Aortic and mitral regurgitation: quantification using moving slice velocity mapping.

Comprehensive assessment of the severity of valvular insufficiency includes quantification of regurgitant volumes. Previous methods lack reliable slice positioning with respect to the valve and are prone to velocity offsets due to through-plane motion of the valvular plane of the heart. Recently, the moving slice velocity mapping technique was proposed. In this study, the technique was applied for quantification of mitral and aortic regurgitation. Time-efficient navigator-based respiratory artifact suppression was achieved by implementing a prospective k-space reordering scheme in conjunction with slice position correction. Twelve patients with aortic insufficiency and three patients with mitral insufficiency were studied. Aortic regurgitant volumes were calculated from diastolic velocities mapped with a moving slice 5 mm distal to the aortic valve annulus. Mitral regurgitant flow was indirectly assessed by measuring mitral inflow at the level of the mitral annulus and net aortic outflow. Regurgitant fractions, derived from velocity data corrected for through-plane motion, were compared to data without correction for through-plane motion. In patients with mild and moderate aortic regurgitation, regurgitant fractions differed by 60% and 15%, on average, when comparing corrected and uncorrected data, respectively. Differences in severe aortic regurgitation were less (7%). Due to the large orifice area of the mitral valve, differences were still substantial in moderate-to-severe mitral regurgitation (19%). The moving slice velocity mapping technique was successfully applied in patients with aortic and mitral regurgitation. The importance of correction for valvular through-plane motion is demonstrated.

Adult↗

Motion artifact reduction and vessel enhancement for free-breathing navigator-gated coronary MRA using 3D k-space reordering.

Breathing-induced bulk motion of the myocardium during data acquisition may cause severe image artifacts in coronary magnetic resonance angiography (MRA). Current motion compensation strategies include breath-holding or free-breathing MR navigator gating and tracking techniques. Navigator-based techniques have been further refined by the applications of sophisticated 2D k-space reordering techniques. A further improvement in image quality and a reduction of relative scanning duration may be expected from a 3D k-space reordering scheme. Therefore, a 3D k-space reordered acquisition scheme including a 3D navigator gated and corrected segmented k-space gradient echo imaging sequence for coronary MRA was implemented. This new zonal motion-adapted acquisition and reordering technique (ZMART) was developed on the basis of a numerical simulation of the Bloch equations. The technique was implemented on a commercial 1.5T MR system, and first phantom and in vivo experiments were performed. Consistent with the results of the theoretical findings, the results obtained in the phantom studies demonstrate a significant reduction of motion artifacts when compared to conventional (non-k-space reordered) gating techniques. Preliminary in vivo findings also compare favorably with the phantom experiments and theoretical considerations. Magn Reson Med 45:645-652, 2001.

Adult↗

Improved selectivity of double quantum coherence filtering for the detection of glutathione in the human brain in vivo.

An improved double quantum coherence (DQC) filter for the selective in vivo detection of glutathione (GSH) in the human brain at 1.5 Tesla is presented. The goal was to minimize contamination of the DQC-filtered GSH signal at 2.9 ppm with contributions arising from GABA. The modification consists of tailoring the frequency response of the read pulse, which converts DQC into anti-phase single quantum coherence in such a way that the GABA beta and gamma resonances at 3.0 and 1.9 ppm, respectively, remain unaffected. An implementation incorporating a Dante pulse train is used for in vitro tests as well as for in vivo applications. Magn Reson Med 45:708-710, 2001.

Brain Chemistry↗

Advances in sensitivity encoding with arbitrary k-space trajectories.

New, efficient reconstruction procedures are proposed for sensitivity encoding (SENSE) with arbitrary k-space trajectories. The presented methods combine gridding principles with so-called conjugate-gradient iteration. In this fashion, the bulk of the work of reconstruction can be performed by fast Fourier transform (FFT), reducing the complexity of data processing to the same order of magnitude as in conventional gridding reconstruction. Using the proposed method, SENSE becomes practical with nonstandard k-space trajectories, enabling considerable scan time reduction with respect to mere gradient encoding. This is illustrated by imaging simulations with spiral, radial, and random k-space patterns. Simulations were also used for investigating the convergence behavior of the proposed algorithm and its dependence on the factor by which gradient encoding is reduced. The in vivo feasibility of non-Cartesian SENSE imaging with iterative reconstruction is demonstrated by examples of brain and cardiac imaging using spiral trajectories. In brain imaging with six receiver coils, the number of spiral interleaves was reduced by factors ranging from 2 to 6. In cardiac real-time imaging with four coils, spiral SENSE permitted reducing the scan time per image from 112 ms to 56 ms, thus doubling the frame-rate.

Brain↗

Sensitivity-encoded spectroscopic imaging.

Sensitivity encoding (SENSE) offers a new, highly effective approach to reducing the acquisition time in spectroscopic imaging (SI). In contrast to conventional fast SI techniques, which accelerate k-space sampling, this method permits reducing the number of phase encoding steps in each phase encoding dimension of conventional SI. Using a coil array for data acquisition, the missing encoding information is recovered exploiting knowledge of the distinct spatial sensitivities of the individual coil elements. In this work, SENSE is applied to 2D spectroscopic imaging. Fourfold reduction of scan time is achieved at preserved spectral and spatial resolution, maintaining a reasonable SNR. The basic properties of the proposed method are demonstrated by phantom experiments. The in vivo feasibility of SENSE-SI is verified by metabolic imaging of N-acetylaspartate, creatine, and choline in the human brain. These results are compared to conventional SI, with special attention to the spatial response and the SNR.

Brain↗

Monitoring the intragastric distribution of a colloidal drug carrier model by magnetic resonance imaging460.

PURPOSE: Monitoring the distribution of drugs or drug delivery systems in the human gastrointestinal tract is an important prerequisite for the design of orally administered drugs. We investigated the intragastric distribution of a colloidal drug delivery system (liposomes containing the contrast agent Gd-DOTA) by magnetic resonance imaging. METHODS: Following ingestion of a liquid or a solid meal, gastric distribution of liposomes released from a capsule and the fat component of the solid meal were tracked in 7 healthy subjects for 90 min. Liposomes were identified in gastric content by the increased signal intensity provided by the encapsulated Gd-DOTA. RESULTS: With the liquid meal, liposomes initially formed a layer on the surface before distributing in 86 +/- 2% of gastric content (maximum distribution volume) within 42 +/- 6 min. With the solid meal, maximum distribution (7 +/- 1%, reached within 24 +/- 6 min) was confined to a small volume in the fundus without forming a layer, suggesting that distribution was related to the accessible liquid compartment. Fat distribution was inhomogeneous and concentrated in the fundus. CONCLUSIONS: Intragastric distribution of a colloidal drug carrier model, such as Gd-DOTA-filled liposomes, varies between meals of different composition. These differences can be monitored in three dimensions in humans by MRI.

Adult↗

Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs.

Magnetic resonance imaging (MRI) is a widely accepted tool for the diagnosis of a variety of disease states. However, the presence of an implanted pacemaker is considered to be a strict contraindication to MRI in a vast majority of centers due to safety concerns. In phantom studies, the authors investigated the force and torque effects of the static magnetic field of MRI on pacemakers and ICDs. Thirty-one pacemakers (15 dual chamber and 16 single chamber units) from eight manufacturers and 13 ICDs from four manufacturers were exposed to the static magnetic field of a 1.5-Tesla MRI scanner. Magnetic force and acceleration measurements were obtained quantitatively, and torque measurements were made qualitatively. For pacemakers, the measured magnetic force was in the range of 0.05-3.60 N. Pacemakers released after 1995 had low magnetic force values as compared to the older devices. For these devices, the measured acceleration was even lower than the gravity of the earth (< 9.81 N/kg). Likewise, the torque levels were significantly reduced in newer generation pacemakers (< or = 2 from a scale of 6). ICD devices, except for one recent model, showed higher force (1.03-5.85 N), acceleration 9.5-34.2 N/kg), and torque (5-6 out of 6) levels. In conclusion, modern pacemakers present no safety risk with respect to magnetic force and torque induced by the static magnetic field of a 1.5-Tesla MRI scanner. However, ICD devices, despite considerable reduction in size and weight, may still pose problems due to strong magnetic force and torque.

Contraindications↗

Effects of vigabatrin on brain GABA+/CR signals in patients with epilepsy monitored by 1H-NMR-spectroscopy: responder characteristics.

PURPOSE: Vigabatrin (VGB) is a new antiepileptic drug that increases the human brain gamma-aminobutyric acid (GABA) level by irreversibly inhibiting GABA transaminase. Although some patients respond to VGB with a significant seizure reduction, others do not. The aim of this study was to identify possible responders before or in an early phase of VGB treatment by measuring the GABA and homocarnosine contaminated with macromolecules/creatine and phosphocreatine ratio (GABA+/Cr) signal by means of proton-nuclear magnetic resonance (1H NMR) spectroscopy. METHODS: Measurements were performed immediately before and after a titration period of 1 month (2 g/day during the past 2 weeks). A third measurement followed a maintenance period of 3 months (2 or 3 g/day). In 14 patients with drug-resistant temporal lobe epilepsy and 3 patients with occipital lobe epilepsy, GABA+/Cr was measured in the ipsilateral (i.e., epileptogenic) hemisphere and contralateral (i.e., nonepileptogenic) hemisphere in a volume of 8 cm3. RESULTS: Depending on the therapeutic efficacy of VGB, we defined three groups: (a) full responders (n = 7), (b) nonresponders (n = 7), and (c) partial responders (n = 3). The nonresponders had no significant change in the GABA+/Cr signal during the treatment compared with baseline. The full responders had a significant increase of the GABA+/Cr signal during the whole treatment phase and a lower ipsilateral level at baseline. The partial responders had also a lowered ipsilateral GABA+/Cr signal at baseline and an increase during treatment but a decrease when the seizures started again. CONCLUSIONS: Responders to VGB could be identified by a lower ipsilateral baseline GABA+/Cr signal and a steeper increase during VGB treatment. However, it was not possible to predict the duration of the response (full versus partial responder) with these criteria.

Adolescent↗

Proton magnetic resonance spectroscopy characteristics of a focal cortical dysgenesis during status epilepticus and in the interictal state.

We report the magnetic resonance imaging and proton magnetic resonance spectroscopic findings ((1)HMRS) in a patient with a focal cortical dysgenesis in the right superior frontal gyrus during intermittent frontal status epilepticus (IFSE) with simple partial seizures, and after she had become seizure free. During the status epilepticus, demonstrated by simultaneous behavioural and electroencephalographic telemetric long-term monitoring with scalp electrodes and ictal SPECT, we performed a single voxel spectroscopy of the dysgenic cortex. The(1)HMRS was repeated after 20 days when the patient's seizures were controlled. The N-acetyl-aspartate concentration in the focal dysgenic cortex was decreased in the interictal state but more during IFSE. The creatine/phosphocreatine concentration was normal in both instances. There was a clear lactate signal during IFSE, which was no longer visible in the interictal state. To our knowledge this is the first report of a(1)HMRS study of a focal cortical dysgenesis during an intermittent status epilepticus. We interpret the observed changes as signs of histopathological changes inherent to a cortical malformation and of an impaired energy metabolism due to the partial status epilepticus.

Adult↗

Sensitivity encoded cardiac MRI.

Imaging speed is a key factor in most cardiovascular applications of magnetic resonance imaging. Recently, simultaneous signal acquisition with multiple coils has received increasing attention as a means of enhancing scan speed in MRI. Based on this approach, the sensitivity encoding technique SENSE enables substantial scan time reduction by exploiting the inherent spatial encoding effect of receiver coil sensitivity. This work studies the benefit of sensitivity encoding for cardiovascular MRI. SENSE is applied to accelerate common breath-hold imaging as well as real-time imaging by factors up to 3.2. In the breath-hold mode with ECG triggering, this speed benefit has been used both for reducing the breath-hold interval and for improving spatial resolution. In cardiac real-time imaging without triggering and breath control, the SENSE approach has enabled significantly enhanced temporal resolution, ranging down to 13 ms (77 frames/s). Cardiac real-time SENSE is demonstrated in several modes, including real-time imaging of three parallel slices at a rate of 25 triple frames per second.

Electrocardiography↗

Heart motion-adapted MR velocity mapping of blood velocity distribution downstream of aortic valve prostheses: initial experience.

PURPOSE: To investigate blood flow velocities and shear rates at two distances downstream of an artificial aortic valve in patients. MATERIALS AND METHODS: Blood velocity was quantified downstream of the valve prosthesis (for replacement after aortic valve stenosis or combined stenosis and regurgitation) in 10 patients by using a magnetic resonance (MR) cine velocity mapping method in which the imaging section position is adapted according to the excursion of the valvular plane of the heart. Two acquisitions were performed to display the blood velocity distributions one-fourth valve diameter and one valve diameter downstream of the valve and to quantify blood volumes and shear rates. RESULTS: The velocity profiles measured during flow acceleration one-fourth valve diameter downstream were characterized by a distinct pattern of two lateral jets and one central jet of antegrade flow. High shear rates were found along the leaflet tips. The profiles obtained one valve diameter downstream were skewed, with varying velocity patterns among patients. Peak shear rates were found close to the vessel wall. With correction for through-plane motion of the valve, the mean apparent regurgitant fraction (+/- SD) was 14% +/- 6; the mean regurgitant fraction without correction was 9% +/- 5. CONCLUSION: The described noninvasive procedure for velocity mapping enables measurements close to the valve and thus evaluation of blood flow patterns with respect to valve design in humans.

Adult↗

Modulation of gastric motor activity by a centrally acting stimulus, circular vection, in humans.

The aims of this study were to investigate gastric motor correlates of vection, a centrally acting stimulus, and relate these responses to the induction of motion sickness symptoms. Antral contractile activity and gastric volume retained after a liquid nutrient meal (600 ml) were assessed by magnetic resonance imaging in healthy subjects during two different protocols. Vection was induced by an optokinetic drum, and subjects repeatedly rated the intensity of vection and nausea on 0-10 analog scales. Vection delayed gastric emptying [99% (89-102%) [median (interquartile ranges)] of volume retained at 28 min; control situation: 79% (69-81%), P < 0.05]. Antral contractile activity followed a distinct time course of rapid decrease [-64% (-72 to -59%) change from baseline activity] immediately after onset of drum rotation followed by gradual recovery upon withdrawal of the stimulus. No relationship was found between the severity of nausea and inhibition of gastric emptying or antral contractile activity. The inhibition of antral contractile activity appears to be a good measure of the peripheral response to vection but is probably independent of subjective symptom induction.

Adult↗

Pressure-geometry relationship in the antroduodenal region in humans.

Understanding of the control mechanisms underlying gastric motor function is still limited. The aim of the present study was to evaluate antral pressure-geometry relationships during gastric emptying slowed by intraduodenal nutrient infusion and enhanced by erythromycin. In seven healthy subjects, antral contractile activity was assessed by combined dynamic magnetic resonance imaging and antroduodenal high-resolution manometry. After intragastric administration of a 20% glucose solution (750 ml), gastric motility and emptying were recorded during intraduodenal nutrient infusion alone and, subsequently, combined with intravenous erythromycin. Before erythromycin, contraction waves were antegrade (propagation speed: 2.7 +/- 1.7 mm/s; lumen occlusion: 47 +/- 14%). Eighty-two percent (51/62) of contraction waves were detected manometrically. Fifty-four percent of contractile events (254/473) were associated with a detectable pressure event. Pressure and the degree of lumen occlusion were only weakly correlated (r(2) = 0.02; P = 0.026). After erythromycin, episodes of strong antroduodenal contractions were observed. In conclusion, antral contractions alone do not reliably predict gastric emptying. Erythromycin induces strong antroduodenal contractions not necessarily associated with fast emptying. Finally, manometry reliably detects ~80% of contraction waves, but conclusions from manometry regarding actual contractile activity must be made with care.

Duodenum↗

Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme.

Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest as well as under physiological stress. Sample images are presented with scan times per image down to 13 msec at a spatial resolution of 4.1 mm, and 27 msec at a resolution of 2.6 mm. Moreover, multiple slice real-time imaging is demonstrated at a rate of 38 double-frames per second.

Artifacts↗

Contrast-enhanced 3D MRA using SENSE.

Sensitivity encoding (SENSE) was used to improve the performance of three-dimensional contrast-enhanced magnetic resonance angiography (3D CE-MRA). Utilizing an array of receiver coils for sensitivity encoding, the encoding efficiency of gradient-echo imaging was increased by factors of up to three. The feasibility of the approach was demonstrated for imaging of the abdominal vasculature. On the one hand, using a SENSE reduction factor of two, the spatial resolution of a breath-hold scan of 17 seconds was improved to 1.0 x 2.0 x 2.0 mm(3). On the other hand, using threefold reduction, time-resolved 3D CE-MRA was performed with a true temporal resolution of 4 seconds, at a spatial resolution of 1.6 x 2.1 x 4.0 mm(3). CE-MRA with SENSE was performed in healthy volunteers and patients and compared with a standard protocol. Throughout, diagnostic quality images were obtained, showing the ability of sensitivity encoding to enhance spatial and/or temporal resolution considerably in clinical angiographic examinations.

Aged↗

PRESTO-SENSE: an ultrafast whole-brain fMRI technique.

A new ultrafast MR imaging method is proposed and tested, which enables whole-brain fMRI with a true temporal resolution of 1 sec. The method combines a 3D PRESTO pulse sequence with the concept of sensitivity-encoding with multiple receiver coils (SENSE). The so-called PRESTO-SENSE technique is demonstrated on a set of functional block-type motor and visual experiments and compared with conventional functional imaging techniques, such as PRESTO and EPI. Comparable image quality and activation areas are found with all sequences. The noise characteristics of the proposed method are analyzed in detail and their implications for ultrafast fMRI studies are discussed. Magn Reson Med 43:779-786, 2000.

Brain↗

Single-quantum coherence filter for strongly coupled spin systems for localized (1)H NMR spectroscopy.

A pulse sequence for localized in vivo (1)H NMR spectroscopy is presented, which selectively filters single-quantum coherence built up by strongly coupled spin systems. Uncoupled and weakly coupled spin systems do not contribute to the signal output. Analytical calculations using a product operator description of the strongly coupled AB spin system as well as in vitro tests demonstrate that the proposed filter produces a signal output for a strongly coupled AB spin system, whereas the resonances of a weakly coupled AX spin system and of uncoupled spins are widely suppressed. As a potential application, the detection of the strongly coupled AA'BB' spin system of taurine at 1.5 T is discussed.

Animals↗