Calculation of absorbed dose and biological effectiveness from photonuclear reactions in a bremsstrahlung beam of end point 50 MeV.

The absorbed dose due to photonuclear reactions in soft tissue, lung, breast, adipose tissue and cortical bone has been evaluated for a scanned bremsstrahlung beam of end point 50 MeV from a racetrack accelerator. The Monte Carlo code MCNP4B was used to determine the photon source spectrum from the bremsstrahlung target and to simulate the transport of photons through the treatment head and the patient. Photonuclear particle production in tissue was calculated numerically using the energy distributions of photons derived from the Monte Carlo simulations. The transport of photoneutrons in the patient and the photoneutron absorbed dose to tissue were determined using MCNP4B; the absorbed dose due to charged photonuclear particles was calculated numerically assuming total energy absorption in tissue voxels of 1 cm3. The photonuclear absorbed dose to soft tissue, lung, breast and adipose tissue is about (0.11-0.12)+/-0.05% of the maximum photon dose at a depth of 5.5 cm. The absorbed dose to cortical bone is about 45% larger than that to soft tissue. If the contributions from all photoparticles (n, p, 3He and 4He particles and recoils of the residual nuclei) produced in the soft tissue and the accelerator, and from positron radiation and gammas due to induced radioactivity and excited states of the nuclei, are taken into account the total photonuclear absorbed dose delivered to soft tissue is about 0.15+/-0.08% of the maximum photon dose. It has been estimated that the RBE of the photon beam of 50 MV acceleration potential is approximately 2% higher than that of conventional 60Co radiation.

Absorption↗

Improvements in absorbed dose measurements for external radiation therapy using ferrous dosimeter gel and MR imaging (FeMRI).

A ferrous gel, based on ferrous (Fe) sulphate and agarose, was used with a clinical magnetic resonance imaging (MRI) scanner to obtain relative dose distribution data from therapeutic photon and electron beams. The FeMRI gel was scanned using a new MRI acquisition protocol optimized for T1 measurements. Thorough comparisons with silicon semiconductor detector and ionization chamber measurements, as well as with Monte Carlo calculations, were performed in order to quantify the improvements obtained using FeMRI for dose estimations. Most of the relative doses measured with FeMRI were within 2% of the doses measured with other methods. The larger discrepancies (2-4%) found at shallow depths are discussed. The uncertainty in relative dose measurements using FeMRI was significantly improved compared with previously reported results (5-10%, one standard deviation, 1 SD), and is today between 1.6% and 3.3% (depending on dose level, 2 SD). This corresponds to an improvement in the minimum detectable dose (3 SD above background) from approximately 2 Gy to better than 0.6 Gy. The results obtained in this study emphasize the importance of obtaining basic FeMRI dose data before the method is extended to complicated treatment regimes.

Electrons↗

Monte Carlo calculated stopping-power ratios, water/air, for clinical proton dosimetry (50-250 MeV).

Calculations of stopping power ratios, water to air, for the determination of absorbed dose to water in clinical proton beams using ionization chamber measurements have been undertaken using the Monte Carlo method. A computer code to simulate the transport of protons in water (PETRA) has been used to calculate sw.air-data under different degrees of complexity, ranging from values based on primary protons only to data including secondary electrons and high-energy secondary protons produced in nonelastic nuclear collisions. All numerical data are based on ICRU 49 proton stopping powers. Calculations using primary protons have been compared to the simple continuous slowing-down approximation (c.s.d.a.) analytical technique used in proton dosimetry protocols, not finding significant differences that justify elaborate Monte Carlo simulations except beyond the mean range of the protons (the far side of the Bragg peak). The influence of nuclear nonelastic processes, through the detailed generation and transport of secondary protons, on the calculated stopping-power ratios has been found to be negligible. The effect of alpha particles has also been analysed, finding differences smaller than 0.1% from the results excluding them. Discrepancies of up to 0.6% in the plateau region have been found, however, when the production and transport of secondary electrons are taken into account. The large influence of nonelastic nuclear interactions on proton depth-dose distributions shows that the removal of primary protons from the incident beam decreases the peak-to-plateau ratio by a large factor, up to 40% at 250 MeV. It is therefore emphasized that nonelastic nuclear reactions should be included in Monte Carlo simulations of proton beam depth-dose distributions.

Air↗

Correction factors for parallel-plate chambers used in plastic phantoms in electron dosimetry.

In electron beam dosimetry using parallel-plate chambers solid phantoms are sometimes necessary. To obtain the dose to water from the ionization obtained in the solid phantom, fluence correction factors and perturbation factors have to be applied. In this study fluence factors in a perturbation free geometry have been determined experimentally for common phantom materials. Wall perturbation factors for simulated Attix, NACP, and Roos chambers have also been determined for the same materials. Comparative Monte Carlo calculations have been performed using the EGS4 Monte Carlo code. Comparison with data in newly published protocols such as IAEA and IPEMB shows an agreement with the results obtained in this paper to within 1%, demonstrating that the data published in these protocols may be used with reasonable accuracy if recommended phantoms are used. The results also show that if unsuitable phantom materials are used, the wall perturbation factors may differ for different chambers and for different phantom materials by more than 3% and perturbation factors have to be considered in order to obtain a high accuracy in the dose determination.

Dose-Response Relationship, Radiation↗

Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimization.

Proton pencil beams in water, in a format suitable for treatment planning algorithms and covering the radiotherapy energy range (50-250 MeV), have been calculated using a modified version of the Monte Carlo code PTRAN. A simple analytical model has also been developed for calculating proton broad-beam dose distributions which is in excellent agreement with the Monte Carlo calculations. Radial dose distributions are also calculated analytically and narrow proton pencil-beam dose distributions derived. The physical approximations in the Monte Carlo code and in the analytical model together with their limitations are discussed. Examples showing the use of the calculated set of proton pencil beams as input to an existing photon treatment planning algorithm based on biological optimization are given for fully 3D scanned proton pencil beams; these include intensity modulated beams with range shift and scanning in the transversal plane.

Algorithms↗

Wall effects in plane-parallel ionization chambers.

All dosimetry protocols recommend the use of plane-parallel chambers for dose determination in electron beams with energies below 10-15 MeV. The protocols have assumed chamber perturbation effects to be negligible. The new AAPM Protocol (TG39) includes a cavity replacement factor prepl that differs from unity for some chambers, but assumes that the wall perturbation factor, pwall, may be taken as unity. In this paper the perturbation of the wall has been determined, using a large plane-parallel ionization chamber with exchangeable front and back walls. The results show that in many commercial chambers there is an energy dependent pwall factor, mainly due to differences in backscatter from the often thick chamber body as compared to the phantom material. Backscatter in common phantom and chamber materials may differ by as much as 2% at low electron energies (Plastic Water as compared to polystyrene). The front walls are often thin, resulting in negligible perturbation, but the 0.5 mm front wall of graphite in the NACP chamber was found to increase the response by 0.7% in a PMMA phantom. The experimental results have been compared with EGS4 Monte Carlo calculations using the DOSRZ code. There is an agreement within statistical and experimental uncertainties (0.5%) indicating that it is possible to use Monte Carlo calculations to calculate perturbation factors with good accuracy.

Graphite↗

Detour factors in water and plastic phantoms and their use for range and depth scaling in electron-beam dosimetry.

Average penetration depths and detour factors of 1-50 MeV electrons in water and plastic materials have been computed by means of analytical calculation, within the continuous-slowing-down approximation and including multiple scattering, and using the Monte Carlo codes ITS and PENELOPE. Results are compared to detour factors from alternative definitions previously proposed in the literature. Different procedures used in low-energy electron-beam dosimetry to convert ranges and depths measured in plastic phantoms into water-equivalent ranges and depths are analysed. A new simple and accurate scaling method, based on Monte Carlo-derived ratios of average electron penetration depths and thus incorporating the effect of multiple scattering, is presented. Data are given for most plastics used in electron-beam dosimetry together with a fit which extends the method to any other low-Z plastic material. A study of scaled depth-dose curves and mean energies as a function of depth for some plastics of common usage shows that the method improves the consistency and results of other scaling procedures in dosimetry with electron beams at therapeutic energies.

Electrons↗

Bremsstrahlung production at 50 MeV in different target materials and configurations.

A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transport through the treatment head of an MM5O racetrack microtron and a water phantom, have been compared to experimental dose profiles from narrow photon beams at 10-cm depth in water. A reduction in the ITS 3.0 default substep size has been found necessary even for incomplete agreement, in consistency with the findings of Faddegon and Rogers [Nucl. Instrum. Meth. A 327, 556-565 (1993)] for a different experimental setup and energy using the previous version of ITS. Results show that the calculated shape of the tail of dose distributions from narrow photon beams agrees well with measurements, but CYLTRAN/ITS 3.0 fails to reproduce the central part of the distribution. The discrepancy at small angles, reported previously for EGS4 and ITS 2.1 simulations, possess a limitation to Monte Carlo simulations of narrow photon beams used in scanned systems of clinical accelerators. Radial dose profiles have been calculated by convolution of the energy fluence at the exit of the target with one polyenergetic Monte Carlo calculated dose kernel and also a database consisting of ten different dose kernels corresponding to different monoenergetic photon pencil beams for comparison. The agreement with the much slower fully detailed Monte Carlo calculations was better when using the database kernels than the polyenergetic kernel. Results for the mean energy, mean polar angle, and energy fluence at different depths within various targets have been obtained. These are discussed in the context of the design characteristics of bremsstrahlung targets with emphasis on their utilization for scanning photon beam techniques.

Biophysical Phenomena↗

An improved energy-range relationship for high-energy electron beams based on multiple accurate experimental and Monte Carlo data sets.

A theoretically based analytical energy-range relationship has been developed and calibrated against well established experimental and Monte Carlo calculated energy-range data. Only published experimental data with a clear statement of accuracy and method of evaluation have been used. Besides published experimental range data for different uniform media, new accurate experimental data on the practical range of high-energy electron beams in water for the energy range 10-50 MeV from accurately calibrated racetrack microtrons have been used. Largely due to the simultaneous pooling of accurate experimental and Monte Carlo data for different materials, the fit has resulted in an increased accuracy of the resultant energy-range relationship, particularly at high energies. Up to date Monte Carlo data from the latest versions of the codes ITS3 and EGS4 for absorbers of atomic numbers between four and 92 (Be, C, H2O, PMMA, Al, Cu, Ag, Pb and U) and incident electron energies between 1 and 100 MeV have been used as a complement where experimental data are sparse or missing. The standard deviation of the experimental data relative to the new relation is slightly larger than that of the Monte Carlo data. This is partly due to the fact that theoretically based stopping and scattering cross-sections are used both to account for the material dependence of the analytical energy-range formula and to calculate ranges with the Monte Carlo programs. For water the deviation from the traditional energy-range relation of ICRU Report 35 is only 0.5% at 20 MeV but as high as -2.2% at 50 MeV. An improved method for divergence and ionization correction in high-energy electron beams has also been developed to enable use of a wider range of experimental results.

Electrons↗

Ionization chamber dosimetry of proton beams using cylindrical and plane parallel chambers. Nw versus Nk ion chamber calibrations.

Determinations of the absorbed dose in a 170 MeV proton beam have been performed using seven ionization chambers of different types: five cylindrical (two FWT IC-18 and three NE-2571, of which one was modified to have the central electrode made of graphite) and two plane parallel (NACP-02 and Roos FK-6). The ionization was converted into absorbed dose in the proton beam according to the generalization of the formalism provided by the IAEA Code of Practice (TRS 277), which enables the use of the same equations for all kinds of beam used in radiotherapy. The absorbed dose obtained with the two IC-18 chambers, a chamber type commonly used as a reference in proton beams, was up to 1.5% lower than that obtained with the Farmer NE-2571 chamber, which was used as the reference in this work when calibration factors in terms of NK were used. To investigate this difference, experimental ND factors for six chambers (the two IC-18 chambers, the NACP-02, the FK-6 and two of the NE-2571 chambers) were determined in a high-energy electron beam. The procedure commonly recommended for plane parallel ion chambers was used for all the chambers, using the same reference chamber, a Farmer NE-2571. In the 170 MeV proton beam all the ND factors yielded consistent absorbed dose determinations within the estimated experimental uncertainties. This finding calls into question the value of the product kattkm for the IC-18 chamber given by the IAEA Code of Practice used in this comparison, and points at possible chamber to chamber variations that theoretical kattkm factors cannot predict. The investigations enabled the determination of the Pwall(60Co) factor of the Roos FK-6 plane parallel chamber, yielding 1.003 +/- 0.5%, and a correction for the effect of the aluminium central electrode of NE-2571 chambers in proton beams, equal to 1.003 +/- 0.4%. Two of the chambers (the plane parallel FK-6 and the modified cylindrical NE-2571) were provided with calibration factors in terms of absorbed dose to water, Nw, at the quality of 60Co by the Primary Standard Dosimetry Laboratory in Germany (PTB). Using the Nw formalism excellent agreement was found with the determination based on the experimental ND, giving support to the implementation of the NW procedure in therapeutic proton beams.

Humans↗

The status of high-energy photon and electron beam dosimetry five years after the implementation of the IAEA Code of Practice in the Nordic countries.

The status of the dosimetry of high-energy photon and electron beams is analysed, taking into account the main developments in the field since the implementation of the IAEA Code of Practice in the Nordic countries. In electron beam dosimetry, energy-range relationships are discussed; Monte-Carlo results with different codes are compared with the experimentally derived empirical expression used in most protocols. Updated calculations of water-to-air stopping-power ratios following the changes in the Monte-Carlo code used to compute actual Sw,air values are compared with the data included in most dosimetry protocols. The validity of the commonly used procedure to select stopping-power ratios for a clinical beam from the mean energy at the phantom surface and the depth of measurement, is analysed for 'realistic' electron beams. In photon beam dosimetry, calculated correction factors including the effect of the wall plus waterproofing sleeve and existing data on the shift of the effective point of measurement of an ionization chamber, are discussed. New calculations of medium-to-air stopping-power ratios and their correlation with the quality of the beam obtained from the convolution of Monte-Carlo kernels are presented together with their possible practical implications in dosimetry. Trends in Primary Standard Dosimetry Laboratories towards implementing calibrations in terms of absorbed dose to water are presented, emphasizing controversial proposals for the specification of photon beam qualities. Plane-parallel ionization chambers are discussed regarding aspects that affect determinations of absorbed dose, either through the different methods used for the calibration of these chambers or by means of correction factors. Recent studies on the effect of the central electrode in Farmer-type cylindrical chambers are described.

Monte Carlo Method↗

On the calibration of plane-parallel ionization chambers for electron beam dosimetry.

The procedure recommended by different dosimetry protocols for the determination of the absorbed dose to air chamber factor, ND,pp, of plane-parallel chambers, comparing absorbed dose determinations in a high-energy electron beam with a reference cylindrical chamber having a known ND,cyl factor, has been investigated. Attention has been focused on the case that the chamber serving as reference has a solid aluminium central electrode. It has been found that using a wide spread Farmer-type chamber (NE 2571), together with recommendations which specifically take into account central electrode corrections for electron beam dosimetry, kcelpcel = pcel-global(IAEA) = 1.008, yields inconsistent results compared with those obtained from a fully homogeneous ionization chamber; for the NE 2571 chamber, a value kcelpcel = pcel-global(IAEA) congruent to 1.0 has been obtained. Analytical calculations of kmkatt for Farmer-type cylindrical chambers and experimental determinations of the product kmkattkcelpcel in electron beams agree within experimental uncertainties, with no evidence of statistical significance for the commonly used assumption pcel = 1, which yields a 0.8% correction (due to kcel only) for the effect of the NE 2571 aluminium electrode in electron beam dosimetry. The use of a 'NACP-chamber' specific factor (kpp or kmkatt) to obtain ND,pp from NK,pp in NACP plane-parallel chambers has been found unsatisfactory, and direct experimental determinations of ND,pp are recommended instead. It is suggested that Standard Dosimetry Laboratories provide ND,pp calibration factors in 60Co beams.

Calibration↗

Uncertainties in dosimetric data and beam calibration.

Recent studies indicate that the calibration of therapeutic beams is one of the main sources of uncertainty in the mean absorbed dose to the target volume in radiotherapy. Interaction coefficients and data used through the different steps in the calibration are pointed out as the main contribution to this uncertainty. Procedures used to select dosimetric data, that is, input parameters used in the specification of the quality of the beam, cause another contribution. In this paper the actual status of the data used for the dosimetry of photon and electron beams is introduced first. Uncertainties along the dosimetric chain are analyzed according to the procedure and data used in recent publications. Uncertainties in stopping-power ratios, considered the main contribution, are discussed in detail starting from the basic electron stopping-power data. Overall uncertainties in the presently available set of stopping-power ratios are analyzed. Recent developments in the dosimetry of electron beams, related to the effect of energy and angular spread and electron and photon contamination, are discussed in connection with the procedure to select stopping-power ratios for clinical dosimetry. Uncertainties along the dosimetric chain are evaluated in terms of the present knowledge of error sources.

Calibration↗

Determination of effective bremsstrahlung spectra and electron contamination for photon dose calculations.

A method is described for determining an effective, depth dose consistent bremsstrahlung spectra for high-energy photon beams using depth dose curves measured in water. A simple, analytical model with three parameters together with the nominal accelerating potential is used to characterise the bremsstrahlung spectra. The model is used to compute weights for depth dose curves from monoenergetic photons. These monoenergetic depth doses, calculated with the convolution method from Monte Carlo generated point spread functions (PSF), are added to yield the pure photon depth dose distribution. The parameters of the analytical spectrum model are determined using an iterative technique to minimise the difference between calculated and measured depth dose curves. The influence from contaminant electrons is determined from the difference between the calculated and the measured depth dose.

Computer Simulation↗

Recent developments in basic dosimetry.

CCEMRI(I) (1985) has recommended that from January 1st 1986 the Primary Standard Dosimetry Laboratories (PSDLs) should adopt new values for W/e (33.97 J/C), stopping powers for electrons (ICRU Report 37, 1984), g value in air for 60Co (3.2 X 10-3), and energy absorption coefficients [17]. The consistency of the whole dosimetric chain requires the same basic physical data at the users' beam quality and PSDLs, but most of the existing dosimetry protocols are not generally based on such a set of data and in some cases old and new data have been employed together. A review of the basic data included in the dosimetry protocols is presented here, together with a comparison with experimental data. The most recent data include the recommendations of CCEMRI(I) and at the same time, some of the inconsistencies existing in dosimetry protocol have been eliminated. The new set of data is presented in this work. New dosimetry protocols and updated versions of protocols published before 1986 are discussed in terms of their basic data.

Clinical Protocols↗

Chamber-dependent wall correction factors in dosimetry.

The calculation of the response of ionisation chambers to different photon beam qualities used in radiotherapy requires electron stopping-power data. These data have recently been revised and are used here to derive a consistent set of correction factors for ionisation chambers of different wall and build-up cap composition. Theoretically derived parameters km and katt which relate the exposure calibration of an ionisation chamber to the absorbed dose to the air of the cavity, are compared with the experimentally derived product kmkatt showing generally good agreement but also significant discrepancies for plastic-walled chambers with inner graphite coatings. A table of km values is given for a large number of commercial ionisation chambers. The new stopping-power data are also used to evaluate the wall-dependent correction factor (pwall) that enters into the determination of the absorbed dose to water in photon beams, results being given as a function of the quality of the beam. Our theoretical calculations of pwall are consistent with existing experimental data.

Cobalt Radioisotopes↗

Stopping power data for high-energy photon beams.

Spencer-Attix stopping power ratios for the dosimetry of high-energy photon beams used in radiation therapy have been calculated using the Monte Carlo method. The stopping power ratios are calculated in a more consistent way than previously and are given as a function of the attenuation properties of the beam. The dependence of the stopping power ratio on the electron contamination of the beam as well as on depth and field size has also been investigated. Results are compared with stopping power ratios recommended in different dosimetry protocols and to experimental results. The agreement with most dosimetry protocols is within about one per cent and with recent experimental data is better than half a per cent.

Evaluation Studies as Topic↗