Ethical opinions.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to P Heasman.
Explore the source record for details and available documents.
OBJECTIVES: To evaluate patient compliance with toothbrushing instructions using a data logger and a brushing diary. METHODS: Dental patients were provided with powered toothbrushes modified to carry electronic data loggers. Demonstration of the most effective way to use the toothbrush was provided with instructions to brush for 2 minutes morning and evening. Data logger brushes were supplied for two episodes of 8 weeks. Brushing time was also recorded in a diary during episode 1. RESULTS: Data from 14 brushes (2,287 recordings) were used to evaluate compliance in episode 1 Nine brushes (1,526 recordings) were used in episode 2 A total of 2,333 brushing events were reported manually in the diaries. Data logger records during episode 1 showed that only 34% of events were compliant with the instruction of a 2 minute brushing time, 20% were partially compliant (within +/-30s of 2 minutes), and 46% of events were non-compliant (>30s from 2 minutes). The respective proportions for episode 2 were 24%, 24% and 52%. Diary data reported 58% of events as compliant with 42% non-compliant. CONCLUSIONS: Manually completed brushing diaries do not provide an accurate reflection of subjects' compliance with toothbrushing instructions.
Explore the source record for details and available documents.
Powered toothbrushes were first developed over 50 years ago. More recent advances in design and technology mean that there are now a considerable number of different models available on the market. It is not surprising, therefore, that patients, when considering buying a powered toothbrush, often turn to their general dental practitioner for advice.
The objective of this three treatment, three period, single blind, cross-over trial was to evaluate the efficacy of three toothbrushes in a cohort of children undergoing fixed appliance orthodontic therapy. The brushes used were: (1) Dental Logic HP550 with regular brush head HP5924 (Philips, U.K.); (2) Braun Oral B Plaque Remover (D7) with dedicated orthodontic brush head OD5-1 (Braun AG, Germany); and (3) a manual dedicated orthodontic toothbrush (P35, Oral B Laboratories, Calif.). Sixty orthodontic patients, aged 10 to 16 years and wearing upper and lower fixed appliances, were screened and recruited with parental consent. After an oral soft tissue examination at baseline, the percentage of plaque-covered tooth surfaces and gingival bleeding sites were recorded using visible plaque and gingival bleeding indexes. Each subject was randomly allocated to one of three groups (n = 20) with brushing sequences 1-2-3, 2-1-3, 3-2-1. The first brush was given 2 weeks after baseline (visit 1). The time interval for using each brush was 4 weeks at the end of which visible plaque and gingival bleeding indexes were recorded and a further prophylaxis given. Statistical analysis was undertaken with analysis of variance. Data were analyzed on a site-specific basis; buccal smooth and interproximal surfaces, lingual smooth and interproximal surfaces. At baseline the mean visible plaque index for all subjects were; buccal smooth, 52.5% (+/- 22.5%); buccal interproximal, 70.5% (+/- 18.5%); lingual smooth, 68.5% (+/- 21%); lingual interproximal, 76% (+/- 16%). At visit 1, the plaque scores at all surfaces had reduced significantly compared to baseline, but there had been no active treatment. This was attributed to a Hawthorne effect. Subsequently, there were no significant effects on visible plaque (or gingival bleeding) indexes with any toothbrush at any tooth surfaces. This suggests that the new HP550 is equally effective as specifically designed orthodontic toothbrushes in removing plaque from patients with fixed orthodontic appliances.