PubMed Health⌕ Search

Biomedical subjects

P Boesiger

Publications and source records attributed to P Boesiger.

At least 91 records · Page 5Linked to original sources

Automatic accurate non-invasive quantitation of blood flow, cross-sectional vessel area, and wall shear stress by modelling of magnetic resonance velocity data.

OBJECTIVES: To apply a new, automatic and non-invasive method for quantification of blood flow, dynamic cross-sectional vessel area, and wall shear stress (WSS) by in vivo magnetic resonance velocity mapping of normal subjects. DESIGN: Prospective, open study. MATERIALS: Six young volunteers. METHODS: A three-dimensional paraboloid model enabling automatic determination of blood flow, vessel distensibility and WSS was applied to blood velocity determinations in the common carotid artery. Blood flow was also determined by a manual edge detection method. RESULTS: Using the new method, the common carotid mean blood flow was 7.28 (5.61-9.63) (mean (range)) ml/s. By the manual-method blood flow was 7.21 (5.55-9.60) ml/s. Mean luminal vessel area was 26% larger in peak systole than in diastole. Mean/peak WSS was 0.82/2.28 N/m2. Manually and automatically determined flows correlated (r2 = 0.998, p < 0.0001). WSS and peak centre velocity were associated (r2 = 0.805, p < 0.0001). CONCLUSIONS: Blood flow, luminal vessel area dilatation, and WSS can be determined by the automatic three-dimensional paraboloid method. The hypothesis of association between peak centre velocity and WSS was not contradicted by the results of the present study.

Adult↗

Gastric emptying and motility: assessment with MR imaging--preliminary observations.

PURPOSE: To evaluate a magnetic resonance (MR) imaging method for simultaneous assessment of gastric emptying and motility. MATERIALS AND METHODS: Gastric emptying and motility were measured in nine volunteers after ingestion of a liquid meal. A specially designed MR imaging protocol was used that allowed simultaneous assessment of gastric emptying (spatial resolution, 1.5 mm; corrected for gastric secretion volume) and gastric motility (temporal resolution, 1.2 seconds; spatial resolution, 3.1 mm). To evaluate the ability to detect small changes in gastric motor activity with findings from this method, the influence of a prokinetic agent (loxiglumide) on gastric emptying and motility was tested in five volunteers. RESULTS: Each contraction could be individually visualized at MR imaging. Administration of loxiglumide resulted in decreased gastric half-emptying time (mean +/- 1 standard error of the mean, 88.1 minutes +/- 6.3 for the placebo and 39.1 minutes +/- 6.7 for loxiglumide) and increased gastric motility (contraction frequency, 2.26 contractions per minute +/- 0.15 for the placebo and 3.04 per minute +/- 0.04 for loxiglumide). CONCLUSION: MR imaging makes it feasible to study gastric emptying and gastric motility and to determine the influence of drugs on gastric motor activity.

Adult↗

Guidewire antennas for MR fluoroscopy.

Before MRI can be used for guiding vascular interventions, the problem of dependably visualizing guidewires must be solved. Ideally, the position and curvature of the tip of the guidewire should be visible to facilitate steering through the vascular system. In this paper, various antennas are described that can be incorporated into a guidewire tip. These antennas allow the guidewire to be visualized with high contrast. Computer simulation and experimental evidence are presented showing the value of adding a passive MR signal source, with a short T1, internal to the coil. The internal source increases the available signal, narrows the apparent width of the guidewire, and allows the use of fast imaging sequences.

Blood Vessels↗

[Function of the residual myocardium after infarct and prognostic significance].

Changes of the left ventricle after myocardial infarction are characterized by geometric, structural, and vascular alterations, which have been summarized under the term "remodeling". This process takes place in the infarct region as well as in the surviving myocardium. Depending on to the size of infarction and the degree of neurohumoral activation, the left ventricle demonstrates diastolic dysfunction which may finally lead to systolic failure. The residual myocardium develops progressive myocyte hypertrophy and interstitial fibrosis. These structural alterations are due to changes in loading conditions and stimulation of the neurohumoral system with an activation of local paracrine and autocrine factors. Myocardial function can be assessed by different non-invasive (echocardiography, radionuclide ventriculography, magnetic resonance imaging, etc.) or invasive methods (e.g., simultaneous pressure-volume measurements). "Myocardial tagging" based on magnetic resonance imaging allows the assessment of 3D-motion of the left ventricle by labelling specific myocardial regions with a rectangular grid. A systolic "wringing" motion with clock-wise rotation at the base and counter-clockwise rotation at the apex has been described in normal subjects. In the ischemic myocardium, delayed relaxation with a prolonged back-rotation (untwisting) has been reported during early diastole, whereas decreased systolic contraction with delayed diastolic rotation has been observed in non-Q-wave infarction. In patients with anterolateral aneurysms, a complete loss of systolic rotation has been demonstrated. The prognostic significance of LV "remodeling" has been emphasized by several authors: The size of infarction, LV volume, LV ejection fraction, as well as the degree of neurohumoral activation have been identified as being associated with an unfavorable clinical outcome. Yearly mortality rates have been reported to range between 15 and 17% in patients with large infarcts and marked LV dilatation and between 3 and 7% in patients with small to medium-sized infarcts.

Diagnostic Imaging↗

Increased excitatory amino acid levels in brain cysts of epileptic patients.

We studied two epileptic patients with arachnoid brain cysts by proton magnetic resonance spectroscopy (1H MRS). In addition, histochemical analyses of surgical specimens, cerebrospinal fluid, and cystic fluid were performed in one of the patients. In both patients, greatly increased levels of excitatory amino acids (EAAs) glutamate and aspartate were present in the cystic fluid, while there was only a moderate increase of glutamate in the epileptogenic brain tissue adjacent to the cyst in one of the patients. In non epileptic brain regions, no elevations of the EAAs were present. Since EAAs are involved in induction and maintenance of epileptogenesis, their extremely high concentrations in the cystic fluid may explain seizures in some patients with such brain cysts. Our findings may have therapeutical consequences for patients with drug resistant epilepsy, in whom elevated concentrations of EAAs in the cysts can be verified. Surgery with the aim to create a communication between the cyst and the subarachnoidal space may prevent an accumulation of the EAAs and thus result in a relief of seizures.

Adolescent↗

In vivo wall shear stress measured by magnetic resonance velocity mapping in the normal human abdominal aorta.

OBJECTIVE: To apply a new non-invasive method for quantification of in vivo wall shear stress (WSS) by magnetic resonance (MR) FAcE velocity mapping and measure WSS in the human abdominal aorta. DESIGN: Prospective, open study. MATERIAL: Six volunteers. METHODS: MR FAcE velocity method was developed for measurements of mean, maximum, minimum WSS and oscillating shear index (OSI) values at the anterior and posterior walls of suprarenal and infrarenal abdominal aorta. RESULTS: The mean, maximum and minimum WSS values were 0.63/0.28, 4.07/2.72 and -0.71/-1.00 N/m2, respectively, in the suprarenal/infrarenal aorta. The mean WSS was 0.35 N/m2 (p < 0.001) and the maximum WSS was 1.36 N/m2 (p < 0.0001) lower in the infrarenal aorta than in the suprarenal aorta. Mean, maximum minimum WSS and OSI values in the infrarenal position differed (p < 0.01) between the anterior and posterior walls. CONCLUSION: WSS can be determined in vivo by MR FAcE velocity technique. Since the lowest WSS values were measured in the infrarenal, posterior blood-to-wall interface, the theory of more pronounced atherosclerosis development in low and oscillating WSS domains was not contradicted by the results of the present study.

Adult↗

Role of cholecystokinin in the regulation of liquid gastric emptying and gastric motility in humans: studies with the CCK antagonist loxiglumide.

BACKGROUND: Exogenous cholecystokinin (CCK) inhibits antral motility and slows gastric emptying (GE) but the effect of endogenous CCK on the gastric motor mechanisms responsible for GE remains unclear. METHODS: The effect of the CCK-A antagonist loxiglumide (LOX) on GE and motility was studied using magnetic resonance imaging in six healthy volunteers after ingestion of 500 ml Intralipid 10% (550 kcal). Subjects were studied in the supine position on two occasions during intravenous infusion of LOX (66 mumol/kg/h for 10 min followed by 22 mumol/kg/h) or placebo. GE was determined every 15 minutes using transaxial abdominal scans and motility was studied by means of 120 coronal scans, 1.2 seconds apart. For each coronal image the proximal and distal (antral) diameters were measured at a fixed point in the stomach to determine contraction frequency (ACF) and amplitude (AMP). RESULTS: GE was faster during LOX infusion than placebo (t1/2 31 (22) versus 115 (67) minutes, p < 0.03). There was little variation in the diameter of the proximal stomach with either LOX or placebo. In the distal stomach marked contractile activity was observed during LOX (ACF 2.9 (0.2) versus 1.5 (2.9) during placebo, p < 0.01). AMP also increased during LOX compared with placebo (56 (22)% versus 27 (16)%, p < 0.001). CONCLUSION: The increases in antral motility are likely to contribute to the acceleration of GE and suggest that CCK may regulate GE by acting on the distal stomach although an effect on the proximal stomach cannot be excluded.

Adult↗

Detection of hidden metabolites by localized proton magnetic resonance spectroscopy in vivo.

Magnetic resonance spectroscopy (MRS) allows the assessment of chemical substances in living tissue and the detection of biochemical changes associated with certain diseases. In vivo MRS, however, is usually limited in sensitivity and spectral resolution. Many resonance lines originating from metabolites of interest are overlapped by signals of other metabolites and are therefore not visible in conventional MR spectra. In order to overcome this limitation, three localized methods, a technique making use of a spectral difference, a multiple quantum filter technique, and a two-dimensional J-resolved technique, were evaluated theoretically and experimentally for the detection of gamma-aminobutyric acid (GABA) both in vitro and in vivo. All three methods are able to produce the desired results at high metabolite concentrations in vitro. For in vivo measurements the spectral difference method proofed to be most appropriate due to its relatively high sensitivity and its short acquisition time.

Adult↗

[From left hypertrophy to heart insufficiency: hemodynamic and clinical findings].

The pathophysiology of left-ventricular hypertrophy is characterized by structural remodeling with increasing content of collagen and development of ventricular dilatation ('Gefügedilatation'). According to recent clinical view points, three stages may be distinguished: first stage, compensation, second stage, diastolic dysfunction with delayed relaxation and decrease of the passive-elastic properties, third stage, systolic and diastolic dysfunction with decreasing pump function and signs of left-ventricular failure. Diastolic dysfunction is linked to delayed rotation during isovolumetric relaxation (delayed 'untwisting') which leads to decreased ventricular filling. These changes of the myocardial adaptation process may be prevented and the vicious circle interrupted by appropriate therapeutic strategies.

Adaptation, Physiological↗

Biopsy needle susceptibility artifacts.

Understanding the appearance of thin metallic structures in magnetic resonance imaging is important for evaluating the potential role of MRI in guiding and monitoring percutaneous interventions. As most MR compatible instruments are made from materials with a susceptibility different from water, their visibility is enhanced beyond what is expected on the grounds of displaced water alone. Unfortunately, this artifactually enhanced visibility is not constant, but instead depends on a variety of factors. This article presents computer simulations of the image distortion resulting from magnetic susceptibility differences between a needle and the surrounding tissue. The simulations show not only an artifact size that is dependent on needle composition, orientation, and pulse sequence, but also a corresponding shift of the artifact center away from the actual center of the needle. These effects place limits on the accuracy of MRI-guided needle tip placement.

Artifacts↗

Assessment of systolic and diastolic LV function by MR myocardial tagging.

Heart failure has been divided into several different forms depending on etiology, clinical course and pathophysiology of left ventricular (LV) dysfunction. Systolic and diastolic dysfunction are characterized by a reduced cardiac output with normal (= diastolic dysfunction) or depressed (= systolic dysfunction) LV pump function. New diagnostic techniques such as magnetic resonance imaging (MRI) allow to determine noninvasively LV 3D motion by labelling specific myocardial regions (= myocardial "tagging") with a rectangular or radial grid. From the deformation of this grid rotational and translational motion of the heart can be derived. A "wringing" motion of the left ventricle has been described during systole which includes a clockwise rotation at the base and a counterclockwise rotation at the apex. During diastole, an "untwisting" motion has been demonstrated. In the normal heart, diastolic "untwisting" occurs primarily during isovolumic relaxation, analogous to the systolic "wringing" which takes place mainly during isovolumic contraction. A prolongation of the "untwisting" motion was found in the hypertrophied (aortic stenosis) and hibernating myocardium. Thus, heart failure is associated with profound alterations in the mechanical function of the heart which are manifested by changes in systolic "wringing" and diastolic "untwisting" motion.

Animals↗

Accurate velocity mapping with FAcE.

Spin dislocation between the slice selection, phase encoding, and frequency encoding is a source of image distortions. Two strategies can be pursued to improve the appearance of moving spins in an image. Either the sequence is made equally sensitive to velocity-dependent dislocation artifacts for all spatial directions or the sensitivity is reduced with a shorter echo time. The first approach increases the dislocation for the phase-encoding direction and is therefore not useful if velocity maps with minimal distortion are the goal. FAcE (FID acquired echoes) is a sequence with separate sampling of the left and right k-space half-planes that allows for very short echo times. It was applied for velocity mapping of flow in the slice select direction. Special attention was paid to a compact design of the velocity-encoding select gradient to achieve short echo times even with high velocity sensitivity. Artifacts introduced by in-plane motion were studied for FAcE and conventional gradient-echo sequences, both in phantom experiments and simulation. FAcE allows for very short echo times with inherent motion compensation of the frequency-encoding gradient. Thus, both motion-related dislocation artifacts and signal voids due to coherence loss in regions with irregular flow are minimal.

Artifacts↗

Striatal glucose metabolism and dopamine D2 receptor binding in asymptomatic gene carriers and patients with Huntington's disease.

We used PET scans with the tracers [18F]fluorodeoxyglucose (FDG) and [11C]raclopride (RACLO) to study glucose metabolism and dopamine D2 receptor binding in the caudate nucleus and putamen of 18 carriers of the Huntington's disease gene mutation (10 asymptomatic subjects and eight untreated symptomatic Huntington's disease patients in an early disease stage). We also performed MRI scans and measured the bicaudate ratio (BCR) in the same subjects. Data were compared with those from nine mutation-negative members of Huntington's disease families and separate groups of age matched controls. The PET scans were repeated 1.5-3 years later in six of the asymptomatic gene carriers. Symptomatic Huntington's disease patients showed a marked reduction of FDG and RACLO uptake in the caudate nucleus and putamen and a significant increase of BCR. Asymptomatic mutation carriers revealed significant hypometabolism in the caudate nucleus and putamen. The RACLO binding was significantly decreased in the putamen. Decrements of caudate nucleus tracer uptake, particularly RACLO, correlated significantly with BCR increases in both symptomatic and asymptomatic gene carriers. In asymptomatic carriers, metabolic and receptor binding decreases were also significantly associated with the CAG repeat number but not with the individual's age. Discriminant function analysis correctly classified clinical and genetic status in 24 of 27 subjects on the basis of their striatal PET values (83% sensitivity and 100% specificity). Three asymptomatic mutation carriers were classified/grouped together with mutation-negative subjects, indicating that these individuals had normal striatal RACLO and FDG uptake. Follow-up PET data from gene-positive subjects showed a significant reduction in the mean striatal RACLO binding of 6.3% per year. Striatal glucose metabolism revealed an overall non significant 2.3% decrease per year. These data indicate that asymptomatic Huntington's disease mutation carriers may show normal neuronal function for a long period of life. These findings also suggest that it may be possible to predict when an asymptomatic gene carrier will develop clinical symptoms from serial PET measurements of striatal function.

Adult↗

Measurement of proximal and distal gastric motility with magnetic resonance imaging.

The precise motor mechanisms associated with gastric emptying of nutrient liquids are unclear, in part because of difficulties in measuring the motility from the proximal and distal stomach simultaneously. We have now examined proximal and distal gastric motility, using a novel magnetic resonance imaging (MRI) technique. In seven healthy volunteers (4 males, 3 females; 27-37 yr), gastric emptying and motility were determined on two occasions after ingestion of 500 ml 10% and 25% dextrose labeled with 1 mM gadolinium tetraazacyclododecane tetraacetic acid, using a 1.5-tesla Philips Gyroscan ACS II scanner. Gastric emptying was determined every 15 min with a series of transaxial scans. After each series of transaxial scans, 120 coronal scans, 1.2 s apart, were performed through the antrum and proximal stomach. For each coronal slice the diameters of the proximal stomach and the antrum were measured to determine the number of contractions per minute and depth (%basal diameter). Gastric emptying (half-emptying time) was faster after ingestion of 10% compared with 25% dextrose (49 +/- 15 vs. 118 +/- 37 min; P < 0.01). After both meals, the diameter of the proximal stomach remained relatively constant, whereas there were marked fluctuations in the diameter of the antrum. Mean (+/- SD) frequency (2.8 +/- 0.6 vs. 2.0 +/- 0.8/min; P < 0.001) and depth (40 +/- 17% vs. 34 +/- 16%; P < 0.04) of antral contractions were higher after 10% dextrose compared with 25% dextrose. Rapid MRI techniques allow simultaneous measurement of both gastric emptying and motor function of different gastric regions. The increase in the frequency and depth of distal gastric contractions during ingestion of 10% compared with 25% dextrose supports the concept that the antrum contributes to the regulation of gastric emptying of nutrient liquids.

Adult↗

Evaluation of delayed gastric emptying in diabetic patients with autonomic neuropathy by a new magnetic resonance imaging technique and radio-opaque markers.

OBJECTIVE: Our objective was to validate a new noninvasive magnetic resonance imaging (MRI) technique for diagnosis of delayed gastric emptying by using radio-opaque markers (ROMs) in diabetic patients with and without cardiovascular autonomic (CAN) and peripheral sensomotoric neuropathy (PSN). RESEARCH DESIGN AND METHODS: Fifteen diabetic outpatients were recruited, eight with CAN and PSN (group A, age 28-61 years, mean diabetes duration 27 years) and seven without CAN (group B, age 28-60 years, mean diabetes duration 16 years). Gastric emptying and motility were assessed with ROMs and MRI in random order. After an overnight fast either a test meal (451 kcal) containing a capsule with 10 ROMs is eaten and a supine plain abdominal X ray is taken after 6 h or 500 ml intralipid 10% (550 kcal) is swallowed for the MRI study, using a 1.5 Tesla Gyroscan ACS II (Philips, Eindohoven, The Netherlands). Computer-assisted segmentation of images was used to measure gastric emptying (T1/2, min) over 125 min, contraction frequency (F, min-1), mean contraction amplitude (CA, % basal), and velocity (V, cm/s). Blood glucose was kept constant at 5.0-8.0 mmol/l. RESULTS: In group A, 6.1 +/- 1.36 ROMs (mean +/- SE) were retained in the stomach after 6 h and 0 ROM in group B, indicating a significant delay of gastric emptying in patients with CAN. The MRI study revealed a significantly longer gastric emptying (P < 0.005) in group A (T1/2 = 124 +/- 10 min) as compared with group B (T1/2 = 85 +/- 18 min). There was no difference in F, CA, and V between the two groups: F 2.9 +/- 0.07 and 2.7 +/- 0.1 (min-1), CA 26.8 +/- 1.2 and 29.6 +/- 1.6 (% basal), V 0.43 +/- 0.02 and 0.40 +/- 0.02 (cm/s), respectively. CONCLUSIONS: MRI offers the possibility of visualizing and examining exactly the mechanisms responsible for gastric emptying and is characterized by a high specificity but a lower sensitivity as compared with ROMs, which proved to be an ideal screening test for diagnosis of gastroparesis in clinical practice.

Adult↗

Coronary artery imaging by magnetic resonance.

Non-invasive visualization of the coronary arteries represents a major challenge in modern cardiology, but this goal may be achieved in the near future by MR angiography. Possible applications are non-invasive diagnosis of coronary artery disease, and follow-up examinations for therapy control after PTCA, in order to detect restenosis at an early stage. A multiple slice technique (2 mm slice thickness, with a spatial resolution of 1 x 1 mm, Philips Gyroscan ACS-II, 1.5 Tesla) was used. Ten volunteers were imaged and 10 patients with coronary artery disease were examined before and after PTCA. MR measurements were validated by quantitative coronary angiography. The diameters of the proximal coronary arteries as measured by both methods were compared, and a good correlation was found (r = 0.76). Thus, it is concluded that non-invasive visualization of the coronary arteries is possible before and after PTCA and allows to determine potential restenoses. However, patient cooperation is essential for good image quality. Moreover, limited spatial image resolution and breathing artifacts restrict MR coronary angiography today to be used as a routine diagnostic tool for the diagnosis of coronary artery disease.

Adult↗

Quantification of blood flow patterns in human vessels by magnetic resonance imaging.

The quantitative assessment of velocity fields can help to get a better understanding of complicated flow patterns which are considered to play an important role in atherosclerotic plaque formation. Magnetic resonance imaging offers the possibility of non-invasive visualization and quantification of blood flow in many larger human arteries and veins. However, the assessment of complex blood flow patterns with conventional gradient echo flow sequences suffer from severe image artifacts. In order to overcome these problems, a partial echo signal acquisition technique which strongly reduces such artifacts may be applied. Using this technique, three dimensional velocity fields were measured in a bifurcation model, in the human carotid bifurcation and in the human aorta, right downstream of the aortic valve.

Aortic Valve↗

Comparison of magnetic resonance imaging and Laser Doppler Anemometry velocity measurements downstream of replacement heart valves: implications for in vivo assessment of prosthetic valve function.

BACKGROUND AND AIM OF THE STUDY: The non-invasive, in-vivo assessment of prosthetic valve function is compromised by the lack of accurate measurements of the transvalvular flow fields or hemodynamics by current techniques. Short echo time magnetic resonance imaging (MRI) may provide a method for the non-invasive, in vivo assessment of prosthetic valve function by accurately measuring changes in the transvalvular flow fields associated with normal and dysfunctional prosthetic valves. The objectives of these in vitro experiments were to investigate the potential for using MRI as a tool to measure the complex flow fields distal to replacement heart valves, and to assess the accuracy of MRI velocity measurements by comparison with Laser Doppler Anemometry (LDA), a gold standard. METHODS: The velocity fields downstream of tilting disc, bileaflet, ball and cage, and pericardial tissue valves were measured using both three-component LDA and MRI phase velocity encoding under a steady flow rate of 22.8 l/min, simulating peak systolic flow. The valves were tested under normal and stenotic conditions to assess the MRI capabilities under a wide range of local flow conditions, velocities and turbulence levels. A new short echo time MRI technique (FAcE), which allowed velocity measurements in stenotic jets with high turbulence, was tested. RESULTS: Good overall agreement was obtained between the MRI velocity measurements and the LDA data. The MRI velocity measurements adequately reproduced the spatial structure of the flow fields. In most cases peak velocities were accurately measured to within 15%. CONCLUSIONS: The results indicate that the FAcE MRI method has the potential to be used as a diagnostic tool to assess prosthetic valve function.

Aortic Valve↗