The RBE issues in ion-beam therapy: conclusions of a joint IAEA/ICRU working group regarding quantities and units.

This paper summarises the conclusions of a working group established jointly by the International Atomic Energy Agency (IAEA) and the International Commission on Radiation Units and Measurements (ICRU) to address some of the relative biological effectiveness (RBE) issues encountered in ion-beam therapy. Special emphasis is put on the selection and definition of the involved quantities and units. The isoeffective dose, as introduced here for radiation therapy applications, is the dose that delivered under reference conditions would produce the same clinical effects as the actual treatment in a given system, all other conditions being identical. It is expressed in Gy. The reference treatment conditions are: photon irradiation, 2 Gy per fraction, 5 daily fractions a week. The isoeffective dose D(IsoE) is the product of the physical quantity absorbed dose D and a weighting factor W(IsoE). W(IsoE) is an inclusive weighting factor that takes into account all factors that could influence the clinical effects like dose per fraction, overall time, radiation quality (RQ), biological system and effects. The numerical value of W(IsoE) is selected by the radiation-oncology team for a given patient (or treatment protocol). It is part of the treatment prescription. Evaluation of the influence of RQ on W(IsoE) raises complex problems because of the clinically significant RBE variations with biological effect (late vs. early) and position in depth in the tissues which is a problem specific to ion-beam therapy. Comparison of the isoeffective dose with the equivalent dose frequently used in proton- and ion-beam therapy is discussed.

Heavy Ion Radiotherapy↗

Configuration of the electron transport algorithm of PENELOPE to simulate ion chambers.

The stability of the electron transport algorithm implemented in the Monte Carlo code PENELOPE with respect to variations of its step length is analysed in the context of the simulation of ion chambers used in photon and electron dosimetry. More precisely, the degree of violation of the Fano theorem is quantified (to the 0.1% level) as a function of the simulation parameters that determine the step size. To meet the premises of the theorem, we define an infinite graphite phantom with a cavity delimited by two parallel planes (i.e., a slab) and filled with a 'gas' that has the same composition as graphite but a mass density a thousand-fold smaller. The cavity walls and the gas have identical cross sections, including the density effect associated with inelastic collisions. Electrons with initial kinetic energies equal to 0.01, 0.1, 1, 10 or 20 MeV are generated in the wall and in the gas with a uniform intensity per unit mass. Two configurations, motivated by the design of pancake- and thimble-type chambers, are considered, namely, with the initial direction of emission perpendicular or parallel to the gas-wall interface. This version of the Fano test avoids the need of photon regeneration and the calculation of photon energy absorption coefficients, two ingredients that are common to some alternative definitions of equivalent tests. In order to reduce the number of variables in the analysis, a global new simulation parameter, called the speedup parameter (a), is introduced. It is shown that setting a = 0.2, corresponding to values of the usual PENELOPE parameters of C1 = C2 = 0.02 and values of WCC and WCR that depend on the initial and absorption energies, is appropriate for maximum tolerances of the order of 0.2% with respect to an analogue, i.e., interaction-by-interaction, simulation of the same problem. The precise values of WCC and WCR do not seem to be critical to achieve this level of accuracy. The step-size dependence of the absorbed dose is explained in the light of the properties of PENELOPE's transport mechanics. This work is intended to help users to adopt an optimal configuration that guarantees both a high-accuracy calculation of the absorbed dose and a reasonably short computing time.

Algorithms↗

Calculation of stopping power ratios for carbon ion dosimetry.

Water-to-air stopping power ratio calculations for the ionization chamber dosimetry of clinical carbon ion beams with initial energies from 50 to 450 MeV/u have been performed using the Monte Carlo technique. To simulate the transport of a particle in water the computer code SHIELD-HIT v2 was used, which is a newly developed version where substantial modifications were implemented on its predecessor SHIELD-HIT v1 (Gudowska et al 2004 Phys. Med. Biol. 49 1933-58). The code was completely rewritten replacing formerly used single precision variables with double precision variables. The lowest particle transport specific energy was decreased from 1 MeV/u down to 10 keV/u by modifying the Bethe-Bloch formula, thus widening its range for medical dosimetry applications. In addition, the code includes optionally MSTAR and ICRU-73 stopping power data. The fragmentation model was verified and its parameters were also adjusted. The present code version shows excellent agreement with experimental data. It has been used to compute the physical quantities needed for the calculation of stopping power ratios, s(water,air), of carbon beams. Compared with the recommended constant value given in the IAEA Code of Practice, the differences found in the present investigations varied between 0.5% and 1% at the plateau region, respectively for 400 MeV/u and 50 MeV/u beams, and up to 2.3% in the vicinity of the Bragg peak for 50 MeV/u.

Carbon Radioisotopes↗

Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams.

Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron equilibrium in the radiation field. It is questionable that stopping-power ratio in dosimetry protocols, obtained for broad photon beams and quasi-electron equilibrium conditions, can be used in the dosimetry of narrow fields while keeping the uncertainty at the same level as for the broad beams used in accelerator calibrations. Monte Carlo simulations have been performed for two 6 MV clinical accelerators (Elekta SL-18 and Siemens Mevatron Primus), equipped with radiosurgery applicators and MLC. Narrow circular and Z-shaped on-axis and off-axis fields, as well as broad IMRT configured beams, have been simulated together with reference 10 x 10 cm2 beams. Phase-space data have been used to generate 3D dose distributions which have been compared satisfactorily with experimental profiles (ion chamber, diodes and film). Photon and electron spectra at various depths in water have been calculated, followed by Spencer-Attix (delta = 10 keV) stopping-power ratio calculations which have been compared to those used in the IAEA TRS-398 code of practice. For water/air and PMMA/air stopping-power ratios, agreements within 0.1% have been obtained for the 10 x 10 cm2 fields. For radiosurgery applicators and narrow MLC beams, the calculated s(w,air) values agree with the reference within +/-0.3%, well within the estimated standard uncertainty of the reference stopping-power ratios (0.5%). Ionization chamber dosimetry of narrow beams at the photon qualities used in this work (6 MV) can therefore be based on stopping-power ratios data in dosimetry protocols. For a modulated 6 MV broad beam used in clinical IMRT, s(w,air) agrees within 0.1% with the value for 10 x 10 cm2, confirming that at low energies IMRT absolute dosimetry can also be based on data for open reference fields. At higher energies (24 MV) the difference in s(w,air) was up to 1.1%, indicating that the use of protocol data for narrow beams in such cases is less accurate than at low energies, and detailed calculations of the dosimetry parameters involved should be performed if similar accuracy to that of 6 MV is sought.

Algorithms↗

Calculations of electron fluence correction factors using the Monte Carlo code PENELOPE.

In electron-beam dosimetry, plastic phantom materials may be used instead of water for the determination of absorbed dose to water. A correction factor phi(water)plastic is then needed for converting the electron fluence in the plastic phantom to the fluence at an equivalent depth in water. The recommended values for this factor given by AAPM TG-25 (1991 Med. Phys. 18 73-109) and the IAEA protocols TRS-381 (1997) and TRS-398 (2000) disagree, in particular at large depths. Calculations of the electron fluence have been done, using the Monte Carlo code PENELOPE, in semi-infinite phantoms of water and common plastic materials (PMMA, clear polystyrene, A-150, polyethylene, Plastic water and Solid water (WT1)). The simulations have been carried out for monoenergetic electron beams of 6, 10 and 20 MeV, as well as for a realistic clinical beam. The simulated fluence correction factors differ from the values in the AAPM and IAEA recommendations by up to 2%, and are in better agreement with factors obtained by Ding et al (1997 Med. Phys. 24 161-76) using EGS4. Our Monte Carlo calculations are also in good accordance with phi(water)plastic values measured by using an almost perturbation-free ion chamber. The important interdependence between depth- and fluence-scaling corrections for plastic phantoms is discussed. Discrepancies between the measured and the recommended values of phi(water)plastic may then be explained considering the different depth-scaling rules used.

Biophysical Phenomena↗

Photon quality correction factors for ionization chambers in an epithermal neutron beam.

Photon quality correction factors (kQy) for ionization chamber photon dosimetry in an epithermal neutron beam were determined according to a modified absorbed dose to water formalism which was extended to mixed radiation fields. We have studied two commercially available ionization chambers in the epithermal neutron beam optimized for BNCT at the facility at Studsvik, Sweden. One of the chambers is nominally neutron insensitive; a magnesium-walled detector flushed with pure argon gas (denoted by Mg/Ar). The second chamber has approximately the same sensitivity for neutrons and photons; it is considered a 'tissue equivalent' detector, with A-150 walls flushed with methane-based tissue-equivalent gas (denoted by TE/TE). The kQy-factors in epithermal neutron beams have previously been assumed to be equal to unity or estimated from measurements in clinical accelerator produced photon beams. In this work the kQy-factors have been determined from absorbed dose calculations using cavity theory together with Monte Carlo derived electron fluences obtained with the MCNP4c system for water and PMMA phantoms. The calculated quality correction factors differ substantially from unity, being in the order of 10% for the Mg/Ar detector at shallow phantom depths, and between 2 and 4% for other depths and for the TE/TE chamber.

Boron Neutron Capture Therapy↗

Study of a selection of 10 historical types of dosemeter: variation of the response to Hp(10) with photon energy and geometry of exposure.

An international collaborative study of cancer risk among workers in the nuclear industry is tinder way to estimate direetly the cancer risk following protracted low-dose exposure to ionising radiation. An essential aspect of this study is the characterisation and quantification of errors in available dose estimates. One major source of errors is dosemeter response in workplace exposure conditions. Little information is available on energy and geometry response for most of the 124 different dosemeters used historically in participating facilities. Experiments were therefore set up to assess this. using 10 dosemeter types representative of those used over time. Results show that the largest errors were associated with the response of early dosemeters to low-energy photon radiation. Good response was found with modern dosemeters. even at low energy. These results are being used to estimate errors in the response for each dosemeter type, used in the participating facilities, so that these can be taken into account in the estimates of cancer risk.

Calibration↗

Aspects of MR image distortions in radiotherapy treatment planning.

BACKGROUND: Registration of computed tomography (CT) and magnetic resonance (MR) images are commonly performed to define the different target regions used in radiotherapy treatment planning (RTTP). The accuracy of target definition will then depend on the spatial accuracy of the CT and MR data, and on the technique used to register the images. CT images are usually regarded as geometrically correct, while MR images are known to suffer from geometric distortion. The aim of this paper is to discuss the possible impact of MR image distortions in the radiotherapy treatment planning process. METHODS: The origin, magnitude, and relative impact of the different sources of geometric distortions that affect the MR image data at different magnetic fields and for different acquisition settings are described. Techniques for distortion correction are reviewed, and their limitations are outlined. The sensitivity of image registration techniques to the presence of geometric distortions in the MR data is discussed. Finally, an overview of image registration techniques used and results obtained in clinical radiotherapy treatment planning applications is given. RESULTS: Spatial distortions in MR images vary with field strength and with the image acquisition protocol. The spatial accuracy generally decreases with distance from the magnet isocenter. Distortion correction techniques based on phantom evaluations cannot adequately model patient-induced distortions. CONCLUSION: Image protocols with high gradient bandwidths should be used to reduce the spatial distortions in MR images. Correction techniques based only on phantom measurements could be sufficient at low magnetic fields, while at higher fields additional corrections of patient-related distortions might be needed. Registration techniques based on matching of Landmark points located far from the magnet isocenter are especially prone to MR distortions.

Abdominal Neoplasms↗

Comparison of the IAEA TRS-398 and AAPM TG-51 absorbed dose to water protocols in the dosimetry of high-energy photon and electron beams.

The International Atomic Energy Agency (IAEA TRS-398) and the American Association of Physicists in Medicine (AAPM TG-51) have published new protocols for the calibration of radiotherapy beams. These protocols are based on the use of an ionization chamber calibrated in terms of absorbed dose to water in a standards laboratory's reference quality beam. This paper compares the recommendations of the two protocols in two ways: (i) by analysing in detail the differences in the basic data included in the two protocols for photon and electron beam dosimetry and (ii) by performing measurements in clinical photon and electron beams and determining the absorbed dose to water following the recommendations of the two protocols. Measurements were made with two Farmer-type ionization chambers and three plane-parallel ionization chamber types in 6, 18 and 25 MV photon beams and 6, 8, 10, 12, 15 and 18 MeV electron beams. The Farmer-type chambers used were NE 2571 and PTW 30001, and the plane-parallel chambers were a Scanditronix-Wellhöfer NACP and Roos, and a PTW Markus chamber. For photon beams, the measured ratios TG-51/TRS-398 of absorbed dose to water Dw ranged between 0.997 and 1.001, with a mean value of 0.999. The ratios for the beam quality correction factors kQ were found to agree to within about +/-0.2% despite significant differences in the method of beam quality specification for photon beams and in the basic data entering into kQ. For electron beams, dose measurements were made using direct N(D,w) calibrations of cylindrical and plane-parallel chambers in a 60Co gamma-ray beam, as well as cross-calibrations of plane-parallel chambers in a high-energy electron beam. For the direct N(D,w) calibrations the ratios TG-51/TRS-398 of absorbed dose to water Dw were found to lie between 0.994 and 1.018 depending upon the chamber and electron beam energy used, with mean values of 0.996, 1.006, and 1.017, respectively, for the cylindrical, well-guarded and not well-guarded plane-parallel chambers. The Dw ratios measured for the cross-calibration procedures varied between 0.993 and 0.997. The largest discrepancies for electron beams between the two protocols arise from the use of different data for the perturbation correction factors p(wall) and p(dis) of cylindrical and plane-parallel chambers, all in 60Co. A detailed analysis of the reasons for the discrepancies is made which includes comparing the formalisms, correction factors and the quantities in the two protocols.

Air↗

Reference dosimetry in clinical high-energy photon beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols.

Task Group 51 (TG-51) of the Radiation Therapy Committee of the American Association of Physicists in Medicine (AAPM) has recently developed a new protocol for the calibration of high-energy photon and electron beams used in radiation therapy. The formalism and the dosimetry procedures recommended in this protocol are based on the use of an ionization chamber calibrated in terms of absorbed dose-to-water in a standards laboratory's 60Co gamma ray beam. This is different from the recommendations given in the AAPM TG-21 protocol, which are based on an exposure calibration factor of an ionization chamber in a 60Co beam. The purpose of this work is to compare the determination of absorbed dose-to-water in reference conditions in high-energy photon beams following the recommendations given in the two dosimetry protocols. This is realized by performing calibrations of photon beams with nominal accelerating potential of 6, 18 and 25 MV, generated by an Elekta MLCi and SL25 series linear accelerator. Two widely used Farmer-type ionization chambers having different composition, PTW 30001 (PMMA wall) and NE 2571 (graphite wall), were used for this study. Ratios of AAPM TG-51 to AAPM TG-21 doses to water are found to be 1.008, 1.007 and 1.009 at 6, 18 and 25 MV, respectively when the PTW chamber is used. The corresponding results for the NE chamber are 1.009, 1.010 and 1.013. The uncertainties for the ratios of the absorbed dose determined by the two protocols are estimated to be about 1.5%. A detailed analysis of the reasons for the discrepancies is made which includes comparing the formalisms, correction factors and quantities in the two protocols, as well as the influence of the implementation of the different standards for chamber calibration. The latter has been found to have a considerable influence on the differences in clinical dosimetry, even larger than the adoption of the new data and recommended procedures, as most intrinsic differences cancel out due to the adoption of the new formalism.

Biophysical Phenomena↗

Reference dosimetry in clinical high-energy electron beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols.

A comparison of the determination of absorbed dose to water in reference conditions with high-energy electron beams (Enominal of 6, 8, 10, 12, 15, and 18 MeV) following the recommendations given in the AAPM TG-51 and in the original TG-21 dosimetry protocols has been made. Six different ionization chamber types have been used, two Farmer-type cylindrical (PTW 30001, PMMA wall; NE 2571, graphite wall) and four plane parallel (PTW Markus, and Scanditronix-Wellhöfer NACP, PPC-05 and Roos PPC-40). Depending upon the cylindrical chamber type used and the beam energy, the doses at dmax determined with TG-51 were higher than with TG-21 by about 1%-3%. Approximately 1% of this difference is due to the differences in the data given in the two protocols; another 1.1%-1.2% difference is due to the change of standards, from air-kerma to absorbed dose to water. For plane-parallel chambers, absorbed doses were determined by using two chamber calibration methods: (i) direct use of the ADCL calibration factors N(60Co)D,w and Nx for each chamber type in the appropriate equations for dose determination recommended by each protocol, and (ii) cross-calibration techniques in a high-energy electron beam, as recommended by TG-21, TG-39, and TG-51. Depending upon the plane-parallel chamber type used and the beam energy, the doses at dmax determined with TG-51 were higher than with TG-21 by about 0.7%-2.9% for the direct calibration procedures and by 0.8%-3.2% for the cross-calibration techniques. Measured values of photon-electron conversion kecal, for the NACP and Markus chambers were found to be 0.3% higher and 1.7% lower than the corresponding values given in TG-51. For the PPC-05 and PPC-40 (Roos) chamber types, the values of kecal were measured to be 0.889 and 0.893, respectively. The uncertainty for the entire calibration chain, starting from the calibration of the ionization chamber in the standards laboratory to the determination of absorbed dose to water in the user beam, has been analyzed for the two formalisms. For cylindrical chambers, the observed differences between the two protocols are within the estimated combined uncertainty of the ratios of absorbed doses for 6 and 8 MeV; however, at higher energies (10< or =E< or =18 MeV), the differences are larger than the estimated combined uncertainties by about 1%. For plane-parallel chambers, the observed differences are within the estimated combined uncertainties for the direct calibration technique; for the cross-calibration technique the differences are within the uncertainty estimates at low energies whereas they are comparable to the uncertainty estimates at higher energies. A detailed analysis of the reasons for the discrepancies is made which includes comparing the formalisms, correction factors, and quantities in the two protocols, as well as the influence of the implementation of the different standards for chamber calibration.

Biophysical Phenomena↗

The IAEA/WHO TLD postal programme for radiotherapy hospitals.

BACKGROUND AND PURPOSE: Since 1969 the International Atomic Energy Agency (IAEA), together with the World Health Organization (WHO), has performed postal TLD audits to verify the calibration of radiotherapy beams in developing countries. MATERIALS AND METHODS: A number of changes have recently been implemented to improve the efficiency of the IAEA/WHO TLD programme. The IAEA has increased the number of participants and reduced significantly the total turn-around time to provide results to the hospitals within the shortest possible time following the TLD irradiations. The IAEA has established a regular follow-up programme for hospitals with results outside acceptance limits of +/- 5%. RESULTS: The IAEA has, over 30 years, verified the calibration of more than 3300 clinical photon beams at approximately 1000 radiotherapy hospitals. Only 65% of those hospitals who receive TLDs for the first time have results within the acceptance limits, while more than 80% of the users that have benefited from a previous TLD audit are successful. The experience of the IAEA in TLD audits has been transferred to the national level. The IAEA offers a standardized TLD methodology, provides guidelines and gives technical back-up to the national TLD networks. CONCLUSION: The unsatisfactory status of the dosimetry for radiotherapy, as noted in the past, is gradually improving; however, the dosimetry practices in many hospitals in developing countries need to be revised in order to reach adequate conformity to hospitals that perform modern radiotherapy in Europe, USA and Australia.

Calibration↗

Comparison of dosimetry recommendations for clinical proton beams.

The formalism and data in the two most recent dosimetry recommendations for clinical proton beams, ICRU Report 59 and the forthcoming IAEA Code of Practice, are compared. Chamber calibrations in terms of air kerma and absorbed dose to water are considered, including five different cylindrical ionization chamber types commonly used in proton beam dosimetry. The methodology for both types of calibration for ionization chambers is described in ICRU Report 59. The procedure based on air kerma calibrations is compared with an alternative formalism based on IAEA Codes of Practice (TRS-277, TRS-381), modified for proton beams. The new IAEA Code of Practice is exclusively based on calibrations in terms of absorbed dose to water and a direct comparison with ICRU Report 59 recommendations is made. Common to the two formalisms are the fundamental quantities Wair and w(air) and their atmospheric conditions of applicability. The difference in the recommended values of the ratio w(air)/Wair (protons to 60Co) is as large as 2.3%. The use of Wair and w(air) values for dry air (IAEA) and for ambient air (ICRU) is a contribution to the discrepancy, and the ICRU usage is questioned. For air kerma based chamber calibrations, ICRU Report 59 does not take into account the effect of different compositions of the build-up cap and chamber wall on the calibration beam quality. For the chamber types included in the study, this introduces discrepancies of up to 1.1%. Combined with differences in the recommended basic data, discrepancies in absorbed dose determination in proton beams of up to 2.1% are found. For the absorbed dose to water based formalism, differences in the formalism, notably the omission of perturbation factors for 60Co in ICRU 59, and data yield discrepancies in calculated kQ factors, and in absorbed dose determinations, between -1.5% and +2.6%, depending on the chamber type and the proton beam quality.

Air↗

Determination of absorbed dose to water in reference conditions for radiotherapy kilovoltage x-rays between 10 and 300 kV: a comparison of the data in the IAEA, IPEMB, DIN and NCS dosimetry protocols.

A comparison of four of the most commonly used dosimetry protocols for the determination of absorbed dose to water in therapeutic kilovoltage x-rays using an ionization chamber (IAEA TRS-277, IPEMB, DIN and NCS) has been carried out. Owing to the different energy ranges and HVLs recommended by each protocol, backscatter factors, water-to-air mass energy absorption coefficient ratios and perturbation correction factors have been recast to a common quality range that all protocols satisfy individually to make a comparison possible. The results of the comparison show that in the sometimes reduced quality range originally included by the different protocols, determinations of absorbed dose to water at all beam qualities agree to within +/-1.0% with that obtained using the second edition of the IAEA TRS-277 code of practice (1997). The extrapolation of data to a common beam quality range practically preserves the agreement for all the protocols except for that issued by the NCS at the extremes of the range, where differences of up to 1.8% and 1.4% have been found for low and medium energies respectively. In all cases the DIN protocol yields very good agreement with TRS-277.

Models, Theoretical↗

Calibration of plane-parallel chambers and determination of p(wall) for the NACP and Roos chambers for 60Co gamma-ray beams.

Procedures for the calibration and use of plane-parallel ionization chambers in high-energy electron and photon beams have been given in the international code of practice IAEA TRS-381. In the present work, plane-parallel ionization chambers of the type PTW-34001 Roos and Scanditronix NACP02 have been calibrated using two N(K)-based procedures. For the NACP chamber the difference between the N(D,air) chamber factors determined in an electron beam and in a 60Co gamma-ray beam, respectively, is of the same magnitude as the experimental uncertainty. Results for the PTW Roos chambers, however, do not agree, in accordance with recent findings of other authors. The value determined in a 60Co gamma-ray beam is questioned and the reason for the discrepancy assigned to the correction factor for the perturbation due to the chamber wall, p(wall). New values of p(wall) have been experimentally determined by comparing absorbed dose measurements based on air-kerma and absorbed dose to water calibration procedures. A new p(wall) factor for the Roos chamber in 60Co gamma-ray beams in water (1.009+/-0.6%) was derived as the weighted average of the different determinations. The value is not significantly higher than the p(wall) factor given in TRS-381 (1.003+/-1.5%), but the combined standard uncertainty is reduced. The chamber to chamber variation for six commercial PTW Roos chambers and a Roos prototype was found to be very small.

Air↗

A comparison between calculated and experimental kQ photon beam quality correction factors.

To validate the calculated values of kQ for high-energy photon beams given in the International Code of Practice for radiotherapy dosimetry based on water-absorbed-dose standards, a comparison with experimental values derived in standards laboratories and in clinical beams has been made. The study includes a compilation of experimental values for ionization chambers of the type NE2561/2611, NE2571, PTW30001 and PR06. The energy dependence of the G(Fe3+) ratio of high-energy x-rays to 60Co gamma-rays by Klassen et al is taken into account for all the Fricke-derived values. For three of the chamber types analysed, the comparison shows that the calculated values are a very good estimate of the average values of kQ in the entire range of photon beam qualities available for clinical use. For the NE2571 chamber type a difference which increases with energy between calculated and experimental kQ factors has been observed; however, the largest difference with a fit describing the entire set of experimental data is always smaller than 0.4%. It is concluded that if the recommendation of the Code of Practice for an individual calibration of the user's chamber at a range of photon beam qualities is not available, the use of calculated kQ factors will yield absorbed dose to water determinations accurate within the uncertainty limits of the majority of experimental data available. The good agreement between calculated and measured values, obtained for practically all the experimental data using TPR(20,10) as photon beam quality specifier, is not satisfied in some cases for two high-energy soft beams used at the Canadian NRC. There appears to be no justification for a change to a different photon beam quality specifier solely on the grounds that such a limited set of data is not described by the same distributions as the rest of the experimental data.

Calibration↗

On the beam quality specification of high-energy photons for radiotherapy dosimetry.

An overview of common photon beam quality specifiers used in radiotherapy dosimetry introduces a reasoned discussion on the advantages and disadvantages of TPR20,10 and PDD(10)x. It is shown that some of the potential advantages of PDD(10)x are also present in other well known beam quality specifiers such as d80. However, all PDD-based beam quality indices, including PDD(10)x, are subject to electron contamination and their determination is affected by practical limitations. The proposed filtration of contaminant electrons by Kosunen and Rogers [Med. Phys. 20, 1181-1188 (1993)] and by Li and Rogers [Med. Phys. 21, 791-798 (1994)] is questioned, not only with regard to the adequacy of using lead as an electron filter, but also in relation to its efficiency (if there were no contamination, restrictions for beam calibrations at dmax would be removed) and practical measurement. It is argued that (i) there is no unique beam quality specifier that works satisfactorily in all possible conditions, for the entire energy range of photon energies used in radiotherapy and all possible accelerators used in hospitals and in standards laboratories, and (ii) TPR20,10 remains to be the most appropriate specifier for clinical photon beams as it has less practical drawbacks than PDD-based quality indices. The final impact on clinical photon beam dosimetry resulting from the use of different photon beam quality specifiers, is that they are not expected to yield a significant change (i.e., more than 0.5% and in most cases well within 0.2%) in the absorbed dose to water in reference conditions for most clinical beams.

Algorithms↗