Modification of glassy carbon surfaces with synthetic laminin-derived peptides for nerve cell attachment and neurite growth.

Interactions between cultured nerve cells and surfaces are of importance for the implantation of biocompatible electrode materials such as glassy carbon (GC). Since implants serve as recording sensors in prosthetic neuroscience, we investigated whether coating electrodes with certain laminin derivatives containing the peptide sequences SIKVAV, CDPGYIGSR, PDSGR, YFQRYLI, and RNIAEIIKDA influences neuronal adhesion and neurite outgrowth in vitro. The coating of GC was performed by electrochemical polymerization and, for comparison, by adsorption or covalent coupling. Electrochemical polymerization is suitable for the coupling of peptides to GC, as shown by amino acid analysis and sequencing. Embryonic chicken retinal ganglion cells and brain cells (days E7 or E17) were used for both attachment and growth studies. Surfaces made by electrochemical polymerization of peptides were more efficient than those made by adsorption or covalent coupling of peptides. Synthetic cyclic peptide derivatives of CDPGYIGSR and 18-mer SIKVAV were found to be more efficient than the linear peptides. Competitive effects that resulted in a decreased cell attachment could be found upon application of soluble peptides. Nevertheless, irrespective of the method of coating, peptides were less efficient compared with the whole laminin molecule, as expected from its multiple adhesion sites. When small GC pins were implanted into the brain of E17 chicken after coating with the 18-mer SIKVAV peptide, nerve cell attachment was observed in vivo. The results suggest that chronically implantable materials may exert a higher neurocompatibility when coated with synthetic peptides.

Amino Acid Sequence

Implantable bioelectric interfaces for lost nerve functions.

Neuronal cells are unique within the organism. In addition to forming long-distance connections with other nerve cells and non-neuronal targets, they lose the ability to regenerate their neurites and to divide during maturation. Consequently, external violations like trauma or disease frequently lead to their disappearance and replacement by non-neuronal, and thus not properly functioning cells. The advent of microtechnology and construction of artificial implants prompted to create particular devices for specialised regions of the nervous system, in order to compensate for the loss of function. The scope of the present work is to review the current devices in connection with their applicability and functional perspectives. (1) Successful implants like the cochlea implant and peripherally implantable stimulators are discussed. (2) Less developed and not yet applicable devices like retinal or cortical implants are introduced, with particular emphasis given to the reasons for their failure to replace very complex functions like vision. (3) Material research is presented both from the technological aspect and from their biocompatibility as prerequisite of any implantation. (4) Finally, basic studies are presented, which deal with methods of shaping the implants, procedures of testing biocompatibility and modification of improving the interfaces between a technical device and the biological environment. The review ends by pointing to future perspectives in neuroimplantation and restoration of interrupted neuronal pathways.

Amino Acid Sequence

Regenerating ganglion cell axons in the adult rat establish retinofugal topography and restore visual function.

The mechanisms of neuronal network response to axotomy are poorly understood. In one of the favoured models used to study the fate of injured neurons in the adult rat visual system, appreciable numbers of retinal neurons survive optic nerve injury under conditions of microglia-targeted neuroprotection. Rescued neurons can regenerate their axons and become target-dependently stabilised after reconnection with their natural visual centres by means of a peripheral nerve graft, which, in addition to guidance, actively supports axonal growth. The mechanisms that control regenerative axonal growth and resynaptogenesis include coordinated cell-cell interactions between growing neurites and target cells in order to establish a meaningful reconnectivity. Here the function of the regenerating visual circuitry was first studied by monitoring the ability of animals to discriminate spatial patterns, and second by recording visual evoked cortical potentials (VEPs) in the same animals. These functions were correlated with neuroanatomical studies of the retinotopic organisation of regenerating axons. To achieve these goals, adult rats were behaviourally trained in a Y-maze to discriminate between vertical and horizontal stripes. Both optic nerves were transected, and the regenerating axons of one optic nerve were guided into the area of optic tract with a peripheral nerve graft according to the protocols of neuroprotection and simultaneous grafting, in order to enable large numbers of axons to reinnervate the major visual targets in the midbrain and thalamus. Postoperative testing of the animals showed a marked improvement of visual perception and behaviour. The VEPs of the same animals were measurable indicating a restoration of the visual circuitry including the ascending corticopedal connections. Neuroanatomical assessment of the fibre topography within the graft and the area of termination revealed a rough topographic organisation that may account for restoration of the function. These results suggest that interrupted central pathways can be functionally reconnected by providing a neuroprotective environment in combination with peripheral nerve grafts to bypass lesions.

Animals

A 'mixed' self-assembled monolayer for an impedimetric immunosensor.

A synthetic peptide with the amino acid sequence 135-154 of the capsid protein VP1 of the foot-and-mouth-disease virus was modified with omega-hydroxyundecanethiol and applied together with non-derivatised omega-hydroxyundecanethiol for consecutive adsorption onto gold electrodes according to self-assembling procedures. The binding of a specific antibody to prepared recognition layers could be monitored by measurement of impedance or capacitance. In order to avoid non-specific effects, all measurements were performed in the presence of BSA. The complex between the antigenic peptide and the antibody was split by applying 6 M urea solution. The gold electrodes were mounted into an optimised flow-through system in order to perform capacitance-time measurements. The immobilised peptide can be recognised repeatedly by specific antibodies.

Amino Acid Sequence

Interface analysis in biosensor design.

In a survey, the analytical tools to characterise and optimise properties and stabilities of interfaces in thin film biosensors are discussed. After an introduction to microscopic and spectroscopic techniques and different transducers, case studies are presented. They concern bioaffinity sensors with particular emphasis on biomimetic recognition structures, catalytic sensors, transmembrane sensors, cell sensors, and the ambitious goal of addressing individual biomolecular function units.

Biosensing Techniques

[Application of dipeptidylpeptidase IV in formation of the peptide bond].

According to the increasing importance of enzyme catalysed peptide synthesis the capability of the protease dipeptidyl peptidase IV is shown to form the peptide bond. To our best knowledge, it's the first time that has been used successfully proline as one of the amino acids. The formation of the peptide bond is kinetically controlled. Free amino acids have been used as nucleophiles. The reaction media contain 50 vol.-% glycerol. A first approach to a kinetic treatment is shown.