RF pulse concatenation for spatially selective inversion

It is shown that spatially selective inversion and saturation can be achieved by concatenation of RF pulses with lower flip angles. A concatenation rule which enables global doubling of the flip angle of any given excitation pulse applied to initial z magnetization is proposed. In this fashion, the selectivity of the single pulse is preserved, making the high selectivity achievable in the low flip-angle regime available for inversion and large flip-angle saturation purposes. The profile quality achievable with exemplary concatenated pulses is investigated in comparison with adiabatic inversion. It is verified that by using concatenated inversion in the transfer insensitive labeling technique (TILT), the MT artifact is suppressed. Copyright 2000 Academic Press.

Journal Article↗

Assessment of prosthetic aortic valve performance by magnetic resonance velocity imaging.

OBJECTIVES: Magnetic resonance (MRI) velocity mapping was used to evaluate non-invasively the flow profiles of the ascending aorta in normal volunteers and in patients with an aortic (mechanical) valve prosthesis. BACKGROUND: In patients with artificial aortic valves the flow profile in the ascending aorta is severely altered. These changes have been associated with an increased risk of thrombus formation and mechanical hemolysis. METHODS: Velocity profiles were determined 30 mm distal to the aortic valve in six healthy volunteers and seven patients with aortic valve replacement (replacement within the last 2 years) using ECG triggered phase contrast MRI. Peak flow, mean flow and mean reverse flow were measured in intervals of 25 ms during the entire heart cycle. Systolic reverse flow, end-systolic closing and diastolic leakage volume were calculated for all subjects. RESULTS: Peak flow velocity during mid-systole was significantly higher in patients with valvular prosthesis than in normals (mean + SD, 1.9 +/- 0.4 m/s vs. 1.2 +/- 0.03 m/s, P < 0.001) with a double peak and a zone of reversed flow close to the inner (left lateral) wall of the ascending aorta of the patients. Closing volume was significantly larger in patients than in controls (-3.3 +/- 1.2 ml/beat vs. -0.9 +/- 0.5 ml/beat; P < 0.001). There was reverse flow during systole in valvular patients amounting to 15.7 +/- 6.7% of total cardiac output compared to 2.3 +/- 1.2% in controls (P < 0.001). Diastolic mean flow was negative in patients after valve replacement but not in controls (-11.0 +/- 15.2 ml/beat vs. 6.8 +/- 3.2 ml/beat; P < 0.01). CONCLUSIONS: The following three major quantitative observations have been made in the present study: (1) Mechanical valve prostheses have an increased peak flow velocity with a systolic reverse flow at the inner (left lateral) wall of the ascending aorta. (2) A double peak flow velocity pattern can be observed in patients with bileaflet (mechanical) prosthesis. (3) The blood volume required for leaflet closure and the diastolic leakage blood volume are significantly higher for the examined bileaflet valve than for native heart valves.

Adult↗

Dynamic characteristics of oxygenation-sensitive MRI signal in different temporal protocols for imaging human brain activity.

The temporal characteristics of cerebral blood oxygenation during human brain activation were monitored with dynamic echo-planar imaging (EPI) using the blood oxygenation level dependent (BOLD) fMRI. We investigated oxygenation-sensitive signal changes: 1. during repetitive block stimuli, to determine the latency of the activation-induced signal change in the primary visual cortex; 2. on shortening the rest periods between constant stimulated phases, to investigate the limitations that this latency poses in temporal resolution of the technique; and 3. on sustained steady-state stimulation, to characterise oxygenation changes during prolonged brain activation using different stimuli. Delayed intrinsic haemodynamic response and a finite signal-to-noise ratio limit the temporal resolution achieved with BOLD fMRI. Separate activation periods were resolved when the delay between consecutive stimulations was at least 2 s. In this study oxygenation remained elevated throughout sustained activation, suggesting a constant rate of oxygen consumption by the primary cortical neurones during activation. Characterisation of fMRI signal dynamics in dynamic temporal protocols is significant both in terms of optimising stimulation protocols and the potential to gain insight into the physiological mechanisms underlying neuronal activation which could increase the clinical applicability of the technique.

Adult↗

Hemodynamics in the carotid artery bifurcation: a comparison between numerical simulations and in vitro MRI measurements.

The presence of atherosclerotic plaques has been shown to be closely related to the vessel geometry. Studies on postmortem human arteries and on the experimental animal show positive correlation between the presence of plaque thickness and low shear stress, departure of unidirectional flow and regions of flow separation and recirculation. Numerical simulations of arterial blood flow and direct blood flow velocity measurements by magnetic resonance imaging (MRI) are two approaches for the assessment of arterial blood flow patterns. In order to verify that both approaches give equivalent results magnetic resonance velocity data measured in a compliant anatomical carotid bifurcation model were compared to the results of numerical simulations performed for a corresponding computational vessel model. Cross sectional axial velocity profiles were calculated and measured for the midsinus and endsinus internal carotid artery. At both locations a skewed velocity profile with slow velocities at the outer vessel wall, medium velocities at the side walls and high velocities at the flow divider (inner) wall were observed. Qualitative comparison of the axial velocity patterns revealed no significant differences between simulations and in vitro measurements. Even quantitative differences such as for axial peak flow velocities were less than 10%. Secondary flow patterns revealed some minor differences concerning the form of the vortices but maximum circumferential velocities were in the same range for both methods.

Animals↗

Schizophrenia: glutathione deficit in cerebrospinal fluid and prefrontal cortex in vivo.

Schizophrenia is a major psychiatric disease, which affects the centre of the personality, with severe problems of perception, cognition as well as affective and social behaviour. In cerebrospinal fluid of drug-free schizophrenic patients, a significant decrease in the level of total glutathione (GSH) by 27% (P<0.05) was observed as compared to controls, in keeping with the reported reduced level of its metabolite gamma-glutamylglutamine. With a new non-invasive proton magnetic resonance spectroscopy methodology, GSH level in medial prefrontal cortex of schizophrenic patients was found to be 52% (P = 0.0012) lower than in controls. GSH plays a fundamental role in protecting cells from damage by reactive oxygen species generated among others by the metabolism of dopamine. A deficit in GSH would lead to degenerative processes in the surrounding of dopaminergic terminals resulting in loss of connectivity. GSH also potentiates the N-methyl-D-aspartate (NMDA) receptor response to glutamate, an effect presumably reduced by a GSH deficit, leading to a situation similar to the application of phencyclidine (PCP). Thus, a GSH hypothesis might integrate many established biological aspects of schizophrenia.

Adolescent↗

Cardiac rotation and relaxation in patients with aortic valve stenosis.

BACKGROUND: Diastolic dysfunction with delayed relaxation and abnormal passive elastic properties has been described in patients with severe pressure overload hypertrophy. The purpose of this study was to evaluate the time course of rotational motion of the left ventricle in patients with aortic valve stenosis using myocardial tagging. METHODS: Myocardial tagging is a non-invasive method based on magnetic resonance which makes it possible to label ('tag') specific myocardial regions. From the motion of the tag's cardiac rotation, radial displacement and translational motion can be determined. In 12 controls and 13 patients with severe aortic valve stenosis systolic and diastolic wall motion was assessed in an apical and basal short axis plane. RESULTS: The normal left ventricle performs a systolic wringing motion around the ventricular long axis with clockwise rotation at the base (-4.4+/-1.6 degrees) and counter-clockwise rotation at the apex (+6.8+/-2.5 degrees) when viewed from the apex. During early diastole an untwisting motion can be observed which precedes diastolic filling. In patients with aortic valve stenosis systolic rotation is reduced at the base (-2.4+/-2.0 degrees; P<0.01) but increased at the apex (+12.0+/-6.0 degrees; P<0.05). Diastolic untwisting is delayed and prolonged with a decrease in normalized rotation velocity (-6.9+/-1.1 s(-1)) when compared to controls (-10.7+/-2.2 s(-1); P<0.001). Maximal systolic torsion is 8.0+/-2.1 degrees in controls and 14.1+/-6.4 degrees (P<0.01) in patients with aortic valve stenosis. CONCLUSIONS: Left ventricular pressure overload hypertrophy is associated with a reduction in basal and an increase in apical rotation resulting in increased torsion of the ventricle. Diastolic untwisting is delayed and prolonged. This may explain the occurrence of diastolic dysfunction in patients with severe pressure overload hypertrophy.

Adult↗

Cardiac rotation and relaxation after anterolateral myocardial infarction.

BACKGROUND: Both systolic and diastolic dysfunction have been observed in patients with anterolateral myocardial infarction. Diastolic dysfunction is related to disturbances in relaxation and diastolic filling. OBJECTIVE: To analyse cardiac rotation, regional shortening and diastolic relaxation in patients with anterolateral infarction. METHODS: Cardiac rotation and relaxation in controls and patients with chronic anterolateral infarction were assessed by myocardial tagging. Myocardial tagging is based on magnetic resonance imaging and allows us to label specific myocardial regions for imaging cardiac motion (rotation, translation and radial displacement). A rectangular grid was placed on the myocardium (basal, equatorial and apical short-axis plane) of each of 18 patients with chronic anterolateral infarction and 13 controls. Cardiac rotation, change in area and shortening of circumference were determined in each case. RESULTS: The left ventricle in controls performs a systolic wringing motion with a clockwise rotation at the base and a counterclockwise rotation at the apex when viewed from the apex. During relaxation a rotational motion in the opposite direction (namely untwisting) can be observed. In patients with anterolateral infarction, there is less systolic rotation at the apex and diastolic untwisting is delayed and prolonged in comparison with controls. In the presence of a left ventricular aneurysm (n = 4) apical rotation is completely lost. There is less shortening of circumference in infarcted and remote regions. CONCLUSIONS: The wringing motion of the myocardium might be an important mechanism involved in maintaining normal cardiac function with minimal expenditure of energy. This mechanism no longer operates in patients with left ventricular aneurysms and operates significantly less than normal in those with anterolateral hypokinaesia. Diastolic untwisting is significantly delayed and prolonged in patients with anterolateral infarction, which could explain the occurrence of diastolic dysfunction in these patients.

Aged↗

Relative contributions of "pressure pump" and "peristaltic pump" to gastric emptying.

The relative contributions to gastric emptying from common cavity antroduodenal pressure difference ("pressure pump") vs. propagating high-pressure waves in the distal antrum ("peristaltic pump") were analyzed in humans by high-resolution manometry concurrently with time-resolved three-dimensional magnetic resonance imaging during intraduodenal nutrient infusion at 2 kcal/min. Gastric volume, space-time pressure, and contraction wave histories in the antropyloroduodenal region were measured in seven healthy subjects. The subjects fell into two distinct groups with an order of magnitude difference in levels of antral pressure activity. However, there was no significant difference in average rate of gastric emptying between the two groups. Antral pressure history was separated into "propagating high-pressure events" (HPE), "nonpropagating HPEs," and "quiescent periods." Quiescent periods dominated, and average pressure during quiescent periods remained unchanged with decreasing gastric volume, suggesting that common cavity pressure levels were maintained by increasing wall muscle tone with decreasing volume. When propagating HPEs moved to within 2-3 cm of the pylorus, pyloric resistance was found statistically to increase with decreasing distance between peristaltic waves and the pylorus. We conclude that transpyloric flow tends to be blocked when antral contraction waves are within a "zone of influence" proximal to the pylorus, suggesting physiological coordination between pyloric and antral contractile activity. We further conclude that gastric emptying of nutrient liquids is primarily through the "pressure pump" mechanism controlled by pyloric opening during periods of relative quiescence in antral contractile wave activity.

Adult↗

Low-cost MR-compatible moving heart phantom.

For the development and evaluation of cardiac magnetic resonance (MR) imaging sequences and methodologies, the availability of a periodically moving phantom to model respiratory and cardiac motion would be of substantial benefit. Given the specific physical boundary conditions in an MR environment, the choice of materials and power source of such phantoms is heavily restricted. Sophisticated commercial solutions are available; however, they are often relatively costly and user-specific modifications may not easily be implemented. We therefore sought to construct a low-cost MR-compatible motion phantom that could be easily reproduced and had design flexibility. A commercially available K'NEX construction set (Hyper Space Training Tower, K'NEX Industries, Inc., Hatfield, PA) was used to construct a periodically moving phantom head. The phantom head performs a translation with a superimposed rotation, driven by a motor over a 2-m rigid rod. To synchronize the MR data acquisition with phantom motion (without introducing radiofrequency-related image artifacts), a fiberoptic control unit generates periodic trigger pulses synchronized to the phantom motion. Total material costs of the phantom are US$ < 200.00, and a total of 80 man-hours were required to design and construct the original phantom. With schematics of the present solution, the phantom reproduction may be achieved in approximately 15 man-hours. The presented MR-compatible periodically moving phantom can easily be reproduced, and user-specific modifications may be implemented. Such an approach allows a detailed investigation of motion-related phenomena in MR images.

Artifacts↗

Alterations in the local myocardial motion pattern in patients suffering from pressure overload due to aortic stenosis.

BACKGROUND: MR tissue tagging allows the noninvasive assessment of the locally and temporally resolved motion pattern of the left ventricle. Alterations in cardiac torsion and diastolic relaxation of the left ventricle were studied in patients with aortic stenosis and were compared with those of healthy control subjects and championship rowers with physiological volume-overload hypertrophy. METHODS AND RESULTS: Twelve aortic stenosis patients, 11 healthy control subjects with normal left ventricular function, and 11 world-championship rowers were investigated for systolic and diastolic heart wall motion on a basal and an apical level of the myocardium. Systolic torsion and untwisting during diastole were examined by use of a novel tagging technique (CSPAMM) that provides access to systolic and diastolic motion data. In the healthy heart, the left ventricle performs a systolic wringing motion, with a counterclockwise rotation at the apex and a clockwise rotation at the base. Apical untwisting precedes diastolic filling. In the athlete's heart, torsion and untwisting remain unchanged compared with those of the control subjects. In aortic stenosis patients, torsion is significantly increased and diastolic apical untwisting is prolonged compared with those of control subjects or athletes. CONCLUSIONS: Torsional behavior as observed in pressure- and volume-overloaded hearts is consistent with current theoretical findings. A delayed diastolic untwisting in the pressure-overloaded hearts of the patients may contribute to a tendency toward diastolic dysfunction.

Adult↗

Assessment of gastric motor function during the emptying of solid and liquid meals in humans by MRI.

Gastric emptying and motility have previously been assessed by magnetic resonance imaging (MRI) using liquid test meals. The aim of this study was to extend the applicability of our MRI method to the assessment of gastric emptying and motility of solid meals. Gastric emptying and motility of a liquid and a solid meal, of similar chemical properties, were studied in eight volunteers. The MRI protocol combined a multislice turbo spin-echo (TSE) sequence (volume scan, resolution: 1.5 mm) and a dynamic FFE sequence (motility scan, 1 sec/image, resolution: 3.1 mm). Gastric emptying of the liquid meal was faster than emptying of the solid meal when considering half-times of emptying. However, during the first 15 minutes after ingestion, the liquid meal emptied more slowly. This was related to reduced motility with the liquid meal. In conclusion, with our MRI method it is feasible to assess gastric emptying and motility of liquid and solid meals.

Adult↗

Transfer insensitive labeling technique (TILT): application to multislice functional perfusion imaging.

Cerebral blood flow can be studied in a multislice mode with a recently proposed perfusion sequence using inversion of water spins as an endogenous tracer without magnetization transfer artifacts. The magnetization transfer insensitive labeling technique (TILT) has been used for mapping blood flow changes at a microvascular level under motor activation in a multislice mode. In TILT, perfusion mapping is achieved by subtraction of a perfusion-sensitized image from a control image. Perfusion weighting is accomplished by proximal blood labeling using two 90 degrees radiofrequency excitation pulses. For control preparation the labeling pulses are modified such that they have no net effect on blood water magnetization. The percentage of blood flow change, as well as its spatial extent, has been studied in single and multislice modes with varying delays between labeling and imaging. The average perfusion signal change due to activation was 36.9 +/- 9.1% in the single-slice experiments and 38.1 +/- 7.9% in the multislice experiments. The volume of activated brain areas amounted to 1.51 +/- 0.95 cm3 in the contralateral primary motor (M1) area, 0.90 +/- 0.72 cc in the ipsilateral M1 area, 1.27 +/- 0.39 cm3 in the contralateral and 1.42 +/- 0.75 cm3 in the ipsilateral premotor areas, and 0.71 +/- 0.19 cm3 in the supplementary motor area.

Artifacts↗

Automatic vessel segmentation using active contours in cine phase contrast flow measurements.

The segmentation of images obtained by cine magnetic resonance (MR) phase contrast velocity mapping using manual or semi-automated methods is a time consuming and observer-dependent process that still hampers the use of flow quantification in a clinical setting. A fully automatic segmentation method based on active contour model algorithms for defining vessel boundaries has been developed. For segmentation, the phase image, in addition to the magnitude image, is used to address image distortions frequently seen in the magnitude image of disturbed flow fields. A modified definition for the active contour model is introduced to reduce the influence of missing or spurious edge information of the vessel wall. The method was evaluated on flow phantom data and on in vivo images acquired in the ascending aorta of humans. Phantom experiments resulted in an error of 0.8% in assessing the luminal area of a flow phantom equipped with an artificial heart valve. Blinded evaluation of the volume flow rates from automatic vs. manual segmentation of gradient echo (FFE) phase contrast images obtained in vivo resulted in a mean difference of -0.9 +/- 3%. The mean difference from automatic vs. manual segmentation of images acquired with a hybrid phase contrast sequence (TFEPI) within a single breath-hold was -0.9 +/- 6%.

Adult↗

Real-time interactive magnetic resonance imaging with multiple coils for the assessment of left ventricular function.

Interactive real-time examination of left ventricular function in healthy volunteers both under rest and stress conditions has been performed. For this purpose, a system combining an interactive user interface, an ultrafast segmented echo-planar imaging sequence, and real-time reconstruction and display of the acquired images was designed. Magnetic resonance images were acquired at rates of up to 20 images per second with multiple receiver coils. By using a sliding window reconstruction technique, reconstruction rates of up to 60 images per second were achieved with a latency of < 100 msec. The quality of the real-time images was evaluated both qualitatively and quantitatively and was found to be appropriate for the determination of left ventricular function. It is concluded that the combination of dedicated components provides a convenient modality for the high-quality visualization of left ventricular function under rest and stress conditions at video frame rates with magnetic resonance imaging. J. Magn. Reson. Imaging 1999;10:826-832.

Echo-Planar Imaging↗

Toward high-resolution myocardial tagging.

Magnetic resonance imaging with preceding tissue tagging is a robust method for assessing cardiac motion of the entire heartbeat cycle with a high degree of accuracy. One limitation of this technique, however, is the low resolution of the obtained displacement map of the labeled points within the myocardium. By a new tagging technique, which is based on the combination of two or more measurements of the same slice but with different grid positions, a highly improved resolution of cardiac motion data can be achieved. In combination with a multi-heart-phase echo-planar imaging sequence, such images with doubled grid frequency can be acquired in two short breath-hold periods.

Contrast Media↗

Detection of glutathione in the human brain in vivo by means of double quantum coherence filtering.

The feasibility of selective in vivo detection of glutathione (L-gamma-glutamyl-L-cysteinyl-glycine, GSH) in the human brain by means of (1)H magnetic resonance spectroscopy (MRS) at 1.5 T is demonstrated. A double quantum coherence (DQC) filtering sequence was used in combination with PRESS volume selection. The strongly coupled cysteinyl CH(2) compound of GSH was found to be the most suitable target for spectral editing. Analytical calculations employing a product operator description of the cysteinyl ABX three-spin system were made in order to optimize the inherent yield of the sequence. A pulse phase calibration procedure, which precedes the spectrum acquisition, secures maximal signal yield independently of the spatial localization of the volume of interest and thus comparability between individual examinations. In vitro tests show that the DQC filtering method provides good discrimination between the GSH signal at 2.9 ppm and the interfering resonances of creatine, gamma-aminobutyric acid (GABA) and aspartate. In measurements in the frontal lobe of 12 healthy volunteers a mean ratio of GSH signal to tissue water signal of 5.7 +/- 2.3 x 10(-5) was found, corresponding to a mean GSH tissue concentration of 2-5 mmol/L. The proposed technique allows for the detection of a biologically highly relevant metabolite at moderate field strength. Magn Reson Med 42:283-289, 1999.

Brain↗

Heart motion adapted cine phase-contrast flow measurements through the aortic valve.

A method for magnetic resonance cine velocity mapping through heart valves with adaptation of both slice offset and angulation according to the motion of the valvular plane of the heart is presented. By means of a subtractive labeling technique, basal myocardial markers are obtained and automatically extracted for quantification of heart motion at the valvular level. The captured excursion of the basal plane is used to calculate the slice offset and angulation of each required time frame for cine velocity mapping. Through-plane velocity offsets are corrected by subtracting velocities introduced by basal plane motion from the measured velocities. For evaluation of the method, flow measurements downstream from the aortic valve were performed both with and without slice adaptation in 11 healthy volunteers and in four patients with aortic regurgitation. Maximum through-plane motion at the aortic root level as calculated from the labeled markers averaged 8.9 mm in the volunteers and 6.5 mm in the patients. The left coronary root was visible in 2-4 (mean: 2.2) time frames during early diastole when imaging with a spatially fixed slice. Time frames obtained with slice adaptation did not contain the coronary roots. Motion correction increased the apparent regurgitant volume by 5.7 +/- 0.4 ml for patients with clinical aortic regurgitation, for an increase of approximately 50%. The proposed method provides flow measurements with correction for through-plane motion perpendicular to the aortic root between the valvular annulus and the coronary ostia throughout the cardiac cycle. Magn Reson Med 42:970-978, 1999.

Adult↗

Comparison of cerebral blood volume measured by near infrared spectroscopy and contrast enhanced magnetic resonance imaging.

Cerebral blood volume (CBV) can be quantified by both near infrared spectroscopy (NIRS) and magnetic resonance imaging (MRI). The aim is to compare CBV results obtained by NIRS and MRI in adult patients. 10 adult patients, 6 females and 4 males, age median 24 (range 21 to 76) years, were included in this study. All needed a MRI investigation with contrast medium for clinical reasons. The NIRS instrument, the Cerebral RedOx Monitor 2020 from Critikon, quantifies cerebral haemoglobin concentration using a sensor with two receiving channels at different distances. Geometrical detector arrangements of this type enable a ratio measurement to be achieved, which reduces the contribution of the skull and skin, thus allowing quantification. Cerebral haemoglobin concentration can be converted in CBV, as the haemoglobin concentration in the blood is known. CBV can be quantified by MRI using an indicator dilution method. The method requires an injection of a paramagnetic contrast agent. The input function can be measured at the throat and thus perfusion images can be quantified. CBV was measured by NIRS just before the patient entered the magnet and after he had left it. The sensor for the NIRS measurement was applied to the patients front three times for 1 minute to each side, avoiding the sinuses. CBV was determined by contrast enhanced MRI between the NIRS measurements. The mean CBV (NIRS) was 8.6 (SD 1.3) ml/100 g and CBV (MRI) was 7.1 (SD 2.5). The correlation between CBV (NIRS) and CBV (MRI) was Pearson's correlation coefficient -0.297 (p = 0.204) respectively Spearman's rho (nonparametric) -0.266 (p = 0.257). The CBV values obtained by NIRS and MRI, even though they are in the same range, do not correlate.

Adult↗