direct contact with the tumor cells, and the hemosiderin was seen in both mononuclear and multinuclear tumor cells. CONCLUSION: Hemosiderin is commonly seen on MR images of giant-cell tumors of bone (63%) and is probably related to the extravasated erythrocytes in the tumor and the phagocytic function of the tumor cells. This MR finding supports the diagnosis, even in giant-cell tumors in uncommon locations or in patients who are not in the typical age range.

Adult↗

[Effect of collagen on magnetization transfer contrast assessed in cultured cartilage].

We investigated the effect of collagen on magnetization transfer contrast (MTC) in cultured cartilage. In our culture system, only collagen synthesis was increased by the addition of vitamin C, while proteoglycan synthesis and the number of chondrocytes were unaffected. The MTC effect was assessed by using an off-resonance RF pulse (0.3 KHz off-resonance, sinc wave of 18 msec, maximum amplitude 4.61 x 10(-4)T) on a GRASS sequence. The cartilage cultured with vitamin C showed a higher MTC effect than that cultured without vitamin C. The major role of collagen on MTC was confirmed in living cartilage tissue.

Animals↗

[Detectability of simulated nodules on chest phantom by Fuji computed radiography: comparison of different nodule sizes, configurations and tube voltages].

The detectability of simulated nodules placed on a chest phantom and shown on FCR images has been studied. Different tube voltages (130 kVp, 100 kVp), presence or absence of compensation filter, various sites and different sizes (5 mm/10 mm) and configurations (spherical or broad based) of the nodule were examined. 112 FCR chest phantom images were evaluated by ten radiology specialists utilizing ROC analysis. The detection rate for nodules was influenced in general by the site. The detection rate was as follows in decreasing order: intercostal, overlaid with one rib, two ribs, diaphragm and heart. Detection of nodules of 10 mm in height was mainly influenced by the density of the lung where the nodule was located, whereas that of nodules of 5 mm in height was more dependent on the site of the nodule, probably greatly influenced by the amount of structure mottle. Spherical nodules of 5 mm in height were more frequently recognized than the broad-based ones. High kVp (130 kVp) resulted in a higher detection rate for both sizes of nodules than low kVp (100 kVp). Detection of spherical nodules overlying the heart or diaphragm was improved with the use of a compensation filter.

Humans↗

[Clinical application of digital TV tomosynthesis to disorders of the wrist and their post-operative evaluation].

The clinical utility of digital TV tomosynthesis was assessed in 13 patients with chronic disorders of the wrist and the first carpometacarpal joints, and a post-operative evaluation was carried out. The disorders included nonunion of the scaphoid in five patients, Kienböck's disease in four, subluxation of the distal radioulnar joint in two, and osteoarthrosis of the first carpometacarpal joint in two. The total time needed to obtain two sets of tomographs of a wrist by digital TV tomosynthesis was about 10 minutes, or approximately one third of the time required with conventional methods. The total radiation exposure in obtaining all tomographs of one direction with digital TV tomosynthesis was less than that in obtaining only one tomograph with conventional methods. Digital TV tomosynthetic images were judged superior to conventional tomographs by four orthopedic surgeons and four radiologists, because tomographic blur was reduced in part by a spatial frequency filter processing. Clinically, digital TV tomosynthesis was very helpful in evaluating nonunion of the scaphoid and Kienböck's disease, especially in their post-operative conditions with metallic fixative devices. Digital TV tomosynthesis was found to be a fast, feasible and inexpensive method with low radiation exposure for evaluating disorders of the wrist.

Adult↗

[Radiological and anatomical investigation of calcific tendinitis of the gluteus maximus tendon].

The radiological findings in four cases of gluteus maximus tendinitis were retrospectively analyzed. All the patients underwent radiographic, CT and MRI examinations. Amorphous or round calcifications were detected on lateral radiographs in three cases, and on CT in all cases. A small cortical erosion was observed in three cases on both radiographs and CT. MRI showed a thickened gluteus maximus tendon, but no other specific features. In the supine position, which is common in routine CT and MRI studies, the calcific deposits appeared to be distributed along the vastus lateralis muscle tendon. To correlate these radiographic observations with the topographic anatomy of the tendon's insertion, we investigated 14 thighs of seven cadavers, and clarified that the tendon's insertion was the main component of the lateral femoral intermuscular septum. Consequently we performed MRI on a volunteer in a prone position who was asked to maintain contraction of the gluteus maximus and quadratus femoris muscles. The images obtained showed clearly that the gluteus maximus tendon was directed dorsally. In conclusion, radiography and CT are the modalities of choice for diagnosis of this entity. Additionally, radiologists should be aware that the gluteus maximus tendons are directed laterally as a main part of the lateral femoral intermuscular septum on routine CT and MRI.

Buttocks↗

[High-resolution teleradiology system based on ISDN and small computer].

A high-speed, high-resolution teleradiology system based on the Integrated Services Digital Network (ISDN) is described. The LAN at Saku Central Hospital and the Radiological Department at Shinshu University Hospital (60 km) are interfaced to a Macintosh computer with an image digitizer, interactive display, and network interface. The transmission time for a digitized high-resolution radiographic image with 4.39 megabytes was 358 seconds using a 128 kbps (kilobit-per-second) channel (B1 + B2), and the mean transmission rate was 98.1 kbps. Teleradiology conference is also available using this system. Radiologists can observe the same high-resolution images on the CRT screen simultaneously at two different remote hospitals, indicating a point of interest on the image by means of a mouse cursor. Graphical data of interest to the radiologists are also transmitted and displayed on the CRT.

Computer Communication Networks↗

[Study of X-ray filter and peak kilovoltage in film-screen chest radiographs in regard to detection of simulated pulmonary nodules: comparison between film-screen combination and FCR].

We compared the ability of standard film-screen chest radiographs to detect simulated pulmonary nodules. The radiographs were taken with different X-ray filters and tube voltages. Detection capability was analyzed utilizing receiver operating characteristic (ROC) curves formed from the interpretation of six readers. Nodule detection was slightly better in images obtained with a tube voltage of 135 kVp than with one of 100 kVp (not statistically significant). Approximately equal detection performance was shown by a conventional film-screen system and FCR with three X-ray filter sets: a copper filter backed by aluminium, a tungsten filter backed by yttrium and aluminium, and a lead filter backed by yttrium and aluminium. Results showed less X-ray exposure with the two latter filter sets. Unenhanced FCR images taken with approximately the same X-ray exposure as conventional radiographs showed nearly equal ability to detect the simulated nodules.

Humans↗

[Study of X-ray filter and peak kilovoltage in Fuji Computed Radiography in regard to the detection of simulated pulmonary nodules].

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), to provide better detection of pulmonary nodules and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVp as compared with 100 kVp; 2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the tungsten filter were slightly inferior to the other two filters; and 3) the absorbed dose may be reduced by 30% with the use of a lead filter backed by yttrium and aluminium compared with a copper filter backed by aluminium. We conclude that chest radiography with FCR should preferably be conducted with a higher kilovoltage, e.g., 135 kVp rather than 100 kVp, to ensure a higher detection rate of pulmonary nodules and in conjunction with a lead filter backed by yttrium and aluminium to reduce X-ray exposure to the patient.

Filtration↗