Stopping-power ratio for a photon spectrum as a weighted sum of the values for monoenergetic photon beams.

Stopping-power ratios for water to air, Sw,air, have been calculated for 60Co and thin-target bremsstrahlung beams. The Monte Carlo method was used to generate depth-dependent Sw,air values and depth-absorbed-dose distributions in water for monoenergetic photon beams covering the energy range 0.1-50 MeV. An averaging procedure has been developed to derive the stopping-power ratios for a photon spectrum from the monoenergetic data. Values of the Spencer-Attix ratio for delta = 10 keV, SSAw,air (delta = 10 keV), and the Bragg-Gray ratio, SBGw,air, evaluated using the new I values and two different sets of values for the density effect correction, are given at the reference depths recommended in the dosimetry protocols.

Humans↗

Fluence and absorbed dose in high energy electron beams.

The depth dependence of fluence, vectorial and planar fluence, energy fluence, vectorial and planar energy fluence and absorbed dose has been calculated in 5 and 20 MeV electron beams in water. The shape of these distributions has been compared with analytic expressions for fluence and absorbed dose and the general mechanisms governing the shape of the depth dose curve have been explained. In particular it is demonstrated that the depth dependence of planar energy fluence and mean energy is very similar, and so is the case for fluence and absorbed dose and primary fluence and absorbed dose from primaries with inclusion of fast secondaries. The results are useful for dosimetry and dose planning in high energy electron beams.

Computers↗

Electron beam dose planning using Gaussian beams. Improved radial dose profiles.

The Gaussian solution of the transport equation for electrons in a medium omits the large angle single scattering events. These events have been included by using Monte Carlo calculated radial dose profiles for point monodirectional beams. A sum of three Gaussian functions with different relative weights and widths have been fitted to the Monte Carlo calculated radial dose profiles. These profiles have been confirmed by measurements in an almost point monodirectional beam, and the importance of an adequate experimental set-up for determination of radial dose profiles is discussed. The analytic treatment when using three different functions in the Gaussian formalism is presented. Central axis depth dose curves for 10 MeV and 20 MeV have finally been calculated and compared with depth dose curves calculated using Monte Carlo technique and a single Gaussian function. Considerable errors (20-30%) result with the single Gaussian function at small field sizes whereas three components give good agreement with the Monte Carlo method.

Computers↗

Electron beam dose planning using discrete Gaussian beams. Mathematical background.

A general method for computerized electron beam dose planning is proposed based on the use of a square or hexagonal grid or matrix of discrete Gaussian elementary beams. Using this method the distribution of absorbed dose in an electron beam of arbitrary cross-section incident on an irregular patient surface can be calculated taking the influence of tissue inhomogeneities into account. The derived expressions for the absorbed dose in narrow and broad uniform beams are compared with experimental data and Monte Carlo calculations. Good agreement is obtained over the clinically significant portion of the absorbed dose distribution at a fairly wide grid spacing of about 0.5 cm.

Computers↗

Mean energy in electron beams.

The mean energy of the energy spectrum is an essential parameter for the dosimetry of therapeutic electron beams. Frequently it is assumed that the mean energy of such beams remains constant across the beam and only its degradation with depth is considered. The present work analyzes the variation of the mean energy of primary electrons with depth and lateral position in an electron beam using the Monte Carlo method. Results are compared with relations commonly employed for determination of mean energy at a depth. For the variation of the mean electron energy with depth in broad beams, good agreement was found between Monte Carlo results and an analytic continuous slowing down expression, which takes the variation of radiation stopping power with depth into account. Due to the calculated lateral variation of the mean energy, the relative absorbed dose profile determined with an air ionization chamber in a clinical beam should differ by less than 1% from the measured ionization profile.

Computers↗

A study of interface effects in 60Co beams using a thin-walled parallel plate ionization chamber.

A large plane-parallel ionization chamber has been constructed to investigate interface effects in 60Co beam. The designed geometry yields negligible perturbation from the side walls, as opposed to the large effects existing in commercially available plane-parallel chambers. The chamber has been used to investigate interface phenomena in transition zones using a wide range of elements (Z = 4-82) as front- and back-scattering media and a clinically relevant 60Co gamma-ray field size. The effects of varying the chamber height discretely (0.5-11 mm) and increasing the wall thickness (1-9 mg/cm2) have been investigated. The variation of the measured ionization with the experimental setup (air gap between backscatter material and chamber wall, measurements at dmax and at 5-cm depth, varying the material both in front of and behind the chamber, etc.) has also been investigated. The simple geometry of the ion chamber has been found optimum for benchmark studies of Monte Carlo calculations. The ion chamber is suited for investigating experimentally the effects of varying transport parameters used in Monte Carlo simulations. The results presented show that the complex physical mechanisms governing 60Co interface dosimetry still make Monte Carlo condensed-history (macroscopic) techniques uncertain. It has been found that the EGS4 Monte Carlo system, together with the user code DOSRZ V4.0 and the PRESTA algorithm, yields good agreement with experiments for low and medium Z (main interest in dosimetry and radiotherapy), but may underestimate up to 10% the backscatter from high-Z materials even when transport parameters are optimized.

Algorithms↗

Constraints of the multiple-scattering theory of Molière in Monte Carlo simulations of the transport of charged particles.

The breakdown of Molière's multiple-scattering theory for short pathlengths occurring during Monte Carlo simulations with charged particles is demonstrated. It has been found that in certain conditions where the theory is assumed to be valid, significant distortions of the angular distribution occur that make the sampling of the polar angle questionable in numerous steps of Monte Carlo simulations. The limits of the theory have been investigated, both using a large number of terms in the Molière's series and using steps of Molière's theory where 1/B expansions are not involved. At B = 4.5 the commonly accepted 3-term series expansion yields differences up to +/- 6% compared with the evaluation of the complete Molière angular distribution, and up to 7 terms in the series are needed in order to achieve agreement within +/- 2%. One percent agreement requires B = 10. Numerical values of the full distribution are given in terms of Molière's parameters B and reduced angle theta. By using the general dependence of the distribution results are valid for both electron and proton Monte Carlo simulations in any material.

Biophysical Phenomena↗

Dosimetry and quality specification of high energy photon beams.

A number of quality descriptors are defined characterizing the photon attenuation and lepton contamination properties of high energy photon beams for radiation therapy. The dependence of the quality parameters on the design of the clinical beams such as the incident electron energy, target and filter thicknesses, field size and depth in the phantom are analyzed in some detail using analytical and Monte Carlo techniques. It is shown that the mean attenuation coefficient of the beam for a standard field size of 10 cm X 10 cm is related very accurately to the mean stopping power ratio for ionizing chamber dosimetry but also approximately to the equilibrium absorbed dose in the beam for a given photon energy fluence. This means that accurate photon dosimetry can be performed without knowing the acceleration potential, target design or filter thickness for the beam in use. Furthermore, the mechanism behind beam hardening and softening in the phantom are quantitized and suitable quality parameters for the lepton contamination are identified. The latter allow a determination of the lepton contamination for correction of the stopping power ratio near the surface if the contamination is large.

Monte Carlo Method↗

Calculation and application of point spread functions for treatment planning with high energy photon beams.

A general dose calculation method for treatment planning with high energy photon beams, based on folding of the total energy released by primary photons per unit mass, the terma, with a fractional mean energy imparted point spread function is described. A set of point spread functions has been calculated with Monte Carlo technique for energies of primary photons between 100 keV and 20 MeV. Dose distributions have been calculated for a 6 MV bean using the method. The results clearly point out the considerably increased precision and flexibility achieved when calculating photon beam dose distributions from first principles using Monte Carlo generated point spread functions. The point spread functions calculated in this work are available on magnetic tape from the authors.

Humans↗